Loading...
HomeMy WebLinkAboutRevision (Roof Vent Calculations)\)) I NWI-klf�l OFFICE USE ONLY: DATE FILED: %0�0$0\4�0 REVISION FEE: "15 - C00 4j PERMIT # \<' 0 \ - (3 - RECEIPT # PLANNING & DEVELOPMENT SERVICES BUILDING & CODE REGULATION DIVISION 2300 VIRGINIA AVENUE - FORT PIERCE, FL 34982-5652 (772) 462-1553 APPLICATION FOR BUILDING PERMIT REVISIONS PROJECT INFORMATION 1. LOCATION/SITE Riverbend 1601-0338 ADDRESS: 3005 NW Radcliffe Way Lot 46 2. DETAILED DESCRIPTION OF PROJECT REVISIONS: Roof vent Calculations and Added R-20 Spray foam insulation (see narrative attached) 3. CONTRACTOR INFORMATION: STATE of FL REG./CERT. #: CGC 15 0 6 0 5 2 ST.LUCIE COUNTY CERT. #: BUSINESS NAME: Standard Pacific Homes QUALIFIERS NAME: Scott Harala ADDRESS: 825 Coral Ridge Drive 'CITY: Coral Spring's STATE: Fl ZIP: 33071 PHONE (DAYTIME): 95-4-2-A2-229n FAX: 954-424-8840 4. OWNER/BUILDER INFORMATION: NAME: Standard Pacific Homes ADDRESS: 825 Coral Ridge Drive CITY: Coral Springs STATE: Fl ZIP:. 33071 PHONE: FAX: 954-434-8840 5. ARCHITECT/ENGINEER INFORMATION: NAME: AB Design ADDRESS: 1191 East Newport Center r7M,, CITY: Deerfield Beanh 'PHONE (DAYTIME): 95 -482-0-957 SLCCC: 9/23/09 Revised 04126/2010 .......... A R C H I T E C T S Design Group Inc. October 21, 2016 St. Lucie County Planning & Development Services Building & Code Regulation Division County 2300 Virginia Avenue Fort Pierce, FL. 34982 Attn: Building Plan Examiner RE: Standard Pacific Homes Riverbend Lot 46 Permit No. # BLDG 1601-0338 Dear Sir/Madam, This letter serves as revisions to drawings: 1. Revised home to sealed attic per builder. A. Roof vent calculations crossed off as they are not applicable. See delta 1 on sheet A21). B. Added R-20 spray foam insulation at roof trusses and removed R-30 blown -in insulation at ceiling. See delta 1 on sheets D1 and D2. If you have any questions please contact me at (407) 774-6078. Sincerely, James Cantwell Florida Architect #12079 Po . �9 �t is j 2 1441 N. Ronald Reagan Blvd. • Longwood, FL 32750 • Phone: (407) 774-6078 • Fax: (407) 774-4078 AA0003325 www.abdesigngroup.com r. P FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation Residential Performance Method Project Name: Standard. Pacific RB Yorkshire Lot 46 Builder Name: Standard Pacific Homes Street: ao� N� �i'i�11'- Permit Office: City, State, Zip: Pdrt St. Lucie, FL , J Permit Number: Owner: Standard Pacific Homes Jurisdiction: Design Location: FL, Fort Pierce 1. New construction or existing New (Frorn Plans) 9. Wall Types (3646.5 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.1 3321.00 ft2 b. Frame - Wood, Adjacent R=11.0 325.43 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 4 d. N/A R= ft2 10. Ceiling Types (3675.0 sqft.) Insulation Area 5. Is this a worst case? No a. Cathedral/Single Assembly (Unvented) R=20.0 3675.00 ft2. 6. Conditioned floor area above grade (ft2) 3675 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(639.4 sqft.) Description Area a. Sup: AC 1 , Ret: AC 1 , AH: AC 1 6 360 a. U-Factor: Sgl, U=1.05 280.00 ft2 b. Sup: AC 2 Master Suite, Ret: AC 2 Master Suite, 6 220 SHGC: SHGC=0.28 b. U-Factor: Sgl, U=1.07 201.53 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.30 a. Central Unit 58.5 SEER:14.00 b. Central Unit 17.8 SEER:14.00 c. U-Factor: Sgl, U=0.77 105.00 ft2 SHGC: SHGC=0.22 13. Heating systems kBtu/hr Efficiency d. U-Factor: other (see details) 52.82 ft2 a. Electric Heat Pump 55.5 HSPF:8.20 SHGC: other (see details)- b. Electric Heat. Pump 17.6 HSPF:8.20 Area Weighted Average Overhang Depth: 9.789 ft. Area Weighted Average SHGC: 0.280 14. Hot water systems a. Electric Cap: 80 gallons 8. Floor Types (3675.0 sgft.) Insulation Area EF: 3.100 a. Slab -On -Grade Edge Insulation R=0.0 3675.