HomeMy WebLinkAboutR1 Plans DL2059 Dayli FonsecaM. ALVAREZN.T.S.PARCC-1PROJECT :PROJECT NO.DATE:DRAWING BY:CHECKED BY:SCALE:SHEET TITLE:COVERSHEET NO.ENGINEER'S SEAL2.11.2022LOCATION MAPAERIAL VIEWPLAN VIEWCOORDINATES: LAT 27.323538° , LON -80.336651°COORDINATES: 27° 19' 24.7" N, 80° 20' 11.9" WPER FL STATUTE 377.705 (REVISED 7/1/2017), IMIGUEL ALVAREZ PE 86033 AN ENGINEERLICENSED PURSUANT TO CHAPTER 471,CERTIFY THAT THE PV ELECTRICAL SYSTEMAND ELECTRICAL COMPONENTS AREDESIGNED AND APPROVED USING THESTANDARDS CONTAINED IN THE MOSTRECENT VERSION OF THE FLORIDA BUILDINGCODE.PROPRIETARY RIGHTS DRAWING CONCEPT &DESIGNS ARE THE PROPERTY OF WINDMARAND IS SUBMITTED WITH THEUNDERSTANDING THAT IT IS NOT TO BEREPRINTED, COPIED, IN WHOLE OR IN PART,NOR LOANED TO ANY THIRD PARTY NORUSED IN ANY MANNER DETRIMENTAL TO THEINTERESTS OF WINDMAR WITHOUT ITSEXPRESSED WRITTEN CONSENT.DAYLI FONSECA 192 NE CAPRONA AVE PORT ST. LUCIE, FL 34983DL2059PERMITTING / PLANNING NOTESINDEXC-1 COVERE-1 - E4 ELECTRICAL DIAGRAM & CALCULATIONSS-1 - S-2 SYSTEM LAYOUTS-3 - S-4 STRUCTURAL CALCULATIONSSCOPE OF WORK:INSTALLATION OF GRID-TIED PHOTOVOLTAIC SYSTEMREVISIONSR#DATEDESCRIPTIONCONTACT US:6753 KINGSPOINTEPARKWAY SUITE 111,ORLANDO FL, 32819 USATEL: +1 407-308-0099engineering@windmarhome.comNOTE: ENGINEER CERTIFIES THAT THIS PLAN COMPLIESWITH 107.3.5 FBC.This item has been digitally signed and sealedby Miguel Alvarez on the date adjacent to theseal. Printed copies of this document are notconsidered signed and sealed and thesignature must be verified on any electroniccopies.NOTE: IN THE EVENT OF CONFLICTING REGULATIONSTHE MOST RESTRICTIVE SHALL PREVAIL.E-2 SHEET - CHANGE IN ELECTRICAL CONFIGURATION.2/10/2022R1E-8 - E-9 TESLA EQUIPMENT SPECSE-5 - E-7 EQUIPMENT DATASHEETSFIREBUILDINGELECTRICAL2020 FBC, 7TH 2017 NEC & NFPA 70FLORIDA CODE SUMMARYFL Fire PreventionCode 7th Edition& 2018 IBCS-1 SHEET - CHANGE IN PV ARRAY CONFIGURATION.2/10/2022R1 M. ALVAREZN.T.S.PARCE-1PROJECT :PROJECT NO.DATE:DRAWING BY:CHECKED BY:SCALE:SHEET TITLE:SHEET NO.ENGINEER'S SEAL2.11.2022PER FL STATUTE 377.705 (REVISED 7/1/2017), IMIGUEL ALVAREZ PE 86033 AN ENGINEERLICENSED PURSUANT TO CHAPTER 471,CERTIFY THAT THE PV ELECTRICAL SYSTEMAND ELECTRICAL COMPONENTS AREDESIGNED AND APPROVED USING THESTANDARDS CONTAINED IN THE MOSTRECENT VERSION OF THE FLORIDA BUILDINGCODE.PROPRIETARY RIGHTS DRAWING CONCEPT &DESIGNS ARE THE PROPERTY OF WINDMARAND IS SUBMITTED WITH THEUNDERSTANDING THAT IT IS NOT TO BEREPRINTED, COPIED, IN WHOLE OR IN PART,NOR LOANED TO ANY THIRD PARTY NORUSED IN ANY MANNER DETRIMENTAL TO THEINTERESTS OF WINDMAR WITHOUT ITSEXPRESSED WRITTEN CONSENT.ELECTRICAL DIAGRAM &CALCULATIONDAYLI FONSECA 192 NE CAPRONA AVE PORT ST. LUCIE, FL 34983DL2059 CONTACT US:6753 KINGSPOINTEPARKWAY SUITE 111,ORLANDO FL, 32819 USATEL: +1 407-308-0099engineering@windmarhome.comThis item has been digitally signed and sealedby Miguel Alvarez on the date adjacent to theseal. Printed copies of this document are notconsidered signed and sealed and thesignature must be verified on any electroniccopies.THE NEC GIVES YOU THE CHOICE OF FOUR METHODS FOR ENSURING ELECTRICAL CONTINUITY AT SERVICEEQUIPMENT, SERVICE RACEAYS, AND SERVICE CONDUCTOR ENCLOSURES (250.92(B):1.BONDING JUMPERS. BOND METAL PARTS TO THE SERVICE NEUTRAL CONDUCTOR. THIS REQUIRES A MAINBONDING JUMPER [250.24(B) AND 250.28]. BECAUSE THE SERVICE NEUTRAL CONDUCTOR PROVIDES THEEFFECTIVE GROUND-FAULT CURRENT PATH TO THE POWER SUPPLY [250.24(C), YOU DON'T HAVE TOINSTALL AN EQUIPMENT GROUNDING CONDUCTOR WITHIN PVC CONDUIT CONTAINING SERVICE-ENTRANCECONDUCTORS [250.142(A)(1) and 352.60 ex 2].2.THREADEDLESS FITTINGS. TERMINATE METAL RACEWAYS TO METAL ENCLOUSURES BY THREADED HUBSON ENCLOUSURES (IF MADE WRENCHTIGHT).3.THREADEDLESS FITTINGS. TERMINATE METAL RACEWAYS TO METAL ENCLOUSURES BY THREADLESSFITTINGS (IF MADE TIGHT).4.OTHER LISTED DEVICES. THESE INCLUDE BONDING-TYPE LOCKNUTS, BUSHINGS, WEDGES, OR BUSHINGSWITH BONDING JUMPERS.WHERE TWO SOURCES, ONE A UTILITY AND THE OTHERAN INVERTER, ARE LOCATED AT OPPOSITE ENDS OF ABUSBAR THAT CONTAINS LOADS, THE SUM OF 125% OFTHE INVERTER(S) OUTPUT CIRCUIT CURRENT AND THERATING OF THE OVERCURRENT DEVICE PROTECTING THEBUSBAR SHALL NOT EXCEED 120% THE AMPACITY OF THEBUSBAR. THE BUSBAR SHALL BE SIZED FOR THE LOADSCONNECTED IN ACCORDANCE WITH ARTICLE 220. APERMANENT WARNING LABEL SHALL BE APPLIED TO THEDISTRIBUTION EQUIPMENT ADJACENT TO THE BACK-FEDBREAKER FROM THE INVERTER THAT DISPLAYS THEFOLLOWING OR EQUIVALENT WORDING:IMPORTANT NOTE: NEC 705.12FILL CALCULATIONS NOTE: ALL FILL CALCULATIONSON THIS DESIGN HAVE BEEN DONE IN COMPLIANCEWITH NEC312.8.CROSS SECTIONAL AREA CALCULATION:CROSS SECTIONAL AREA OF 46 THHN = 0.2028 SQ.IN.;CROSS SECTIONAL AREA OF 1' TUBE. 0.79 SQ.IN. FILL % =(0.2028 / 0.79) x 100 = 25.7% < 40%WARNING:INVERTER OUTPUT CONNECTION; DO NOTRELOCATE THIS OVERCURRENT DEVICE.THE WARNING SIGN(S) OR LABEL(S) SHALL COMPLYWITH 110.21(B).EXCEPTION: EQUIPMENT WITH MULTIPLEAMPACITY BUSBARS OR CENTER FEDPANELBOARDS ARE NOT ADDRESSED BY THISPROVISION.NEC : (BUS RATING) X 1.2 - (MAIN BREAKER) = 120%RULE 5ROOF LEVELTOTAL W: WATTS DC / WATTS ACMSP BUSBAR RATING:TOTAL PV MODULES: PHOTOVOLTAIC MODULESPV MODEL: HANWHA Q-CELLS Q.PEAK DUO-G8+ 350MICROINVERTER: ENPHASE IQ7PLUS-72-2-USBATTERY: TESLA POWERWALL 2 ACSYSTEM DATA288,120200A9,80019161867IQ ENVOYNOTES:·ALL CONDUITS AND RACEWAYS APPROVED PER METHOD NEC 2017 AND FBC 2020. IN THE EVENT OF CONFLICTING REGULATIONS THE MOST RESTRICTIVE SHALL PREVAIL.