Review Type
DOCUMENTS MISSING
1/25/2016 Comment:
1/29/2016 Comment:
ENVIRONMENTAL REVIEW
Comment:
FRONT COUNTER REVIEW
Comment:
PLANS EXAMINER PLUMBING
2/4/2016 Comment:
PLANS EXAMINER REVIEW
Comment:
2/3/2016
2/3/2016 Comment:
2/3/2016 Comment:
2/3/2016 Comment:
2/3/2016 Comment:
1
Owner(s):
Standard Pacific Of Soth Florida
Block:
Automatic Sprinkler System? No
Fax Number: 813-288-7610
Email: Tcollins@Stanpac.Com
Status Reviewed By Date Started
PENDING Deanna Givens 112512016
VEG PERMIT SENT TO ERD
VEGETATION REMOVAL IN DRAWER UNDER S - NO FEE IS DUE.
COMPLETE Ben Balcer
Date Completed Date Released
1/26/2016 1/26/2016
COMPLETE Deanna Givens 1/25/2016 1/25/2016 1/25/2016
INCOMPLETE Joe Cicio 2/4/2016
PLANS SHOW THE SEWER LINE ON THE FRONT / SEPTIC IS IN THE REAR OF HOME
INCOMPLETE William Durden 2/3/2016
• THE TOTAL MODIFIED LOAD ON THE ENERGY CAL MUST BE LOWER OR EQUAL TO THE TOTAL BASE LINE
LOADS. SEE SECTION R405.3 OF THE 2014 FLORIDA BUILDING CODE ENERGY CONSERVATION FIFTH
EDITION.
AREA WEIGHTED AVERAGE OVERHANG IS INCORRECT. OPEN COURTYARD HAS AN OVERHANG.
ENERGY CALC'S SHOW 17 GLAZED OPENINGS, THERE ARE A TOTAL OF 28 WINDOW OPENINGS,3 FRENCH
DOORS WITH GLAZING, AND 3 SLIDING GLASS DOORS. PLEASE CORRECT.
ENERGY CAL'S SHOW NATURAL GASS WATER HEATER. EA AND E1.1 SHOW ELECTRIC WATER HEATER.
PLEASE CLARIFY
ENRGY CALS SHOW NATURAL GAS WATER HEATER PLEASE SUBMIT GAS LINE SCHEMATIC.
i
Planning&,Development Services REVIEW COMMENTS
Building 4 Code Regulation Division
2300 Virginia Avenue
Fort Pierce, FL., 34982
Phone:(772)462-2172 Fax:(772)462-6443
Page 2
Comment- • PLEASE FURNISH THE MANLIFACTLIRFS TRUSS PI ACFMFNT nRAWINr;R IN nr 1pl Ir.ATF RFVIFWFn ANr)
2/3/2016
APPROVED BY THE DESIGN PERSON OF,RECORD IN ACCORDANCE WITH 61G15-30.005 OF THE FLORIDA
ADMINISTRATIVE CODE
2/3/2016
Comment:
- PLEASE FURNISH TRUSS ENGINEERING IN DUPLICATE PER 107.2.1 OF THE 2014 FLORIDA BUILDING
CODE
2/3/2016
Comment:
PLANS CALL OUT BARRAL TILE ROOF. PRODUCT REVIEW AFFIDAVIT SHOWS FLAT DBL EAGLE TILE.
PLEASE CORRECT.
2/3/2016
Comment:
ENERGY CAL'S SHOE BARRAL TILE. PRODUCT REVIEW AFFIDAVIT SHOWS FLAT DBL EAGLE TILE. PLEASE
CORRECT.
2/3/2016
Comment:
INCORRECT NOA NUMBER SUBMITTED FOR THE GARAGE DOOR. SUBMIT NOA FOR THE GARAGE DOORS
IN DUPLICATE.
2/3/2016
Comment:
170 MPH ENGINEER DESIGN CERTIFICATION REQUIRED FOR THE GARAGE DOOR. PER NOTES ON SHEET
GN.
2/3/2016
Comment:
PLEASE SUBMIT SOIL REPORT. SEE NOTES ON PAGE GN.