Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Project Information
+ wrightsoft° 317 St.. LUC Project Summary Data: Entire House By: QUICK CALCS, INC. For: WYNNE DEVELOPMENT THE WINDSOR, FT. PIERCE, FL �[ t Notes: Design Information Weather: Fort Pierce, FL, US Winter Design Conditions Outside db Inside db Design TD Summer Design Conditions 42 OF Outside db 70 OF Inside db 28 OF Design TD Daily range Relative humidity Moisture difference Heating Summary Structure 18467 Btuh Ducts 6190. Btuh Central vent (0 cfm) 0 Btuh (none) . Humidification 0 Btuh Piping 0 Btuh Equipment load 24657 Btuh Infiltration Method Construction quality Fireplaces Area (ft2) Volume (ft3) Air change&hour Equiv. AVF (cfm) Simplified Average 0 Heat"753 Cool175% 14741 14741 0.38 0.20 93 49 Heating Equipment Summary Make Carrier Trade CARRIER AIR CONDITIONING Model 25HBC536A*030 AHRI ref 7914585 Efficiency Heating 'input Heating output Temperature rise . Actual airflow Airflow factor Static pressure Space thermostat Capacity balance point = 34 OF Backup: 8.5 HSPF 34600 Btuh @ 47°F 1160 cfm 0.047 cfm/Btuh 0.50 in H2O Input = 7 kW, Output = 23009 Btuh, 100 AFUE 90 OF 75 OF 15 OF 50 % 61 gr/lb Sensible Cooling Equipmentioad Sizing Structure 17655 Btuh Ducts 9340 Btuh Central vent (0 cfm) 0 Btuh (none) Blower 0 Btuh Use manufacturer's data in Rate/swing multiplier Equipment load 0.95 sensible 25645 Btuh Latent Cooling Equipment Load Sizing Structure 2453 Btuh Ducts 2554 Btuh Central vent (0 cfm) 0 Btuh (none) Equipment latent load 5007 Btuh Equipment total load 30652 Btuh Req. total capacity at.0.70 SHR 3.1 ton Cooling Equipment Summary Make Carrier Trade CARRIER AIR CONDITIONING Cond 25HBC536A*030 Coil FX4DN(B,F)037 AHRI ref 7914585 Efficiency 12.0 EER, 15 SEER Sensible cooling 24360 Btuh Latent cooling 10440 Btuh Total cooling 34800. Btuh Actual air flow 1160 cfm Air flow factor 0.043 cfm/Bfuh Static pressure 0.50 in H2O Load sensible heat ratio 0.84 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -a'L 2017-Apr1017:19:28 .+- wrightsoft` Right -Suite® Universal 201717.0.14 RSU08101 Page 1 X�` ...k Calcs%DocumentslWYNNE-THE WINDSOR-REVISED.rup Calc = MJ8 Front Door faces: N - - wrightsoft° Right-JO Worksheet Job: Entire House Date: QUICK CALCS, INC. By: 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772.466-6796 Email: QUICKCALCS@AOL.COM 1 Room name Entire. House MASTER BEDROOM 2 3 Exposed wall Room height 153.0 ft 8.4 ft d 45.0 ft 8.0 ft heattcool 4 5 Room dimensions Room area 1753.0 ft' 1.0 x 280.0 ft 280.0 ft' TY Construction number U-value (Btuh/ft2-°F) Or HTM (Btuh/ft2) Area (ft2) or perimeter (ft) (Btuh) (ft2) oorperimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A4ocs 1A clom 1Ac1om :` 0.143 1.270 1;270 ne..4.00 ne • ne ; . 35 56 35 56' : 2.55 : 70.43 ; 70 48 488 7 16 448 -0 > 0 1795 247 581 1141 488 1151 192 0 t 0 192 0 0 769 . ;0 . 0 489 0 A 11 AAm -c1o: 13A4ocs 1.27.0 0.143 -ne... se 35,56: 4.00 .-4524 2.55 16 64 0 41 ,581 165 : 739, 105 0: 0 0.. 0 6 0 0 0 W L--D 11DO 13A-0ocs :4A5 tom `: 13A�4ocs 1Ac1om 0.390 0143 0:770 0.143 1.270 se. sw-; . sw-, nw nw 10.92 4 00 21.56' 4.00 35.56 1131 : 2.55 r- 27 53 2.55 45.24 23 ;, . 437 41 290 33 23 ' ' ,.396 45 .217 0 248 ...