HomeMy WebLinkAboutEnergy Efficiency CodeFORM R405-2014
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation Residential Performance Method
Project Name: Standard Pacific RB Yorkshire Lot 46
Builder Name: Standard Pacific Homes
Street: 3cx0.S MW 14Aac I t' Itil
Permit Office:
City, State, Zip: Port St. Lucie , FL ,
Permit Number:
Owner: Standard Pacific Homes
Jurisdiction:
Design Location: FL, Fort Pierce r 4L
1. New construction or existing New (From Plans)
9. Wall Types (3646.5 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Int Insul, Exterior
R=4.1 3321.00 ft2
b. Frame - Wood, Adjacent
R=11.0 325.43 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 4
d. N/A
R= ft2
10. Ceiling Types (3675.0 sqft.)
Insulation Area
5. Is this a worst case? No
a. Under.Attic (Vented).
R=30.0 3675.00 ft2
6. Conditioned floor area above grade (ft2) 3675
b. N/A
R= ft2
Conditioned floor area below. grade (ft2) 0
c. N/A
R= ft2
11. Ducts
R ft2
7. Windows(639.4 sgft.) Description Area
a. Sup: Attic, Ret: Attic, AH: AC 1
6 360
a. U-Factor: Sgl, U=1.05 280.00 ft2'
b. Sup: Attic, Ret: Attic, AH: AC 1
6 220
SHGC: SHGC=0.28
b. U-Factor: Sgl, U=1.07 201.53 ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.30
a. Central Unit
68.5 SEER:14.00
b. Central Unit
17.8 SEER:14.00
c. U-Factor: Sgl, U=0.77 105.00 ft2
-
SHGC: SHGC=0.22
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: other (see details) , 52.82 ft2
a. Electric Heat Pump
55.5 HSPF:8.20
SHGC: other (see details)
b. Electric Heat Pump
17.6 HSPF:8.20
Area Weighted Average Overhang Depth: 9.789 ft.
Area Weighted Average SHGC: 0.280
14. Hot water systems.
a. Electric
Cap: 80 gallons
8. Floor Types (3675.0 sqft-) Insulation Area
EF: 3.100
a. Slab -On -Grade Edge Insulation R=0.0 3676.00 ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
15. Credits
Pstat
Total Proposed Modified Loads: 98.79.
Glass/Floor. Area: 0.174
PASS
'-' SS
Total Baseline Loads: 100.28
/w
y,I hereby certify that the plans and specifications covered by
Review'of the plans and
O4-THE ST.gT�
this calculation are in compliance with the Florida Energy
Code. Digitally signed byChris Wildroudt
specifications covered by this
calculation indicates compliance
DN: cn=Chris Wildroudt, c=US,
Chris
with the Florida Energy Code.
!� 1iifr 4'.. •;;':yip' ;.�.
O
o=Engineered Air, LLC, ou=Sales
PREPARED BY: and Enaineerinc.
Before construction is completed
„
emailChrisw@engineeredairi Ic.
DATE: ., t-corm--=
this building will be inspected for
compliance with Section 553.908
Date:. 201603.2814:40:11-04'00'
I hereby certify that this buildin de ' ned, is in compliance
Florida Statutes.
c4D
with the Florida Energy Code.
WE'�
OWNER/AGENT:
BUILDING OFFICIAL:
DATE: Ito
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.2.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage
test report in accordance with R402.4.1.2.
3/28/2016 2:35 PM EnergyGauge@ USA - FlaRes2014 Section R405.4.1 Compliant SoftwareILE CIO ?I.
Page 1 of 5
FORM R405-2014
PROJECT
Title:
Standard Pacific RB Yorkshir
Bedrooms: 4
Address Type:
Lot Information
Building Type:
User
Conditioned Area: 3675
Lot #
46
Owner:
Standard Pacific Homes
Total Stories: 1
Block/SubDivision:
Riverbend
# of Units:
1
Worst Case: No
PlatBook:
Builder Name:
Standard Pacific Homes
Rotate Angle: 270
Street:
Permit Office:
Cross Ventilation:
County:
St. Lucie
Jurisdiction:
Whole House Fan:
City, State, Zip:
Port St. Lucie ,
Family Type:
Single-family
FL,
New/Existing:
New (From Plans)
Comment:
CLIMATE
IECC Design Temp
Int Design Temp Heating
Design Daily Temp
Design Location TMY Site
Zone 97.5 % 2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL_ST_LUCIE_CO_INTL 2 39 90
70.
