Loading...
HomeMy WebLinkAboutAerial Measurement Report10617 Pine Cone Lane, Fort Pierce, FL 34945 Prepared for you by The Exterior Company, Inc. The Exterior Company, Inc. 1200 Corporate Blvd. Suite 20A. Lancaster, PA 17601 tel. email:info@theexteriorcompany.com www.theexteriorcompany.com Precise Aerial Measurement Report Premium Report 2/8/2022 10617 Pine Cone Lane, Fort Pierce, FL 34945 Report: 44294522 © 2008-2022 Eagle View Technologies, Inc. and Pictometry International Corp. – All Rights Reserved – Protected by European Patent Application No. 10162199.3 – Covered by one or more of U.S. Patent Nos. 8,078,436; 8,145,578; 8,170,840; 8,209,152; 8,515,125; 8,825,454; 9,135,737; 8,670,961; 9,514,568; 8,818,770; 8,542,880; 9,244,589; 9,329,749; 9,599,466. Other Patents Pending. Measurements provided by www.eagleview.com www.eagleview.com/Guarantee.aspx In this 3D model, facets appear as semi-transparent to reveal overhangs. PREPARED FOR Contact:TEC Inc Company:The Exterior Company, Inc. Address:1200 Corporate Blvd Suite 20 A Lancaster, PA 17601 Phone:855-766-3264 TABLE OF CONTENTS Images .....................................................................1 Length Diagram .........................................................4 Pitch Diagram ............................................................5 Area Diagram ............................................................6 Notes Diagram ...........................................................7 Penetrations Diagram .................................................8 Report Summary ........................................................9 Total Roof Area =4,979 sq ft Total Roof Facets =10 Predominant Pitch =6/12 Number of Stories <=1 Total Ridges/Hips =227 ft Total Valleys =71 ft Total Rakes =59 ft Total Eaves =314 ft Total Penetrations =12 Total Penetrations Perimeter = 90 ft Total Penetrations Area = 33 sq ft MEASUREMENTS Premium Report 2/8/2022 10617 Pine Cone Lane, Fort Pierce, FL 34945 Report: 44294522 IMAGES © 2008-2022 Eagle View Technologies, Inc. and Pictometry International Corp. – All Rights Reserved – Protected by European Patent Application No. 10162199.3 – Covered by one or more of U.S. Patent Nos. 8,078,436; 8,145,578; 8,170,840; 8,209,152; 8,515,125; 8,825,454; 9,135,737; 8,670,961; 9,514,568; 8,818,770; 8,542,880; 9,244,589; 9,329,749; 9,599,466. Other Patents Pending. PAGE 1 The following aerial images show different angles of this structure for your reference. Top View Premium Report 2/8/2022 10617 Pine Cone Lane, Fort Pierce, FL 34945 Report: 44294522 IMAGES © 2008-2022 Eagle View Technologies, Inc. and Pictometry International Corp. – All Rights Reserved – Protected by European Patent Application No. 10162199.3 – Covered by one or more of U.S. Patent Nos. 8,078,436; 8,145,578; 8,170,840; 8,209,152; 8,515,125; 8,825,454; 9,135,737; 8,670,961; 9,514,568; 8,818,770; 8,542,880; 9,244,589; 9,329,749; 9,599,466. Other Patents Pending. PAGE 2 North Side South Side Premium Report 2/8/2022 10617 Pine Cone Lane, Fort Pierce, FL 34945 Report: 44294522 IMAGES © 2008-2022 Eagle View Technologies, Inc. and Pictometry International Corp. – All Rights Reserved – Protected by European Patent Application No. 10162199.3 – Covered by one or more of U.S. Patent Nos. 8,078,436; 8,145,578; 8,170,840; 8,209,152; 8,515,125; 8,825,454; 9,135,737; 8,670,961; 9,514,568; 8,818,770; 8,542,880; 9,244,589; 9,329,749; 9,599,466. Other Patents Pending. PAGE 3 East Side West Side Premium Report 2/8/2022 10617 Pine Cone Lane, Fort Pierce, FL 34945 Report: 44294522 LENGTH DIAGRAM © 2008-2022 Eagle View Technologies, Inc. and Pictometry International Corp. – All Rights Reserved – Protected by European Patent Application No. 10162199.3 – Covered by one or more of U.S. Patent Nos. 8,078,436; 8,145,578; 8,170,840; 8,209,152; 8,515,125; 8,825,454; 9,135,737; 8,670,961; 9,514,568; 8,818,770; 8,542,880; 9,244,589; 