·ALL EQUIPMENT IS SUITABLE FOR OUTDOORS INSTALLATION AND RATED FOR 90°F.·THE SIZE OF ALL CONDUCTORS BASED ON THEIR AMPACITY FOR AN AMBIENTTEMPERATURE OF 194°F (90°C) WAS TAKEN FROM NEC TABLE B.310.15(B)(2)(1).B2B3B4B5B6B7B8B9B10B1A2A1C2C3C4C5C6C7C8C9C10C1412B11C11INSIDE RESIDENCEL1L2POWERWALLAUXS1S240AC12C13B12B1315A20A20APRODUCTIONCT20AGROND LEVEL5A22151723251211340A30A150A150A70A248910101313142021ITEM DESCRIPTION:1 PV MODULES, TYPE : HANWHA Q-CELLS Q.PEAK DUO-G8+ 35023467MICROINVERTER: ENPHASE IQ7PLUS-72-2-US (EQUIPPED WITH RAPID SHUTDOWN) ENPHASE Q CABLE MALE CONNECTOR (Q-12-10-240) 12 AWG DOUBLE INSULATED THHN/THWN-2.16 EXISTING _____ MAIN BREAKER150AEXISTING BUS RATED MAIN SERVICE PANELENPHASE IQ COMBINER BOX 3C-ES WITH IQ ENVOY METER (X-IQ-AM1-240-3C-ES) 125A BUS RATING120/240 VAC WITH 2 BREAKERS 20A/2-P & 1 BREAKER 15A/2-P FOR IQ ENVOY METER.TESLA POWERWALL 2 AC BATTERY.EXISTING GROUNDING ELECTRODE CONDUCTOR.51 ENPHASE RAW Q CABLE (Q-12-RAW-300) PER BRANCH AND 1#6 BARE COPPER FOR GROUNDIN 3/4" CONDUIT.3#10 THHN AND 1#10 THHN FOR GROUND IN 1" CONDUIT.1918200A3#6 THHN AND 1#6 THHN FOR GROUND IN 1" CONDUIT.92#10 THHN PER BRANCH AND 1#6 THHN FOR GROUND IN 1" CONDUIT TO CARRY BRANCH CIRCUITCONDUCTORS TO COMBINER BOX. INSTALL PVC EXPANSION FITTING WHERE NEEDED.EXISTING UTILITY METER.JUNCTION BOX 6" × 6" SUITABLE FOR WET LOCATIONS (UL ENVIRONMENTAL RATING TYPE 4X).TESLA BACKUP GATEWAY 2BG2 HAS AN INTEGRATED CONTACTORMAIN BREAKER NOT INSTALLEDNEUTRAL-GROUND BONDING STRAP NOT INSTALLED3#1/0 THHN AND 1#6 THHN FOR GROUND IN 2" CONDUIT.LUG TO LUG CONNECTION.20A/2-P BACKFEED CIRCUIT BREAKER IN MAIN SERVICE PANELNEC 705.12 120% RULE:(200A BUS RATING × 1.2) - 150A MAIN BREAKER = 90A90A - 70A DOWNSTREAM BACKFEED = 20A AVAILABLE FOR SOLAR3#10 THHN AND 1#6 THHN FOR GROUND IN 3/4" CONDUIT.2223GENERATION PANEL125A BUS RATED MLO LOADCENTER 8-SPACE, 16-CIRCUIT,120/240V, NEMA 3R:(1) 70A/2-P BREAKER FOR GENERATION PANEL OCPD(1) 40A/2-P BREAKER FOR PHOTOVOLTAIC SYSTEM OCPD(1) 30A/2-P BREAKER FOR TESLA POWERWALL OCPDEXISTING 200A BUS RATED INTERIOR DISTRIBUTION SUBPANEL3#1/0 THHN AND 1#6 THHN FOR GROUND IN 2" CONDUIT.2517860A FUSED DISCONNECT FOR AC PV DISCONNECT/RAPID SHUTDOWN DISCONNECTWITH 40A FUSESNOTE: DO NOT INSTALL NEUTRAL-TO-CASE BONDING GREEN SCREW, THIS PREVENTSOBJECTIONABLE CURRENT AS PER NEC 250.6.× 1.21A × 1.25 = 39.325A = 40A (OCPD)26101160A FUSED DISCONNECT FOR AC PV DISCONNECT/RAPID SHUTDOWN DISCONNECTWITH 5A FUSESNOTE: DO NOT INSTALL NEUTRAL-TO-CASE BONDING GREEN SCREW, THIS PREVENTSOBJECTIONABLE CURRENT AS PER NEC 250.6.× 1.21A × 1.25 = 3.025A = 5A (OCPD)21312143#4 THHN AND 1#6 THHN FOR GROUND IN 1-1/2" CONDUIT.15202124M. ALVAREZN.T.S.PARCE-2PROJECT :PROJECT NO.DATE:DRAWING BY:CHECKED BY:SCALE:SHEET TITLE:SHEET NO.ENGINEER'S SEAL2.11.2022PER FL STATUTE 377.705 (REVISED 7/1/2017), IMIGUEL ALVAREZ PE 86033 AN ENGINEERLICENSED PURSUANT TO CHAPTER 471,CERTIFY THAT THE PV ELECTRICAL SYSTEMAND ELECTRICAL COMPONENTS AREDESIGNED AND APPROVED USING THESTANDARDS CONTAINED IN THE MOSTRECENT VERSION OF THE FLORIDA BUILDINGCODE.PROPRIETARY RIGHTS DRAWING CONCEPT &DESIGNS ARE THE PROPERTY OF WINDMARAND IS SUBMITTED WITH THEUNDERSTANDING THAT IT IS NOT TO BEREPRINTED, COPIED, IN WHOLE OR IN PART,NOR LOANED TO ANY THIRD PARTY NORUSED IN ANY MANNER DETRIMENTAL TO THEINTERESTS OF WINDMAR WITHOUT ITSEXPRESSED WRITTEN CONSENT.ELECTRICAL DIAGRAM &CALCULATIONSYSTEM RISER WIRING DIAGRAM EQUIPMENT LOCATIONSCALE: NTSDAYLI FONSECA 192 NE CAPRONA AVE PORT ST. LUCIE, FL 34983DL2059 CONTACT US:6753 KINGSPOINTEPARKWAY SUITE 111,ORLANDO FL, 32819 USATEL: +1 407-308-0099engineering@windmarhome.comThis item has been digitally signed and sealedby Miguel Alvarez on the date adjacent to theseal. Printed copies of this document are notconsidered signed and sealed and thesignature must be verified on any electroniccopies.R1 MODULE MAKEPV MODULE RATINGSMODULE MODELMAX POWEROPEN CIRCUIT VOLTAGEMAX POWER POINT VOLTAGESHORT CIRCUIT CURRENTMAX POWER POINT CURRENTHANWHA Q-CELLSQ.PEAK DUO-G8+ 350350 W40.70 V34.24 V10.74 A10.22 A=======PV MODULEITEMINVERTERALL DISCONNECTSALL OVERCURRENTPROTECTIONFSEC CERTIFICATIONNUMBERMANUFACTURERMODELLISTING / COMPLIANCE1.TOTAL PHOTOVOLTAIC SYSTEM STC RATED DC POWER PRODUCTION OF W.2.INVERTER HAS MAXIMUM POWER POINT TRACKING (MPPT).3.INVERTER MEETS REQUIREMENTS OF 3-P POWER.4.INVERTER MEETS IEEE 1547.5.INVERTER MEETS UL1741.6.ALL