Loading...
HomeMy WebLinkAboutBuilding Plan 5-5-20Q f0 R v C N Q CV v at W x O V, v: w 0_' U Z 0 O Of OL d w 0_' a C N c 04 Q Q Q N C N C C c C N a c C c K, al w C C a: a O 22 CONCRETE REMOV, I shay 8 `i. Scale: N.T.S. REPAIR Scale: N.T.S. INSPECTION & REPAIR OF REINF. STEEL Scale: N.Y.S. STACK 1 STACK STACK STACK 7 STACK STACK STACK 4 STACK STACK 2�' ®. STACK 1 \ 107 1 1 F070 1 F070 1 1 F070 1 F070 1 1170inI M i ■�7►I1 FFi70 CON WINDOWS ELEVATION VIEW (FACING W/yES0 ��/T) NVI 1�/VSCAM STAIR ELEVATOR STAIR WALKWAY WALKWAY 10 BALCONY 9 BAL(xw 8 BALCM 7 BALCONY 6 BALWIIY 5 BALCONY 4 BAIAONY 3 BAL]DNY 2 BARONY BALCONY EXISTING CONCRETE BALCONY ABOVE 4" x 4" WOOD ABOVE POST TO SPREAD THE LOAD ACROSS THE CEILING SURFACE 6" x 6" TOP AND BOTTOM PLATE POST SHORE (7K CAPACITY) 2" x 8" WOOD BELOW POST TO SPREAD THE LOAD ACROSS THE FLOOR SURFACE EXISTING CONCRETE BALCONY FLOOR SHORING ELEVATION VIEW N.T.S. OCEANRISE PLAN VIEW NOT TO SCALE WHEN CONCRETE IS TO BE REPLACED, SHORING TO BE ADDED UNDER THE FORM BOARDS WITH SPACING 0 72" O.C. HOWEVER, IF ENTIRE DECK IS TO BE REPLACED, CONTRACTOR IS TO CONSULT ENGINEER OF RECORD FOR FURTHER INSTRUCTIONS ON SHORING REQUIREMENTS. LIVING ROOM LOCATE POST SHORES ADJACENT TO AREA OF REPAIR WITH MAX. 72" O.C. SHORING DIAGRAM `AREA OF AS B REPAIR 0 STACK 1 TYPICAL ARRANGEMENT OF BALCONY SITE A' Scale: N.T.S. L14wLn I� W �O WZ_ ~ J z Z J 6 N Z f�_11 N M Q H—I O U ~ J }J ma tI�I x p E---/'� �< }w [ 7 w V1 z 00 vi ¢ mF }� W w ¢m r z Zm w00 y 00 0 � w¢p x- oo LL I FJ� V Z z E a w o 4[/�/� rD•�J� i � a o I�� f-I REVIPWIED FOR =a ms n r l _ CODE �.���'��°LIANCE Z 2 Now U O C o wza So> W woo 0 6 d } a U 4 o T O W O Z UZF Q p � \✓ o E—I wZ, Vi z- z o F>w w0 Z Qom p a�0 ST. Lucie COuntY, Permitting < < WI F M\J�RS, P.E. , > �\\\\\PM J AT,S CONCRETE RESTORATION TO FOLLOW GUIDELINES AS SPECIFIED WITHIN zw \� ,1'� ENS SUBMITTED LETTER DATED MARCH 3, 2020 BY MATHERS ENGINEERING <�rp I CORPORATION. R�<< �z STATE OF :4 p o ALLERESTORATION WORK TAKING PLACE ON SITE CONSISTS OF =o� REPLACING DETERIORATED REBAR WITH EQUIVALENT REBAR Sao SIZES, SHAPES, ETC... ALL REINFORCEMENT BEING REPAIRED IS u" REPLACED WITH A REBAR OF THE SAME SIZE (I.E. 5/8' o ORIGINAL = 5/8' STEEL REPLACEMENT) USE CHROMAX 9100 =<z GRADE 100 KSI (MMFX STEEL REBAR), OR AS MODIFIED HY d w ENGINEER OF RECORD, in w ';Two SIZE OF REPAIRS FOR CONCRETE REPAIRS WILL VARY AND BE .�o DETERMINED AFTER INITIAL DEMOLITION HAS TAKEN PLACE. Eww N m pLV THIS PLAN SHOWS CURRENT LOCATIONS OF WHERE MAINTENANCE 0o1 AND/OR WORK IS TO HE PERFORMED BY CONTRACTOR, AS —BUILT wow DRAWING TO BE PROVIDED PRIOR TO CLOSE OUT, SHOWING TYPE �zl OF REPAIR & LOCATION nF REPAIR FOR EACH BUILDING, o,U F LUCIE COUNTY BUILDING DEPARTMENT PERMIT # 2003-0509 woo U U K Fwd ZW, w w 0 Q ON ww� dw Q0o w Z SwF 02U DRAWN H.S.D. CHECKED W.J.M. DATE MARCH 3, 2020 SCALE NOT TO SCALE JOB NO. 3599-01 SHEET FILE O f Py