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 15. Credits Pstat Glass/Floor Area: 0.174 Total Proposed Modified Loads: 96.65. PASS Total Baseline Loads: 100.42 I hereby certify that the plans and specifications covered by Review of the plans and S�TF this calculation are in compliance with the Florida Energy specifications covered by this ��SIiE p Code. Digitally signed by Chris Wldroudt h DN: cn=Chris Wildroudt, c=US, C I calculation indicates compliance 1 1 1j'' S o=Engineered Air, LLC, ou=Sales PREPARED BY: engineering with the Florida Energy Code. Before construction is completed �nd DATE: � /� /i I � r� � . email_Chrisw@engineeredaidlc.� this building will be inspected for �.}�_,�. Date: 2016.10.25 15:26:13-04'00' compliance with Section 553.908 * �' IV I hereby certify that.this building, as designed, is in Florida Statutes. ty. CpDwe ;!!iance with the Florida Energy Code. OWNER/AGENT: BUILDING OFFICIAL: DATE: My DATE: - Compliance requires certification by the air handler unit manufacturerth; certified factory -sealed in accordance with R403.2.2.1. - Compliance requires. an Air Barrier and Insulation Inspection Checklist in test report in accordance with R402.4.1.2. 10/25/2016 3:24 PM EnergyGauge@ USA - FlaRes2014 Section R40: FORM R405-2014 PROJECT Title: Standard Pacific RB Yorkshire Bedrooms: 4 Address Type: Lot Information Building Type: User Conditioned Area: 3675 Lot # 46 Owner: Standard Pacific Homes Total Stories: 1 Block/SubDivision: Riverbend # of Units: 1 Worst Case: No PlatBook: Builder Name: Standard Pacific Homes Rotate Angle: 270 Street: Permit Office: Cross Ventilation: County: St. Lucie Jurisdiction: Whole House Fan: City, State, Zip: Port St. Lucie , Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE / IECC Design Temp Int Design Temp Heating Design Daily Temp v Design Location TMY Site Zone 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_ST_LUCIE_CO_INTL 2 39 90 70 75 722 62 Low BLOCKS Number Name Area Volume 1 Block1 2806 30393.5 2 Block2 869 9272.2 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 AC 1 2806 30393.5 No 5 3 1 Yes Yes Yes 2 AC 2 Master Suite 869 9272.2 No 2 1 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio AC 1 248 ft 0 2806 ft2 ---- 0 0 1 2 Slab -On -Grade Edge Insulatio AC 2 Master Suit 91 ft 0 869 ft2 0 0 1 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Flat tile/slate 3873 ft2 0 ft2 Light 0.5 No 0.5 No 20 18.4 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 No attic Unvented 0 8675 ft2 N N 10/25/2016 3:24 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 5 FORM R405-2014 CEILING # Ceiling Type Space R-Value Area Framing Frac Truss Type 1 Cathedral/Single Assembly (Unvented AC 1 20 2753 ft2 0.05 Wood 2 Cathedral/Single Assembly (Unveldb.0 Master Suit 20 922 ft2 0.05- Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below # Ornt To Wall Type Space R-Vahle Ft In Ft In Area R-11allie Fraction Ah,-;nr Grade% 1 E=>N Exterior Concrete Block - Int Insul AC 1 4.1 13 0 10.67 0 138.7 ft2 0.3 0 0.3 0 2 E=>N Exterior Concrete Block - Int Insul AC 1 4.1 10 0 10.67 0 106.7 ft2 0.3 0 0.3 0 3 E=>N Exterior Concrete Block- Int Insul AC 1 4.1 13 0 10.67 0 138.7 ft2 0.3 0 0.3 0 4 E=>N Exterior Concrete Block - Int Insul AC 1 4.1 12 0 10.67 0 128.0 ft2 0.3 0 0.3 0 5 S=>E Exterior Concrete Block - Int Insul AC 1 4.1 80 0 10.67 0 853.6 ft2 0.3 0 0.3 0 6 S=>E Exterior Concrete Block - Int Insul AC 1 4.1 13.5 0 10.67 0 144.0 ft2 0.3 0 0.3 0 7 W=>S Exterior Concrete Block - Int Insul AC 1 4.1 34 0 10.67 0 362.8 ft2 0.3 0 0.3 0 8 E=>N Exterior Concrete Block - Int Insul AC 1 4.1 20 0 12.67 0 253.4 ft2 0.3 0 0.3 0 9 N=>W Exterior Concrete Block - Int Insul AC 1 4.1 14 0 10.67 0 149.4 ft2 0.3 0 0.3 0 10 N=>W Exterior Concrete Block - Int Insul AC 1 4.1 24 0 10.67 0 256.1 ft2 0.3 0 0.3 0 11 N=>W Garage Frame - Wood AC 1 11 8 0 10.67 0 85.4 ft2 0.3 0.3 0 12 W=>S Garage Frame - Wood AC 1 11 6 0 10.67 0 64.0 ft2 0.3 0.3 0 13 W=>S Exterior Concrete Block - Int InstAC 2 Master 4.1 18 0 10.67 0 192.1 ft2 0.3 0 0.3 0 14 N=>W Exterior Concrete Block - Int InsLAC 2 Master 4.1 50 0 10.67 0 533.5 ft2 0.3 0 0.3 0 15 S=>E Exterior Concrete Block - Int InsLAC 2 Master 4.1 6 0 10.67. 0 64.0 ft2 0.3 0 0.3 0 16 E=>N Garage Frame - Wood AC 2 Master 11 16.5 0 10.67 0 176.1 ft2 0.3 0.05 0.3 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 W=>S Insulated AC 1 None .3 2.7 8 21.4 ft2 WINDOWS Orientation shown is the entered orientation => changed to As Built rotated 270 degrees). / Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 E=>N 1 Metal Low-E Single Yes 0.77 0.22 32.5 ft2 23 ft 0 in 2 ft 0 in None None 2 E=>N 1 Metal Low=E Single Yes 1 0.32 21.3 ft2 23 ft 0 in 2 ft 0 in None None 3 E=>N 2 Metal Low-E Single Yes 0.77 0.22 32.5 ft2 1 ft 4 in 2 ft 0 in None None 4 E=>N 3 Metal Low-E Single Yes 1.07 0.3 16.2 ft2 6 ft 0 in 2 ft 0 in None None 5 E=>N 4 Metal Low-E Single Yes 0.77 0.22 40.0 ft2 8 ft 0 in 2 ft 0 in None None 6 S=>E 5 Metal _ Low-E Single Yes 1.07 0.3 22.7 ft2 1 ft 4 in 2 ft 0 in None None 7 S=>E 5 Metal Low-E Single Yes 1.07 0.3 9.2 ft2 1 ft 4 in 2 ft 0 in None None 8 S=>E 6. . Metal Low-E Single Yes 1.05 0.28 80.0 ft2 18 ft 0 in 2 ft 0 in None None 9 W=>S 7 Metal Low-E Single Yes 1.07 0.3 117.0 ft2 1 ft 4 in 2 ft 0 in None None 10 E=>N 8 Metal Low-E Single Yes 1.05 0.28 128.0 ft2 12 ft 0 in 4.67 ft 0 i None None 11 E=>N 8 Metal Low-E Single Yes 1 0.32 24.9 ft2 1 ft 4 in 1 ft 0 in None None 12 N=>W 9 . Metal Low-E Single Yes 1.05 0.28 72.0 ft2 18 ft 0 in 2 ft 0 in None None 13 N=>W 14' Metal Low-E Single Yes 1.07 0.3 13.7 ft2 1 ft 4 in 2 ft 0 in None None 10/25/2016 3:24 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5 FORM R405-2014 WINDOWS Orientation shown is:the entered orientation => change to As Built rotated 270 degrees). V # Wall Ornt ID Frame Panes NFRC Overhang U-Factor SHGC Area Depth Separation Int Shade Screening 14 15 16 N=>W 14 Metal Low-E Single Yes N=>W 14 Metal Low-E Single Yes S=>E 15 Metal Low-E Single Yes 1.07 0.3 9.2 ft2 1 ft 4 in 2 ft 0 in None 1 0.32 6.7 ft2 1 ft 4 in 2 ft 0 in None 1.07 0.3 13.7 ft2 1 ft 4 in 2 ft 0 in None None