HomeMy WebLinkAboutNOA 10-02-18M IAM I•DADE MUM-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy Regency Plus, Inc. 2000 Locust Gap Highway Mount Carmel, PA 17851 This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER- Product Control Section to be used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami Dade County Product Control Section (In Miami -Dade County) and/ or the AHJ (in areas other than Miami -Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building I DESCRIPTION: Series "5000" White PVC Single Hung Window - L.M.I. I OC Drawingo. RPLS0062, titled" pact Serves 5 00 Single Hung Window - L.M.P', sheets 1 through 5 of 5, dated 11/26/08, with revision J dated 01/08/18, prepared by PTC Product Design Group, LLC, signed and sealed by Robert J. Amoroso, P.E., bearing the Miami -Dade County Product Control Renewal stamp with the Notice of Acceptance number and expiration date by the Miami - Dade County Product Control Section. MISSILE IMPACT RATING: Large and Small Missile Impact Resistant LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state, series, and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/ or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA No. 18-0122.13 and consists of this page 1 and evidence pages E-1, E-2 and E-3, as well as approval document mentioned above. The submitted documentation was reviewed by Manuel Perez, P.E. MIAMI-DADE COUNTY �RTI...4 If, 021(S RECEIVED JUN 0 9 2020 Permitting Department St. Lucie County NOA No. 18-0911.05 Expiration Date: July 22, 2020 Approval Date: October 11, 2018 Page 1 Regency Plus, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 1. EVIDENCE SUBMITTED UNDER PREVIOUS NOA's A. DRAWINGS 1. Manufacturer's die drawings and sections. (Submitted under NOA No. 08-1210.13) 2. Drawing No. RPLS0062, titled "Impact Series 5000 Single Hung Window - LMI" sheets 1 through 5 of 5, dated 11/26/08, with revision J dated 01/08/18, prepared by PTC Product Design Group, LLC, signed and sealed by Robert J. Amoruso, P.E. (Submitted under previous NOA No.18-0122.13) B. TESTS 1. Test reports on: 1) Air Infiltration Test, per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC, TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94 4) Large Missile Impact Test per FBC, TAS 201-94 5) Cyclic Wind Pressure Loading per FBC, TAS 203-94 6) Forced Entry Test, per FBC 2411.3.2.1 (b) and TAS 202-94 along with marked -up drawings and installation diagram of a white PVC single hung window, prepared by National Certified Testing Laboratories, Test Report No. NTCL-110-11537-1, dated 08/18/08, revised on 09/03/08, signed and sealed by Harold E. Rupp, P.E. (Submitted under NOA No. 08-1210.13) C. CALCULATIONS 1. Anchor verification calculations and structural analysis, complying with FBC 5th Edition (2014), dated 09/01/15, prepared by PTC Product