Loading...
HomeMy WebLinkAboutProduct Approval Exterior Doors�i�_ ,,�'��'��L: ice: �•'�' •" ISCiS Nnn:: Lcg In -UM Registralmn 4 ?'rcoiG; Su'a:hit Surcnaf4e Stars 9 Wts I uPK2t 0% Contact us acts Sitc Hap un's Search d b,. r ! �ls Product Approval `iwn USER: Puo[!c IJset Fi�e®y Vlpt k Arg.<n l M-!j o- arn,",)cr or gp> A�p�• :ia� , •^ > Application Detail FL T FL16650 R7 Application Type 'Revision , Code Version ' 2020 Application Status Approved CODE COMPLIANCE Comments ST. LUCIE COUNTY Archived diOCC 211�1,Q Product Manufacturer Haas Door Company Address/Phone/Email Wauseon. caore St. 57 RECEZv�� (419) 337-900D 'Ext 243 mschweitzer,ohaasdoor.com, 4 Authorized Signature Mark Schweitzer pepa t� 9 msch.veitzer[haasdoor,com Pet�ttC`g `P ra St. Technical Representative Ad dress/Piion a/Em ail Quality Assurance Representative Address/Phone/Email Category Exterler Doors Subcategory Sectional Exterior Door Assemblies Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professlonal Engineer _valuation Report - Hardcopy Received Florida Engineer or Architect Name who developed the John E. Scates Evaluation Report Florida License PE-51737 Quality Assurance Entity Architectural Testing, Inc„ an Intertek Company Quality Assurance Contract Expiration Date 12/31/2023 Validated By Kurt Dietrich PE Validation Checklist - Iiardcopy Received Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code FL36650 R7 CM Cer, of Ind Seater s.ndf Standard Year ANSI/DASI.IA 10S 2017 ANSI/DASMIA 108 2012 ANSI/DASMA 115 2017 ANSI/DASMA 115 2012 TAS 201 1994 TAS 202 1994 TAS 203 1994 R2571, R2572, R2580, R2581, R2582 Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +24.61-27.6 Other: Glazing is an available option for all PAN Series products listed but it does not meet the Impact resistant requirement for windbomL debris regions. 16650.20 r ~^� ; 20..PAN C2021, C2015, C2410,� f R2410, C?, 411, C2415, C2460, ! R2460, C2461, R2461, C2471, ( R2471, C2472, R2472, C248D, R2480, C7..61, R2481, C2482, i, R2482, C2511, R2560, 112561, t R2571, R2572, R2580, R2581, f R2582 Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure:=313/-34.9" Other: Go to Page a Installation Instructions F1.16650 R7 H WL-2000-0194-08-25-281.-RevD s,p4 Verified By: John E. Scates 51737 Created by Independent Third Party: Yes Evaluation Reports Ft 16650 R7 AE EvalRQpt, pAh 5.p�f Created by independent Third Patty: Yes PAN Series sectional pan type garage door 162" wide Installation Instructions FL16650 R7 11 WL-2000-0194-31-35-RevH s_ndf Verified By: John E. Scates 51737 Created by Independent Third Party: Yes Evaluation Reports FL16650 R7 AF FvalRept I'd ; per j Created by Independent Third Party: Yes 0 0 Page1/20 0 Co"wt Us :::&^,1 DIZ!, Stana?c�, Te nebea�" rr_ J?3?P Phtiv: 8;n.dfi7.7F24 Tha State of Ftanda Is an hhJEBG catpiayef. � 5ht 2Lb7-202? SCR- e! FIr. �C-e.:c Fr<,acv It rE eMen! ; ; arrn;<<hlrry Sraramnn! ;; Pnure