None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 640 ft2 640 ft2 78 ft loft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1. Wholehouse Proposed ACH(50) .000343 3305.5 181.47 341.27 .2503 5 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 2 Electric Heat Pump Split Electric Heat Pump Split HSPF:8.2 55.5 kBtu/hr 1 HSPF:8.2 17.6 kBtu/hr 2 sys#1 sys#2 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 2 Central Unit Split Central Unit Split SEER: 14 58.5 kBtu/hr 1800 cfm 0.75 1 SEER: 14 17.8 kBtu/hr 600 cfm 0.75 2 sys#1 sys#2 HOT WATER SYSTEM # System Type SubType. Location EF Cap Use SetPnt Conservation 1 Electric Heat Pump Garage 3.1 80 gal 70 gal 120 deg None - SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector Storage System Model # Collector Model # Area Volume FEF None None ft2 DUCTS / V # ---- Supply ---- ---- Return ---- Air CFM 25 CFM25 Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF HVAC # Heat Cool 1 2 AC 1 6 360 ft2 AC 1 AC 2 Master 6 220 ft2 AC 2 Master 120 ft2 Default Leakage AC 1 (Default) (Default) 80 ft2 Default Leakage AC 2 Maste (Default) (Default) 1 1 2 2 10/25/2016 3:24 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5 FORM R4M-2014 -TEMPERATURES Programable Thermostat: Y Ceiling Fans: Coolin Jan Heating �X� Jan Feb �X� Feb Mar Mar f A r APr f May May X Jun 4 Jun Jul Jul Au rl Aug Se SePOct Oct Nov Xj Nov Dec HDec Ventin [ Jan [ Feb X Mar [X A r [ Ma [ Jun Jul Aug [ Se [X Oct [X Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 . 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78- 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 10/25/2016 3:24 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 5 FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 96 The lower the EnergyPerformance Index, the more efficient the home. Port St. Lucie, FL, 1. New construction or existing New (From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.1 . 3321.00 ft2 b. Frame - Wood, Adjacent R=11.0 325.43 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 4 d. N/A R= ft2 10. Ceiling Types Insulation Area 5. Is this a worst case? No a. Cathedral/Single Assembly (Unvented) R=20.0 3675.00 ft2 6. Conditioned floor area (ft2) 3675 b. N/A R= ft2 7. Windows- Description Area c. N/A R= ft2 a. U-Factor: Sgl, U=1.05 280.00 ft2 11. Ducts a. Sup: AC 1 , Ret: AC 1 , AH: AC 1 R ft2 6 360 SHGC: SHGC=0.28 b. Sup: AC 2 Master Suite, Ret: AC 2 Master Suite, 6 220 b. U-Factor: Sgl, U=1.07 201.53 ft2 SHGC: SHGC=0.30 12. Cooling systems kBtu/hr Efficiency c. U-Factor: Sgl, U=0.77 105.00 ft2 a. Central Unit 58.5 SEER:14.00 SHGC: SHGC=0.22 b. Central Unit 17.8 SEER:14.00 d. U-Factor: other (see details) 52.82 ft2 13. Heating systems kBtu/hr Efficiency SHGC: other (see details) a. Electric Heat Pump 55.5 HSPF:8.20 Area Weighted Average Overhang Depth: 9.789 ft. b. Electric Heat Pump 17.6 HSPF:8.20 Area Weighted Average SHGC: 0.280 8. Floor Types Insulation Area 14. Hot water systems Cap: 80 gallons a. Slab -On -Grade Edge Insulation R=0.0 3675.00 ft2EF: a. Electric 3.1 b. N/A R= ft2 c. N/A R= ft2 b. Conservation features None 15. Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Date: Address of New Home: c�',(,` City/ L Zip:j *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321) 638-1492 or see the EnergyGauge web site at energygauge:com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 10/25/2016 3:24 PM EnergyGauge® USA - FlaRes2014 - Section R405.4.1 Compliant Software Page 1 of 1 Rh ate,R n63 Residential & Light Commercial HVAC Loads Elite Software,Development, Inc. Engineered Air, LLC, • ' ® Cal Atl' RB 6811 Yorkshire Model' Page 2 Project.. Report.: GeneralkPro'ect Information,>. .. g Project Title: Cal Atl RB 6811 Yorkshire Model Designed By: Chris Wildroudt Project Date: 2-13-15 Client Name: CalAtlantic Homes Company Name: Engineered Air LLC CACO45860 Company Representative: Chris Wildroudt Company Address: 2520 N Andrews Ave Ext Company City: Pompano Beach, FL 33064 Company Phone: .954 974-7277 Company Fax: 954 973-1883 Company Comment: - ®esl Reference City: Fort Pierce, Florida Building Orientation: House faces East Daily Temperature Range: Medium Latitude: 27 Degrees Elevation: 25 ft. Altitude Factor: 0.999 Outdoor Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference Winter: 42 39.4 n/a n/a 70 n/a Summer: 90 75 50% 50% 73 46 o- ��.4 Total Building Supply CFM: 2,424 CFM Per Square ft.: 0.660 Square ft. of Room Area: 3,675 Square ft. Per Ton: 645 Volume (ft3) of Cond. Space: 40,884 Bulldin' Loads 4 j =gl ff z>.° Total Heating Required Including Ventilation Air: 53,287 Btuh ; 53.287 MBH4 Total Sensible. Gain: 54,464 Btuh 80 % Total Latent Gain: 13,883 Btuh 20 % Total Cooling Required Including Ventilation Air: 68,347 Btuh 5.70 Tons (Based On Sensible + Latent) `Notes �� ��:, � � � � •,u . w � .; � Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. C:\Chris W Files from Share\Chris Elite Files\Stan Pac RB 6811 Yorkshire.rhg Tuesday, March 22, 2016, 1:31 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Engineered Air, LLC, • 'Margate, Cal At] RB 6811 Yorkshire Model FL 33063 . , Page 3 ..Total Building SummaryLoads Component Area Seii LatSen T6tal. Gain; gGain'Ty Descn tion Quan Loss Gain 1A-rb-o: Glazing -Single pane, operable window, 320 9,408 0 9,252 9,252 reflective, metal frame with break, u-value 1.05, SHGC 0.28 1A-rb-o: Glazing -Single pane, operable window, 364.9 10,927 0 13,113 13,113 reflective, metal frame with break, u-value 1.07, SHGC 0.3 1A-rb-o: Glazing -Single pane, operable window, 21 588 0 519 519 reflective, metal frame with break, u-value 1, SHGC 0.32 11 D: Door -Wood - Solid Core 142.4 1,441 0 1,441 1,441 13A-4ocs: Wall -Block, board insulation only, R-4 board 2316.1 9,272 0 5,815 5,815 insulation, open core, siding finish 12B-Osw: Part -Frame, R-11 insulation in 2 x 4 stud 230.6 335 0 335 335 cavity, no board insulation, siding finish, wood studs 16D-30: Roof/Ceiling-Under Attic with Insulation on Attic 3675.3 3,295 0 3,789 3,789 Floor (also use for Knee Walls and Partition Ceilings), Vented Attic, No Radiant Barrier, Dark Tile, Slate or Concrete, R-30 insulation 22A-pl: Floor -Slab on grade, No edge insulation, no 308 8,526 0 0 0 insulation below floor, any floor cover, passive, light d soil ----- ---._.................................... . - Subtotals for structure: 43,792 0 34,264 34,264 People: 8 2,400 2,400 4,800 Equipment: 7,200 7,200 14,400 Lighting: 550 1,876 1,876 Ductwork: 3,197 833 3,268 4,101 Infiltration: Winter CFM: 205, Summer CFM: 108 6,298 3,450 2,056 5,506 Ventilation: Winter CFM: 0, Summer CFM: 0 0 0 0 0 AED Excursion: ....................._......... .... ............. _...