HomeMy WebLinkAboutEnergy Efficiency CodeFORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation Residential Performance Method Project Name: Standard Pacific RB Yorkshire Lot 46 Builder Name: Standard Pacific Homes Street: 3cx0.S MW 14Aac I t' Itil Permit Office: City, State, Zip: Port St. Lucie , FL , Permit Number: Owner: Standard Pacific Homes Jurisdiction: Design Location: FL, Fort Pierce r 4L 1. New construction or existing New (From Plans) 9. Wall Types (3646.5 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.1 3321.00 ft2 b. Frame - Wood, Adjacent R=11.0 325.43 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 4 d. N/A R= ft2 10. Ceiling Types (3675.0 sqft.) Insulation Area 5. Is this a worst case? No a. Under.Attic (Vented). R=30.0 3675.00 ft2 6. Conditioned floor area above grade (ft2) 3675 b. N/A R= ft2 Conditioned floor area below. grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(639.4 sgft.) Description Area a. Sup: Attic, Ret: Attic, AH: AC 1 6 360 a. U-Factor: Sgl, U=1.05 280.00 ft2' b. Sup: Attic, Ret: Attic, AH: AC 1 6 220 SHGC: SHGC=0.28 b. U-Factor: Sgl, U=1.07 201.53 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.30 a. Central Unit 68.5 SEER:14.00 b. Central Unit 17.8 SEER:14.00 c. U-Factor: Sgl, U=0.77 105.00 ft2 - SHGC: SHGC=0.22 13. Heating systems kBtu/hr Efficiency d. U-Factor: other (see details) , 52.82 ft2 a. Electric Heat Pump 55.5 HSPF:8.20 SHGC: other (see details) b. Electric Heat Pump 17.6 HSPF:8.20 Area Weighted Average Overhang Depth: 9.789 ft. Area Weighted Average SHGC: 0.280 14. Hot water systems. a. Electric Cap: 80 gallons 8. Floor Types (3675.0 sqft-) Insulation Area EF: 3.100 a. Slab -On -Grade Edge Insulation R=0.0 3676.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 15. Credits Pstat Total Proposed Modified Loads: 98.79. Glass/Floor. Area: 0.174 PASS '-' SS Total Baseline Loads: 100.28 /w y,I hereby certify that the plans and specifications covered by Review'of the plans and O4-THE ST.gT� this calculation are in compliance with the Florida Energy Code. Digitally signed byChris Wildroudt specifications covered by this calculation indicates compliance DN: cn=Chris Wildroudt, c=US, Chris with the Florida Energy Code. !� 1iifr 4'.. •;;':yip' ;.�. O o=Engineered Air, LLC, ou=Sales PREPARED BY: and Enaineerinc. Before construction is completed „ emailChrisw@engineeredairi Ic. DATE: ., t-corm--= this building will be inspected for compliance with Section 553.908 Date:. 201603.2814:40:11-04'00' I hereby certify that this buildin de ' ned, is in compliance Florida Statutes. c4D with the Florida Energy Code. WE'� OWNER/AGENT: BUILDING OFFICIAL: DATE: Ito DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.2.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. 3/28/2016 2:35 PM EnergyGauge@ USA - FlaRes2014 Section R405.4.1 Compliant SoftwareILE CIO ?I. Page 1 of 5 FORM R405-2014 PROJECT Title: Standard Pacific RB Yorkshir Bedrooms: 4 Address Type: Lot Information Building Type: User Conditioned Area: 3675 Lot # 46 Owner: Standard Pacific Homes Total Stories: 1 Block/SubDivision: Riverbend # of Units: 1 Worst Case: No PlatBook: Builder Name: Standard Pacific Homes Rotate Angle: 270 Street: Permit Office: Cross Ventilation: County: St. Lucie Jurisdiction: Whole House Fan: City, State, Zip: Port St. Lucie , Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE IECC Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site Zone 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_ST_LUCIE_CO_INTL 2 39 90 70. 