Loading...
HomeMy WebLinkAboutSoil Nuclear GaugeSoil Nuclear Gauge Report Date: 5/19/2016 Test Method: ASTM D 6938 Port St. Lucie FBPE CA # 4930 521 NW Enterprise Drive Port St. Lucie, FL 34986 Phone: 772-924-35751 Fax: 772-924-3580 RECEIVED MAY 23 2016 W Client: Project: Standard Pacific Homes, South Florida 13-0183.00 825 Coral Ridge Drive Riverbend Coral Springs, FL 33071-4180 St. Lucie County, Florida Test Results Test# Retest Of Test Date ProctorlD Method Soil Classification Optimum Moisture N Maximum Dry Density (pcf) In Place Moisture N In Place Dry Density (pcf) Probe Depth (in) Percent Compaction Min/Max Comp. N Remark 70 5/16/16 P-1 N/A 10.2 116.0 7.7 111.1 12 96 95 / 105 Pass 71 5/16/16 P-1 N/A 10.2 116.0 6.9 114.0 12 98 95 / 105 Pass 72 5/16/16 P-1 N/A 10.2 116.0 8.1 114.9 12 99 95 / 105 Pass Test Information Test # Test Location Elevation Reference Gauge Make / Model / SN Field Technician 70 Below Slab Grade: Lot No. 46, Foundation Pad, Center Area 0-1 Troxler 3430 25093 Baker, Jeff 71 Below Slab Grade: Lot No. 46, Foundation Pad, Southeast Area 0-1 Troxler 3430 25093 Baker, Jeff 72 Below Slab Grade: Lot No. 46, Foundation Pad, Northwest Area 0-1 Troxler 3430 25093 Baker, Jeff Remarks Comments Related Tests Pass: Tests results comply with Specifications Tests are "Direct Transmission" (Method A) unless probe depth is noted as "Backscatter". Gauge calibration data on file with the testing agency. Test # Related Test # Test Type %%t%% 40 onna , I o rEA * 7 5 P 0 Pd W. Mol r, • w 'tssion�l 6'rv�Ine �# 6 2&171orida Test Reports shall not be reproduced, except in full, without the written approval of GFA International Inc. s®y °�j'S �O N ® qV 1 of 1 ti f