Loading...
HomeMy WebLinkAboutBoundary SurveyLB #6810 0.43' N OF R/W LINE 79 SWL l�_�Y_ SWL - EP '6' 42ryti 2.71 SECTION LINE (TM) CL 9h _WEATHERBEE ROAD �3O (R/wVARIE5)(21' ASP) _ SWL ,• irvv lv.° _ TOR o -OHE- - �OH o3 2 5 89°56' 47" E 458.56' (M) 'r9 6 CLF 1ry� NV 1 AArq FND 3"X3" CM FNC COR N 90°00'00" E 200.44' M N 90°00' 00" E 458.65' (TM) NO ID 0.50' 5, 0.64' E (,) CONC ET PK TP N 90000' 00" E 200.50' (TM) 6q BM EL 13.1 BEARING BASIS GATE z' U �0 9D0 41 1 GREEN AREA 290 LOT 6 WEST 7.0 ACRES (VACANT) NOT INCLUDED bh NE CORNER LOT 6 WHITE CITY SUBDIVSION 27EP o N 90000'00" E 617.38'(M) swL o R/W LINE AS FIELD MEASURED AND IN USE N 90000'00" E 617.15' ( TM ) FND 5/8"R/GILL ON R/ W LINE y TOB FND 3' X3" CM 95.00 (TM) FND 3"X3" CM 95.00 (M) FND 3"X3" CM 90.00 (TM) FND 3"X3" CM 100.00' T ( M) NO ID FNC COR 95.66' (M) NO ID ON R/W LINE 95.00' (TM) NO Ib 0.12' N OF R/W LINE 90.17 (M) NO ID ON R/W LINE , 99.47 (M) 0.90' 5, 0.77' W y9 � 0 �ST � � N 1AS GREEN AREA W q J �NF v V FENCE 0.1' CLEAR o NO 1,Z0 O Z O LOT 5 (ALL OCCUPIED) V FND 5/8" RIC #2391 237.15' (TM) 237.09' (M) x 6' CLF � v FNC COR ASP 2.20' E. OF P/L O\ 10 13' X 28.85' LOT 6 `D 1 STORY CBS BUILDING WEST 7.0 ACRES ^ 17771 v J U N CONC �1 ry �Y' S PKPK TP BLDG FLOOR EL 12.79 8.60' � BM EL 13.28 ° • 3 ^ F- - N ASP w ~ V -- _ N v_ h >2� FNC COR d 1.62' E. OF P/L 0 :0 z ¢S j 6' CLF Ch O O a d- 1•y� .p Z o 0 �O vi GRAVEL GREEN AREA a -------47.37' Z O LL a- ABBREVIATIONS LEGEND °� ASP X 9 0 5' RAMP PROP 4' X 24' ryFENCE0.4'CLEAR UNSUPPORTED 5.5. SANITARY SEWER ^� - OVERHANG A/C AIR CONDITIONING INT INTERSECTION 5PC STATE PLANE COORDINATES 9 a 00 80.13' • AL ACRE INV IP INVERT IRON PIPE 5T SEPTIC TANK ,N., try' AL ANC ALUMINUM ANCHOR IP&P IRON PIPE&PLUG STD STANDARD 60.00' A ,L9 h AP ANCHOR POLE IR IV IRON ROD STU SV STORY SANITARY VALVE 1 GATE m ASP APPROXIMATE ICV IRRIGATION VALVE SWL SWALE 60.25'V,1' ,�q p ASP ASPHALT IRRIGATION CONTROL VALVE TA TOP OF ASPHALT 1-y� �p- BE BUFFER EASEMENT IW IRRIGATION WELL TM TAX MAP PROP ADDITION CONC BFP BACK FLOW PREVENTOR L LB LENGTH LICENSED BUSINESS TMH TELEPHONE MANHOLE I BLDG BILK BUILDING BLOCK LFST LIFT STATION TOR TOP OF BANK CONC FLOOR EL 13.04 BM BENCHMARK LME LAKE MAINTENANCE EASEMENT TOE TP TOE OF SLOPE TRAVERSE POINT COV BOC BACK OF CURB LOC LP LOCATION LIGHT POLE TR TELEPHONE RISER CONC 9.36' BP Bow BRICK PAVERS BACK OF WALK L5 LICENSED SURVEYOR TRANS TRANSFORMER BRG BEARING M MEASURED TSB TT TRAFFIC SIGNAL BOX TIN TAB 