Design Group, LLC, signed and sealed by Robert J. Amoruso, P.E. (Submitted under NOA No.15-0618.04) 2. Glazing complies with ASTM E1300.04 D. QUALITY ASSURANCE 1. Miami Dade Department of Regulatory and Economic Resources (RER). E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 17-1114.14 issued to Kuraray America, Inc. for their "Trosifol® Ultraclear, Clear and Color PVB Glass Interlayers" dated 01/18/18, expiring on 07/08/19. 2. Notice of Acceptance No. 16-0712.03, issued to ENERGI Fenestration Solutions USA, Inc., for their White Rigid PVC Exterior Extrusions for Windows and Doors, approved on 08/10/17, expiring on 02/28/18. km Manuel Pe Product Control Elkaminir NOA No.18 9 .05 Expiration Date: July 22, 2020 Approval Date: October 11, 2018 E-1 Regency Plus, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED F. STATEMENTS 1. Statement letter of conformance, complying with FBC 6tn Edition (2017), dated January 8, 2018, prepared by PTC Product Design Group, LLC, signed and sealed by Robert J. Amoruso, P.E. (Submitted under previous NOA No.18-0122.13) 2. Laboratory addendum letters in the Test Report No. NTCL-110-11537-1, issued by National Certified Testing Laboratories, dated 03/31/09 and on 05/01/09, both signed and sealed by Harold E. Rupp, P.E. (Submitted under NOA No. 08-1210.13) 3. Laboratory compliance letter in the Test Report No. NTCL-110-11537-1, issued by National Certified Testing Laboratories, dated 08/18/08, signed and sealed by Harold E. Rupp, P.E. (Submitted under NOA No. 08-1210.13) G. OTHERS 1. Notice of Acceptance No. 15-0618.04, issued to Regency Plus, Inc. for their Series "5000" White PVC Single Hung Window — L.M.I., approved on 10/01/15 and expiring on 07/22/19. Manuel er z, P.E. Product Cont r I Exa finer NOA N 18- 11.05 Expiration Date: Ju 22, 2020 Approval Date: October 11, 2018 E-2 Regency Plus, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 2. NEW EVIDENCE SUBMITTED A. DRAWINGS 1. None B. TESTS 1. None C. CALCULATIONS 1. None D. QUALITY ASSURANCE 1. Miami -Dade Department of Regulatory and Economic Resources (RER) E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 17-1114.14 issued to Kuraray America, Inc. for their "Trosifol® Ultraclear, Clear and Color PVB Glass Interlayers" dated 01/18/18, expiring on 07/08/19. 2. Notice of Acceptance No. 18-0122.02, issued to ENERGI Fenestration Solutions USA, Inc., for their White Rigid PVC Exterior Extrusions for Windows and Doors, approved on 03/08/18, expiring on 02/28/23. F. STATEMENTS 1. Letter from manufacturer requesting a 1-year extension to allow time to perform verification test, dated 06/11/18, signed by Tony Procopio, Plant Manager. 