-1584 893 867 1162 257 --1007 .. 1140 551 1478 0 :. 56 ... 0 112 33 0 . .6 .0 79 0 0 ;:- 224, : 0. 318 1162 0 143' - ..: .;'0 202 1478 4A5-2omd 12C -iiA ' . 16A 30md 0.770 0`.091 0.032 nw '.- - 21.56 2`55: 0.90 .36.90 = -'1628 2.32 41 ` 308 1753 0 :. `308 1753 880 784 1571 1505 : .. `:395 4067 0 0: 280 0 ;0. 280 0 ;0 251 0 0. 650 P C F • ' :22Jktpl '': ::: 0:989 - ; 27:69 .. , . 0.00 : - _ 1753 .. . - 10. ` -.4237 : .. .' 0 ' .:.280 :. 45 ' 1246 6 c)AED e)cursion 1360 600 Envelope loss/gain 15594 15385 3970 3561 12 a) Infiltration 2873 810 809 228 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 2 460 0 0 Appliances/other 1000 0 Subtotal Pines 6 to 13) 18467 17655 4779 3789 Less extemal load 0 0 0 0 Less :transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 18467 17655 4779 3789 15 Duct loads 34% 63% 6190 9340 340/o 53% 1602 2005 Total room load 24657 26995 1 1 6380 5794 Air required (cfm) 1160 1160 300 249 Calculations approved byACCA to meet all .� wrightsof - 2017-Apr 10 17:19:28 P. Right -Suite® Universal 2017 17.0.14 RSU08101 Page 1 ..k Calcs\Documents\WYNNE-THE WINDSOR-REVISED.rup Calc = MJB Front Door faces: N -- wrightsoft' RightJ® Worksheet Job: Entire House Date: By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772.466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name WIC M. BATH. 2 Exposed wall 0 ft 7.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 5 Room dimensions Room area 7.0 x 9.0 ft 63.0 ft2 1.0 x 61.0 ft 61.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft2-°F) (Btu 2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross WP/S Heat Cool 6 13A-4ocs 1Ac1om 0.143 .1.270 ne ne. 4.00 3556 2.55 7043. 0 0 0 0 0 0 0 0 56 7 0. 196 247 125 488 1A clom 1,270 ne 35 56 7043 0 0 0 - 0 Or 0 0, 0. 1Ac1om : ' 1.270 me ; 35.56 45.24 U 0 0 0 0 ' 0 . -0 _0 11 s-.: 0.143 se 1 D `. 0.390 se 10.92 11.31 0 U, .. 0'.. 0 0 0 0 Q 0 0 :4A5-2oms.:..- Oi770 sw.' 21.56':..,: .. ." 0 ,.• .- b , 0 0. 0 0. 0, VJ✓ 13A4ocs 1A-clom 0.143 1.270 nw nw 4.00 35.56 255 45.24 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 01 LI—�G 4A5.2omd -.-vc bsw::..;, 0.770 0:091 nw , .- : 21.56 ; 2.55. 36.90 ;' 128 0 0 0 0 0 , - :p 0 p 0 p 0 ,. p 0 0 0 p. 4P < C 16A-30md 0.032 - 0.90 232 63 63 56 146 61 61 55 142 :F.".'-: < _22A•tpl '.. 0:989 . --.. . ..27:69 046 .. 63 0 :: 0 -: . , 0 61 .. .. '.7 194 : '0 6 c)AED excursion -5 -26 Envelope loss/gain 56 141 692 729 12 a) Infiltration 0 0 126 35 b) Ro0m ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal Qines 6 to 13) 56 141 817 764 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 56 141 817 764 15 Duct loads 34o/a 53% 1 19 75 340/a W%l 274 4% Total room load 75 216 1091 1168 Air required (ofm) 4 9 51 50 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wcightsoft• Right -Suite® Universal 2017 17.0.14 RSU08101 2017-Apr-10 1 Page 2 ... k Calcs\Document's\WYNNE-THE WINDSOR-REVISED.rup Calc = MJ8 Front Door faces: N • wr ghtsoft° Right-M Worksheet Job: Entire House Date: QUICK CALCS, INC. By: 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772466-6799 Fax 772-466.6796 Email: QUICKCALCS@,AOL.COM • 1 Room name LAUDRY BEDROOM 2 2 Exposed wall 0 ft 12.