HomeMy WebLinkAboutRenovation To An Existing PorticoGENERAL NOTES
All work shall comply with the strictest requirements of the State of Florida Building
Code and all applicable codes whether specifically stated or not.
All work shall conform with the strictest interpretation of State and Local codes,
lows, rules and regulations of all authorities having jurisdiction over the project,
whether specifically shown, or not.
Where the contract, construction notes or drawings call for any work of a more
stringent nature than that required by code or any other department having
jurisdiction over the work, the work of the more stringent nature called for by the
contract, construction notes or drawings shall be furnished.
The Contractor shall vist the site prior to submitting a bid. The Contractor will be
responsible for the verification of all dimensions and conditions. All discrepancies
shall be brought to the attention of the Architect before proceeding.
All drawings and notes are complimentary, and what is tailed for by either will be
binding as if called for by all. Any work shown or referred to on any one set of
drawings shall be provided as though shown on all related drawings.
The drawings are not to be scaled at any time. Only written dimensions and notes
are to be used. All dimensions are given to finishes. All dimensional discrepancies
shall be immediately brought to the attention of the Architect. All dimensions shall
be verified before starting work by the respective Contractor, who shall be held
responsible for his phase of the work.
All "Plus -Minus" dimensions are provided in situations where existing conditions
exist. Such dimensions shall be verified in the field by the Contractor.
All work listed on the construction notes sheets and shown or implied on all
drawings shall be supplied and installed by the Contractor, unless otherwise noted.
The Contractor shall notify the Architect in writing immediately if he cannot comply
with all notes contained within the Contract Documents.
The Contractor shall notify the Architect in writing immediately of any discrepancies
between the drawings, the notes and field conditions before commencing any work
to request clarification.
The Contractor shall be responsible for all damage to existing property as a result
of his work, his workmanship and subcontractors. The Contractor shall provide
adequate protection for his work, and shall be responsible for the same. The
Contractor shall restore to original condition and existing element damaged as a
result of his work.
Where a product is specified by a particular manufacturer, the Contractor shall
furnish and install the product in accordance with the strictest specifications set
forth by the manufacturers best standards.
The General Conditions of the contract for construction of Buildings, the Standard
form of the American Institute of Architects (AIA), latest edition of Form A-201,
inclusive as it pertains to this project, are part of these Contract Documents.
Work included in this conract shall be all labor, material and equipment required to
complete the proposed construction as shown or inplied in the Contract Documents.
Work included in this contract shall be according to the true intent of these
drawings and shall be first class in all respects.
The Contractor is responsible for dimensions to be confirmed and correlated at the
job site and for information that pertains to the fabrication process, and/or to
techniques for construction and coordination of the work of all trades.
The Architect shall be the sole judge as to the adequacy of any work performed.
The Architect shall have the right to order the removal of defective work and
material, and its replacement without any additional cost to the Owner.
All work to comply with governing State and Local Building Codes.
All plumbing to comply with governing State and Local Plumbing Codes.
All Electrical work to comply .with governing National and Local Electrical Codes.
The Contractor shall assume full responsibility for the confirmation of actual field
dimensions as they pertain to the fabrication and installation of any materials
and/or equipment requiring such.
The General Contractor shall excercise strict control over job cleaning to prevent
any debris, dust or dirt from leaving the job site and adjacent finished areas.
The Contractor shall properly protect all adjoining property or work or work and
any damage to the some caused by his work or workmen must be made good
without delay. Patching and and replacing or damaged work shall be done Dy the
Contractor who is responsible for the damage.
The Contractor shall provide all necessary protection for his work until it is turned
over to the Owner.
The Construction Drawings and/or notes are supplied to illustrate the design and
general type of construction desired and are intended to imply the finest quality
construction materials and craftsmanship throughout.
The Contractor, upon acceptance of these drawings, assumes full responsibility for
the construction, materials and workmanship of the of the work described in these
notes and drawings, and he will be expected to comply woth the spirit, as well as
with the letter in which they were written and drawn.
Controlled tests required by those having jurisdiction over the project shall be
executed and paid for by the Contractor.
Patching and Cutting:
The General Contractor shall survey all existing finished surfaces to include
comer beads, stops, existing construction to remain, etc. for chips, cracks,
holes, damaged surfaces and any other surfaces and defects causing an
appearance different from a new finished first-class installation. These
defective surfaces shall be repaired, or if beyond repairing, then the General
Contractor shall remove existing and install new surfaces to the satisfaction
of the Architect.
Construction:
All wood framing members shall be select structural grade Douglas Fir in
accordance with the latest edition of A.I.T.C. Design specifications for stress ,3rade
lumber. Minimum E=1,4000,000; f=1400.