2. Testing agreement letter, dated 06/12/18 between National Certified Testing Laboratories (NCTL) and Regency Plus, Inc., issued by NCTL and signed by Justin L. Bupp, Laboratory Manager. G. OTHERS L Notice of Acceptance No. 18-0122.13, issued to Regency Plus, Inc. for their Series "5000" White PVC Single Hung Window— L.M.I., approved on 03/08/18 and expiring on 07/22/19. 2. This is a one year approval, subjected to successful verification test. Manuel erez, .E. Product Contr 1 Exa er NOA No. 11.05 Expiration Date: July 22, 2020 Approval Date: October 11, 2018 E-3 REGENCY PLUS, INC. IMPACT SERIES 9000 SINGLE HUNG "LNDOW - LMI GENERAL NOTES: 1. THE PRODUCT ANCHORAGE SHOWN HEREIN IS DESIGNED TO COMPLY WITH THE CURRENT EDITION OF THE FLORIDA BUILDING CODE (FBC) INCLUDING THE HIGH VELOCITY HURRICANE ZONE (HVHZ) AT THE DESIGN PRESSURE STATED HEREIN. 2. THE PRODUCT DETAILS CONTAINED HEREIN ARE BASED UPON SIGNED AND SEALED TEST REPORT # ®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® FROM THE MIAMI-DADE COUNTY PRODUCT CONTROL "ST"IAMNANCHORAGEDETAILS INSTALLATION NOTES: 7. MATERIALS: 1. ONE (1) INSTALLATION ANCHOR IS REQUIRED AT EACH Q 7.1 WINDOW FRAME MATERIAL: ENERGI FENESTRATION ANCHOR LOCATION SHOWN. SOLUTIONS USA, INC., WHITE RIGID PVC EXTERIOR EXTRUSIONS FOR WINDOWS AND DOORS PER CURRENT 2. THE NUMBER OF INSTALLATION ANCHORS DEPICTED IS MIAMI-DADE NOTICE OF ACCEPTANCE (NOA). THE MINIMUM NUMBER OF ANCHORS TO BE USED FOR PRODUCT INSTALLATION. Q 72 GLAZING INTERLAYER KURARAY AMERICA, INC. TROSIFOL INTERLAYER PER CURRENT MIAMI DADE NOTICE OF ACCEPTANCE (NOA). ® 8. NOT USED. 9. GLASS MEETS THE REQUIREMENTS OF ASTM E1300-04¢1. 3. SHIM AS REQUIRED AT EACH INSTALLATION ANCHOR THRU MAIN FRAME WITH LOAD BEARING SHIM(S). MAXIMUM ALLOWABLE SHIM SIZE IS 1/4 INCH. SHIM WHERE SPACE OF 1116 INCH OR GREATER OCCURS. SHIM(S) SHALL BE CONSTRUCTED OF HIGH DENSITY PLASTIC OR BETTER. 8. INSTALLATION ANCHORS AND ASSOCIATED HARDWARE MUST BE MADE OF CORROSION RESISTANT MATERIAL OR HAVE A CORROSION RESISTANT COATING. 9. FOR HOLLOW BLOCK AND GROUT FILLED BLOCK, DO NOT INSTALL INSTALLATION ANCHORS INTO MORTAR JOINTS. EDGE DISTANCE 1S MEASURED FROM FREE EDGE OF BLOCK OR EDGE OF MORTAR JOINT INTO FACE SHELL OF BLOCK. 10. INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STREIIGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BY THE ANCHOR MANUFACTURER. 4. FOR INSTALLATION INTO WOOD FRAMING, USE #12 WOOD 10. DESIGNATIONS'W AND'O' STAND FOR THE SCREWS OF SUFFICIENT LENGTH TO ACHIEVE 1-112 INCH 11. INSTALLATION ANCHOR CAPACITIES FOR PRODUCTS FOLLOWING: MINIMUM EMBEDMENT. MINIMUM EDGE DISTANCE IS 7/8 HEREIN ARE BASED ON SUBSTRATE MATERIALS WITH THE X: OPERABLE PANEL INCH. FOLLOWING PROPERTIES: O: FIXED PANEL 5. FOR INSTALLATION THROUGH 1X BUCK TO CONCRETE / &A. WOOD PROTECTION.WOOD- PRESSURE TREATED 11. A V3 INCREASE IN ALLOWABLE STRESS FOR WIND LOADS A MASONRY, OR DIRECTLY INTO CONCRETE 1 MASONRY, (PT) SOUTHERN YELLOW PINE MINIMUM SPECIFIC WAS NOT USED IN THE DESIGN OF THE PRODUCT(S) 1 USE 1/4 