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 5 Room dimensions Room area 6.0 x 6.0 ft 36.0 ft2 15.0 x 12.0 ft 180.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuhlft2-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat I Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool ° 6 413&400s 1Ac1om 1A-c1om 0143 1.270 1;270 ne-.4.00. ne ne ; 35 56 . 35 56 2.55 . 70 43 : 70 43 " 0 0 ; ,0 0 0 0 0 0 ` -0 0 0 0 96 0 16 80 " 0 .. 0 319 0. ` 587 203 Q 1151' 11 1A c1om : ' 13A4ocs 1z270 0.143 ne se 35.56 4.00 ' . 45:24 2.55 0 0 0 0 .. 0 0 .0 0 - ". 0 0 0 0 0 V)! Y-p 11DO 13A-0ocs :. 0.390 0:143 se sw` 10.92 4 00 11.31 - 2 55 0 ''. p 0. . , 6 0 .. 0 0 .: 0 0 '. 0 0 , 0 0 ....0.0 0 y! 0 770 . sw 21.56 : " ,27.53 .0 0 p 0 0 0 . 0 .. 0 13A4ocs IA-c1om 0.143 1.270 nw nw 4.00 35.56 2.55 45.24 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4A5-2omd ;92C-0sw 0.770 0.'091 nw . -:.: 21.56 Z55 36.90 " 1:28 0 0 0 0 0 0 0- . 0 0 ::' p 0 . 0 0 p 0 • 0 P. C F _ 16A30md i22Atpl r:. 0.032 0i989 - -.; 0.90 .27.69 2.32 .-1 0.00 36 . 36 36 0 32 , t0 84 . 0 180 - : 180 180 . :;.12 161 332 416 : 0 6 c)AED excursion -3 -60 Envelope loss/gain 32 81 1394 1711 12 a) Infiltration 0 0 216 61 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 32 81 1609 1772 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 6 14 6 14 14 Subtotal 38 95 1615 1786 15 Duct loads 34% 53% 13 50 34% 53% 541 945 Total room load 51 145 2156 2730 Air required (cfm) 21 6 101 117 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. A -Fk wrightsoft' 2017-Apr-10 17:19:28 Right -Suite® Universal 2017 17.0.14 RSU08101 Page 3 ...k Calcs%Documents%WYNNE-THE WINDSOR-REVISED.rup Cale = MJ8 Front Door faces: N - - wrightsoft° Right-M Worksheet Job: Entire House Date: By: QUICK CALCs, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@/10L.COM • 1 Room name DINING/GREAT ROOM KITCHEN 2 Exposed wall 50.0 ft ' 11.0 ft 3 Room height 8.9 ft heal/cool 8.9 ft heaUcool 4 5 Room dimensions Room area 1.0 x 588.0 ft 5W.0 ft2 19.0 x 11.0 ft 209.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/ft2-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 0.143 ne 4 00 2.55 0 0 0 0 0 0 0 0' lXclocs 1A clom 1A-616m. t270 1.270 ne ne.. 35 56 35 56 70.43 : 70.43 0 ; .. 0 0 . 0 0 :0. 0 0 0 .. 0- 0 .0 .0 -0 0 0 11 1Ac1om. 13AAocs 7:270. 0.143 ne-. se 35.56 4.00 45:24 2.55 0 0 0 0 0.:: 0 0. 0 0 0 0 0 11D0_, ,., 13A flocs +. 0.390 0.143 _ se sw4 10.92, 4 00' _ 11.31 } Z65 0 267 0 226 -0 . 903 0 574,98 0 0 ` .. . , 98 0 • 392 0 ; 249' �--D �% c. • r, 4A5.2om: .. 0:770 sw 21.'56 : 27:53 ' 41 . - 22 893 r 1140 - •. 0 _• -0 .-. _ p _ .. -Q .:. 13AAocs ' IA-clom 0.143 1.270 nw nw 4.00 35.56 2.55 45.24 178 0 137 0 549 0 349 0 0 0 0 0 0 0 0 0 P ? 4A5-2omd 12C-0sw :... 0.770 0:09fi mw ,..:=' 21.56. 2:55 36.90 " 1:28 41 0 .. 0 ,. ..0 880 ' 0 1505 0 0 116 0 .. .416 0 ' •295 0 148 C 16A-30md 0.032 - 0.90 2.32 588 588 527 1364 209 209 187 485 F _2'2A--tpl 0:989 ` _:: 2T69 0.00 .588 • . 50 .:1385 0 .: 209. 11 .305 A 6 c)AED ecursion 1004 -64 Envelope loss/gain 5136 5937 1179 818 12 a) Infiltration 1000 282 220 62 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 2 460 0 0 Appliances/other 1 0 1 1000 Subtotal (lines 6 to 13) 6136 6679 1399 . 