HomeMy WebLinkAboutEvaluation Report0
ENGINEER .
, 0
eCopy
�`t'JCJCEIVED
CODE COMPUA ft 14 2022
ST. LUICIE 000N erndlnrZ*
Polyglass USA, Inc.
1111 West Newport Center Drive
Deerfield Beach, FL 33442
(954) 233-1330
Race
EVALUATE
NEMO I etc.
Certificate of Authorization #32455
353 Christian Street, Unit #13
Oxford, CT 06478
(203) 262-9245
TEST CONSULT
Evaluation Report P12060.02.09-R31
FL5259-1135 (NON-HVHZ)
Date of Issuance: 02/24/2009
Revision 30:12/20/2021
SCOPE:
This Evaluation Report is issued under Rule 611320-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for
use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described
herein have been evaluated for compliance with the 7" Edition (2020) Florida Building Code sections noted herein.
DESCRIPTION:, on ass Roof Underlayments ;for.use in FBC non.HVHZ jurisdictions "
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein and
FBC 1507.1.1. `
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality
Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change. Acceptance of our
Evaluation Reports by the named client constitutes agreement to notify MEMO ETC, LLC of any changes to the product(s), the
Qua lity Assurance or the production facility location s . NEMO ETC, LLC requires a complete review of its Evaluation Report relative
to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words "MEMO Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 17.
Prepared by:
,,,,��,.l�Onr�',ir/,
A.
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DCA ANE1983
'"�%w.SN�;;i;;: `' The facsimile seal appearing was authorized by Robert Nieminen, P.E. on
12/20/2D21. This does not serve as an electronically signed document.
CERTIFICATION OF INDEPENDENCE:
1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing
products it evaluates.
2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the
evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product.
S. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on
which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that
purpose.
02019 NEW ETC, LLC
OMEMO I etc.
ROOFING COMPONENT EVALUATION:
Product Category: Roofing
Sub -Category: Underlayment
Compliance Statement: Roof Underlayments,, as produced by Polyglass USA, Inc., have demonstrated compliance with the
following sections of the 711 Edition (2020) Florida Building Code through testing in accordance with the following Standards.
Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein.
Section
Pro a
Standard
Year
1504.3.1
Wind resistance
FM 4474
2011
1504.3.1
Wind resistance
UL 1897
2015
1507.1.1 /
R905.1.1
Material standard
ASTM D226
2009
1507.1.1, 1507.2.4, 1507.2.9.2 /
Material standard
ASTM D1970
2015
R905.1.1, R905.2.8.2
1507.3.3 /
R905.3.3
Material standard
FRSA/TRI, Sixth Edition
2018
1507.11.2
/ R905.11.2
Material standard
ASTM D6163
