Loading...
HomeMy WebLinkAboutFire Prevention Bureau" SAIJYT LUCIE COUNTY FIRE DISTRICT. ` FIRE PREVENTION BUREAU' PERMIT .P ell 11 To,.Whom it may "concern: Permit Number FS-20-06 rt.. Byvhlue of, the provisions of the Saiat Lucie County Fire Preventibo Code. Date- 05-20-2020 i Contractor 13raricking Out lnc Address ' 'i23300 SNt 134 Avenue City Homestead Stag AFL Z'rp 3$032 , 1 Having made application in i lun form, and as the,conditions, surrounding, and arrangements are, In my opinfon,�such that the intent of the code:Uan be observed, authority is hereby given and the PERMIT is Granted for the installation Of. i Fuel Storage with Dispenses Pr90fct Name' SrPI Address ' 01 Qrange Avenue �• - .Cttyferce St4te: = k Zip 3#950 This permit doesnot take the place of any license ,required, by"ia.wand is not transferable. Anychange,in the us6oroccupancy of the premises sbafl require a he permit. Da s Valid : 90 Contractor y Fire ,. . PAatsbal 3'otry J'erger. ." All fire and (i% safety Cori#ractorsashalf� �iregister'eci through Comp nce -" THIS PERMIT'SHALL AT ALL TIMES BE KEPT POSTED ON THE 011EMI51E5 LISTED: ABOVE. r This Permit Install (1) new fuel tank SCOPE OF WORK: 1. Install (1) new 3,000 gal double wall, aboveground, UL 2085, split compartment, ballistic, impact resistant fuel tank (2,000 gal diesel,1,000 gal gas) on new concrete slab 2. Install (2) new Gasboy Astra fuel dispensers (1) diesel, (1) gas & Veeder Root 450 Plus Monitor 3. Connect electric to pumps (explosion proof) (See Page 4) 4. Pressure test piping & place in service FPL St. Lucie Service Center Orange Avenue ------------, I Fence I � One Story ' I � I I Building I N One Story Building FPL I I I I I I , I , � I I I I I I Switch I I I I Yard ul I I I , I Fence ' ng-- Duse I I Trc I Pole Racks I I I I I I I o REVIEWED FOB Asphalt I I I I I I I I I I I 1 I I I I L----------------------------------------------------------------- 100, FPL St. Lucie Service Center Mike Burchell �---� 3301 Orange Avenue P:CC 056810. Scale g 23300 S.W. 134 Ft. Pierce, FL 34947 Homestead, FL; (305) 258-8101 t CODE COMP Light Pole ST. LUCIE COON-1 Y BOCC I I I '�9_;i`rt,. r Fence F%L� �'®� T��a 'r%'x------------------------------� ., Branching Out Inc. -__ , ' 23300 S.W. 134Ave. 34 Homestead, FL 33032 L31 �- g/; jtj (305) 258-8101 () U) Site Drawing Page 1 of 5 0 Gasoline & On -road Diesel Tank 1 Install (1) new 3,000 gallon above ground (1,000 gasoline/2,000 on -road diesel) Metal Products Company, Double Wall UL Listed 2085, 2 hour fire rated, ballistic impact resistant, Steel Tank EQ 342 on new concrete slab. 2 Tank shall be equipped with 7 gallon Remote Fill Box. Interstitial leak detection, placards, tank gauges, anti -siphon valves, emergency vents, and 2" galvanized vents which shall be terminated 12 feet above finished grade. 