HomeMy WebLinkAboutFloor PlanEXISTING
MASTER
BEDROOM
Replace
EXISTING
Tub
w/ NEW
Shower
1%
10
Remove EXISTING Lighting
\
Circuits and Switches
to Remain r�
Remove
°��--
EXISTING
Door
Jam_ UAL —
J
o
EXISTING
1 KITCHEN
EXISTING
EXISTING
Remove EXISTING
Brfold Doors \o
EXISTING
LIVING
ROOM
EXISTING
DINING
EXISTING
BEDROOM 43/DEN
EXISTING
BEDROOM
42
DEMOLITION PLAN
SCALE 1/4" = 1'-0"
4' concrete Bleb repay
with fiber-wx
Existing slab
6 mil vapor
barrier
cold joint
Existing slab
v v v
-- --� —� � New fill
II New plumbing pipe
= or electrical conduit etc...
9
Slab Repair _ Detai
nLs
Remove EXISTING
Sink and Toilet
Install NEW
SCOfE OF WORK:
Remodel Master Bathroom
Remodel Bathroom 1*2
Replace Interior Doors Throughout
Change Master Bath Lighting
No NEW A/C space
Electrical SL,Mbol Legend
$
Single Pole Batch
Ceiling Mounted Light
Sy
Double Pole Switch
Wall Mounted Light
p. F
Waterproof, ground ►atilt interrupts
drywa
2" x 4" top plate tru s bottom cord iling on
1/2" drywall on
2" x 4 studs at IL" o.c.
Finish to match emstmg
rw base -board
match existing profile lu
\ J 2" x 4" P.T. bottom plate
existing slab
Interior Non -Bearing Partition
Scale: 1/2" = 1'-0"
,gypsum wallboard
wood casing
� ' r �2"x4" Wood Buck
Note:
all doors
to be prehung
Typical Interior Door Detail
gypsum wallboar(
reinforce corns
metal top trac
bi-fold d
2"x4" Wood Buck
dote:
io track B bottom
)f door, use fir.
)racket 5 pivot
wood Casing
gypsum wallboard
_reinforce corners
:23 obi -fold door
Jamb 2"x4" Wood Buck
Typical BI-l=old Door Detail
NEW Shower �`EW Swing Door
0
-4"
v J!L
� Y
NEW
W.I.C.
LL
w
iY
NEW"
Brfold
NEW Swing Door
0�
ISTING
KI TCHEN
ISTING
EXISTING
ry ISTING
LIO G
0
NEW Swing Door
XISTIN
iNING
L•—��•
1�,,NEW Swing Doors
NEW Sink
and Toilet
D
E TING
QED OOM
4
REPLACE ALL EXISTING Interior
Doors w/ NEW Owner —specified
Doors — Field Verify ALL Door sizes
PRIOR to ordering
FLOOR PLAN w/ ELECTRIC
TYPICAL NOTES: SCALE I/4" = I'-O"
1. Contractor to verirg ALL notes and dimensions prior to proceeding with work
2. Contractor to STRICTLY enforce ALL OSHA Requirements.
3. No dissimilar metals to touch.
4. Drywall at ceilings shall be leveled and attached to bottom chord
of trusses with screws per FBC R102.3,5.
5. ALL wood in contact with concrete shall be pressure treated.
6. ALL wall dimensions are nominal and not finished wall or stud dimensions.
1. ALL plumbing fixtures to be low flow.
8. Wall and Ceding shall have a flame -spread classification of not greater than
200 per FBC R302.9.1
9. Wall and telling finishes shall have a smoke -developed Index of not greater
than 450 per FBC R302.9.2
10. ALL ceramic the surfaces Installed shall conform to ASTM A108.1 thru A108.6,
A108.1, A118.1, A118.3, A136.1 and A131.1
11. Cement, fiber -cement or glass mat gypsum backers in accordance with ASTM
C1288, C1325, OR C1118 and Installed I.A.W. manufacturers recommendations shall
be used as backer for the wall the in tub areas and wall panels in shower areas.
ELECTRIC NOTES:
12. Use copper wire only, no aluminum.
13. Contractor to verify location of electrical service and provider
14. All NEW branch circuits that supply 125v single phase 15 amp or 20 amp outlets
shall be protected by combination -type AFCI Circuit Breakers.
15. ALL new receptacles to be Tamper resistant AFCI.
WALL SYMBOL LEGEND
= EXISTING Walla - Size Varies" - FAR
= NEW 2" x 4" non -bearing stud walls - see sections. Insulate 304. E CC)LIANCE
with R-II batts at bathrooms 4 between A/C and T. �.UCIE COUNTY
Non -A/C spaces BUCC i,f 2.111, ,U
O
tT
l-
c+l
el
m
oc �
a <
3
Q I q ��
Q to Z
D U >
Ill
Q
Q�
ILI
� O
�!! _
z
o Lo
� � O
� � N
o �
> N
o �
� � v
(Y 4
tr
Q- OL W o p
W =3 " O
dl
W to
Z 00
Qa�io m - Q
IL j aro aro ` #
I z ntti�
to O
~ O rr-rr- tr
�LUU...3v
to ~ W �X6i _J
LL 2 to I- u_
U-
fa U
4in
3
SHEET NO:
l .
OF I.
JOB NUMBER:
20-18
o p aL . %�� o