Loading...
HomeMy WebLinkAboutBUILDING PERMIT APPLICATIONAll APPLICABLE INFO MUST BE COMPLETED FOR APPLICATION TO BE ACCEPTED Date: 2/8/2022 Permit Number: L A wD- 7-11-` t ry E-MAILED Building Permit Application Planning and Development Services Building and Code Regulation Division 2300 Virginia Avenue, Fort Pierce FL 34982 Phone: (772) 462-1553 Fax: (772) 462-1578 Commercial CBDG Funding PERMIT APPLICATION FOR: Electrical PROPOSED IMPROVEMENT LOCATION: Residential h. Address: 3175 Columbbrina Circle Port Saint Lucie FL 34952 Property Tax ID #: 3421-702-0021-000-2 Lot No. Site Plan Name: Project Name: Robert C Da Block No. DETAILED DESCRIPTION OF WORK: Romex landed on 2pole 20A breaker within 20 space 200A GE 120/240V single phase panel to feed New Mini Split unit in porch. New Electrical Meter Second Electrical Meter (Affidavit required) CONSTRUCTION INFORMATION: Additional work to be performed under this permit — check all that apply: _Mechanical _ Gas Tank —Gas Piping _ Shutters Electric _ Plumbing _ Sprinklers Total Sq. Ft of Construction: Cost of Construction: $ Windows/Doors _ Pond Generator Roof Pitch Sq. Ft. of First Floor: Utilities: —Sewer _Septic Building Height: OWNER/LESSEE: CONTRACTOR: Name Robert C Dav Address:3175 Columbrina Circle Name: James Murray Company:Go Local Electric LLC City: Port Saint Lucie State: EL Zip Code: 34952 Fax: Phone No. 772-336-0177 E- Address: 660 SE Monterev City: Stuart Zip Code: 34994 Fax: Phone No 772-237-2351 Rd State: EL Mail: Fill in fee simple Title Holder on next page (if different from the Owner listed above) E-Mail i nfo aolocalelectric.com o State or County License EC 13010231 If value of construction is 2500 or more, a RLCUKUtu Notice or commencement is requires. If value of HAVC is $7,500 or more, a RECORDED Notice of Commencement is required. SUPPLEMENTAL CONSTRUCTION LIEN LAW INFORMATION: DESIGNER/ENGINEER: _ Not Applicable MORTGAGE COMPANY: _ Not Applicable Name: Name: Address: Address: City: State: City: State: Zip: Phone Zip: Phone: FEE SIMPLE TITLE HOLDER: Name: Address: City: Zip: Phone: _ Not Applicable BONDING COMPANY: Name: _ Address: City: Zip: _ Phone: Not Applicable OWNER/ CONTRACTOR AFFIDVIT: Application is hereby made to obtain a permit to do the work and installation as indicated. I certify that no work or installation has commenced prior to the issuance of a permit. St. Lucie County makes no representation that is granting a permit will authorize the permit holder to build the subject structure which conflicts with any applicable Homeowners Association rules, bylaws or and covenants that may restrict or prohibit such structure. Please consult with your Homeowners Association and review your deed for any restrictions which may apply. In consideration of the granting of this requested permit, I do hereby agree that I will, in all respects, perform the work in accordance with the approved plans, the Florida Building Codes and St. Lucie County Amendments. The following building permit applications are exempt from undergoing a full concurrency review: room additions, accessory structures, swimming pools, fences, walls, signs, screen rooms and accessory uses to another non-residential use WARNING TO OWNER: Your failure to Record a Notice of Commencement may result in paying twice for improvements to your property. A Notice of Commencement must be recorded in the public records of St. Lucie County and posted on the jobsite before the first inspection. If you intend to obtain financing, consult with lender or an attornev before commencine work or recording vour Notice of Commencement. Signature of Contractor - or - Owner Builder as applicable STATE OF FLORIDA St. Lucie COUNTY OF X Sworn to (or affirmed) and subscribed before me of Physical Presence or Online Notarization this8th day of February[ 2o22 by Name of person making statement. Personally Known X OR Produced Identification Typ�ntification Produced (Signature of Notary Public- State f Florida)�.....»