s!a!onec! Under Florid,, law, emali addrescrc arc p•Jb➢c recwts. if vcu donot rent yr it a-na:l add!ess released in'res:�onse to a public -records request, do nct send cicc!rar:c maJ W this cnoty. In;ir,.d,cnntaot the office by phone or by tradltic10 mall, if you .have eny questions, V;eare centaCt 650.457.1395, purstrant to Section 455.275(1), rlori<a 5tawiaf, affcGae Cctacer 1, 2oi2, I`tcrsees I:cermcd c-der charter 455, S. must arov<de the, oe;aflmer•., wi%h an ema'l address t: thay have aria. The ema:G Vavlded may beused for official communica;lon with tare Cl-tmee,: HdWtver email addiesse5 ale pub:=,?cord. Ir you do nr:, wish to sUPPlY a prrsonal adore «h, please provide the Department v.i:h an email adore.n whic.'r can be made ava74ble to the public. TO determ-no if you arc o IICC✓_SQe Qmef CtiApier 4$5, F,S., please crick here . Product Approval AeeeptS.- Safe Door 1 7'-0" See, below f door Door Width 16' - 2" Shown NOTE: Track configuration above the door opening does not affect the wind load rating of the door. �I UIWILICF144! III Top Bracket up door widths t" • I�N__N_N_�_N_N_ SlideLockorLockBars • Manual door locks are operator l u� c) Bottom Bracket ",— End Hinges Strut & Strut Attachment \— Intermediate Hinge Detail C (sheet 2 of 3) Detail 8 (sheet 2 of 3) Detail E (sheet 2 of 3) Detail D (sheet2 of 3) This product has been evaluated per ANSI/DASMA 108 for static air pressure. This product has been evaluated per ANSI/DASMA 115 for large missile impact and cyclic wind pressure Model Number PAN CZ460 &.R2460SERIES PAN C2410& R24105 PAN C2461 & R2461 SERIES PAN 024BO & R2480SERES PAN CZ471 & R2471 SERIES PAN C2481&R2481 SERIES PAN C2472&R2472 SERIES PAN-C2011 SERIES PANC202&R2482sERIEs PAN R2560 SERIES PAN C2015 SERIES PAN R2580 SERIES PAN R2561 SERIES PAN C2411 SERIES PAN R26B1 SERIES PAN R2571 SERIES PAN C2415 SERIES PANR2582 SERIES PAN R2572 SERIES PAN C2511 SERIES Door widths Up To Desi n Pressures +PSf I - psi End Stile Minimum Stiles Center I Hinqes Minimum Stiles Center Hinges Minimum Stiles Center I Hincies Impact Resistant 10'-T 49.7 -55.5 Single 4 2 3 -1 5 2 NO 12'-2" 41.5 -46.3 Single 5 2 5 2 5 2 NO 14'-2" 35.7 -39.8 Single 6 3 5 2 7 3 NO 16'-2" 31.3 -34.9 Single 7 3 7 3 7 3 YES 16'-2" 24.7 -27.6 Single 7 3 7 3 7 3 NO 20'-2' 20.1 -22A Single 9 5 9 5 11 5 NO 10'-2' 31.3 34.9 Single 4 2 3 1 5 2 YES 12'-2° 31.3 -34.9 Single 5 2 5 2 5 2 YES 14'-2° 1 31.3 34.9 Single 6 3 1 5 2 7 3 YES This product is designed and sold by PSF. The AHJ or Engineer of Record is responsible for determining the PSF required for any given site. 4" +/- 3„ -1 102" +/- 3" Jamb bracket quantities shown are for use with grode 2. or better southern pine jambs. Supporting structural elements are to be designed by a registered professional engineer for specific wind loads. Total # of Total # of Struts Jamb BddsSections r Side 4 4 5 4 4 5 M 4 4 6 4 4 6 4 4 6 5 5 7 T-9° 5 5 7 