4 BW BARBED WIRE - MAX MAXIMUM TOWNSHIP IP CO 12 C&G CURB AND GUTTER MB MAIL BOX TYPP AL Z W A C&T CULPEPPER4 TERPENIN6 MEAS ME5 MEASURED MITERED END SECTION U/C UNDER CONSTRUCTION ry 0. ry CS 1 STORY CBS o g N C/0 C CUT OUT CALCULATED MH MAN HOLE U.E. UP UTILITY EASEMENT UTILITY POLE ry o BUILDING m I CAN CABLE TELEVISION BOX MHWL MEAN HIGH WATERLINE UR UTILITY RISER (NO ROOF) ,�-, CB C85 CATCH BA5IN CONCRETE BLOCK STRUCTURE MN MINIMUM MAGNETIC NAIL UW VC UNDER WATER VALLEY CURB LHD CHORD MIT MITERED END VLT VAULT GRAVEL CI CURB INLET '., MW MONITORING WELL wo WOOD CL CENTERLINE M&B METES AND BOUNDS WL WATERLINE CLF CHAIN LINK FENCE N&D NAIL AND DISK wM WATER METER O ll CM CONCRETE MONUMENT N NA NAIL NON -APPLICABLE WP WELL POINT Z 12' O CMP CO CORRUGATED METAL PIPE CLEAN OUT NAVD NORTH AMERICAN VERTICAL DATUM WPP WOOD POWER POLE O COR CORNER NGVD NATIONAL GEODETIC VERTICAL DATUM w5 WV WATER SERVICE WATER VALVE CONC CONCRETE NGS NATIONAL GEODETIC SURVEY o CONST CONSTRUCTION NOT SCALE m CEE COVERED CIA CIA OVERALL C COVERED ENTRY O OFFSET 60.02' 60.05' COVP COVERED PORCH OE OVERHEAD EASEMENT CPP CONCRETE POWER POLE OHE OVERHEAD ELECTRIC 1 CPPIPE CORRUGATED PLASTIC PIPE CHU OVERHEAD UTILITYCONCRETEOR 1q,. OFFICIAL RECORD POP L ROADING PAD 0 DELTA ANGLEAB ORB OFFICIAL RECORD BOOK D/F DRAIN FIELD P/C PROPERTY CORNER D DEED INFORMATION P/L PROPERTY LINE P PAVE PLAT PAVEMENT D.E. DRAINAGE EASEMENT PB PLAT BOOK 2a DI DIA DROP INLET DIAMETER pL POINT OF CURVATURE O b 1ry' _ m ,L2� p DIP DUCTILE IRON PIPE PCC PCO POINT OF COMPOUND CURVATURE PRESSURECLEAN OUT (SANITARY) DMH DUE DRAINAGE MANHOLE DRAINAGE 6, UTILITY EASEMENT PCP PERMANENT CONTROL POINT GREEN AREA N 3 O EC EDGE CONCRETE PF PG PLASTIC FENCE PAGE � v � ECP ELECTRICAL CONTROL PANEL pI POINT OF INTERSECTION % EL ELEC ELEVATION ELECTRIC PRKG PARKING FNC COR FNCOR = ELEV ELEVATION PK&D PK/TT PARKER KALON NAIL AND DISK PARKER KALON NAIL AND TIN TAB TOR 20" N, 2' E 6' CLF $ TOR 16.65' N EM ENC ELECTRIC METER ENCROACHMENT PLS PROFESSIONAL LAND SURVEYOR * x x x . x x 8.8T W TOR EOW EDGE OF WATER POB POINT OF BEGINNING SWL 70 `'7 _ '�2� -i2"RCP EP EDGE OF PAVEMENT POC POINT OF COMMENCEMENT ' 459.10 (TM) I W_INV 11.05 5WL IO ESB ELECTRIC SERVILE BOX PP PRL POWER POLE POINT OF REVERSE CURVATURE TOB/FL Y1P qQ> x x 12. E INV 11.10 2.5 TOR ESMT EX. EASEMENT EXISTING PRO PRORATED DISTANCE __jFND 3"X3" CM 6' CLF COR 5 89°56' 57" W 200.67' (M), 200.50' (TM) 6' CLF COR FND 3"X3" CM EXT EXTENDED