75 722
62
Low
BLOCKS
Number
Name Area
Volume
1
Block1 .2806
30393.5
2
Block2 869
9272.2
SPACES
Number
Name Area
Volume Kitchen Occupants
Bedrooms
InfilID Finished Cooled
Heated
1
AC 1 2806
30393.5 No 5
3
1 Yes
Yes
Yes
2
AC 2 Master Suite 869
9272.2 No 2
1
1 Yes
Yes
Yes
FLOORS
#
Floor Type Space
Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab
-On -Grade Edge Insulatio AC
1 248 ft 0
2806 ftz
____
0 0
1
2 Slab -On -Grade Edge Insulatio AC 2 Master Suit 91 ft 0
869 ftZ
___
0 0
1
ROOF
/
Roof Gable Roof
Solar
SA Emitt
Emitt Deck
Pitch
#
Type Materials.
Area Area Color
Absor,
Tested
Tested Insul.
(deg)
1
Hip Flat tile/slate
3873 ftZ 0 ft2 Light
0.5
No 0.6
No 38
18.4
ATTIC
V
Vent
#
Type Ventilation
Ratio (1 in)
Area
RBS IRCC
1
Full attic Vented 150 3675 ftZ
N N
3/28/2016 2:35 PM EnergyGaugeO USA - FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 5
FORM R405-2014
CEILING
# Ceiling Type
Space
R-Value
Area
Framing Frac
Truss Type
1 Under Attic (Vented)
AC 1
30
2753 ft2
0.05
Wood
2 Under Attic (Vented) AC 2 Master Suit 30
922 ft2
0.05
Wood
WALLS
Adjacent
Cavity
Width Height
Sheathing Framing
Solar Below
Space
RAI;ahle
Ft
In Ft In
Area
13--Vallie
Fraction
Absor
Grade%
_ 1
E=>N Exterior
Concrete Block - Int Insul
AC 1
4.1
13
0 10.67 0
138.7 ft2
0.3
0
0.3
0
5 2
E=>N Exterior
Concrete Block - Int Insul
AC 1
4.1
10
0 10.67' 0
106.7 ft2
0.3
0
0.3
0
3
E=>N Exterior
Concrete Block - Int Insul
AC 1
4.1
13
0 10:67 0
138.7 ft2
0.3
0
0.3
0
4
E=>N Exterior
Concrete Block - Int Insul
AC 1
4.1
12
0 10.67 0
128.0 ft2
0.3
0
0.3
0
5
S=>E Exterior
Concrete Block-' Int Insul
AC 1
4.1
80
0 10.67 0
853.6 ft2
0.3
0
0.3
0
6
S=>E Exterior
Concrete Block - Int Insul
AC 1
4.1
13.5
0 10.67 0
144.0 ft2
0.3
0
0.3
0
7
W=>S Exterior
Concrete Block - Int Insul
AC 1
4.1
34
0 10.67 0
362.8 ft2
0.3
0
0.3
0
8
E=>N Exterior
Concrete Block - Int Insul
AC 1
4.1
20
0 12.67 0
253.4 ft2
0.3
0
0.3
0
9
N=>W Exterior
Concrete Block - Int Insul
AC 1
4.1
14
0 10.67 0
149.4 ft2
0.3
0
0.3
0
10
N=>W Exterior
Concrete Block - Int Insul
AC 1
4.1
24
0 10.67 0
256.1 ft2
0.3
0
0.3
0
11
N=>W Garage
Frame - Wood
AC 1
11
8
0 10.67 0
85.4 ft2
0.3
0.3
0
12
W=>S Garage
Frame - Wood
AC 1
11
6
0 10.67 0
64.0 ft2
0.3
0.3
0
13
W=>S Exterior
Concrete Block - Int InS64{C 2 Master
4.1
18
0 10:67 0
192.1 ft2
0.3
0
0.3
0
14
N=>W Exterior
Concrete Block - Int InsiAC 2 Master
4.1
50
0 10.67 0
533.5 ft2.
0.3
0
0.3
0
15
S=>E Exterior
Concrete Block - Int InsiMC 2 Master
4.1
6
0 10.67 0
64.0 ft2
0.3
0
0.3
0
16
E=>N Garage
Frame - Wood AC 2 Master
11
16.5
0 10.67 0
176.1 ft2
0.3
0.05
0.3
0
DOORS
# Ornt
Door Type Space
Storms U-Value
Width
Height
Area
Ft
In
Ft In
1 W=>S
Insulated AC 1
None .3
2.7
8
21.4 ft2
WINDOWS
Orientation shown is the entered orientation => changed to As Built rotated 270 degrees).