ELECTRICAL EQUIPMENT INSTALLED ARE UL LISTED.7.FBC ADMINISTRATION CODES NOW IN EFFECT NEC 2017; FBC 2020" E-1 FBC ADMINISTRATION"ALL ELECTRONICS, SOLAR PANELS AND ASSOCIATED ELECTRICAL EQUIPMENT TO BE INSTALLEDARE UL LISTED."SYSTEM AUTOMATIC OPERATION1.GRID POWER IS PRESENT, PHOTOVOLTAIC SYSTEM FEEDS THE LOAD AT DAY TIME.2.GRID POWER IS LOST, PHOTOVOLTAIC SYSTEM AUTOMATICALLY DISCONNECTS FROM THE GRID.3.PHOTOVOLTAIC SYSTEM WILL AUTOMATICALLY RESUME FEEDING POWER TO THE GRID. WHENTHE PROPER GRID VOLTAGE AND FREQUENCY IS RESTORED (IEEE STANDARDS) AND THERE ISENOUGH SUNLIGHT.IQ7+ENPHASEAMPSQ-CELLENPHASEQ-CELLENPHASEENPHASEENPHASE350WIQ7+DC & ACDC & AC350WIQ7+ULULULULRV-16-0106A9,800THE NEC GIVES YOU THE CHOICE OF FOUR METHODS FOR ENSURING ELECTRICAL CONTINUITY AT SERVICE EQUIPMENT, SERVICE RACEWAYS, AND SERVICECONDUCTOR ENCLOSURES [250.92(B):1.BONDING JUMPERS. BOND METAL PARTS TO THE SERVICE NEUTRAL CONDUCTOR. THIS REQUIRES A MAIN BONDING JUMPER [250.24(B) AND 250.28].BECAUSE THE SERVICE NEUTRAL CONDUCTOR PROVIDES THE EFFECTIVE GROUND-FAULT CURRENT PATH TO THE POWER SUPPLY [250.24(C)], YOU DON'T HAVETO INSTALL AN EQUIPMENT GROUNDING CONDUCTOR WITHIN PVC CONDUIT CONTAINING SERVICE-ENTRANCE CONDUCTORS [250.142(A)(1) AND 352.60 EX 2].1.THREADED FITTINGS. TERMINATE METAL RACEWAYS TO METAL ENCLOSURES BY THREADED HUBS ON ENCLOSURES (IF MADE WRENCHTIGHT).2.THREADLESS FITTINGS. TERMINATE METAL RACEWAYS TO METAL ENCLOSURES BY THREADLESS FITTINGS (IF MADE TIGHT).3.OTHER LISTED DEVIDES. THESE INCLUDE BONDING-TYPE LOCKNUTS, BUSHINGS, WEDGES, OR BRUSHINGS WITH BONDING JUMPERS.DESIGN TEMP 91 DEG C, ADDER 60 DEG C (310.15(B)(2)(C), TOTAL 151 DEG C MULTIPLIER AT 151 DEG C IS .58 (310.16 CORRECTION FACTORS). #10 THWN-2 RATED40 AMPS, TIMES .58 = 232 AMPS. 8 CONDUCTORS IN SINGLE CONDUIT ADJUSTMENT FACTOR IS 50% 23.2 X .7 = 16.24 AMPS.BONDING MIDCLAMP ASSEMBLY1.STAINLESS STEAL MIDCLAMP POINTS, 2 PER MODULE, PIERCE MODULE FRAME ANODIZATION TO BOND MODULE TO MODULE THROUGH CLAMP.2.SERRATED FLANGE NUT BONDS STAINLESS STEEL CLAMP TO STAINLESS STEEL T-BOLT.3.SERRATED T-BOLT HEAD PENETRATES RAIL ANODIZATION TO BOND T-BOLT, NUT, CLAMP, AND MODULES TO GROUNDED SM RAIL.M. ALVAREZN.T.S.PARCE-3PROJECT :PROJECT NO.DATE:DRAWING BY:CHECKED BY:SCALE:SHEET TITLE:SHEET NO.ENGINEER'S SEAL2.11.2022PER FL STATUTE 377.705 (REVISED 7/1/2017), IMIGUEL ALVAREZ PE 86033 AN ENGINEERLICENSED PURSUANT TO CHAPTER 471,CERTIFY THAT THE PV ELECTRICAL SYSTEMAND ELECTRICAL COMPONENTS AREDESIGNED AND APPROVED USING THESTANDARDS CONTAINED IN THE MOSTRECENT VERSION OF THE FLORIDA BUILDINGCODE.PROPRIETARY RIGHTS DRAWING CONCEPT &DESIGNS ARE THE PROPERTY OF WINDMARAND IS SUBMITTED WITH THEUNDERSTANDING THAT IT IS NOT TO BEREPRINTED, COPIED, IN WHOLE OR IN PART,NOR LOANED TO ANY THIRD PARTY NORUSED IN ANY MANNER DETRIMENTAL TO THEINTERESTS OF WINDMAR WITHOUT ITSEXPRESSED WRITTEN CONSENT.ELECTRICAL DIAGRAM &CALCULATIONDAYLI FONSECA 192 NE CAPRONA AVE PORT ST. LUCIE, FL 34983DL2059 CONTACT US:6753 KINGSPOINTEPARKWAY SUITE 111,ORLANDO FL, 32819 USATEL: +1 407-308-0099engineering@windmarhome.comThis item has been digitally signed and sealedby Miguel Alvarez on the date adjacent to theseal. Printed copies of this document are notconsidered signed and sealed and thesignature must be verified on any electroniccopies. Voltage Drop Calculation (2*L*Imax*k) D - L = Length of wire - k = Wire material - Imax = Current - 2 = Constant - D = Conductor PropertiesResults:VD =2.49 VVD =Results:VD =1.04 %Temperature CorrectionFormula: _______I_________ Temperature RatingImax =Results:46.87 ATC =Ambient Temperature Correction FactorsØAmbient Temperature: 31-35 (◦ C)ØTemperature Rating of Conductor: 0.96ØAmbient Temperature: 87-95 ◦ FConductors NEC 2017 - Table 310.15(B)(17) Allowable Ampacities ofSingle-Insulated Conductors Rated Up to and Including2,000 Volts in Free Air, Based on AmbientTemperatureØCable #6 AWG THWN- 2 - Capacity 105 A under 90◦ CØConduit 1" PVC Schedule 40 - Capacity 6 conductorsNEC 2017 - TABLE 310.15(B)(A)Formula:System overviewSolar panels: x HANWHA 350W (PV - array)Inverters: x IQ7+ - 240VAC (Inverter efficiency: 95%)Mounting type: UniracEvaluation of design Location: Florida, United States Record Low Temperature: 35.00 °F Average High Temperature: 78.00 °F Record High Temperature: 98.00 °FTechnical DataPV Peak Power: kWpNumber of PV modulesNumber of InvertersMax. DC Power 350WMax. AC Power 290WGrid voltage: 240WNominal power ratio: 95%PV array:Number of PV modulesNumber of InvertersPeak Power Input 350WpMPP PV voltage 34.07VOC PV voltage 40.73VMin. DC voltage (240V Grid) 22.0VMax. PV voltage 40VMax. DC voltage (Inverter) 48VMax. current of PV 10.79AMax. DC current 10.27 APV & Inverter compatiblePV array and type of inverter are compatible. The nominalpowerratio (Max. DC power of the inverter divided by the peakpower)is within the recommended range (80% - 120%).2828282828288,120M. ALVAREZN.T.S.PARCE-4PROJECT :PROJECT