HomeMy WebLinkAboutLetter (Civil Engineering)Paul Welch, Inc.
anical * Electrical * Civil Engineering
1984 SW Biltmore St. #114
Port St. Lucie, FL, 34984
(772) 785-9888
PAUL WELCH, PE FLA REG. NO. 29945
Address: 501 W Weatherbee Rd.
Permit Number: 2003-0567
Contractor: Telese Builders, LLC
LIGHTING DENSITY AUDIT
2017 Florida Building Code: Energy Conservation 6th Edition
Section C405
SPACE BY SPACE METHOD
Table 0405.4.2(2)
SPACE TYPE: Storage Area
2,640 watts / 8,472 s.f. _ .31
SPACE TYPE: Restroom
100 watts / 54 s:f. _ .54
LIGHT FIXTURES
Allowable L.P.D. (watts per sq. ft.): 0.63
Provided L.P.D. (watts per sq. ft.): 0.31
Allowable L.P.D. (watts per sq. ft.): 0.90
Provided L.P.D. (watts per sq. ft.): 054
LED Flouresent Shop Lights (440 watts) each.
Exhaust fan & Light (100 watts) max.
EXTERIOR LIGHTING ZONES
Table C405.5.1.0 )
Lighting Zone: 2
i
f
fviAY 2 020
i
ST, Lucie County, Permitting
INDIVIDUAL LIGHTING POWER ALLOWANCES FOR BUILDING EXTERIORS
Table C405.5.1.(2)
Base Site Allowance: (Zone 2) = 600 watts
BUILDING ENTRANCES & EXITS
Main Entry: (20 watts / foot of door width)
6.0' door width x 20 watts = 120 watts
Other Doors: (20 watts / foot of door width)
9.0' door width x 20 watts = 180 watts
Entry Canopies: (.25 watts / sq. ft.)
96.0 s.f. x .25 watts = 6.50 watts
Total Exterior Power Allowance (watts): 306.5 watts
MINIMUM PERFORMANCE OF WATER HEATING EQUIPMENT
Table C404.2
SIZE (Input): <12kW Rating Condition: Resistance Performance Required: 0.97-0.00 132V, EF
SIZE (Input): 2.OkW Rating C dition: Resistance Performance Required: 0.00 EF
PAUL WELCH, PE
FLA REG. NO. 29945 MAY 1, 5 2020