Loading...
HomeMy WebLinkAbout5bd (2)Envelope leakage Test Report we(Blower Door Test) R405.4.2.1 Compliance Permit # Job Information Builder: DR HORTON Community: CREEKSIDE Lot: 5 Address: 3331 HOMESTEAD DRIVE Unit: City: FORT PIERCE State: FL Zip: 34945 Air Leakage Test Results Passing results must be 7ACH(50) or less 1265 x GO = 15024.2 = 5.0 Method for calculating building volume; CFM(SO) Building Volume ACH(50) 0 Retrieved from architectural plans (RrCode software calculated PASS FAIL O Field measured and calculated i I When ACH(SO) is less than 3, Mechanical Ventilation installation must be verified by building department. Certification of Test Results R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air ieaKage rate or not exceeuu}g , a Ir changes per hour in Climate Zones 1 and 2, 3 air changes per hour in Climate Zones 3 through 8. Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g. (50 Pascals). Testing shall be conducted by wither individuals as defined in Section 553.993(5) or (7), F.S_ or individuals licensed as set forth in Section 489.10S(3)(f), (g), or (i) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of ottne Testing Company Company Name: SUN SEAL LLC Phone: 321-412-0035 1 hereby verify that the above duct leakage testing results are in accordance with the Florida Building Code requirements with the selected compliance path as stated above, either the Prescriptive Method or Performance Method. Date of Test: 02/09/2022 Signature of Tester: Printed Name of Tester: DANIEL MURPHY License/Certification # 5066440 Issuing Authority BPI