NO.DATE:DRAWING BY:CHECKED BY:SCALE:SHEET TITLE:SHEET NO.ENGINEER'S SEAL2.11.2022PER FL STATUTE 377.705 (REVISED 7/1/2017), IMIGUEL ALVAREZ PE 86033 AN ENGINEERLICENSED PURSUANT TO CHAPTER 471,CERTIFY THAT THE PV ELECTRICAL SYSTEMAND ELECTRICAL COMPONENTS AREDESIGNED AND APPROVED USING THESTANDARDS CONTAINED IN THE MOSTRECENT VERSION OF THE FLORIDA BUILDINGCODE.PROPRIETARY RIGHTS DRAWING CONCEPT &DESIGNS ARE THE PROPERTY OF WINDMARAND IS SUBMITTED WITH THEUNDERSTANDING THAT IT IS NOT TO BEREPRINTED, COPIED, IN WHOLE OR IN PART,NOR LOANED TO ANY THIRD PARTY NORUSED IN ANY MANNER DETRIMENTAL TO THEINTERESTS OF WINDMAR WITHOUT ITSEXPRESSED WRITTEN CONSENT.ELECTRICAL DIAGRAM &CALCULATIONDAYLI FONSECA 192 NE CAPRONA AVE PORT ST. LUCIE, FL 34983DL2059 PROPRIETARY RIGHTS DRAWINGCONCEPT & DESIGNS ARE THEPROPERTY OF WINDMAR AND ISSUBMITTED WITH THEUNDERSTANDING THAT IT IS NOT TOBE REPRINTED, COPIED, IN WHOLEOR IN PART, NOR LOANED TO ANYTHIRD PARTY NOR USED IN ANYMANNER DETRIMENTAL TO THEINTERESTS OF WINDMAR WITHOUTITS EXPRESSED WRITTEN CONSENT.PER FL STATUTE 377.705(REVISED 7/1/2017), IMIGUEL ALVAREZ PE86033 AN ENGINEERLICENSED PURSUANT TOCHAPTER 471, CERTIFYTHAT THE PVELECTRICAL SYSTEMAND ELECTRICALCOMPONENTS AREDESIGNED ANDAPPROVED USING THESTANDARDS CONTAINEDIN THE MOST RECENTVERSION OF THEFLORIDA BUILDINGCODE.CROSS SECTIONAL AREAOF 4 #6 THHN = 0.2028 SQ INCROSS SECTIONAL AREAOF 1' TUBE. = 0.79 SQ INFILL % = (0.2028/0.79)*100 =25.7% < 40%CONTACT US:6753 KINGSPOINTEPARKWAY SUITE 111,ORLANDO FL, 32819 USATEL: +1 407-308-0099engineering@windmarhome.comThis item has been digitally signed and sealedby Miguel Alvarez on the date adjacent to theseal. Printed copies of this document are notconsidered signed and sealed and thesignature must be verified on any electroniccopies. M. ALVAREZN.T.S.PARCE-5PROJECT :PROJECT NO.DATE:DRAWING BY:CHECKED BY:SCALE:SHEET TITLE:SHEET NO.ENGINEER'S SEAL2.11.2022PER FL STATUTE 377.705 (REVISED 7/1/2017), IMIGUEL ALVAREZ PE 86033 AN ENGINEERLICENSED PURSUANT TO CHAPTER 471,CERTIFY THAT THE PV ELECTRICAL SYSTEMAND ELECTRICAL COMPONENTS AREDESIGNED AND APPROVED USING THESTANDARDS CONTAINED IN THE MOSTRECENT VERSION OF THE FLORIDA BUILDINGCODE.PROPRIETARY RIGHTS DRAWING CONCEPT &DESIGNS ARE THE PROPERTY OF WINDMARAND IS SUBMITTED WITH THEUNDERSTANDING THAT IT IS NOT TO BEREPRINTED, COPIED, IN WHOLE OR IN PART,NOR LOANED TO ANY THIRD PARTY NORUSED IN ANY MANNER DETRIMENTAL TO THEINTERESTS OF WINDMAR WITHOUT ITSEXPRESSED WRITTEN CONSENT.EQUIPMENTDATASHEETSDAYLI FONSECA 192 NE CAPRONA AVE PORT ST. LUCIE, FL 34983DL2059 CONTACT US:6753 KINGSPOINTEPARKWAY SUITE 111,ORLANDO FL, 32819 USATEL: +1 407-308-0099engineering@windmarhome.comThis item has been digitally signed and sealedby Miguel Alvarez on the date adjacent to theseal. Printed copies of this document are notconsidered signed and sealed and thesignature must be verified on any electroniccopies.IQ COMBINER BOX 3C-ESHANWHA Q-CELL DATASHEET M. ALVAREZN.T.S.PARCE-6PROJECT :PROJECT NO.DATE:DRAWING BY:CHECKED BY:SCALE:SHEET TITLE:SHEET NO.ENGINEER'S SEAL2.11.2022PER FL STATUTE 377.705 (REVISED 7/1/2017), IMIGUEL ALVAREZ PE 86033 AN ENGINEERLICENSED PURSUANT TO CHAPTER 471,CERTIFY THAT THE PV ELECTRICAL SYSTEMAND ELECTRICAL COMPONENTS AREDESIGNED AND APPROVED USING THESTANDARDS CONTAINED IN THE MOSTRECENT VERSION OF THE FLORIDA BUILDINGCODE.PROPRIETARY RIGHTS DRAWING CONCEPT &DESIGNS ARE THE PROPERTY OF WINDMARAND IS SUBMITTED WITH THEUNDERSTANDING THAT IT IS NOT TO BEREPRINTED, COPIED, IN WHOLE OR IN PART,NOR LOANED TO ANY THIRD PARTY NORUSED IN ANY MANNER DETRIMENTAL TO THEINTERESTS OF WINDMAR WITHOUT ITSEXPRESSED WRITTEN CONSENT.EQUIPMENTDATASHEETS60A AC FUSED DISCONNECTDAYLI FONSECA 192 NE CAPRONA AVE PORT ST. LUCIE, FL 34983DL2059 CONTACT US:6753 KINGSPOINTEPARKWAY SUITE 111,ORLANDO FL, 32819 USATEL: +1 407-308-0099engineering@windmarhome.comThis item has been digitally signed and sealedby Miguel Alvarez on the date adjacent to theseal. Printed copies of this document are notconsidered signed and sealed and thesignature must be verified on any electroniccopies.IQ7+ MICROINVERTER IMPORTANTNOTE:NEC480.9(A)(B)(C)M. ALVAREZN.T.S.PARCE-7PROJECT :PROJECT NO.DATE:DRAWING BY:CHECKED BY:SCALE:SHEET TITLE:SHEET NO.ENGINEER'S SEAL2.11.2022PER FL STATUTE 377.705 (REVISED 7/1/2017), IMIGUEL ALVAREZ PE 86033 AN ENGINEERLICENSED PURSUANT TO CHAPTER 471,CERTIFY THAT THE PV ELECTRICAL SYSTEMAND ELECTRICAL COMPONENTS AREDESIGNED AND APPROVED USING THESTANDARDS CONTAINED IN THE MOSTRECENT VERSION OF THE FLORIDA BUILDINGCODE.PROPRIETARY RIGHTS DRAWING CONCEPT &DESIGNS ARE THE PROPERTY OF WINDMARAND IS SUBMITTED WITH THEUNDERSTANDING THAT IT IS NOT TO BEREPRINTED, COPIED, IN WHOLE OR IN PART,NOR LOANED TO ANY THIRD PARTY NORUSED IN ANY MANNER DETRIMENTAL TO THEINTERESTS OF WINDMAR WITHOUT ITSEXPRESSED WRITTEN CONSENT.EQUIPMENTDATASHEETSTESLA POWERWALLDAYLI FONSECA 192 NE CAPRONA AVE PORT ST. LUCIE, FL 34983DL2059 CONTACT US:6753 KINGSPOINTEPARKWAY SUITE 111,ORLANDO FL, 32819 USATEL: +1 407-308-0099engineering@windmarhome.comThis item has been digitally signed and sealedby Miguel Alvarez on the date adjacent to theseal. Printed copies of this document are notconsidered signed and sealed and thesignature must be verified on any electroniccopies.TESLA BACKUP GATEWAY 2 WIRING METHODSBACKUP GATEWAY CONNECTION DIAGRAMSCALE: NTS1.ALL CONDUITS AND FITTINGS PROPERLY INSTALLED PERTHE RESPECTIVE ARTICLE IN CHAPTER 3 PF THE NEC.2.CONDUIT IS ADEQUATELY SECURED AND SUPPORTED.3.RACEWAYS CONTAINING INSULATEC CIRCUITCONDUCTORS 4 AWG AND LARGER ARE PROTECTED FROMABRASION BY AN IDENTIFIED FITTING PROVIDING ASMOOTHLY ROUNDED INSULATING SURFACE. 