PROP PRM PROPOSED PERMANENT REFERENCE MONUMENT NO ID 3.0' N, 1.9' E 0.8' N, 2.1' W NO Ib FNC FC FENCE F" CURB P5M PROFESSIONAL SURVEYOR &MAPPER FDC FIRE DEPARTMENT CONNECTION PSWL PLASTIC SWALE FECRR FLORIDA EAST COASTRAILROAD PT P.U.E. POINT E TANGENCY PRIVATE EASEMENT FFE FINISHED FLOOR ELEVATION PVC POLYVINYL CHLORIDE LCHLO FH FIRE HYDRANT R/C ROD AND CAP FND FOC FOUND FACE OF CURB R/W T-OF -WAY RF-W FOW FACE OF WALK R RCP RADIUS REINFORCED CONCRETE PIPE LOT COVERAGE: FL FENCELINE RGE RANGE LOT 9 LOT 10 LOT CONTAINS 129,280 SQUARE FEET GA GREEN AREA RLS REGISTERED LAND SURVEYOR (VACANT) EXISTING BUILDING 1 CONTAINS 7,739 SQUARE FEET GMH GAS MANHOLE RP RADIUS POINT (VACANT) EXISTING BUILDING 2 CONTAINS 375 SQUARE FEET GND &RD GROUND GRINDER RR RAILROAD EXISTING CONCRETE ( INCLUDES COVERED AREAS, DRIVE AND PADS) CC iNTAIN 2,650 SQUARE FEET HC HEADER CURB RRS S/w RAILROAD SPIKE SIDEWALK EXISTING ASPHALT PARKING AND DRIVE CONTAIN 9,189 SQUARE FEET HCP HIGH SMH SANITARY SEWER MANHOLE PROPOSED BUILDING CONTAINS 8,580 SQUARE FEET HDPE HGw HIGH DENSITY POLY THYLENE DENSITY HOG WIRE SBT SOUTHERN BELL TELEPHONE PROPOSED LOADING PAD CONTAINS 360 SQUARE FEET HW HEADWALL SEC SF SECTION SQUARE FEET HYD HYDRANT SHP SHIP SPIKE OR BOLTONTR ICV IRRIGATION CLVALVE SLCR 5T LUCIE COUNTY RECORDS ID IDENTIFICATION SLP STREET LIGHT SUPPORT POLE ILL ILLEGIBLE PARCEL LEGAL DESCRIPTION: ALL OF LOT 6, LESS THE WEST 7 ACRES THEREOF OF THE SUBDIVISION OF WHITE CITY IN SECTION 3, TOWNSHIP 36 SOUTH, RANGE 40 EAST, AS PER PLAT OF SAID SUBDIVISION ON FILE IN PLAT BOOK i AT PAGE 23, OF THE PUBLIC RECORDS OF SAINT LUCIE COUNTY, FLORIDA, EXCEPTING THEREFROM ALL RIGHTS OF WAY FOR DRAINAGE CANALS AND PUBLIC ROADS. ADDRESS: 501 WEST WEATHERBEE ROAD FORT PIERCE, FLORIDA NOTES: SUBJECT TO ANY APPLICABLE EASEMENTS, RIGHTS -OF -WAY, OR OTHER RESTRICTIONS OF RECORD. A SEARCH OF THE PUBLIC RECORDS HAS NOT BEEN MADE BY THIS OFFICE. BEARINGS SHOWN ARE ASSUMED AND RELATED TO THE SOUTHERLY RIGHT OF WAY LINE OF WEATHERBEE ROAD. ELEVATIONS ARE IN FEET AND RELATED TO NGS BENCHMARK DESIGNATION " Y 403", HAVING A PUBLISHED ELEVATON OF 13.44 FEET NORTH AMERICAN VERTICAL DATUM OF 1988. LEGAL DESCRIPTION FROM WARRANTY DEED RECORDED IN OFFICIAL RECORD BOOK 3677, PAGE 444, SAINT LUCIE COUNTY PUBLIC RECORDS. PROPERTY LIES IN F.I.R.M. ZONE "X", AS SHOWN ON MAP NUMBER 12111CO189K, DATED 02/19/2020. FLOOD ZONES ARE APPROXIMATE AS SCALED FROM FLOOD INSURANCE RATE MAPS. IN ACCORDANCE WITH