INCH IIW ADVANCED THREADFORMTAPCONS OF GRAVIiYOF 0.55 LUMBER MUST COMPLY WITH CURRU SHOWN HEREIN. WIND LOAD DURATION FACTOR (Cd=1.6) HAS BEEN USED FOR ANCHOR SUFFICIENT LENGTH TO ACHIEVE THE FOLLOWING: EDITION FBC/FRC AS RELATED TO WOOD PROTECTION. ZL WOOD DESIGN WHERE WOOD -ONLY FAILURE GOVERNS. FOR OTHER MATERIALS, 5.1. CONCRETE SUBSTRATE 5.11 1 112 INCH MINIMUM EMBEDMENT A'. CONCRETE -MINIMUM COMPRESSIVE STRENGTH OF APPROPRIATE SAFETY FACTORS PER THE APPLICABLE 5.1.2. 1-1/21NCH MINIMUM EDGE DISTANCE 2500 psi AND CONFORMS TO ACI 301. B DESIGN STANDARD ARE USED. 52. MASONRY SUBSTRATE C. MASONRY- STRENGTH CONFORMS TO ASTM C90, 521. 1 INCH MINIMUM EMBEDMENT MEDIUM WEIGHT WITH DENSITY> 117 FOR 12. WHERE WIND -BOURNE DEBRIS PROTECTION 522. 21NCH MINIMUM EDGE DISTANCE REQUIREMENTS MOST, USE OF AN APPROVED IMPACT PROTECTIVE SYSTEM IS NOT REQUIRED. 6. FOR PARTING STOP INSTALLATION USE #B X 1 1/2' WOOD SCREWS. 3W INCH MIN. EDGE DISTANCE REQ'D. 7. MINIMUM EMBEDMENT AND EDGE DISTANCE EXCLUDE WALL FINISHES, INCLUDING BUT NOT LIMITED TO STUCCO, FOAM, BRICK VENEER AND SIDING. TABLE OF CONTENTS SHEET REV. SHEET DESCRIPTION 1 E GENERAL NOTES, INSTALLATION NOTES & D.P. CHART 2 E ELEVATION AND ANCHOR LAYOUT 3 E VERTICAL SECTIONS 4 E HORIZONTAL SECTIONS, GLAZING DETAIL & BILL OF MATERIALS 5 E COMPONENTS & CORNER DETAIL ROCUCT RiNEWM 4s eamglyic^, wish the FL.a'Kn _ G�sidimc C.dx 4orcEia):a:No IS 1.O(�5}Sn�T, i1 1i::lf!N% C`w:k f "W DESIGN PRESSURE RATING (PSF) IMPACT RATING i550 LARGE MISSILE IMPACT RW)ed J. Amoroso. P.E. Rodda P.E. No. 49752 No �497 2` 3TAT- OF 'i .�OAlt�1...�� Idfftttlltl��� TREVISE) i.withlht Florida a r 0 m 4 � FLL � 0 0 52' MAX. a a o WIDTH- 6 112- MAX. (TYP.) W 46 3/4" MAX. FROM PARTING 131/2" MAX. 75" D.L.O. STOP CORNERS O.C. (TYP.) MAX. @HEAD & SILL 5 3/4" MAX. FROM FRAME HEIGHT CORNERS (TYP.) _ o 8 S O B D 6" MAX. FROM FRAME g 9! 3 3 CORNERS (TYP.) INSTALLATION pF — — — — — — ANCHOR (TYP.) } z o i,-� a 31r (3 �§,a ��E 141/4"MAX. I �� I y=�=p �W 33314 O.C. I I a d t=i E w z E O (TYP.) O 3" O.C. TYP. FOR a s �'�' z 3 MAX. WOOD SCREWS. w z D.L.O. 4 C 4 I I 4" O.C. TYP, FOR z , - 3 STEEL REINFORCEMENT I / I w o g FIXED W/ (2) EVENLY �� CONCRETE SCREWS, w p F moo o SPACED METAL SCREWS ® g W old 32 3/4" PARTING 45 314" MAX. ANCHOR (TYP.) a MAX. D.L.O. STEEL A X W D.L.O. X �� REINFORCEMENT 131/2" MAX. O.C. (TYP.) ° — — — _ — —Fill Robert J. E N1 , 4 P.E. 9752 1 1/4" X 1/4" WEEP HOME I I 41/2" MAX. FROM e�ypMES���i S"1 I 2 5/8' FROM END (TYP.)® Ia 1/2" MAX. I I PARTING STOP �`O�iQ�CE,7...;•�9`� O.C. (TYP.) t� 11 CORNERS (TYP.) • N4875 RST ELEVATION A ANCHOR LAYOUT ,'`.�s R EXTERIOR VIEW EXTERIOR VIEW eAie ►`����� �DUCr satst'tvt� .