� DANIELLE ZIELINSKI Commission No. S*I "* Commission # GG 918121 Expires October 13, 2023 Bonded Thru Troy Fain Insurance 800-385-7019 REVIEWS FRONT ZONING SUPERVISOR PLANS VEGETATION SEA TURTLE MANGROVE COUNTER REVIEW REVIEW REVIEW REVIEW REVIEW REVIEW DATE RECEIVED DATE COMPLETED ev Job Name. Robert Day pr �Tag#,. DAFKIN Submittal Data Sheet FTXB24AXVJU / RXB24AXVJU 2.0-Ton Wall Mounted Heat Pump System J�i=1 J J J�i=1 J J Complete warranty details available from your local dealer or at www.daikincomfort.com. To receive the 10-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Online registration is not required in California or Quebec. If product is installed in a commercial application, limited warranty period is 5 years. Indoor Specifications Airflow Rate (cfm) Cooling Heating H M H M 555 486 580 486 L L 405 405 Sound (dBA) H/M/L 47 / 44 / 41 47 / 44 / 41 Dimensions (H x W x D) (in) 12-5/8 x 46-1/8 x 9-1/2 Weight (Lbs) 31 Outdoor Specifications Compressor Hermetically Sealed Swing Type Refrigerant R-410A Factory Charge (Lbs) 3.20 Refrigerant Oil PVE (FVC50K) Airflow Rate (cfm) Cooling Heating H 1796 H 1796 Sound Pressure Level (dBA) 52 Dimensions (H x W x D) (in) 29-11/16 x 33-11/16 x 12-15/16 Weight (Lbs) 97 Efficiency Cooling Heating SEER 17 HSPF 9 EER 11 COP 3.68 Performance Cooling (Btu/hr) Rated (Min/Max) 21,200 (6,000 — 22,200) Sensible @ AHRI 15,116 Operating Range 507 —115"F Rated Cooling Conditions: Indoor: 80"F DB/67"F WB Outdoor: 95°F DB/75'F WB Heating (Btu/hr) 1: @ 47" Rated (Min/Max) 21,200 (4,100 — 27,300) 2: @ 17" Rated 11,800 3: @ S" 10,381 Operating Range 5"17-65'F 1: Rated Heating Conditions: 2: Rated Heating Conditions: 3: Heating Conditions: Indoor: 70"F DB/60'F WB Outdoor: 47"F D8/43"F WB Indoor: 70"F DB/60"F WB Outdoor: 17"F DB/15"F WB Indoor: 69.8"F DB Outdoor: 5"F WB Electrical 208/60/1 230/60/1 " System MCA 16.2 16.2 System MFA 20 20 Compressor RLA 16 16 Outdoor fan motor FLA 50 .50 Outdoor fan motor W 61 61 Indoor fan motor FLA .24 .24 indoor fan motor W 40 40 MFA: Max. fuse amps MCA: Min. circuit amps (A) FLA: Full load amps (A) RLA: Rated load amps (A) W: Fan motor rated output (W) Piping Liquid (in) 1/4 Gas (in) 5/8 Drain (in) 3/4 Max. Interunit Piping Length (ft) 98.4 Max. Interunit Height Difference (ft) 32.8 Chargeless (ft) 24.6 Additional Charge of Refrigerant (o2/ft) .21 Daikin North America LLC San Felipe, Suite 500 Houston, TX 77056 (Daikin's products are subject to continuous improvements. Daikin reserves the right to modify product design, specifications and information in this data sheet without notice and without incurring any obligations) Submittal Revision Date: March 2021 Page 1 of q tz q 171 I > > « < n w ± � 64 � E? JCL 0 �C-4a2 CD.\ 3 � q � L / k k c CII 3//m ± � \ CO/ r- 0(D Q (G7 V ;P Electrical Load Calculations Job / Customer Robert Day Phone No: 772-336-0177 Fax No: Project: Day Residence Mini Split Add Location: Stuart Existing Service Feeder Size: 2/0 CU Existing Panel Size: 200A Main Breaker Size: 200A Existing Loads: 1,144 Sq. ft. x 3 watts per sq. ft. 1 1 1 1 1 1 New Loads: 25,232 Prepared by: Appliance cir. @ 1500 watts each Laundry cir. @1500 watts each Range @ 8 kw Dishwasher and disposal @1500 watts each Microwave @2000 watts Water heater @ 4.5 kw Tan kless water heater Dryer @ 5 kw Regridgerator @ 1500 watts Bathroom 1 @ 1500 watts Sprinkler Pump Other Other Other Pool pump Pool I ight Heat pump Chlorine generator Air blower Boatlift Other 2pole 20A Mini Split Other Other First 10kw @ 100% Remainder @ 40% A/C heat @ 100% Go Local Electric, LLC Lic# EC13010231 * ER13015152 Number of Breakers: 20 Space 3,432 watts 3,000 watts ------~--- watts 8,000 watts 1,500 watts 1,500 watts 4,500 watts ---~---- watts 5,500 watts 1,500 watts 1,500 watts ----------- watts ---'—'-�-'� watts ---------- watts ----- watts Sub Total 30,432 watts watts watts watts watts watts watts 4,800 watts watts watts 10,000 watts 6,092.8 watts watts Total 4,800 watts Total watts 25,231.99 Divided by 240 volts = 105.13 Amps Vinnie Croddick Date: 2/7/22 660 SE Monterrey Road, Stuart FL 34994; 772-237-2351; info@goiocalelectric.com