----.... ---.................. ....... -............... --... _.._-..._-.._.-..- --- ........_........_...._..- 0 ------ 0 --- 3,401 - -- ... ._................ 3,401 ......- - -- Total Building Load Totals: 53,287 13,883 54,464 68,347 Check Ei ores k$ F AM in ..< , , Total Building Supply CFM: 2,424 CFM Per Square ft.: 0.660 Square ft. of Room Area: 3,675 Square ft. Per Ton: 645 Volume (ft3) of Cond. Space: 40,884 �Buildin Loads $= K• ., Total Heating Required Including Ventilation Air: 53,287 . Btuh 53.287 MBH Total Sensible Gain: 54,464 Btuh 80 % Total Latent Gain: 13,883 Btuh 20 % Total Cooling Required Including Ventilation Air: 68,347 Btuh 5.70 Tons (Based On Sensible + Latent) Notes Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2; and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. C:\Chris W Files from Share\Chris Elite Files\Stan Pac RB 6811 Yorkshire.rh9 Tuesday, March 22, 2016, 1:31 PM Rhvac - Residential & Light Commercial HVAC Loads Elite Software Development, Inc. Engineered Air, LLC ® Cal Atl RB 6811 Yorkshire Model Margate, FL 33063 Page 4 System. f Room: Load Summa. . "u. �p Room,, a �, � Htg Min r « hRun, p , 4iRun Clg Clg Min ^_ Act tk ., ! "' f :i qi." Z- -•: v�� �. "`, , ' '.Yr. Area , . Sensk Htg �D3uct Duct, }� SensyTLat��Clg rk Sys? . . �Btuh W IVo' Name .......{4 }.;Bfiah .. rCFM'�I ,Size .a ,-Vel _. _ „� t:.. Btuh CFM .CFM ---Zone 1--- 1 Foyer 120 1,312 17 1-4 484 928 99 42 42 2 Dining Room 180 2,572 33 2-6 473 4,081 832 186 186 3 Bed 2 156 3,253 42 1-6 445 1,921 708 87 87 4 Bath 2, Laundry, 312 1,681 22 1-4 655 1,256 332 57 57 Pwdr 5 Bed 3 154 3,308 43 1-6 457 1,972 675 90 90 6 Bath 3 & Bath 4 204 2,778 36 1-6 396 1,710 598 78 78 7 Bed 4 143 1,812 24 1-4 550 1,056 543 48 48 8 Club Room 338 10,073 131 5-6 512 11,038 1,745 502 502 9 Great Room 456 5,405 70 3-6 473 6,127 1,216 279 279 10 Casual Dining 221 5,805 75 3-6 413 5,349 275 243 243 11 Kitchen 308 286 4 2-6 411 3,552 2,300, 162 162 12 Cabana Bath & 243 1,723 22 1-4 667 1,279 565 58 58 Pantry _ Duct Latent 363 Return Duct 1,048 1,055 269 _ System 1 total 2,835 41,059 520-_ _ _- 41,324 _10,519 1,832 1,832 System 1 Main Trunk Size: 14x21 in. Velocity: 897 ft./min Loss per 100 ft.: 0.093 in.wg Coolm eS stemS_umma W �,�, :f 7; . s: ..]S 1 a acme¢-.�,�r �C M'�'nJ6 ilV ...�Yfl. y. 4Aw. FY . b.. W X, �aYr'ss fix" Cooling '' , , Sens b5le/Latenf � % ;ASens blew k Latent r,. Tons,y�,"f �' .Bth` a ,.'Btuh _ frSlitu . _. _ Net Required: 4.32 80% / 20% 41,324 10,519 51,843 C:\Chris W Files from Share\Chris Elite Files\Stan Pac RB 6811 Yorkshire.rh9 Tuesday, March 22, 2016, 1:31 PM Rhvac - Residential & Light Commercial HVAC Loads Elite,Sdftware Development, Inc' Engineered Air, LLC Cal All RB 6811 Yorkshire Model Margate, FL 33068Page 5 System- 2' Room: Load. Suimmor Act Ht 10 Run- Run Cig Min UC "R Seri --- Zone 1-- 13 Master Bath & .432 4.443 58 2'6 443 3.823 1.243174 174 Closets 14 Master Bedroom 408 7671 100 4'8 533 9,195 1,919 418 418 Duct Latent 170 Return Duct 115 123 32 System Main Trunk Size: 9x14 in. Velocity: 677 ft./min � Loss per 1DUfL: ' 0.093 in.wg � | Net Required: 1 13.141 3.364 16.505 | CiChrisVVFiles from Ghare\ChrisElite Files\StonPnoRBG81iYmkshirexhS Tuesday, March 22.2U1G.1:31PM