� C4,741ap with&C 6Torm, RODUCr REVISED "htin4; Cm4e hmm:poly!,tSadig C.d. 20 Prndic[ WOOD BUCK PROTECTION BY OTHERS 1/4" I W TAPCON A 17 (SEE INST. NOTE 11A) ® INSTALLATION ANCHOR ONE BY WOOD BUCK BY 1 1/2" MIN,® 7/8" MIN. OTHERS (SEE NOTE 5, EDGE DISTANCE ONE BY WOOD EDGE DIST, A SHT. 1) BY OTHERS CONCRETE BY OTHERS ., o v vc • , v 'v v 1 1 /2" MIN. (SEE NOTE 5, SHT. 1) (SEE NOTE 4, SHT. 1) ;` o EMBEDMENT® SHEATHING v '• o Q v BY OTHERS' EXTERIOR FINISH '' v �:a v o BY OTHERS EXTERIOR FINISH 8 X 1 1 2" is #8 X 1 1/2" BY OTHERS W00D SCREW # 16 .Z' 4`'.. WOOD SCREW 19 a< 8 X 1 1/2 " PERIMETER CAULK (] WOOD SCREW BY OTHERS � Qo � 1 /4" MAX. SHIM SPACE PERIMETER CAULK �L tq BY OTHERS C HEIGHT #12 WOOD SCREW A INSTALLATION ANCHOR TWO BY WOOD BY OTHERS (SEE NOTE 4, SHT. 1) 11 1/2 MIN.A 18 #8 X 1 1 W� 1 /41 /4" MAX.i 1 14 14 EXTERIOR 15 `� D / INTERIOR 1 WINDOW 19 4 EXTERIOR 15 INTERIOR HEIGHT 9 19 4 8 9 SEE GLAZING DETAIL 8 L i VERTICAL SECTION (ON SHEET 4) EXTERIOR 10 INTERIOR #8 X 1 1/2" a 18 1 WOOD SCREW E'�j 14 PERIMETER CAULK BY OTHERS 14 U � S X 1 1 2 78 WOOD SCREW EXTERIOR FINISH BY OTHERS CONCRETE BY OTHERS—4.. (SEE NOTE 4, SHT. 1) 'P 1 1 1/2" MIN.® ONE BY W00 . o a ' . �..c EMBEDMENT BUCK BY OTHERS ' d 4G •C .� � G (SEE NOTE 5, SHT. 1) WOOD BUCK PROTECTION 1/4" ITW TAPCON 17 1 1/2" MIN. BY OTHERS (SEE INST. AINSTALLATION ANCHOR EDGE DISTANCE ® NOTE 11A) A VERTICAL SECTION coxcasrEsusw D VERTICAL SECTION WlM09U951RATE VERTICAL SECTION C SASHAiPID�D IL1¢. z 3 y no =¢xFram Z J cly r ui ¢ v ¢ oP oui � 8 a U)> w g w��� to !a � n�9pB RohM J. Arroroso, PE Florida PE No. 49752 No 49752 i, o INTERIOR STATE OF iU FT[+J artily u totsl•Jytag wi101hc Flan ger.:pl�.r,ee Firs /6'09l1 O/yr��y� s4'lali! 9r<Y" lQmz) REVISED g with die l lv.•Ida d' 18.Dt?l ►'3 INTERIOR 1/4" MAX. SHIM SPACE �,,)'WBOOD SM AS CREW REQUIRED \�17101 �lh:�tl " MIN. EMBEDMENT - CONCRETE 14 1" MIN. EMBEDMENT - MASONRLEI Y 1 1/2" MIN. EDGE DISTANCE - CONCRETE • 9 . 2' MIN. EDGE DISTANCE - MASONRY® 9 I uu 9 1/4" ITW TAPCON 7 9 ..Q -9 17 INSTALLATION ANCHOR 12 Q A •V�— CONCRETE OR MASONRY ❑ Q• BY OTHERS O9 . (SEE NOTE 4, SHT. 1) 9 ISOLATION MATERIAL 9" <. • 9 BETWEEN WOOD a BUCK & MASONRY 19 B 15 10 9 -1- ;r " 1-1 a ; • OPENING BY OTHERS ;,rtci i PERIMETER CAULK ONE BY WOOD BY OTHERS BUCK BY OTHERS EXTERIOR FINISH (SEE NOTE 5, SHT. 1) BY OTHERS WINDOW WIDTH 14 18 #8 X 1 1/2" E iTEHL4B WOOD SCREW HORIZONTAL SECTION E CONC12TE/MASONRYSUBSMATS EFS: ENERGI FENESTRATION i�TT 7 OF MATERIALS •ASTM A-Al008A / A109,1� i , RLl ® NO�.IPER CURRENT MO ITEM # DESCRIPTION MATERIAL MANUFACTURER 1 MAIN FRAME WHITE RIGID PVC "EFS 2 FIXED MEETING RAIL WHITE RIGID PVC "EFS 3 SASH & MEETING RAIL WHITE RIGID PVC "EFS 4 PANEL STOP / FRAME COVER WHITE RIGID PVC "EFS 5 SLOPED SILL COVER WHITE RIGID PVC "EFS 8 GLAZING STOP WITH HANDLE WHITE RIGID PVC "EFS 7 GLAZING STOP OPERABLE SASH WHITE RIGID PVC "EFS 8 GLAZING STOP (FIXED FRAME) WHITE RIGID PVC "EFS 9 POCKET INSERT WHITE RIGID PVC "EFS 10 0.270' HIGH CENTER FIN WEATHERSTRIP VINYL — 11 