/
Wall
Overhang
# Ornt ID
Frame Panes NFRC U-Factor SHGC
Area
Depth
Separation
Int Shade
Screening
1 E=>N 1
Metal Low-E Single
Yes
0.77
0.22
32.5 ft2
23 ft 0 in
2 ft 0 in
None
None
2 E=>N 1
Metal Low-E Single
Yes
1
0.32
21.3 ft2
23 ft 0 in
2 ft 0 in
None
None
3 E=>N" 2
Metal Low-E Single
Yes
0.77
0.22
32.5 ft2
1 ft 4 in
2 ft 0 in
None
None
4 E=>N 3
Metal Low-E Single
Yes
1.07
0.3
16.2 ft2
6 ft 0 in
2 ft 0 in
None
None,
5 E=>N 4
Metal Low-E Single
Yes
0.77
0.22
40.0 ft2
8 ft 0 in
2 ft 0 in
None
None
6 S=>E '5 =
Metal Low-E Single
Yes
1.07
0.3
22.7 ft2
1 ft 4 in
2 ft 0 in
None
None
7 S=>E 5
Metal Low-E Single
Yes
1.07
0.3
9.2 ft2
1 ft 4 in
2 ft 0 in
None
None
8 S=>E 6
Metal Low-E Single
Yes
1.05
0.28
80.0 ft2
18 ft 0 in
2 ft 0 in
None
None
9 W=>S 7
Metal Low-E Single
Yes
1.07
.0.3
117.0 ft2
1 ft 4 in
.2 ft 0 in
None
None
10 E=>N 8
Metal Low-E Single
Yes
1.05.
0.28
128,012
12 ft 0 in
4.67 ft 0 i
None
None
11 E=>N 8
Metal Low-E Single
Yes
1
0.32
24.9 ft2
1 ft 4 in
1 ft 0 in
None
None
12 N=>W 9
Metal Low-E Single
Yes
1.05
0.28
72.0 ft2
18 ft 0 in
2 ft 0 in
None
None
13 N=>W 14
Metal Low-E Single
Yes
1.07
0.3
13.7 ft2
1 ft 4 in
2 ft 0 in
None
None
3/28/2016 2:35 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5
FORM R405-2014
WINDOWS
Orientation shown is the entered orientation => changed to As Built rotated 270 degrees).
V #
Wall
Ornt ID Frame Panes NFRC
Overhang
U-Factor SHGC Area Depth Separation Int Shade
Screening
14
15
16
N=>W 14 Metal Low-E Single Yes
N=>W 14 Metal Low-E Single Yes
S=>E 15 Metal Low-E Single Yes
1.07 0.3 9.2 ft2 1 ft 4 in 2 ft 0 in None
1 0.32 6.7 ft2 1 ft 4 in 2 ft 0 in None
1.07 0.3 13.7 ft2 1 ft 4 in 2 ft 0 in None
None
None
None
GARAGE
#
Floor Area Ceiling Area.
Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
1
640 ft2 640 ft2
78 ft loft 1.
INFILTRATION
# Scope
Method SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50) .000343
3305.5 . 181.47 341.27 .2503 5
HEATING SYSTEM
#
System Type Subtype
Efficiency Capacity Block
Ducts
1
2
Electric Heat Pump Split
Electric Heat Pump Split
HSPF:8.2 55.5 kBtu/hr 1
HSPF:8.2 17.6 kBtu/hr 2
sys#1.
sys#2
'COOLING SYSTEM
#
System Type Subtype
Efficiency Capacity Air Flow SHR Block
Ducts
1
2
Central Unit Split
Central Unit Split
SEER: 14 58.5 kBtu/hr 1800 cfm 0.75 1
SEER: 14 17.8 kBtu/hr 600 cfm 0.75 2
sys#1
sys#2
HOT WATER SYSTEM
#
System Type SubType Location
EF Cap Use SetPnt Conservation
1
Electric Heat Pump Garage
3.1 80 gal 70 gal 120 deg None
SOLAR HOT WATER SYSTEM
"! FSEC
Cert # Company Name
Collector Storage
System Model # Collector Model # Area Volume
FEF
None None
ft2
DUCTS
V #
---- Supply---- --- Return ---- Air CFM 25 CFM25
Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF
HVAC #
Heat Cool
1
2
Attic 6 360 ft2. Attic
Attic 6 220 ft2 Attic
120 ft2 Default Leakage AC 1 (Default) (Default)
80 ft2 Default Leakage AC 1 (Default) (Default)
1 1
2 2
3/28/2016 2:35 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5
FORM R405-2014
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
Cooling[ Jan
[ ]Jan
Feb
Mar
A r
Ma
Jun
[X] Jul
[X AugX]
Se [
] Oct
[ ]Nov
Dec
Heatin
f X Feb
Mar
E
Apr I
May
Jun
rj
[ ]Jul
[ Aug
[ ]Sep
[
]Oct
I
[Xi Nov
Dec
H
Ventin [ lJ Jan
[ Feb
X Mar
[X
A r
Ma
Jun
[ ] Jul
[ ] Au
[ ]
Se [
Oct
[X] Nov
Dec
Thermostat Schedule:
HERS 2006
Reference
Hours
Schedule Type
1
2
— 3
4
5
6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
78
78
78
78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78
78
78
78
78
78
78
78
78
PM
78
78
78
78
78
78
78
78
78
78
78
78
Heating (WD)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
Heating (WEH)
AM _
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
3/28/2016 2:35 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 5