1880 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 6 14 0 0 14 Subtotal 6142 6693 1399 1880 1151 Duct loads 1 34% 53% 2058 3541 34% 53-/ol 469 995 Total room load 8200 16234 1867 2875 Air required (cfm) ' 386 440 86 124 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -�- wrightsoft' Right -Suite@ Universal 2017 17.0.14 RSU08101 2017-Apr-10 1 Page age 4 ... k.Calcs%DocumentslWYNNE-THE WINDSOR-REVISED.rup Calc = MJ8 Front Doorfaces: N - - wrightsoft° Right-M Worksheet Entire House QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email; QUICKCALCS AOL.COM Job: Date: By: 1 Room name BATH HALL 2 Exposed wall 5.0 ft 0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heattcool 4 Room dimensions 10.0 x 5.0 ft 5.0 x 5.0 ft 5 Room area 50.0 ft2 25.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/1`1:2�-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A� s 0.143 ne 4 00 :_ 2 55 40 40 160 102 0 0 . 0 0 1A�1om 1270 ne 35 56 7043 0 0 0 0 0" 0 0. 0 1A clom °. 1 270 he 35,56 : 70.43 , 0 0 0 0 0 0 :" 0 0. " 1A,c1om . 4i270 ne .. .35.56 ` 45.244 0 0 0 • 0 :. 0- . 0 : 0 ,. 0 11 VJJ t—D 13A4ocs 0.143 se 4.00 2.55 0 0 0 0 0 0 0 0 11DO 0.390 se 1092 11.31 0 0 0 0 0 0. -0 0 AM-0ocs = < 0143 sw':: 4 00 255 0 0 .:. 0 ° .. • 0 0 :. 0 0 ;0 .4A5tom.'', 0.770 sw" 2136 ;• 2753 • 0 °. 0 0 0 '." 0:: . 0 -0; 0 13A4ocs 0.143 nw 4.00 2.55 0 0 0 0 0 0 0 0 IA-c1om 1.270 nw 35.56 45.24 . 0 0 0 0 0 0 0 0 4A5-2omd 0.770 nw 21.56. 36.90 0 0 0 0 0 0 0. 0 P. 12C Osw 0:091. ,. = " 2.55 , ._ 0 0 0 0 0 0 0. C 16A-30md 0.032 - 0.90 2.32 50 50 45 116 25 25 22 58 aF 22A tpl... 0 989 . - :. ".. 27:69 A 00 : 50 5 138 : 0 25 ` .: 0 0 . 0. W. 6 c)AED excursion. -8 -2 Envelope loss/gain 343 5-101 1 221 56 12 a) Infiltration 90 25 0 0 1 -b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal pines 6 to 13) 433 235 22 56 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 6 14 -22 -56 14 Subtotal 439 249 0 0 151 Duct loads 1 340/6 53%1 147 , 132 34/6 53/6 .0 0 Total room load 586 381 0 0 Air required (cfm) 28 16 0 0 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. A—. -F- wrightsoft' 2017-Apr-10 17:19:28 lecA Right -Suite® Universal 2017 17.0.14 RSU08101 Page 5 ... •k Calcs\Documents\WYNNE-THE WINDSOR-REVISED.rup Calc = MJB Front Door faces: N +�- wrightsoft RighW@ Worksheet Job: Entire House Date: By: QUICK CALCS, INC. 317 ST LUCIE LN., FT. PIERCE, FL 34946 Phone: 772466-6799 Fax 772.466-6796 Email: QUICKCALCS@AOL.COM 1 Room name FOYER BEDROOM-3 2 Exposed wall 9.0 ft 14.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 5 Room dimensions Room area 1.0 x 92.0 ft 92.0 ft2 13.0 x 13.0 ft 169.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (13tuh/ft2-"F) (Stuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat I Cool Gross N/P/S Heat Cool I Gross N/P/S Heat Cool 6 136,40cs 0.143 ne .4.00, 2.55 0 0 0 0 104 88 351 223 1Ac1om 1A c1om 1270 1:270 ne ne., 35.56 , 35.56. 70.43 70.43 .0 : 0 0 _ 0 0 0 0 0 0 0 0 0 0 0 0 ' 0; 1 om ;:. 1270 ne ' 35:56' . . 45.24 ". 0 0 . ' . 0 '0 16 ' D : 581 739 11 L-D 13AAocs 0.143 se 4.00 Z55 64 41 165 105 0 0 0 0 11DO 13A flocs . , 0.390 -0.143 se- sw : 10.92 4:00'. 11.31 . _ 2 55 23 8 23 8 248 `- 32 257 ., . , 20 0 8 0 ; 8 0 .; 32 0 20 .4A5 tom 0:770 sw: 21.56' . - 27:53 0 0 . 