HomeMy WebLinkAboutSoil Nuclear GaugeSoil Nuclear Gauge
Report Date: 5/19/2016
Test Method: ASTM D 6938
Port St. Lucie
FBPE CA # 4930
521 NW Enterprise Drive
Port St. Lucie, FL 34986
Phone: 772-924-35751 Fax: 772-924-3580
RECEIVED MAY 23 2016 W
Client: Project:
Standard Pacific Homes, South Florida 13-0183.00
825 Coral Ridge Drive Riverbend
Coral Springs, FL 33071-4180 St. Lucie County, Florida
Test Results
Test#
Retest
Of
Test
Date
ProctorlD
Method
Soil
Classification
Optimum
Moisture
N
Maximum
Dry Density
(pcf)
In Place
Moisture
N
In Place
Dry Density
(pcf)
Probe
Depth
(in)
Percent
Compaction
Min/Max
Comp.
N
Remark
70
5/16/16
P-1
N/A
10.2
116.0
7.7
111.1
12
96
95 / 105
Pass
71
5/16/16
P-1
N/A
10.2
116.0
6.9
114.0
12
98
95 / 105
Pass
72
5/16/16
P-1
N/A
10.2
116.0
8.1
114.9
12
99
95 / 105
Pass
Test Information
Test #
Test Location
Elevation
Reference
Gauge
Make / Model / SN
Field Technician
70
Below Slab Grade: Lot No. 46, Foundation Pad, Center Area
0-1
Troxler 3430 25093
Baker, Jeff
71
Below Slab Grade: Lot No. 46, Foundation Pad, Southeast Area
0-1
Troxler 3430 25093
Baker, Jeff
72
Below Slab Grade: Lot No. 46, Foundation Pad, Northwest Area
0-1
Troxler 3430 25093
Baker, Jeff
Remarks
Comments
Related Tests
Pass: Tests results comply with Specifications
Tests are "Direct Transmission" (Method A) unless probe depth is noted as "Backscatter".
Gauge calibration data on file with the testing agency.
Test #
Related Test #
Test Type
%%t%%
40
onna , I o
rEA * 7 5
P
0
Pd W. Mol r, • w
'tssion�l 6'rv�Ine �# 6
2&171orida
Test Reports shall not be reproduced, except in full, without the written approval of GFA International Inc. s®y °�j'S �O N ® qV 1 of 1
ti
f