300.4(G).4.RESIDENTIAL ENERGY STORAGE EQUIPMENT GROUNDINGCONDUCTOR IS IDENTIFIED AS EITHER BARE, GREEN, ORGREEN WITH CONTINOUS YELLOW STRIPE(S). 250.119.5.GROUNDED CONDUCTOR IDENTIFIED PROPERLY. 200.6(A),(B).POWERWALL INSTALLATION BRACKET DETAILSCALE: NTSM. ALVAREZN.T.S.PARCE-8PROJECT :PROJECT NO.DATE:DRAWING BY:CHECKED BY:SCALE:SHEET TITLE:SHEET NO.ENGINEER'S SEAL2.11.2022PER FL STATUTE 377.705 (REVISED 7/1/2017), IMIGUEL ALVAREZ PE 86033 AN ENGINEERLICENSED PURSUANT TO CHAPTER 471,CERTIFY THAT THE PV ELECTRICAL SYSTEMAND ELECTRICAL COMPONENTS AREDESIGNED AND APPROVED USING THESTANDARDS CONTAINED IN THE MOSTRECENT VERSION OF THE FLORIDA BUILDINGCODE.PROPRIETARY RIGHTS DRAWING CONCEPT &DESIGNS ARE THE PROPERTY OF WINDMARAND IS SUBMITTED WITH THEUNDERSTANDING THAT IT IS NOT TO BEREPRINTED, COPIED, IN WHOLE OR IN PART,NOR LOANED TO ANY THIRD PARTY NORUSED IN ANY MANNER DETRIMENTAL TO THEINTERESTS OF WINDMAR WITHOUT ITSEXPRESSED WRITTEN CONSENT.EQUIPMENTDATASHEETSDAYLI FONSECA 192 NE CAPRONA AVE PORT ST. LUCIE, FL 34983DL2059 CONTACT US:6753 KINGSPOINTEPARKWAY SUITE 111,ORLANDO FL, 32819 USATEL: +1 407-308-0099engineering@windmarhome.comThis item has been digitally signed and sealedby Miguel Alvarez on the date adjacent to theseal. Printed copies of this document are notconsidered signed and sealed and thesignature must be verified on any electroniccopies. M. ALVAREZN.T.S.PARCE-9PROJECT :PROJECT NO.DATE:DRAWING BY:CHECKED BY:SCALE:SHEET TITLE:SHEET NO.ENGINEER'S SEAL2.11.2022PER FL STATUTE 377.705 (REVISED 7/1/2017),I MIGUEL ALVAREZ PE 86033 AN ENGINEERLICENSED PURSUANT TO CHAPTER 471,CERTIFY THAT THE PV ELECTRICAL SYSTEMAND ELECTRICAL COMPONENTS AREDESIGNED AND APPROVED USING THESTANDARDS CONTAINED IN THE MOSTRECENT VERSION OF THE FLORIDABUILDING CODE.PROPRIETARY RIGHTS DRAWING CONCEPT &DESIGNS ARE THE PROPERTY OF WINDMARAND IS SUBMITTED WITH THEUNDERSTANDING THAT IT IS NOT TO BEREPRINTED, COPIED, IN WHOLE OR IN PART,NOR LOANED TO ANY THIRD PARTY NORUSED IN ANY MANNER DETRIMENTAL TO THEINTERESTS OF WINDMAR WITHOUT ITSEXPRESSED WRITTEN CONSENT.EQUIPMENTDATASHEETSGROUND LEVELROOF LEVELBACKUP GATEWAY 2MAIN PANELCRITICAL LOADSAC COMBINER BOXEXISTINGUTILITY METERPOWERWALL CLEARANCESSCALE: NTS6IN.2IN.2IN.WIRING AND EQUIPMENT SUPPLIED FROM STORAGE BATTERIES SHALL BE SUBJECT TO THE APPLICABLEPROVISIONS OF THIS CODE APPLYING TO WIRING AND EQUIPMENT OPERATING AT THE SAME VOLTAGE, UNLESSOTHERWISE PERMITTED BY 480.5.NEC 480.4 WIRING AND EQUIPMENT SUPPLIED FROM BATTERIES:BATTERY LOCATIONS SHALL CONFORM TO 480.9(A), (B), AND (C).(A)VENTILATION. PROVISIONS SHALL BE MADE FOR SUFFICIENT DIFFUSION AND VENTILATION OF THE GASESFROM THE BATTERY TO PREVENT THE ACCUMULATION OF AN EXPLOSIVE MIXTURE.(B)LIVE PARTS. GUARDING OF LIVE PARTS SHALL COMPLY WITH 110.28.(C)SPACES ABOUT BATTERY SYSTEMS. SPACES ABOUT BATTERY SYSTEMS SHALL COMPLY WITH 110.26.WORKING SPACE SHALL BE MEASURED FROM THE EDGE OF THE BATTERY CABINET, RACKS, OR TRAYS.NEC 480.8 (C) ACCESSIBILITY:THE TERMINALS OF ALL CELLS ORMULTI-CELL UNITS SHALL BEREADILY ACCESSIBLE FORREADINGS, INSPECTION, ANDCLEANING WHERE REQUIRED BYTHE EQUIPMENT DESIGN. ONESIDE OF TRANSPARENT BATTERYCONTAINERS SHALL BE READILYACCESSIBLE FOR INSPECTION OFTHE INTERNAL COMPONENTS.GATEWAY ELECTRICALDISCONNECT CURRENTCERTIFICATIONS AND STANDARDSOVERCURRENT PROTECTION BREAKEROVERVOLTAGE CATEGORYFAULT CURRENT WITHSTAND RATINGAC METERSERVICE RATING200A100-200A (SERVICE ENTRANCE RATED)CATEGORY IV10KAIC (CONFIGURABLE TO 22 KAIC)REVENUE ACCURATE (+/- 0.2%)SUITABLE FOR USE AS SERVICE EQUIPMENTSAFETYUL 67,UL 869A, UL 916, UL 1741 PCS,CSA 22.2 0.19, CSA C22.2 205EMISSIONGRID STANDARDSWORLDWIDE COMPATIBILITYFCC PART 15 CLASS B, ICES 003ENVIROMENTALINDOOR AND OUTDOOR RATED - NEMA 3RSEISMICAC156, IEEE 693-2005 (HIGH)INVERTER MAKEINVERTER MODELMAX OUTPUT FAULT CURRENTINTERNAL BATTERY DC VOLTAGEUSABLE ENERGY / REAL POWER MAX CONT.WARRANTYTESLAPOWERWALL 232A50V13.5kWh / 5kW10 YEARS=======APPARENT POWER MACCONT / PEAK (10S)5.8kVA (CHARGE & DISCHARGE) /7.2kVA (DISCHARGE ONLY)POWERWALL VOLTAGE RANGEIMPORTANT NOTE:230V-250VBATTERY RATINGSEQUIPMENT LAYOUTSCALE: NTSTHE SYSTEM CONTINUALLY MEASURES HOME POWER CONSUMPTION AND REACTS TO HOME LOADS. FOREXAMPLE:A.WHEN