9,329,749; 9,599,466. Other Patents Pending. PAGE 4 Note: This diagram contains segment lengths (rounded to the nearest whole number) over 5.0 Feet. In some cases, segment labels have been removed for readability. Plus signs preface some numbers to avoid confusion when rotated (e.g. +6 and +9). Total Line Lengths: Ridges = 74 ft Hips = 153 ft Valleys = 71 ft Rakes = 59 ft Eaves = 314 ft Flashing = 42 ft Step flashing = 36 ft Parapets = 0 ft 64 4 141+9 5541802 2 14 37132 3 281416 141631 26 14 18S N W E 2022 Eagle View Technologies, Inc., All Rights Reserved. Premium Report 2/8/2022 10617 Pine Cone Lane, Fort Pierce, FL 34945 Report: 44294522 PITCH DIAGRAM © 2008-2022 Eagle View Technologies, Inc. and Pictometry International Corp. – All Rights Reserved – Protected by European Patent Application No. 10162199.3 – Covered by one or more of U.S. Patent Nos. 8,078,436; 8,145,578; 8,170,840; 8,209,152; 8,515,125; 8,825,454; 9,135,737; 8,670,961; 9,514,568; 8,818,770; 8,542,880; 9,244,589; 9,329,749; 9,599,466. Other Patents Pending. PAGE 5 Note: This diagram contains labeled pitches for facet areas larger than 20.0 square feet. In some cases, pitch labels have been removed for readability. Blue shading indicates a pitch of 3/12 and greater. Gray shading indicates flat, 1/12 or 2/12 pitches. Pitch values are shown in inches per foot, and arrows indicate slope direction. The predominant pitch on this roof is 6/12 +6  +6  +6 +6  +6 +6 1 +6  +6  +6 S N W E 2022 Eagle View Technologies, Inc., All Rights Reserved. Premium Report 2/8/2022 10617 Pine Cone Lane, Fort Pierce, FL 34945 Report: 44294522 AREA DIAGRAM © 2008-2022 Eagle View Technologies, Inc. and Pictometry International Corp. – All Rights Reserved – Protected by European Patent Application No. 10162199.3 – Covered by one or more of U.S. Patent Nos. 8,078,436; 8,145,578; 8,170,840; 8,209,152; 8,515,125; 8,825,454; 9,135,737; 8,670,961; 9,514,568; 8,818,770; 8,542,880; 9,244,589; 9,329,749; 9,599,466. Other Patents Pending. PAGE 6 Note: This diagram shows the square feet of each roof facet (rounded to the nearest Foot). The total area in square feet, at the top of this page, is based on the non-rounded values of each roof facet (rounded to the nearest square foot after being totaled). Total Area = 4,979 sq ft, with 10 facets. 851 344 63 1126 344 500 10 410 41 1291 S N W E 2022 Eagle View Technologies, Inc., All Rights Reserved. Premium Report 2/8/2022 10617 Pine Cone Lane, Fort Pierce, FL 34945 Report: 44294522 NOTES DIAGRAM © 2008-2022 Eagle View Technologies, Inc. and Pictometry International Corp. – All Rights Reserved – Protected by European Patent Application No. 10162199.3 – Covered by one or more of U.S. Patent Nos. 8,078,436; 8,145,578; 8,170,840; 8,209,152; 8,515,125; 8,825,454; 9,135,737; 8,670,961; 9,514,568; 8,818,770; 8,542,880; 9,244,589; 9,329,749; 9,599,466. Other Patents Pending. PAGE 7 Note: This diagram also appears in the Property Owner Report. Roof facets are labeled from smallest to largest (A to Z) for easy reference. H D C I E G A F B J S N W E 2022 Eagle View Technologies, Inc., All Rights Reserved. Premium Report 2/8/2022 10617 Pine Cone Lane, Fort Pierce, FL 34945 Report: 44294522 PENETRATIONS NOTES DIAGRAM © 2008-2022 Eagle View Technologies, Inc. and Pictometry International Corp. – All Rights Reserved – Protected by European Patent Application No. 10162199.3 – Covered by one or more of U.S. Patent Nos. 8,078,436; 8,145,578; 8,170,840; 8,209,152; 8,515,125; 8,825,454; 9,135,737; 8,670,961; 9,514,568; 8,818,770; 8,542,880; 9,244,589; 9,329,749; 9,599,466. Other Patents Pending. PAGE 8 Penetrations are labeled from smallest to largest for easy reference. Total Penetrations = 12 Total Penetrations Area = 33 sq ft Total Penetrations Perimeter = 90 ft Total Roof Area Less Penetrations = 4,946 sq ft 2 1 6 11 9 10 8 7 3 12 4 5 S N W E 2022 Eagle View Technologies, Inc., All