CHAPTER 5J-17.051, ADDITIONS OR DELETIONS TO SURVEY MAPS OR REPORTS BY OTHER THAN THE SIGNING PARTY, IS PROHIBITED WITHOUT WRITTEN CONSENT OF THE SIGNING PARTY. UTILITIES SHOWN HEREON ARE VISIBLE ABOVE GROUND FEATURES. ADDITIONAL SUBSURFACE UTILITIES AND OR FEATURES MAY EXIST. THERE MAY BE ADDITIONAL RESTRICTIONS THAT ARE NOT SHOWN ON THIS SURVEY, THAT MAY BE FOUND IN THE PUBLIC RECORDS OF ST. LUCIE COUNTY, FLORIDA. NOT VALID WITHOUT THE SIGNATURE AND THE ORIGINAL RAISED SEAL OF A FLORIDA LICENSED SURVEYOR AND MAPPER. THE EXPECTED USE OF THE SURVEY AND MAP IS COMMERCIAL. ALL MEASUREMENT5 ARE IN ACCORDANCE WITH THE UNITED STATES STANDARD IN FEET. COORDINATES WERE ESTABLISHED BY GLOBAL NAVIGATION SATELLITE SYSTEM (GNSS) USING REAL TIME KINEMATICS (RTK) USING FLGRIDA DEPARTMENT OF TRANSPORTATION - FLORIDA PERMANENT REFERENCE NETWORK (FDOT-FPRN), WITH REDUNDANCY OF MEASUREMENTS PERFORMED. HORIZONTAL ACCURACY IS 0.03 FOOT PLUS OR /"ANUS. BOUNDARY FIELD DATE: FEBRUARY 27, 2015. UPDATE SURVEY FIELD DATE: 07-24-19. PLATTED AREA CONTAINS 3.06 ACRES. MONUMENTED AREA CONTAINS 2.97 ACRE. CERTIFIED TO: GARY WHIGHAM LEGEND = POSTED SIGN EST = BELL50UTH TELEPHONE RISER = LIGHT POLE = BELLSOUTH TELEPHONE MANHOLE -0 = WOOD POWER POLE © = GREASE TRAP WPB Fil = WIRE PULL BOX TS = TRAFFIC SIGNAL BOX BFP = BACK-FLO%V PREVENTOR D = DCV DOUBLE DETECTOR CHECK VALVE WM ■ = WATER METER FDc FIRE DEPARTMENT CONECTOR wV D4 - - WATER VALVE _ FN - FIRE INDICATOR P05T = FIRE HYDRANT E� = ELECTRIC METER co = CLEAN OUT GV= GAS VALVE ®= CURB INLET TYPE 6 = CATCH BASIN i FROND QS = SANITARY MANHOLE © = MITERED END SECTION SIDES AODRAINAGE MANHOLE ❑ = NCNR CONCRETE POWER POLE aR YARD DRAIN EO ELECTRIC SERVICE BOX I 0 = IRRIGATION VALVE ® = AIR RELEASE VALVE CV = IRRIGATION CONTROL VALVE Pa = SANITARY VALVE EXISTING SPOT ELEVATION O = CONCRETE POWER POLE ROBERT F. KEMER50N PROFES;5IONAL SURVEYOR AND MAPPER ST,ITE OF FLORIDA (P5M)#6285 aad3,d 5�, O Z N H V'j J 10 ix j DWI °m W Z ZH 0� M 1` ^o u a or_ H Z 2� N�0Nt o' rnu H1"'I CoCA ]L LL > N 3 Z �o�v3 W>�LJZ� Z 0 o °o1 3: �L o J LU r w U Z �I V > m iI m ¢Ih Z z Lo o Loi,� w Z a Z 1 O w OI,m ce N o � m m 0 � o F m m a � o 0 0 0 a Y m co -6 m ti m � I DRAWN BY: G. SANTOIEMMA APPROVED BY: R. KEMER50N SCALE: 1" = 40' 03/03/15 FIELD BOOK/PAGES o PLANS ; JOB NUMBER: 19-2123 SHEET: 1 OF 1 NAProjects\2019\19-2123 Whigham - Weatherbee\19-2123 BNDY 5URVEY.dwg, BOUNDARY, 5/20/2020 11:19:42 AM, Veicon Group, Inc., (7725) 879-0477