0 0 0 `0 0 -0 13A4ocs 1A-c1om 0.143 1.270 nw nw 4.00 35.56 2.55 45.24 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4A5-2omd ,12C-0sW,- 0.770 0.091 nw ' ,= - 21.56 2:55 36.90 A:28 0 88 0 88 0 -224 0 113 0 104 0 . - . 904 0 265 0 133 'P ' C 16A-30md 0.032 - 0.90 2.32 92 92 82 213 169 169 151 392 IF 22A=tpl 0.989 : _:.: '• 27.69 ,: ."0.00 92 9 249 ' : ' '0 . 169 14 • 388: _ 0. 6 c)AED excursion -25 -62 Envelope loss/gain 1 1002 684 1768 1456 12 a) Infiltration 162 46 252 71 b) 'Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal pines 6 to 13) 1163 7301 2020 1527 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1163 730 2020 1527 151 Duct loads I 340/o 53%1 390 386 34°/a 530/a 677 808 Total room load 1553 1116 2697 2335 Air required (cfm) 73 48 1 1 127 100 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. c -I- wrigF�tsoftl 2017 Apr 10 17:19:28 .�A Right -Suite® Universal 2017 17.0.14 RSU08101 Page 6 k Calcs\Documents\WYNNE-THE WINDSOR-REVISED.rup Calc = MJ8 Front Door faces: N wrightsoft° Dulct.Systeln Summary Job: a Entire House Bi: QUICK CALCS, INC. 317 ST. LUCIE LN., FT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AQL.COM Project• • For: WYNNE DEVELOPMENT THE WINDSOR, FT. PIERCE, FL External static pressure Pressure losses Available static pressure Supply /: return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 0.50 in.H2O 0 in H2O' 0.50 in H2O 0.250 / 0.250 in H2O 0.273 in/100ft 1160 cfm Cooling 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.273 in/100ft 1160 cfm 183 ft Supply Branch Detail Table Name Design (Btuh) Htg (cfm) Clg (cfm) Design FR Diam (in) H x W (in) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH h 586 28 16 0.372 4.0 Ox 0 VIFx 19.5 115.0 st1 BEDROOM 2 C 2730 101 117 0.384 7.0 Ox 0 VIFx 15.0 115.0 st1 BEDROOM 3 h 2697 127 100 0.353 6.0 Ox 0 VIFx 26.8 115.0 SO DINING/GREAT ROOM C 3411 129 147 0.292 7:0 Ox0 VIFx 36.5 135.0 st2 DININGIGREATROOM-B C 3411 129 147 0.371 7.0 OxO VIFx 19.9 115.0 st1 DINING/GREAT ROOM-C C 3411 129 147 0.278 7.0 Ox 0 VIFx 44.9 135.0 st2 FOYER h 1553 73 48 0.490 4.0 Ox 0 VIFx 7.0 95.0 KITCHEN c 2875 88 124 0.366 6.0 OxO VIFx 21.8 115.0 SO LAUDRY C 145 2 6 0.371 4.0 OxO VIFx 19.9 115.0 st1 M. BATH h 1091 51 50 0.282 6.0 Ox0 VIFx 42.3 135.0 st2 MASTER BEDROOM h 3190 150 124 0.273 6.0 OxO VIFx 48.4 135.0 st2 MASTER BEDROOM -A h 3190 150 124 0.284 6.0 Ox 0 VIFx 40.9 135.0 st2 WIC C 216 4 9 0.292 4.0 Ox0 VIFx 36.0 135.0 st2 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (Cfm) (Cfm) FIR (fpm) (in) (in) Material Trunk st2 Peak AVF 612 . 602 0.273 780 12.0 0 x 0 VinlFlx st1 st1 Peak AVF 1087 1112 0.273 796 16.0 0 x 0 VinlFlx wri htsoft° 2017-Apr-1017:19:29 9 Right -Suite@ Universal 2017 17.0.14 RSU08101 Page 1 ACCK ...k Calcs\Documents\WYNNE-THE WINDSOR-REVISED.rup Cale = MJ8 Front Door faces: N Return Branch Detail Table . Name Grille Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design PR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Math. Trunk rb1 Ox0 1160 1160 0 0 0 0 Ox 0 VIFx wri htsoft° 2017-Apr-1017:19:29 9 Right -Suite® Universal 2017 17.0.14 RSU08101 Page 2 k Calcs\Documents\WYNNE-THE WINDSOR-REVISED.rup Cale = MJ8 Front Door faces: N