Loading...
HomeMy WebLinkAboutREVISION, Revised Duct Drawing 2.23.22 (2)Job #: 1480 Performed by Chris Bateman for: Hernandez Residence 5802 Birch Dr Ft. Pierce, FL 34982 Air Calcs, LLC 7550 Hidden Hammock Ln Vero Beach, FL 32966 Phone: 772.800.8413 vickilynne@aircalcs.com Scale: 1 : 107 Page 1 Right-Suite® Universal 2021 21.0.11 RSU29066 2022-Feb-22 15:18:41 ... HVAC\5802 Birch Dr PSL Prop.rup N Level 1 Garage WIC Laundry Hall Master Bed Master Bath Foyer Bed 3 Bed 2 Bath Lin Hall 2 Living Room Pantry Kitchen 10 x 6 63 cfm 10 x 6 55 cfm 8 x 8 97 cfm 8 x 8 97 cfm 12 x 8 149 cfm 12 x 8 207 cfm H/W14 x 14 207 cfm 16 x 16 8 x 8 59 cfm 4 " 6 " 80 CFM 4" Duct 4"Exhaust Vent 120 CFM 6" Duct 6"Exhaust Vent 10 x 6 77 cfm 10 x 10 199 cfm 12 x 12 149 cfm 10 x 10 149 cfm 10 x 10 149 cfm 30 x 18 886 cfm 10 x 10 170 cfm 10 x 10 170 cfm 14 x 14 218 cfm 14 x 14 16 " 16 " 6 " 5 " 6 " 6 " 12 " 7 " 7 " 10 " 4 "5 " 5 " 5 " 7 " 5 " 8 " 10 " 12 " 12 " DUCTS IN THE GARAGE AND DUCTS PENETRATING THE WALLS OR CEILINGS SEPARATING THE DWELLING FROM THE GARAGE SHALL BE CONSTRUCTED OF A MINIMUM NO. 26 GAGE (0.48 MM) SHEET STEEL, 1 INCH MINIMUM RIGID NONMETALLIC CLASS 0 OR CLASS 1 DUCT BOARD, OR OTHER APPROVED MATERIAL AND SHALL HAVE NO OPENINGS INTO THE GARAGE