All landings to be in accordance with RCNYS R311.5.4 for stairways and Rat 1.4.3
for exterior doors.
Unless otherwise specified in these documents, all openings in wall shall receive
(2)2x12 wood headers. This includes, but Is not limited to, all doors and
windows.
All walls and ceilings shall receive 1/2" thick, tapered edge gypsum wall board,
except Bathrooms, which shall receive 1/2" thick moisture resistant wall board
and/or 1/2" thick "Wonderboard", in accordance with finishes selected by the
Owner. Such variations shall be coordinated by the Contractor with the Owner.
All interior surfaces shall be taped three (3) times and sanded smooth for
paint.
All windows, doors and transition spaces (i.e. openings without doors) shall
receeve a paint grade colonial wood trim as selected by the Owner, and
approved by the Architect
All interior walls and ceilings shall receive 1 coat of latex primer and two
coats of latex flat finish house paint. Colors as selected by the Owner.
Paint as manufactured by "Benjamin Moore', or approved equal.
All interior wood trim shall receive 1 coat of latex primer and 2 coats of latex
semi -gloss flat finish trim paint. Colors as selected by the Owner. Paint as
manufactured by "Benjamin Moore", or approved equal.
All exterior wood shall be painted. All surfaces shall receive 1 coat of exterior
oil primer, and 2 coats of exterior oil house or trim paint. All surfaces shall
receive a 'White" finish. Paint as manufactured by "Benjamin Moore", or
approved equal.
All existing exterior wood trim shall be painted. All surfaces shall receive 1
coat of exterior oil primer, and 2 coats of exterior oil house or trim paint.
All surfaces shall receive a "White" finish. Paint as manufactured by 'Benjamin
Moore", or approved equal.
New asphalt roofing to shall match the existing in color in size. Contractor to
summit sample to the Owner for they appoval.
Insulation as manufactured by Owens Corning. Thickness as specified in
drawings.
Unless otherwise noted, all dimensions for partitions are from finish
material -to -finish material.
All flashing shall be aluminum or copper, unless specified otherwise.
Asbestos Removal:
The Architect shall not be responsible for the uncovering of, or identification
thereof, any asbestos, asbestos -related materials, lead, lead -paints or any other
pollutants of any kind. The Architect is not responsible for the perforamance of
any services in connection with or related to such materials, and the Contractor
shall retain an expert(s) to arrange for the prompt identification of, and the
removal or treatment of such potentionally harmful materials, and indemnify and
hold the Architect and its consultants harmless from any claims, injuries or
expenses incurred by Architect in any manner related to the existence of such
materials on the project.
Firestappena
Firestopping consisting of 2' lumber, minimum 23/32" structural panel or
approved non-combustible materials shall be provided at the ceiling line in
concealed spaces of stud walls/partitions, including furred or studded -off spaces
of concrete foundation walls and at soffits, dropped ceilings and similar spaces.
CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA
GROUND
WIND DESIGN
SEISMIC
SUBJECT TO DAMAGE FROM
WINTER
ICE SHIELD
FLOOD
SNOW
LOAD
DESIGN
DESIGN
UNDERLAYMENT
HAZARD'.
WIND
TOPOGRAPH.
SPECIAL
IND-BORNE
FRp
SPEED
EFFECTS
WIND REG.
DEB. ZONE
CATEGORY
WEATHERING
PTUNE
TERMITE
DECAY
TEMP
REQUIRED
N/A
160
N/A
NEGLIGIBLE
N/A
VERY
I ---
N/A
N/A
--
HEAVY
CODE INFORMATION
11'PE
APPLICABLE CODES
ARCHITECTURAL
2017 FLORIDA BUILDING CODE
ENERGY
2015 ENERGY CONSERVATION CONSTRUCTION CODE
CATEGORY
REQUIREMENT
REFERENCE
CLASSIFICATION OF WORK
ALTERATION - LEVEL 2
ADDITION
SECTION A1304
SECTION AI306
OCCUPANCY CLASSIFICATION
GROUP R2 - APARTMENT
SECTION 310
CONSTRUCTION CLASS.
TYPE 5B - WOOD FRAME
SECTION 601
PRODUCT CODE: FL1654—R26
SYSTEM 11 W-207
PATCH EIFS--
AS REQ.
FLASHING 0 ROOF —
WAU.INTERSECTION
PCLYF.a Pry & STID
r OSB MR SHEA111INGG
TO CREATE ROOF PITCH
FLASHING —
EIFS ON WIRE LATH 0
DENSGLASS ATTACHED
TO PT. WD. FURRING
HURRICANE CUPS AS
REQ. SEE CHART FOR
FASTENING RFD.