Rights Reserved. Premium Report 2/8/2022 10617 Pine Cone Lane, Fort Pierce, FL 34945 Report: 44294522 REPORT SUMMARY © 2008-2022 Eagle View Technologies, Inc. and Pictometry International Corp. – All Rights Reserved – Protected by European Patent Application No. 10162199.3 – Covered by one or more of U.S. Patent Nos. 8,078,436; 8,145,578; 8,170,840; 8,209,152; 8,515,125; 8,825,454; 9,135,737; 8,670,961; 9,514,568; 8,818,770; 8,542,880; 9,244,589; 9,329,749; 9,599,466. Other Patents Pending. PAGE 9 All Structures Areas per Pitch Roof Pitches Area (sq ft) % of Roof 1/12 6/12 9.6 4969.1 0.2%99.8% The table above lists each pitch on this roof and the total area and percent (both rounded) of the roof with that pitch. Structure Complexity Simple Normal Complex Waste Calculation NOTE: This waste calculation table is for asphalt shingle roofing applications. All values in table below only include roof areas of 3/12 pitch or greater. For total measurements of all pitches, please refer to the Lengths, Areas, and Pitches section below. Waste %0%2%7%10%12%14%17%22%27% Area (Sq ft)4970 5070 5318 5467 5567 5666 5815 6064 6312 Squares *50.00 51.00 53.33 55.00 56.00 56.66 58.33 60.66 63.33 Measured Suggested * Squares are rounded up to the 1/3 of a square Additional materials needed for ridge, hip, and starter lengths are not included in the above table. The provided suggested waste factor is intended to serve as a guide—actual waste percentages may differ based upon several variables that EagleView does not control. These waste factor variables include, but are not limited to, individual installation techniques, crew experiences, asphalt shingle material subtleties, and potential salvage from the site. Individual results may vary from the suggested waste factor that EagleView has provided. The suggested waste is not to replace or substitute for experience or judgment as to any given replacement or repair work. Penetrations Area (sq ft) Perimeter (ft) 1-5 6-12 1 4 4 10 Any measured penetration smaller than 3.0x3.0 Feet may need field verification. Accuracy is not guaranteed. The total penetration area is not subtracted from the total roof area. Premium Report 2/8/2022 10617 Pine Cone Lane, Fort Pierce, FL 34945 Report: 44294522 © 2008-2022 Eagle View Technologies, Inc. and Pictometry International Corp. – All Rights Reserved – Protected by European Patent Application No. 10162199.3 – Covered by one or more of U.S. Patent Nos. 8,078,436; 8,145,578; 8,170,840; 8,209,152; 8,515,125; 8,825,454; 9,135,737; 8,670,961; 9,514,568; 8,818,770; 8,542,880; 9,244,589; 9,329,749; 9,599,466. Other Patents Pending. PAGE 10 All Structures Totals Total Roof Facets = 10 Total Penetrations =12 Lengths, Areas and Pitches Ridges = 74 ft (3 Ridges) Hips = 153 ft (8 Hips). Valleys = 71 ft (4 Valleys) Rakes† = 59 ft (4 Rakes) Eaves/Starter‡ = 314 ft (9 Eaves) Drip Edge (Eaves + Rakes) = 373 ft (13 Lengths) Parapet Walls = 0 (0 Lengths). Flashing = 42 ft (4 Lengths) Step flashing = 36 ft (8 Lengths) Total Penetrations Area = 33 sq ft Total Roof Area Less Penetrations = 4,946 sq ft Total Penetrations Perimeter = 90 ft Predominant Pitch = 6/12 Total Area (All Pitches) = 4,979 sq ft Property Location Longitude = -80.4341810 Latitude = 27.4170683 Notes This was ordered as a residential property. There were no changes to the structure in the past four years. Online Maps Online map of property http://maps.google.com/maps?f=g&source=s_q&hl=en&geocode=&q=10617+Pine+Cone+Lane,Fort+Pierce,FL,34945 Directions from The Exterior Company, Inc. to this property http://maps.google.com/maps?f=d&source=s_d&saddr=1200+Corporate+Blvd,Suite+20+A,Lancaster,PA,17601&daddr=10617+Pine+ Cone+Lane,Fort+Pierce,FL,34945 S N W E 2022 Eagle View Technologies, Inc., All Rights Reserved.† Rakes are defined as roof edges that are sloped (not level). ‡ Eaves are defined as roof edges that are not sloped and level.