THE HOME LOAD OS HIGHER THAN AVAILABLE PV POWER POWER, THE HOME DRAWS ENERGY FROMBATTERY STORAGE (WHEN AVAILABLE) AND THE GRID.B.WHEN THE HOME LOAD DROPS BELOW AVAILABLE PV POWER, EXCESS PV ENERGY IS STORED IN THEBATTERY UNTIL THE HOME LOAD EXCEED PV POWER.C.ONCE THE BATTERY IS FULLY CHARGED, ANY EXCESS PV GENERATION IS EITHER CURTAILED OR EXPORTEDTO THE GRID, DEPENDING ON LOCAL UTILITY INTERCONNECTION RULES.POWERWALL'S INTERACTION WITH THE GRID IS PRIMARILY HANDLED BY THE BACKUP GATEWAY. THE BACKUPGATEWAY MANAGES THE DISCONNECTION AND RECONNECTION WITH THE GRID - IT DISCONNECTS WHEN THEUTILITY GRID MOVES OUTSIDE OF THE VOLTAGE AND FREQUENCY WINDOWS AS DEFINED IN IEEE 1547, ANDRECONNECTS TO THE GRID ONCE IT IS WITHIN THE IEEE 1547 WINDOWS FOR AT LEAST 5 MINUTES.METER WITH REMOTECOMMUNICATION CAPABILITYTHROUGH THE INTERNET WHICHALLOWS ACCESS TO THE UTILITYTO MONITOR THE SYSTEM,INCLUDING THE STATUS OFENERGY STORAGE. THIS METER ISINCLUDED IN THE LIST OFELIGIBLE METERS OF THECALIFORNIA ENERGYCOMMISSION. CONTACT US:6753 KINGSPOINTEPARKWAY SUITE 111,ORLANDO FL, 32819 USATEL: +1 407-308-0099engineering@windmarhome.comDL2059DAYLI FONSECA 192 NE CAPRONA AVE PORT ST. LUCIE, FL 34983This item has been digitally signed and sealedby Miguel Alvarez on the date adjacent to theseal. Printed copies of this document are notconsidered signed and sealed and thesignature must be verified on any electroniccopies.OPTIONAL INTERNAL PANELBOARD200A 6-space/ 12 circuit Eaton BR circuit breakersTESLA POWERWALL 2 (N) JUNCTION BOX FOR WET LOCATIONSDCACDCACDCACDCACDCACDCACDCAC DCAC DCAC DCACDCACDCACDCACDCACDCACDCACDCACDCACDCACDCACDCACDCACDCACDCACDCACDCACDCACDCACROOF TYPE: ASPHALT SHINGLETOTAL ROOF AREA: 2,600 SQFTTOTAL PHOTOVOLTAIC AREA: SQFTROOF AGE: >10 YEARSPRESSURE ZONE: 1 & 2MEAN ROOF SLOPE:TOTAL MODULES:TOTAL ROOF MOUNTS:TOTAL POINT OF CONNECTIONS PER MODULE: 4RACKING SYSTEM: UNIRACALUMINUM RAILS PER MODULE: 2TILT 1: 20° AZIMUTH 1: 72°TILT 2: 20° AZIMUTH 2: 162°TILT 3: 20° AZIMUTH 3: 162°TILT 4: 20° AZIMUTH 4: 252°TILT 5: 20° AZIMUTH 5: 342°ROOF INFORMATION7228540.124.37/1212543(N) AC COMBINER BOXLEGEND24" & 36" FIRE CODE OFFSETMETER / MAIN SERVICE ENTRANCE PANELENPHASE AC COMBINER BOXINTERIOR DISTRIBUTION SUBPANELJUNCTION BOX SUITABLE FOR WET LOCATIONSAC FUSED DISCONNECT / RSDROOF VENTS(N) AC FUSED DISCONNECT / RSDFOR SOLAR IN BACKUP CIRCUIT(E) METER / MAIN SERVICE ENTRANCE PANELNON-BACKUP LOADS PANEL(N) TESLA POWERWALL 2 AC BATTERY(N) TESLA BACKUP GATEWAY 2(E) INTERIOR DISTRIBUTION SUBPANELBACKUP LOADS PANELTESLA POWERWALL 2 AC BATTERYTESLA BACKUP GATEWAY 2(E) EXISTING EQUIPMENT(N) NEW EQUIPMENT(N) GENERATION PANEL(N) AC FUSED DISCONNECT / RSDFOR SOLAR IN NON-BACKUP CIRCUIT24"36"36"GENERATION PANELM. ALVAREZN.T.S.PARCS-1PROJECT :PROJECT NO.DATE:DRAWING BY:CHECKED BY:SCALE:SHEET TITLE:SHEET NO.ENGINEER'S SEAL2.11.2022PER FL STATUTE 377.705 (REVISED 7/1/2017), IMIGUEL ALVAREZ PE 86033 AN ENGINEERLICENSED PURSUANT TO CHAPTER 471,CERTIFY THAT THE PV ELECTRICAL SYSTEMAND ELECTRICAL COMPONENTS AREDESIGNED AND APPROVED USING THESTANDARDS CONTAINED IN THE MOSTRECENT VERSION OF THE FLORIDA BUILDINGCODE.PROPRIETARY RIGHTS DRAWING CONCEPT &DESIGNS ARE THE PROPERTY OF WINDMARAND IS SUBMITTED WITH THEUNDERSTANDING THAT IT IS NOT TO BEREPRINTED, COPIED, IN WHOLE OR IN PART,NOR LOANED TO ANY THIRD PARTY NORUSED IN ANY MANNER DETRIMENTAL TO THEINTERESTS OF WINDMAR WITHOUT ITSEXPRESSED WRITTEN CONSENT.SYSTEM LAYOUTPHOTOVOLTAIC PANELS LAYOUTSCALE: NTSDAYLI FONSECA 192 NE CAPRONA AVE PORT ST. LUCIE, FL 34983DL2059 CONTACT US:6753 KINGSPOINTEPARKWAY SUITE 111,ORLANDO FL, 32819 USATEL: +1 407-308-0099engineering@windmarhome.comThis item has been digitally signed and sealedby Miguel Alvarez on the date adjacent to theseal. Printed copies of this document are notconsidered signed and sealed and thesignature must be verified on any electroniccopies.R1 PHOTOVOLTAIC POWER SOURCEAC OPERATING VOLTAGE 240 VOLTSAC OPERATING CURRENT ______ AMPSMICROINVERTERS LOCATED UNDERNEATH PHOTOVOLTAICMODULES FOR SERVICE CALL URBAN SOLAR GROUP (888) 38-SOLARLABEL FOR PVC CONDUITLABEL SIZE : 4" X 2"NOTE: INSTALLER MUST FILL IN AC OPERATING CURRENTON LABEL. AC OPERATING CURRENT IS SAME AS NUMBEROF MICROINVERTERS IN THE CIRCUIT. EXAMPLE: IF ACIRCUIT CONTAINS 8 MICROINVERTERS, THEN THE ACOPERATING CURRENT IS 8 AMPS.PHOTOVOLTAIC SYSTEM ACDISCONNECTAC OPERATING VOLTAGE _____ VOLTSAC OPERATING CURRENT ______ AMPSLABEL FOR PV - AC SYSTEM DISCONNECTLABEL SIZE : 4" X 2"NOTE: INSTALLER MUST FILL IN AC OPERATING CURRENTON LABEL. AC OPERATING CURRENT IS SAME AS NUMBEROF MICROINVERTERS IN THE CIRCUIT. EXAMPLE: IF ACIRCUIT CONTAINS 8 MICROINVERTERS, THEN THE ACOPERATING CURRENT IS 8 AMPS.WARNINGSOURCES: UTILITY GRID ANDPV SOLAR ELECTRIC SYSTEMDUAL POWER SUPPLYPV SOLAR BREAKERDO NOT RELOCATETHIS OVERCURRENTDEVICELABEL FOR PRODUCTION / NET METER (BI-DIRECTIONAL)LABEL SIZE : 4" X 2"PHOTOVOLTAIC SYSTEMCOMBINER PANELDO NOT ADD LOADSLABEL FOR