8'-0" 5 5 7 Maximum section height is 21 in. Maximum door height is 16 ft. All doors, even those above the tested height, areavailable with jamb brackets or commercial full angle. - The maximum spacing of the. jamb brackets/track clips should be maintained. NOTICE: These drawings are a supplement to the installation instructions for a standard door and only covers those procedures that vary from standard door installation. If these specific procedures ore not followed, the door may not perform as designed. IMPACT RESISTANT — Jamb Bracket Detail F (sheet 2 of 3) L .John E Scales, P.E. 2560 King Arthur Blvd. Ste 124-54 Lewisville, Texas 75056 Florida P.E. # 51.737 FL #16650.20 Professional Engineer seal provided only for verification of wind. load construction details. 1 2 3 4 5 6 7 1 8 END STILES PUSH NUT 7/16- 2�r END HINGE 1/4" SCREW 3/4" Hex Washer Head 16 Ca Galvanized Steel See DETAIL K for push nut 14 Go, Galvanized Steel Self Drilling (3 per Bottom Bracket) IFdi PUSH NUT placement. TEK SCREW BOTTOM BRACKETF7/16" 1/4"X 3/4" Hex Washer HeadSee 13 DETAIL K for push nut TEK SCREW o 4" Go Galvanized Steel Self Drilling (6 per Hinge)1 placement. 4" X 3 / / Hex Washer HeadSelf TOP FIXTURE Drilling (2 per Bracket) NOTE: This sarewshould beADJUSTABLE PUSH NUT 12 Ga o g O located below the prepurlahed hde 7/1fi" p LOW HEADROOM TOP and go through the hinge, end able See DETAIL K for push nut TEK SCREW BRACKET and skin edge placement. 1/4" X 3/4' Hex Washer Head Self Bracket) PUSH NUT BOTTOM SEAL Drilling (4 per DETAIL A LOW HEADROOM DETAIL B Sea DETAIL K for push nut DETAIL C E 'TOP placement. E BRACKET 24' 3 1/2" x 4" E STRUT INTERMEDIATE STILE 111 (3, 50 KSI Minimum 16 Go Galvanized Steel _ Galvanized Steel'T ° �V7 j JAMB BRACKET 12 Go Galvanized Steel o o opopo SLIDE LOCK or LOCK BARS INTERMEDIATE HINGE, 18 or 14 Go Galvanized Steel I`jr^gll�r� 1'r ° 32z r ° a (not required with operator) 0 0 l�J TEK SCREW TEK SCREW ` 1/4" X 3/4" Hex Washer BOLT & NUT D 1/4" X 3/4" Hex Washer Head TEK SCREW Head Self Drilling (4 per 1/4-20 X 5/8" Carriage Slide Lock) D Self Drilling (4 per Hinge) 1/4" X 3/4" Hex Washer Bolt & 1/4-20 Hex Washer DETAIL D DETAIL E Head Self Drilling (2 per DETAIL F Nut (I Per Jamb Bracket) DETAIL G End &. Intermediate. Stiles) WITH AND 00 11"OOT BRACE 00 00 0 0 0 0 0 0 0 o o o oap NOTE: Details on some views omitted for clarity. o. Double end stiles and end hardware may be �Q provided on wider or heavier doors. 0 C o 0 0 0 Da Maximum I I 3n FLAG BRACKET C 1/2" DETAIL K ROLLER RESIDENTIAL & LIGHT COMMERCIAL COMMERCIAL COMMERCIAL For Standard, High For Standard, High There should be a 2" Diameter Nominal BOLT 5/16 X 1 5/8" Log Bolt For Low Headroom & Vertical Lift & Vertical Lifte space of maximum Eleven' Ball Nylon or (4 per Flog Bracket). With 2" Track and With 2" Track and. With 3" Track end 1/2' between the roller Ten Boll Steel with BOLT &NUT Single End Stiles Single End Stiles Single End Stiles hub and the outside a Minimum Workable 1/4-20 x 5/8" Track Bolt edge of the roller Shaft Length Shown. holder which is set by &. 