75 722 62 Low BLOCKS Number Name Area Volume 1 Block1 .2806 30393.5 2 Block2 869 9272.2 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 AC 1 2806 30393.5 No 5 3 1 Yes Yes Yes 2 AC 2 Master Suite 869 9272.2 No 2 1 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio AC 1 248 ft 0 2806 ftz ____ 0 0 1 2 Slab -On -Grade Edge Insulatio AC 2 Master Suit 91 ft 0 869 ftZ ___ 0 0 1 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials. Area Area Color Absor, Tested Tested Insul. (deg) 1 Hip Flat tile/slate 3873 ftZ 0 ft2 Light 0.5 No 0.6 No 38 18.4 ATTIC V Vent # Type Ventilation Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 3675 ftZ N N 3/28/2016 2:35 PM EnergyGaugeO USA - FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 5 FORM R405-2014 CEILING # Ceiling Type Space R-Value Area Framing Frac Truss Type 1 Under Attic (Vented) AC 1 30 2753 ft2 0.05 Wood 2 Under Attic (Vented) AC 2 Master Suit 30 922 ft2 0.05 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space RAI;ahle Ft In Ft In Area 13--Vallie Fraction Absor Grade% _ 1 E=>N Exterior Concrete Block - Int Insul AC 1 4.1 13 0 10.67 0 138.7 ft2 0.3 0 0.3 0 5 2 E=>N Exterior Concrete Block - Int Insul AC 1 4.1 10 0 10.67' 0 106.7 ft2 0.3 0 0.3 0 3 E=>N Exterior Concrete Block - Int Insul AC 1 4.1 13 0 10:67 0 138.7 ft2 0.3 0 0.3 0 4 E=>N Exterior Concrete Block - Int Insul AC 1 4.1 12 0 10.67 0 128.0 ft2 0.3 0 0.3 0 5 S=>E Exterior Concrete Block-' Int Insul AC 1 4.1 80 0 10.67 0 853.6 ft2 0.3 0 0.3 0 6 S=>E Exterior Concrete Block - Int Insul AC 1 4.1 13.5 0 10.67 0 144.0 ft2 0.3 0 0.3 0 7 W=>S Exterior Concrete Block - Int Insul AC 1 4.1 34 0 10.67 0 362.8 ft2 0.3 0 0.3 0 8 E=>N Exterior Concrete Block - Int Insul AC 1 4.1 20 0 12.67 0 253.4 ft2 0.3 0 0.3 0 9 N=>W Exterior Concrete Block - Int Insul AC 1 4.1 14 0 10.67 0 149.4 ft2 0.3 0 0.3 0 10 N=>W Exterior Concrete Block - Int Insul AC 1 4.1 24 0 10.67 0 256.1 ft2 0.3 0 0.3 0 11 N=>W Garage Frame - Wood AC 1 11 8 0 10.67 0 85.4 ft2 0.3 0.3 0 12 W=>S Garage Frame - Wood AC 1 11 6 0 10.67 0 64.0 ft2 0.3 0.3 0 13 W=>S Exterior Concrete Block - Int InS64{C 2 Master 4.1 18 0 10:67 0 192.1 ft2 0.3 0 0.3 0 14 N=>W Exterior Concrete Block - Int InsiAC 2 Master 4.1 50 0 10.67 0 533.5 ft2. 0.3 0 0.3 0 15 S=>E Exterior Concrete Block - Int InsiMC 2 Master 4.1 6 0 10.67 0 64.0 ft2 0.3 0 0.3 0 16 E=>N Garage Frame - Wood AC 2 Master 11 16.5 0 10.67 0 176.1 ft2 0.3 0.05 0.3 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 W=>S Insulated AC 1 None .3 2.7 8 21.4 ft2 WINDOWS Orientation shown is the entered orientation => changed to As Built rotated 270 degrees). / Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 E=>N 1 Metal Low-E Single Yes 0.77 0.22 32.5 ft2 23 ft 0 in 2 ft 0 in None None 2 E=>N 1 Metal Low-E Single