INTERLOCK COVER WHITE RIGID PVC "EFS 12 REINFORCEMENT (SASH)15 GA STEEL ALLOY 100811D10' REGENCY PLUS, INC. 13 REINFORCEMENT (FIXED MEETING RAIL)15 GA STEEL ALLOY 1008/1010' REGENCY PLUS, INC. 14 PARTING STOP WOOD PT SYP G=0,55 MIN. 15 SIKA FLEX 552 SILICONE SILICONE SIKA 16 #12 WOOD SCREW (INSTALLATION ANCHOR) STEEL — 17 1/4-ITW ADVANCED THREADFORM TAPCON STEEL TTW 18 #8 X 1 112' WOOD SCREW STEEL — 19 718' OA INSULATED GLASS SEE GLAZING DETAIL, SHT 4) GLASS- 20 BULB VINYL WEATHERSTRIP VINYL — 21 HURRICANE TILT LATCH 1057 EWXSEE NOTE BELOW) STEEL- ZINC COATED ISO IND 22 ENDUR 9.8 SS SPACER STAINLESS STEEL C 23 GLAZING PAD SETTING 13LOCK-2N8-BK-125-028-M NEOPRENE O E INTERIOR i 4" MAX. SH1M SPACE 18 WOOD SCREW $ SHIM AS A 7 3 10 1 REQUIRED 1 1/2" MIN. a ti 14 EMBEDMENT w U m W � A 7/8" MIN. EDGE DISTANCE as n4. W o 16 #12 WOOD SCREW INSTALLATION ANCHOR y 12 Q TWO BY WOOD ❑ FRAME BY OTHERS o O+R' (SEE NOTE 4, SHT. 1) '' o ONE BY WOOD j+." •' BUCK BY OTHERS > Zm 19 8 15 10 9 (SEE NOTE 5, SHT. 1) SHEATHING BY OTHERS amcj to � `` z� PERIMETER CAULK vi = a =w g �+ z Oaaw❑ � BY OTHERS 14 18 #8 X 1 1/2" a a o� WOOD SCREW >- m z� m WINDOW WIDTH w L) v o e EXTERIOR FINISH O O o .9 8" EXTERIORBY OTHERS �a e v z " gegl F HORIZONTAL SECTION NWo %flp £¢ / �❑ � \ 9 / RobeA J. A" .., P.E FWd, P,E No.49762 QA UiTa'9eeaffiD �o�s : ��ctrvsF v9G ` f 1/2GLASS SITE zC u�Pkni� ' � m No 497 2 6anbz:lwlTte r D / ': ST1TE EXTERIOR \ INTERIOR. _ .�sde Pevclrt.zlCim �''• �( p f• O R 1 Q . Is 7/8" O.A. INSULATED GLASS UNIT CONSISTING OR ® 22 19 EXTERIOR LAMINATED GLASS - (2) 1/8- ANNEALED GLASS W/ 0.090' KURARAY AMERICA INC. TROSIFOL.Q PRODUCrASVOE'D ® INTERLAYER, 0.39- AIRPSACE W/ DESICCANT MATRIX a�comPlyO I the Floes STEEL SPACER, INTERIOR 1/8- TEMPERED GLASS L -0IMIS GLAZING DETAIL r Simi ..,ds Pe:Mnet C MAINFRAME WHITE RIGID PVC 0.070" THK.® Q PANEL STOP FRAME COVER WHITE RIGID PVC / 0.070' THK.® r 9/16" GLAZING STOP FIXED LITE WHITE RIGID PVC 0.070" THK.® IQ FIXED MEETING RAIL WHITE RIGID PVC 0.066" THK.® 2 1/16" ❑ 4- B" 2 3/16-� O SLOPED SILL COVER WHITE RIGID PVC 0.075' THKJr Q POCKET INSERT WHITE RIGID PVC 0.070" THK. B" Q SASH & MEETING RAIL WHITE RIGID PVC 0.070" THK.® 1 5/5" 1 1/2" O6 GLAZING STOP / O GLAZING STOP LIFT HANDLE OPERABLE SASH TES C WHITE RIGID PVC 0.055` THK0.055" THK.® "r 5/16' L U - L _4 1/8" 5/16" 11 INTERLOCK COVER WHITE RIGID PVC 0.075" THK e P1 TILT LATCH 0.697' STEEL -ZINC COATED 0.176' 0.323' S o.3as^ 0.205' wm a 377° 0.709° w 0.186" T p o 0.377" 1.906" 2.260" .622' 0.669° 0 I 0 0.803" 1.067° O m 0.709 1.012 . " 0 8 C LL jT �z 0.544' 0.157"J O of s � > z r¢- in ?V. t:ZzW ¢irri ni=�m ~ WELDED MITERED I ¢ O t CORNER CONSTRUCTION > OF W z ro 4 1 o z W 1-: La � wo 0 WCL r 13/16" g 1" 3.5'O.C. 13/7-i-6-- IrrP.1 Robert J. A-o . P.E. 9/16" 1 1 /8" FlOAtla P.E. Na. 49752 e No d975 .c 12 REINFORCEMENT 13 REINFORCEMENT 1a PARTING STOP STEEL STEEL WOOD SHIM STATE OF . Q 0.050" THICK 0.050" THICK F= 30-50KSI Fy=30-50KSI NOTE: CORNER DETAIL® 1XPTWOODBUCK t� �0R1b•'aN Fu 37.5 - 68.7 KPSI Fu = 37.5 - 68.7 KPSI PARTING STOP EXTERIOR PERIMETER BY OTHERS �'gi�sBa7jyp N t�+°` �- 1 1 /2" TO BE SEALED TO 1X PT WOOD BUCK 15//16" WITH SIKA 551 SILICONE 3/4" IIL Jil plying m PRODUCrxsvtsea -I�A -5/B" $'O 1.