GALVANIZED STRAPP
SIMPSON }CMST4
(2 EACH COLUMN)
w/3' CONCRETE SC
2" x 4' WOOD _
FRAMED @ 16' O.C.
IX. COLUMN CAPITAL
TO REMAIN
LINE OF ARCHED --
OPENING
SOFFIT VENT ---
UNE OF COLUMN --
BEYOND
I DESIGN FLOOR LOADS
ROOF 40 LBS LIVE LOAD I
DESIGN
PRESSURE
ROOF
ZONE 1- 36.2
ZONE 2- 53.9
ZONE 3-- 101
DOOR
ZONE 4- 47.9
ZONE 5- 57.5
TO RAFTER FOR
ROOF PITCH
2xB R.R. EPIACED AND/OR
REPNRED RED.
II
PRE -MANUFACTURED
SS BY KOST TRUSS,
INTR (TYP)
O
2" J 4"
I
ALL BEYOND/
APPROXIMATE SAW -CUT
LINE OF EXISTING EIFS.
� ,PATCH AS REQUIRED
I
IFS ON WIRE LATH ON
ENSCIASS ATTACHED
ITO PI. WD. FURRING
I
i
@
@ @
B
u
n .
u
•
• .
a •
O
H7a
m
H25A
1. n
t. wns Iww emt saw.�s m so esr rtw rwrnwrxr a rs Iaus trm ro
Hanes eroEn� wtmm.
z wwawtE uvss xa rm a.: sxtrm a w serre taaoe� ff a ,n war
M w®!Ex MMPa& OAE NSPMIED WI E4N �E ff RE JmT ND al! SIC SIZE
ME OF n¢ netr.
IE
SIMPSON STRONG -TIE, SEISMIC/ HURRICANE TIES
rastoEaw
enwrs
REPAIR EIFS �
ON WALL AS REQ.
NOTE:
SHOP/DESIGN DRAWINGS BY T. STILES PELT, PE IS AN
INTEGRAL PART OF THESE PLANS.
TOP CHORDS: 20 SP 12
BOTTOM CHORDS: 20 SP 12
WEDS: 2x4 SP #3
TRUSSES
TO BE INSTAIJkO TOP CHORD UP PATCH
AS REQ,
2 2 z4" BLOCKING
ATTACH TO WALL
Iw/ D�' x 5-1/2° HILT]
IFS
DFS ON WIRE LOTH ON CONCRETE ANCHORS FLASHING 0 RODE —
IN FIAT" DENSGIASS ATTACH® I WALL INiBtSECfTON
TO PT, WD. FURRING
DLTAIL I POLYFIiX PEEL &SRC
ROOF INSTALLED PER
— — — — — — - MANUFACTURER
TAPERED INSULATION -
SLOPE 11/4° PER FOOT
FLASHING
EIFS ON WIRE LATH ON
DENSGLASS ATTACHED
LINE OF EXTERIOR TO PT. WD. FURRING
WAIT
OVERHANG DETAIL
SCALE: 1/1"=1'-0"
4
WALL BEYOND/
GALVANIZED STRAPPING
SIMPSONCMSi14 !
(2 EACH COLUMN)
w/3" CONCRETE SCREWS
TRUSS SUPPORT
LINE OF EX.
OVERHANG
EXISTING 16"
CONCRETE COLUMN
amPRODUifcrs CIME R.1854-R26
PRODUCT CODE: FL1654—R26
SYSTEM # W-207
AREA OF
SCALE: N.T.S
FACE OF ARCH. _
(ATTACHED TO TRl
EIFS ON EXPOSED
AN D
7REPLACE W/SAME
EIFS FINISH ON
ARCHED OPENING ABOVE
TRUSS HEADER TO BE
REMOVED AND REPLACED
POSED FLOOR PLAN
SCALE: 3/4"=1'-0
WORKCn
w
Crx
Of
U
~
o
w
Z
lV
J
1-I
w
Z
W
— U
`TRUSS BY T. STILES PER PE
SEE SHOP CUTS I
EIFS ON WIRE LATH ON !
DENSGLASS ATTACHED I
TO PT. WO. FURRING I
2x4 W000 FRAMED
ARCH WITH }° OSB MR
SHEATHING
EXIST.
COLUMN
CAPITAL TO REMAIN
SECTION
1 SCALE: 1/2"=1'-0"
✓ 0 p:
h
a; Lu ¢;
co
a 0
Z;
o E- rt� .
j �
ti i
U
4.1
f .®I fl
03
VJ
COUIVil' OF S7 LUCRE
00
PERMIT NUMBER: 2005-0558