1/4-20 Hex Washer Nut B ° the push nut. (2 for Horizontal & 2 for DETAIL H Vertical Track) L B o ° Min, - DOOR' SKIN Min. John E Scales. P.E. of I' Minimal 25 Go Galvanized Pointed Steel -' of i" '2560 King Arthur Blvd. Ste 124-54 IMPACT RESISTANT ForidallP.E.e, Te# 5173756 FL #16650.20 Professional Engineer seal provided only for COMMERCIAL HEAVY DUTY COMMERCIAL HEAVY DUTY verification of wind load construction details. For Standard, High & For Low Headroom With Vertical Lift With 3" Track 3" Track and Double BOL<1.HrR 5/16' X 1 5/e" Lag Bolt & 2' O.D, VERTICAL TRACK - 2' Nominal 13 Ga Galvanized Steel tasted. DESCRIPTION: WOOD JAMB . _ 162"PAN 2000 SERIES WIND IDAD A and Double End Stiles End Stiles 7E, I.D. Fla! Washer NOTE: Jpmti bracket must be in 3' Nominal 13 Go rs also The vertical wood omb - SECTIONALDOOR J. fasteners may be counter sunk 4 Q F DESIaNPRE$SIIItE+7131-M.9 PSF A ALTERNATE BOTTOM BRACKETS direct °^=cat with the 2x6 (No approved Ps an altemole. su provide a Tldt mounting surface. Sec jamb attachment DFAtfIIN01�.: W1r2000.0194-4 REV. 11 NOTE: The bottom bracket tested (shown in T is the lightest bracket drywatl allowed). NOTE: The flat washer is not required details to sheet u for attaching ay ilr1. DRIIWM tT: MVS WiF DRII@RL• 4/17/14 REV. OArE 7/8/19 711 jambs to the structure. �'a"es. aaMA , available. for angle mount. me.alnanma EAOOEL(S): SceShcet3 SHEEF.20F3 1 2 3 4 5 6 7 1 8 MODEL NUMBERS MODEL NUMBERS AVAILABLE PAN C2011 SERIES PAN C20,15 SERIES PAN C2411 SERIES PAN C2415 SERIES PAN'C2511 SERIES PAN C2410 & R2410 SERIES PAN C2460 & R2460 SERIES .PAN C2461 & R2461 SERIES PAN C2471 & R247-1 SERIES PAN C2472 & R2472,SERIES PAN'C2480 & R2480 SERIES PAN C2481 & R2481 SERIES PAN.C2482 & R2482 SERIES PAN R2560 SERIES PAN R2561 SERIES PAN R2571 SERIES PAN R2572-SERIES PAN R2580 SERIES PAN R2581 SERIES PAN R2582 SERIES FASTENER TO CONTINUE PASTHEADER OPE HEI FIRST FASTENEF ABOVE THE F o HT HT G 2 X 6 GRADE 20R BETTER SOUTHERN PINEJAMBS. SEE CHART FOR WOOD JAMB ATTACHMENT TO BUILDING STRUCTURE. MAXIMUM ON CENTER SPACING 4"to 70" .00R OPENING WIDTH WOOD JAMB ATTACHMENT Building Mntrnwi Mnkn— Minh- Madm All—ble 81rucWre Fastener Type �ri,yeamem D. — osnper oSp v9 TLoW Min. 2500 PSI to Tapcon + (PLUS) 2' 2,50' 5.0D' 24' 551 4000PSIConcrete 1/4'w/1'DDwasher Southern Pine 3l8' Lag w/ 1 118' OD washer 7.50' 1.50' 1.50' 241 620 Spruce Pine Fir " OD Leg w/ 1 1. was her 1.50' 1.5D' 1.50' 2Y 482 NOTE: M mounted to the wall must be Southern Pine Grade 2 or better. IMPACT RESISTANT 7 L John E Staten, P.E. 2560 King Arthur Blvd. Ste 124-54 Lewisville, Texas 75056 Florida P.E. # 51737 FL#16650.20 Professional Engineer seal provided only for - verification .of wind load construction details.