�7/16" /4 1$-17t Z i Ea_pinuav ➢at¢ u EU e14cm Miami o&tci d Fa Broward County Fenestration Voluntary Wind Load Chart* Per ASCE 7-10 Method 1, Part 1 and FBC (2017) for Retrofiting in Accordance with Formal Interpretation #5 ® o� v� For Detached One -and Two family dwellings and Multiple Single -Family Dwellings (Townhouses) with Mean Roof Height <- 30 feet Wind 170 mph (3-second gust) / Exposure C** / Kd = 0.85 / Kzt = 1.0 / Pressures are in PSF / Not for use in Coastal (Exposure 'D' areas) F * Using Allowable Stress Design methodology (P = 0.6w) / ** Exposure shall be determined according to ASCE 7-10 Section 26.7.3 (Exposure Categories) ° Effective Location: Mean Roof Height of 15 feet Mean Roof Height of 20 feet Mean Roof Height of 25 feet Mean Roof Height of 30 fe et Wind Area Gable or Hip Roof Zone Zone Zone Zone 1 2 3 1 2 3 1 2 3 1 2 3 (ft2) + I - + - + - + - + - + - + - + - + - + - + - + - 10 Gable/Hip Roof 05 70 (0 to 1.5:12) 16.0 -37.8 16.0 -63.4 16.0 -95.4 16.3 -40.2 16.3 -67.4 16.3 -101.4 17.1 -42.1 17.1 -70.6 17.1 -106.3 17.8 -43.7 17.8 -73.4 17.8 -110.4 20 16.0 -36.8 16.0 -56.7 16.0 -79.1 16.0 -39.1 16.0 -60.2 16.0 -84.0 16.0 -41.0 16.0 -63.1 16.0 -88.0 16.7 -42.6 16.7 -65.6 16.7 -91.5 50 16.0 -35.6 16.0 -47.7 16.0 -57.4 16.0 -37.8 16.0 -50.7 16.0 -61.0 16.0 -39.6 16.0 -53.2 16.0 -63.9 16.0 -41.1 16.0 -55.2 16.0 -66.4 300 16.0 -34.6 16.0 -41.0 16.0 -41.0 16.0 -36.8 16.0 -43.6 16.0 -43.6 16.0 -38.5 16.0 -45.7 16.0 -45.7 16.0 -40.0 16.0 -47.4 16.0 -47.4 10 Gable/Hip 21.8 -34.6 21.8 -60.2 21.8 -89.0 23.1 -36.8 1 23.1 -64.0 23.1 -94.6 24.3 1 -38.5 1 24.3 -67.1 24.3 -99.2 25.2 -40.0 25.2 -69.7 1 25.2 -103.0 20 Roof*** 70 < 9 <- 270 (1.5 to 6:12) 19.9 -33.6 19.9 -55.4 19.9 -83.3 21.1 -35.7 21.1 -58.9 21.1 -88.5 22.1 -37.4 22.1 -61.7 22.1 -92.7 23.0 -38.9 23.0 -64.1 23.0 -96.3 50 17.3 -32.4 17.3 -49.0 17.3 -75.6 18.4 -34.4 18.4 -52.1 18.4 -80.3 19.3 -36.0 19.3 -54.6 19.3 -84.2 20.0 -37.4 20.0 -56.7 20.0 -87.5 100 16.0 -31.4 16.0 -44.2 16.0 -69.8 16.3 -33.3 16.3 -47.0 16.3 -74.2 17.1 -35.0 17.1 -49.2 17.1 -77.8 17.8 -36.3 17.8 -51.1 17.8 -80.8 10 Gable Roof 270 < 0 <- 450 34.6 -37.8 34.6 -44.2 34.6 -44.2 36.8 -40:2 36.8 -47.0 36.8 -47.0 38.5 -42.1 38.5 -49.2 38.5 -49.2 40.0 -43.7 40.0 -51.1 40.0 -51.1 20 33.6 -35.9 33.6 -42.3 33.6 -42.3 35.7 -38.1 35.7 -44.9 35.7 -44.9 37.4 -39.9 37.4 -47.1 37.4 -47.1 38.9 -41.5 38.9 -48.9 38.9 -48.9 50 (6 to 12:12) 32.4 -33.3 32.4 -39.7 32.4 -39.7 34.4 -35.4 1 34.4 1 -42.2 34.4 -42.2 