3 Tank shall have high level alarms set at 90% capacity with Veeder Root 450 console monitoring installed in adjacent Building 4 Product piping shall be 1.5" schedule 40 above ground black steel to diesel dispensers, 1.5" schedule 40 galvanized to gasoline dispenser and 2" above ground black steel for remote fill to diesel and 2" galvanized to gasoline, all piping shall be installed above ground 5 Install two new single product Listed Gasboy Astra, single hose, single product dispensers one diesel and one gasoline all with auto shutoff nozzles, breakaways and 20' of hose. 6 All piping shall be installed per DEP, DERM, NFPA 30 & 30A codes and ordinances. All fuel related equipment shall be FDEP approved. ALL PETROLEUM EQUIPMENT TO BE FDEP APPROVED Diesel is NFPA class II liquid Gasoline is NFPA class I liquid 1 1/2" Schedule 40 Black Steel to diesel & 1 1/2" Schedule 40 galvanized to gas GASBOY ASTRA single product single hose Only one of two dispensers shown for clarity see pg 3 Hose shut off Breakaway Auto Shut Off ELEVATION OF TANK SLAB =18.61 NGVD Remote Fill Rear View Cabinet only Secondary Kruger Emergency Vent Leak for both Detector Anti -Siphon & compartments EQ675 Press. Relief OPW 199SV Primary E Vent To for each of 2 Dispenser i compartments 1 Veeder Root hi -level alarm @ 90% visible to driver EQ 877 On Road Diesel 2,000 gal Red 2 Blue<i Q Yellow Float White ------------------------------------------- Vent Cap 12' above grade 2" galvanized pipe Continuous Hinge 2" Camlock D14, ust Cap + 2" Coupling Locking Hasp 1" Valve 2" Ball Valve 2" Check I Valve Remote Fill Side View Anti -Siphon & Press. Relief OPW 199SV To Dispenser To Remote Fill Vent Cap 12' above grade 2" galvanized pipe Veeder Root 2" Schedule 40 hi -level Black Steel Fill to alarm @ 90% diesel & 2" Schedule visible to driver 40 galvanized to gas EQ 877 only gasoline ♦ / line shown -------------j- ----- ;-------------------L-- Gasoline Drill 1/2" hole at i Primary 1,000 gal Red top of E-vent drop tube 3 Blue 1 0 Yellow i Placards per NFPA No Smoking White Flammable New Concrete 8" Slab with #4 reinforcing 12" O.C. both ways See pg 3 FPL St. Lucie Service Center Mike Surchell PCC 3301 Orange Avenue 2 300 056 S..W.0134 Ft. Pierce, FL 34947 Homestead, FL (305) 258-8101 Drill 1/2" hole at top of drop tube Remote fill box See detail FIEF r� Branching Out, Inc. 23300 S.W.134 Ave. Page 2 of 5 't. Homestead, FL 33032 Tank Detail ®/ (305) 258-8101 3,000 psi concrete #4 reinforcing 12" O. C both ways Slab Detail 4" Sch #40 Steel Pipe filled with concrete Min 48" AGL Painted Caution Yellow 7' concrete -� 1 12" min I� Bollard Detail Follow existing pavement 0 4416*1 0 0 0 o Gauging 0 Ladder o Single Hose 0 0 Gas Boy Gasoline Dispenser 0 New Concrete o Existing Asphalt Fueling Pad 30' 0 —111111110— ❑ Key Card 0 0 Single Hose 0 0 0 0 0 Gas Boy ❑ Diesel 0 0 Dispenser 0 0 0 0 0 0 0 28' It 1W Remote Fill See pg 2 Mike Burchell FPL St. Lucie Service Center PCC 056810. 3301 Orange Avenue 23300 S.W. 134 A Ft. Pierce, FL 34947 Homestead, FL 33 (305) 258-8101 4' Bollards 48" O.C. Existing Pole Racks `� FILE cony �.1.- Z e Branching Out, Inc. :. 