ENPHASE AC COMBINER BOXLABEL SIZE : 4" X 2"PHOTOVOLTAIC MICROINVERTERSLOCATED UNDERNEATH EACHPV MODULE ON ROOFTOP ARRAYLABEL FOR ENPHASE AC COMBINER BOXLABEL SIZE : 5-1/2" X 2"CAUTIONSOLAR POINT OF INTERCONNECTIONNOTE FOR ALL LABELS:LABELS SHALL BE UV RESISTANT AND SHALL HAVE WHITELETTERS ON A RED BACKGROUND. SHARPIE EXTREME OREQUIVALENT UV RESISTANT MARKERS SHALL BE USED FORWRITING ON LABELS REQUIRING INSTALLER-WRITTEN VALUES.LABEL FOR RAPID SHUTDOWNLABEL SIZE : 6" X 312 "NEC 690.56(C)(1)(a)LABEL FOR POINT OF INTERCONNECTIONLABEL SIZE : 4" X 2"LABEL FOR PV BACKFEED BREAKER CONNECTIONLABEL SIZE : 2" X 1"LABEL FOR SERVICE DISCONNECTLABEL SIZE : 4" X 1"SERVICEDISCONNECT____ AMPS AC ____ VOLTS ACWindmar Home407-308-00996753 Kingspointe Pkwy, Suite 111Orlando, FL 32819SOLAR INSTALLER INFORMATIONLABEL FOR Installer InformationLABEL SIZE : 5" X 2"ALLOWABLE LOAD: 56 PSFNOTE: INSTALL MID CLAMPS BETWEEN MODULES AND ENDCLAMPS AT THE END OF EACH ROW OF MODULES.ALUMINUM RAILS SHOULD ALWAYS BE SUPPORTED BY MORETHAN ONE FOOTING ON BOTH SIDES OF THE SPLICE.TOP VIEWALUMINUM ROOF MOUNTS MEASUREMENTSALUMINUM RAIL MEASUREMENTS SPACINGPORTRAIT ORIENTATIONLANDSCAPE ORIENTATIONSYSTEM ANCHORAGE SNAP N'RACKNOTE: LINE SIDE TAPMAX RATING MAIN SERVICE ENTRANCE CONDUCTOR SIZE(PV) AC DISCONNECT SPECIFICATIONS (MINIMUM 60 AMPRATED PER NEC 230.79 (D)TAP CONDUCTOR SIZE (MINIMUM 6 AWG COPPER OR 4AWG ALUMINUM PER NEC 230.42 (B) AND 310.15 (B) (7) OR310.15 (B) (16)CONDUCTOR ROUTING IN RACEWAY AND INSIDEPANELBOARD INCLUDING THE GROUNDED CIRCUITCONDUCTOR (NEUTRAL) PER NEC 300.3 AND 250.24 ©.TAP CONDUCTOR LENGTH LIMITATION OF 10 FEET PERNEC 105.31.GROUNDING AND BONDING CONNECTIONS FROM THE (PV)AC DISCONNECT CONNECTION TO THE SERVICEPANELBOARD, AND GROUNDING ELECTRODE CONDUCTORAS APPLICABLE.NOTE:ALL LOAD CALCULATIONS FOR THIS PANEL HAVE BEENDONE AND THIS CHANGE WILL NOT EXCEED CODE.NOTE:EXISTING METER WILL BE CHANGED TO A NET METER BYLOCAL UTILITY AFTER THE FINAL INSPECTION.NOTE:COMPLIANCE WITH NEC 250.58 ONLY ONE GROUNDINGELECTRODE FOR ALL ELEC. EQUIP. CONDUCTOR.NOTE:LINE SIDE TAP CONNECTION IN MDP WITH POLARIS TAPSBETWEEN ELECTRODE LOAD SIDE AND EXISTING MAINDISCONNECT.NOTE:LINE SIDE TAP CONNECTION IN MDP WITH BURNDYINSULATED CLAMPS BETWEEN ELECTRODE LOAD SIDEAND EXISTING MAIN DISCONNECT.NOTE:NEC 690.12 CODE COMPLAINTM. ALVAREZN.T.S.PARCS-2PROJECT :PROJECT NO.DATE:DRAWING BY:CHECKED BY:SCALE:SHEET TITLE:SHEET NO.ENGINEER'S SEAL2.11.2022PER FL STATUTE 377.705 (REVISED 7/1/2017), IMIGUEL ALVAREZ PE 86033 AN ENGINEERLICENSED PURSUANT TO CHAPTER 471,CERTIFY THAT THE PV ELECTRICAL SYSTEMAND ELECTRICAL COMPONENTS AREDESIGNED AND APPROVED USING THESTANDARDS CONTAINED IN THE MOSTRECENT VERSION OF THE FLORIDA BUILDINGCODE.PROPRIETARY RIGHTS DRAWING CONCEPT &DESIGNS ARE THE PROPERTY OF WINDMARAND IS SUBMITTED WITH THEUNDERSTANDING THAT IT IS NOT TO BEREPRINTED, COPIED, IN WHOLE OR IN PART,NOR LOANED TO ANY THIRD PARTY NORUSED IN ANY MANNER DETRIMENTAL TO THEINTERESTS OF WINDMAR WITHOUT ITSEXPRESSED WRITTEN CONSENT.SYSTEM LAYOUTSAFETY LABELSSCALE: NTSSYSTEM ANCHORAGESCALE: NTSSYSTEM ANCHORAGESCALE: NTSDAYLI FONSECA 192 NE CAPRONA AVE PORT ST. LUCIE, FL 34983DL2059 CONTACT US:6753 KINGSPOINTEPARKWAY SUITE 111,ORLANDO FL, 32819 USATEL: +1 407-308-0099engineering@windmarhome.comThis item has been digitally signed and sealedby Miguel Alvarez on the date adjacent to theseal. Printed copies of this document are notconsidered signed and sealed and thesignature must be verified on any electroniccopies. NOTES:1.THREAD MUST BE EMBEDED IN THE SIDE GRAIN OF A TRUSSES OR OTHER STRUCTURAL MEMBER INTEGRAL WITH THE BUILDING STRUCTURE.2.LAG BOLTS MUST BE LOCATED IN THE MIDDLE THIRD OF THE STRUCTURAL MEMBER.3.THESE VALUES ARE NOT VALID FOR WET SERVICE.4.THIS TABLE DOES NOT INCLUDE SHEAR CAPACITIES. IF NECESSARY, CONTACT A LOCAL ENGINEER TO SPECIFY LAG BOLT SIZE WITH REGARD TO SHEAR FORCES.5.INSTALL LAG BOLTS WITH HEAD AND WASHER FLUSH TO SURFACE (NO GAP). DO NOT OVER-TORQUE.6.WITHDRAWAL DESIGN VALUES FOR LAG SCREW CONNECTIONS SHALL BE MULTIPLIED BY APPLICABLE ADJUSTMENT FACTORS IF NECESSARY. SEE TABLE 10.0.1 INTHE AMERICAN WOOD COUNCIL NDS FOR WOOD CONSTRUCTION.UNIRAC ROOF ATTACHMENTLAG SCREW 516î12"MANUFACTURER: ECOFASTENSOLAR / MODEL: 18-LB-5/16X3-1/2PULL OUT CALCULATIONS FOR LAG BOLTSpruce, PinePer Inch Thread Depth266 Lbs3"473.77981.68Pull Out Strength = 266 Lbs x 3"SS Lag Bolt, 4 5/16"Maximuim Pull Out Strength Required Per BoltAllowable Pull Out Strength Per Bolt Lag Bolt Pull Out Strength Safety FactorMin. Thread DepthUNIRAC FLASHKIT PRO INSTALLATION DETAILSCALE: NTSM. ALVAREZN.T.S.PARCS-3PROJECT :PROJECT NO.DATE:DRAWING BY:CHECKED BY:SCALE:SHEET TITLE:SHEET NO.ENGINEER'S SEAL2.11.2022PER FL STATUTE 377.705 (REVISED 7/1/2017), IMIGUEL ALVAREZ PE 86033 AN ENGINEERLICENSED PURSUANT TO CHAPTER 471, CERTIFYTHAT THE PV ELECTRICAL SYSTEM ANDELECTRICAL COMPONENTS ARE DESIGNED ANDAPPROVED USING THE STANDARDS CONTAINEDIN THE