36.0 -37.1 36.0 -44.2 36.0 -44.2 37.4 -38.6 1 37.4 -46.0 1 37.4 -46.0 100 131.4 i -31.4 1 31.4 -37.8 31.4 -37.8 33.3 -33.3 33.3 -40.2 33.3 1 -40.2 35.0 -35.0 35.0 -42.1 35.0 -42.1 1 36.3 -36.3 1 36.3 -43.7 1 36.3 1 -43.7 *** For Hip Roofs with angle > 7 degrees (1.5:12) and 5 25 degrees (5.5:12), Zone 3 shall be treated as Zane 2 (Figure 30.4-2B, Note 7, p. 337) Effective Wind Location Mean Roof Height of 15 feet Mean Roof Height of 20 feet Mean Roof Height of 25 feet Mean Roof Height of 30 feet Zone Zone Zone Zone Area 2 Wall 4 5 4 5 4 5 4 5 + - - + 3r .8 - - + - + - + - + - + - + - 10 20 50 40.2 -43.6 40.2 -53.8 42.1 -45.7 42.1 -56.4 43.7 -47.4 43.7 -58.6 36 33.8 39.3 -37.0 "I 33.8 -4.7 38.3 -41.7 38.3 -50.1 40.2 -43.8 40.2 -52.6 41.8 -45.5 41.8 -54.6 36.0 -39.4 36.0 -45.4 37.7 -41.3 37.7 -47.5 39.2 -42.9 39.2 49.4 100 32.1 -35.3 32.1 -39.3 34.1 �-37.5 .1 -41.7 35.8 -39.4 35.8 -43.8 37.2 -40.9 37.2 -45.5 Soo 28.2 -31.4 28.2 -31.4 29.93. --33.3 31.4 -35.0 31.4 -35.0 32.6 -36.3 32-6 -36.3 Garage Door Wind Loads for a Building with 30-foot Mean Roof Height Exposure C Tables 1609.7(1) & (2), and Section 1609.3.1 aL 2 s 2 r 9 ii 5 �; ''' i 5 ; 4 , $ .., h. "� Gable.Ro. of a, r. 1 )' h _ > a :. HIp RQph Effective Wind Area Roof Angle Wind Load Width Height + - 8 8 0 10 - degrees 35.2 -39.8 10 10 34.1 -38.2 14 14 32.3 1 -36.1 For Effective Wind Areas between those given, values may be interpolated. Otherwise use the value associated with the lower Effective Wind Area. 9 7 > 10 degrees 38.4 -4-3.4-1 End Zone (a) shall be the smaller of 10% of Least Hor. Dist. or 40% of Mean Roof Height (W), but not less than 4% of Least Hor. Dist. or 3 ft. 16 7 36.8 -41.01 Identify the zone per the figure or information by others. Any questionable zone is to be considered the more critical zone. Design is based on the 3-second gust (wind velocity) for Risk Category II (general residential & commercial construction) per FBC 1620.2 Broward. These tables not for use with essential facilities or assembly occupancies. Page 2 of 2 FBC 6th Edition (2017) Formal Interpretation #5 Effective date; January 1, 2018 r � m r U O o � O O Z � i j Storm Tight Windows Inc Gervacio.Gonzals 500 Sw 12t" Ave 10044 S Ocean Dr Unit 401 Dee:rfeld Beach F1 33442 Jenson Beach FI 34957 Alterations to condo 1. 35" x 47" single hung window series 5000 2. 35" x 47" single hung window series 5000 3. 85" x 47" single hung window series 5000 2 1 Bedroom 2 Bedroom 1 . 3 N OA N OA 18-0911.05 =g03 apa Storm Tight Windows: Inc Gervacio Gonzals 500 Sw 12th Ave 10044 S Ocean Dr Unit 401 Deerfeld Beach F1.33442 " Jenson Beach :Fl 34957 2 1 Bedroom 2 Bedroom 1 " Li ✓#j Alterations to condo 1. 35" x 47" single hung window series 5000 2. 35" x 47" single hung window series 5000 3.. 35" x 47" single hung window series 5.000 NOA N OA 18-0911.05 3 �y W CL W U v 8 m ® •' W a