13Q 23300 S.W. 134Ave. Tank & Bollards F4��$� Homestead FL 33032 Page 3 of 5 ,: (305) 258-8101 Existing Service Center Bldg Existing Panel A 120/208 volt 200 amp 42 circuit with 20 spare circuits Directional drill (3) 2" conduits power, control & spare, min 24" deep power = (2) #6 thwn cu power + (1) #6 neu + (1) #10 grd control = (1) 6 strand fiber optic SMOSP DBLT N `\\ Existing Ice house E-stop \`\\ & Hi Level ` Alarm , Q t t I t 1 O 4" Bollards 48' 0.. I O Gauging o p Ladder I o 0 I I Single Hose I 0 0 Gas Boy \ Gasoline o Dispenser 0 I I Concrete 0 New 0 Fueling Pat[ Fuel o Key Card ---a►L-a Tank o Single Hose o 0 Gas Boy �` Diesel Dlspelser 0 ` O 0 0 0 0 0 To Fuel Tank Directional Drill (2)1" conduits (1) power & (1) control Power = (4) #12 thwn cu power + (4) #12 neu + (1) #12 grd Control = (1) 6 strand OSB Fiber Optic + (1) Cat-6 OSP cable. ridgid conduit last 10' with seal off at both ends Class 1 Division 1 Explosion Proof Hi -level alarm from Veeder root TLS 450 set @ 90% on Ice House Visible to driver E-stop ---W- > 20' from dispenser but < 100' To Key card @ Fuel tank Ice House Wall Veeder Root New Panel F1 8 circuit 120/240V 2 pole contactor breaks hot & neutral when E-stop pushed To Service Center Bldg Directional drill (3) 2" conduits power, control & spare min 24" deep power = (2) #6 thwn cu + (1) #6 neu + (1) #10 grd control = (1) 6 strand fiber optic New Panel F1 Detail SM OSP DB LT Inside Existing Ice House x FILE Copy FPL St. Lucie Service Center Mike Burchell PCC 056810. :SteVerr�lurst ' : P.E: 128� r _::= Branching Out, Inc. Electric RenateFll see `� 2 3301 Orange Avenue 23300 S.W.134Ave. 23300 W. 1.34�Ave" �- 23300S.W. 134Ave. Homestead, FL 33032 Page 4 of 5 g Ft. Pierce, FL 34947 Homestead, FL 33032 Hornestad,:=FL33032. d(305) 258-8101 (305) 258-8101 (3b5).28-8101 _ . , _ Overturn 3,000 gal Tank 3, 449# 2.92' Additional hold down from anchors (1) 3/4" Hilti expansion bolt each corner min 4" imbed in 3000 # concrete Tensile uplift 13,365 # ea (Hilti,TZ carbon steel Table 3) > 24" to edge and between anchors FPL St. Lucie Service Center 3301 Orange Avenue Ft. Pierce, FL 34945 • 3,000 Gallon UI 2085 Metal Products Double wall Gas/Diesel Tank Empty Weight 12, 000# ASCE 7-10 Chapter 29 Risk Catagory III (storage of fuel) Figure 26.5:1.c;cafagory I Use 186 mph Wind Directionality Factor = 0.85 (table 26.6-1) Exposure Catagory D (26.7.3) Topographic Factor N/A (no hills) Gust Effect Factor 0.85 (26.9.1) Velocity Pressure Exposure Coefficient table 29.3-1 Velocity Pressure = 0.00256 K K K (V V) =.00256(0.85)(1.0)(1.0)(186)(186) = 75.2 lb sq ft Force coefficient figure 29.5-1 (smooth & round) use h/D of 1 = 0.5 Lateral Force (29.5) F = q(G)(C)(A) = 75.2#/sq ft(0.85)(0.5)(107.9 sq ft) = 3,449 Ibs Vertical Force is the same as lateral force since the projected area of the tank is the same (horizontal round tank) Overturn Calculations 3,000 gal Tank Turning Moment = total wind force @ center of tank = 3,449 # x 2.92 ft = 10,071 ft# Resisting Moment = tank wt x 2.92' =12,000# x 2.29 ft = 35,040 ft # Conclusion: Tank will not overturn using only tank wt. Mike Burchell PCC 056810 23300 SW 134 Ave Homestead, FL 33032 305-258-8101 tk FILE COPY Branching Out Inc, Page 5 of 5 23300 SW 134 Ave Over Turn Homestead, Florida 33032 Calculations 305-258-8101