MOST RECENT VERSION OF THE FLORIDABUILDING CODE.PROPRIETARY RIGHTS DRAWING CONCEPT &DESIGNS ARE THE PROPERTY OF WINDMAR ANDIS SUBMITTED WITH THE UNDERSTANDING THATIT IS NOT TO BE REPRINTED, COPIED, IN WHOLEOR IN PART, NOR LOANED TO ANY THIRD PARTYNOR USED IN ANY MANNER DETRIMENTAL TOTHE INTERESTS OF WINDMAR WITHOUT ITSEXPRESSED WRITTEN CONSENT.STRUCTURAL DIAGRAM&CALCULATIONS CONTACT US:6753 KINGSPOINTEPARKWAY SUITE 111,ORLANDO FL, 32819 USATEL: +1 407-308-0099engineering@windmarhome.comThis item has been digitally signed and sealedby Miguel Alvarez on the date adjacent to theseal. Printed copies of this document are notconsidered signed and sealed and thesignature must be verified on any electroniccopies.DL2059DAYLI FONSECA 192 NE CAPRONA AVE PORT ST. LUCIE, FL 34983 UNIRAC SM RAIL TABLESSCALE: NTSSOLAR PANELSARRAY WIND LOAD CALCULATIONSBASIC WIND SPEED (MPH)BUILDING HEIGHT (FT)EXPOSURE CATEGORYROOF PITCH17515TOTAL AREA (SQFT)CNOTE:RAILS SPAN FOR UNIRAC STANDARD SM RAIL IS ALWAYS GOING TO BEINSTALLED AT A MAXIMUM OF 4FT.NOTE:CALCULATIONS WERE PERFORMED AND PERTAIN TO UNIRAC SUPPLIEDPARTS ONLY. THIS CERTIFICATION EXCLUDES THE MODULE,CONNECTIONS TO THE BUILDING STRUCTURES, AND EFFECTS ON THEBUILDING STRUCTURE COMPONENTS. THIS ANALYSIS WASDEVELOPED ASSUMING A MEAN BUILDING HEIGHT OF LESS THAN OR EQUALTO 30 FEET. ALL INFORMATION, DATA AND ANALYSISCONTAINED WITHIN ARE BASED ON, AND COMPLY WITH THE FOLLOWING:1.2018 INTERNATIONAL BUILDING CODE, BY INTERNATIONAL CODECOUNCIL, INC., 20172.2020 FLORIDA BUILDING CODE, BY INTERNATIONAL CODE COUNCIL, FBC2020, 7TH EDITION.3.ASCE/SEI 7-16 MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHERSTRUCTURES, BY ASCE, 20154.2015 ALUMINUM DESIGN MANUAL, BY THE ALUMINUM ASSOCIATION,201528540.124.37/12ATTACHMENT INSTALLATION GUIDELINES1.LOCATE ROOF RAFTERS AND SNAP CHALK LINES TO MARK THE INSTALLATION POINTFOR EACH ROOF ATTACHMENT.2.DRILL A 7/32" PILOT HOLE AT EACH ROOF ATTACHMENT. FILL EACH PILOT HOLE WITHSEALANT..3.ADD A "U-SHAPED" BEAD OF ROOF SEALANT TO THE UNDERSIDE OF THE FLASHINGWITH THE OPEN SIDE OF THE "U" POINTING DOWN THE ROOF SLOPE.4.SLIDE THE ALUMINUM FLASHING UNDERNEATH THE ROW OF SHINGLES DIRECTLY UPSLOPE FROM THE PILOT HOLE.5.ALIGN THE INDICATOR MARKS ON THE LOWER END OF THE FLASHING WITH THECHALK LINE ON THE ROOF TO CENTER THE RAISED HOLE IN THE FLASHING OVERTHE PILOT HOLE IN THE ROOF.6.FASTEN L-FOOT AND FLASHING INTO PLACE BY PASSING THE LAG SCREW ANDPRE-INSTALLED STAINLESS STEEL EPDM WASHER THROUGH THE L-FOOT EDPMGROMMET, AND THE RAISED HOLE IN THE FLASHING, INTO THE PILOT HOLE IN THEROOF RAFTER.7.DRIVE THE LAG SCREW DOWN UNTIL THE L-FOOT IS HELD FIRMLY IN PLACE.ASCE 7-16 VELOCITY PRESSURE 15 ' MEAN ROOF HEIGHT ZONE 1 = 33.7 PSF ZONE 2 =56.6 PSF ZONE 3 = 56.6 PSF (NO MODULES)30 ' MEAN ROOF HEIGHT ZONE 1 = 51.7 PSF ZONE 2 = 75.3 PSF ZONE 3 = 75.3 PSF(NO MODULES)QZ10 = 0.00256*KZ*KZT*KD*V^2WHERE:QZ10 = ASCE 7-1 6 VELOCITY PRESSURE EVALUATED AT MEAN ROOF HEIGHT (PSF)KZ = VELOCITY PRESSURE EXPOSURE COEFFICIENTKZT = TOPOGRAPHIC FACTORKD = WIND DIRECTIONALITY FACTORV = BASIC WIND SPEED (MPH) FROM ASCE 7-16 MAPS REFERRED TO AS ULTIMATE WINDSPEED MAPS IN 2012 IBC.VELOCITY PRESSURE: QZ10 = 0.00256*0.85*1.0*0.85*175^2 N/M^2 = 56.6 PSF -CALCULATIONS FOR 15' MEAN ROOF HEIGHTDESIGN WIND PRESSURE: P = QZ10*G*CF = 56.6*0.85*0.70 = 33.7 PSFAS AN EXAMPLE, FOR AN ARRAY HAVING AN AREA OF 1,115 SQFT., THE TOTALUPLIFTING (RESULTANT) FORCE ACTING ON THE ARRAY WOULD BE 33.7 PSF X 1,115SQFT. = 37,575.5 LB. KNOWING THIS RESULTANT FORCE, THE DESIGN ENGINEER CANNOW DETERMINE THE NUMBER OF ATTACHMENT POINTS AND THE SIZE OF THEMOUNTING HARDWARE NECESSARY TO SAFELY CARRY THIS LOAD.LIVE LOADS:LIVE LOADS ASSOCIATED WITH PHOTOVOLTAIC SYSTEMS ARE USUALLY ASSUMED TOBE DISTRIBUTED UNIFORMLY AND ARE SMALL, ON THE ORDER OF 4 PSF OR LESS.M. ALVAREZN.T.S.PARCS-4PROJECT :PROJECT NO.DATE:DRAWING BY:CHECKED BY:SCALE:SHEET TITLE:SHEET NO.ENGINEER'S SEAL2.11.2022PER FL STATUTE 377.705 (REVISED 7/1/2017), IMIGUEL ALVAREZ PE 86033 AN ENGINEERLICENSED PURSUANT TO CHAPTER 471,CERTIFY THAT THE PV ELECTRICAL SYSTEMAND ELECTRICAL COMPONENTS AREDESIGNED AND APPROVED USING THESTANDARDS CONTAINED IN THE MOSTRECENT VERSION OF THE FLORIDA BUILDINGCODE.PROPRIETARY RIGHTS DRAWING CONCEPT &DESIGNS ARE THE PROPERTY OF WINDMARAND IS SUBMITTED WITH THEUNDERSTANDING THAT IT IS NOT TO BEREPRINTED, COPIED, IN WHOLE OR IN PART,NOR LOANED TO ANY THIRD PARTY NORUSED IN ANY MANNER DETRIMENTAL TO THEINTERESTS OF WINDMAR WITHOUT ITSEXPRESSED WRITTEN CONSENT.STRUCTURAL DIAGRAM&CALCULATIONSDAYLI FONSECA 192 NE CAPRONA AVE PORT ST. LUCIE, FL 34983DL2059 CONTACT US:6753 KINGSPOINTEPARKWAY SUITE 111,ORLANDO FL, 32819 USATEL: +1 407-308-0099engineering@windmarhome.comThis item has been digitally signed and sealedby Miguel Alvarez on the date adjacent to theseal. Printed copies of this document are notconsidered signed and sealed and thesignature must be verified on any electroniccopies.