Yes 1 0.32 21.3 ft2 23 ft 0 in 2 ft 0 in None None 3 E=>N" 2 Metal Low-E Single Yes 0.77 0.22 32.5 ft2 1 ft 4 in 2 ft 0 in None None 4 E=>N 3 Metal Low-E Single Yes 1.07 0.3 16.2 ft2 6 ft 0 in 2 ft 0 in None None, 5 E=>N 4 Metal Low-E Single Yes 0.77 0.22 40.0 ft2 8 ft 0 in 2 ft 0 in None None 6 S=>E '5 = Metal Low-E Single Yes 1.07 0.3 22.7 ft2 1 ft 4 in 2 ft 0 in None None 7 S=>E 5 Metal Low-E Single Yes 1.07 0.3 9.2 ft2 1 ft 4 in 2 ft 0 in None None 8 S=>E 6 Metal Low-E Single Yes 1.05 0.28 80.0 ft2 18 ft 0 in 2 ft 0 in None None 9 W=>S 7 Metal Low-E Single Yes 1.07 .0.3 117.0 ft2 1 ft 4 in .2 ft 0 in None None 10 E=>N 8 Metal Low-E Single Yes 1.05. 0.28 128,012 12 ft 0 in 4.67 ft 0 i None None 11 E=>N 8 Metal Low-E Single Yes 1 0.32 24.9 ft2 1 ft 4 in 1 ft 0 in None None 12 N=>W 9 Metal Low-E Single Yes 1.05 0.28 72.0 ft2 18 ft 0 in 2 ft 0 in None None 13 N=>W 14 Metal Low-E Single Yes 1.07 0.3 13.7 ft2 1 ft 4 in 2 ft 0 in None None 3/28/2016 2:35 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5 FORM R405-2014 WINDOWS Orientation shown is the entered orientation => changed to As Built rotated 270 degrees). V # Wall Ornt ID Frame Panes NFRC Overhang U-Factor SHGC Area Depth Separation Int Shade Screening 14 15 16 N=>W 14 Metal Low-E Single Yes N=>W 14 Metal Low-E Single Yes S=>E 15 Metal Low-E Single Yes 1.07 0.3 9.2 ft2 1 ft 4 in 2 ft 0 in None 1 0.32 6.7 ft2 1 ft 4 in 2 ft 0 in None 1.07 0.3 13.7 ft2 1 ft 4 in 2 ft 0 in None None None None GARAGE # Floor Area Ceiling Area. Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 640 ft2 640 ft2 78 ft loft 1. INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000343 3305.5 . 181.47 341.27 .2503 5 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 2 Electric Heat Pump Split Electric Heat Pump Split HSPF:8.2 55.5 kBtu/hr 1 HSPF:8.2 17.6 kBtu/hr 2 sys#1. sys#2 'COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 2 Central Unit Split Central Unit Split SEER: 14 58.5 kBtu/hr 1800 cfm 0.75 1 SEER: 14 17.8 kBtu/hr 600 cfm 0.75 2 sys#1 sys#2 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric Heat Pump Garage 3.1 80 gal 70 gal 120 deg None SOLAR HOT WATER SYSTEM "! FSEC Cert # Company Name Collector Storage System Model # Collector Model # Area Volume FEF None None ft2 DUCTS V # ---- Supply---- --- Return ---- Air CFM 25 CFM25 Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF HVAC # Heat Cool 1 2 Attic 6 360 ft2. Attic Attic 6 220 ft2 Attic 120 ft2 Default Leakage AC 1 (Default) (Default) 80 ft2 Default Leakage AC 1 (Default) (Default) 1 1 2 2 3/28/2016 2:35 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5 FORM R405-2014 TEMPERATURES Programable Thermostat: Y Ceiling Fans: Cooling[ Jan [ ]Jan Feb Mar A r Ma Jun [X] Jul [X AugX] Se [ ] Oct [ ]Nov Dec Heatin f X Feb Mar E Apr I May Jun rj [ ]Jul [ Aug [ ]Sep [ ]Oct I [Xi Nov Dec H Ventin [ lJ Jan [ Feb X Mar [X A r Ma Jun [ ] Jul [ ] Au [ ] Se [ Oct [X] Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 — 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM _ 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 3/28/2016 2:35 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 5