2015
1507.11.2
/ R905.11.2
Material standard
ASTM D6164
2011
1507.11.2
/ R905.11.2
Material standard
ASTM D6222
2011
1507.11.2
/ 11905:11.2
Material standard
ASTM D6509
2015
TAS 110
Accelerated Weathering
ASTM D4798
2011
Enti
Examination
Reference Date
Enti
Examination
Reference
Date
—ERD-(TST-6049)----A.STM-06509
P.37590.03.13-1-R1 02/DSA3
—NEMOA=-6049)—ASTM-DIWD
4j•P-LYG:205SUDL-05.A 09/30/20—
NEMO (TST 6049)
FRSA/TRI
4j-PLYG-20-SSUDL-OS.0
09/30/20
ERD (TST 6049) ASTM D6264 P37590.03.13-3A 03/06/13
ERD (TST 6049)
ASTM D6164
P37590.07.13-1 07/02/13
NEMO (TST 6049)
FRSA/TRI
4j-PLYG-20-SSUDL-11.A
10/22/20
ERD (TST 6049)
ASTM D4601
P45940.09.13 09/04/13
NEMO (TST 6D49)
ASTM D1970,D4798
4S-PLYG-18-004.12.19.D
10/27/20
ERD (TST 6049)
ASTM D1970 (adhesion)
P45370.09.13 09/18/13
NEMO (TST 6049)
FRSA/TRI
4j-PLYG-I9-SSUDL-01.A
11/18/20
(TST 6049)
ASTERD
TAS 114(C)(C) TAS 103,
TAS
P45270.05.14 05/12/14
NEMO (TST 6049)
ASTM D1623, TAS 103
4p-ICP-20-SSLAP-01.A
12/15/20
ERD (TST 6049)
ASTM D1623
P46520.10.14 10/03/14
NEMO (TST 6049)
ASTM D3623, TAS 103
4p-ICP-20-SSLAP-03.A-R1
03/04/21
ERD (TST 6049)
FRSA/TRI
P44360.10.14-R1 10/07/14
NEMO (TST 6049)
ASTM D4798, Di623
4j-PLYG-20-SSUDL-13.A
03/15/21
ERD (TST 6049)
ASTM D3970, D4798
P43290.10.14 10/17/14
NEMO (TST 6049)
ASTM D1623, TAS 103
4j-PLYG-20-SSUDL-07.A
10/29/21
ERD (TST 6049)
FRSA/TRI
PLYG-SC7550.03AS 03/24/15
NEMO (TST 6049)
ASTM D3623, TAS 103
41-PLYG-20-SSUDL-09.A
10/29/21
ERD (TST 6049)
ASTM D1623
P40390.04.15 04/03/15
NEMO (TST 6049)
ASTM D3970, D4798
4j-PLYG-2I-SSUDL-03.A
10/29/21
ERD-(TST 6049)
ASTM D1623, TAS 103
PLYG-SC10130.06.16-2 06/27/16
PRI (TST5878)
ASTM D1623, TAS 103
DAPF-062-01
03/08/18 '
ERD (TST 6049)
ASTM D1970, D4798
PLYG-SC30130.06.16-1 06/27/16
ERD (TST 6049)
Wind Uplift
11757.04.01-1-R1
04/25/01
ERD (TST 6049)
FRSA/TRI
PLYG-SC30130.06.16-3 06/27/26
ERD (TST 6049)
Wind Uplift
21757.08.01-1
08/13/01
ERD (TST 6049)
FRSA/TRI (tile slippage)
PLYG-SC13040.12.16 12/27/16
ERD (TST 6049)`
Wind Uplift
11776.06.02
03/16/03
ERD (TST 6049)
FRSA/TRI (tile slippage)
PLYG-SC32115.08.17 08/08/17
ERD (TST 6049)
Wind Uplift
P1740.01.07
01/04/07
ERD (TST 6049)
FRSA/TRI
PLYG-SC33035.08.17 10/31/17
ERD (TST 6049)
Wind Uplift
P1738.02.07-R2
02/05/07
NEMO (TST 6049)
ASTM D1970
4-PLYG-18-004.03.18 03/29/18
ERD (TST 6049)
Wind Uplift
P9260.03.08
03/21/08
NEMO (TST 6049)
ASTM D3623, TAS 103
4S-ICP-18-001.07.18-R1 07/23/18
ERD (TST 6049)
Wind Uplift
P30540.11.09-Rl
11/23/09
NEMO (TST 6049)
ASTM D6163
4S-PLYG-18-002.01.19-A 01/24/19
ERD (TST 6049)
TAS 117(B), TAS 114(C)
P13030.11.09-2
11/30/09
NEMO (TST 6049)
ASTM D6222
4S-PLYG-18-002.05.19-C 05/20/19
ERD (TST 6049)
TAS 114(J)
P39680.03.13
03/04/13
NEMO (TST 6049)
FRSA/TRI
4S-PLYG-18-004.10.19-G 10/08/19
ERD (TST 6049)
Wind Uplift
P41630.08.13
08/06/13
NEMO (TST 6049)
FRSA/TRI
4S-PLYG-18-004.30.19-1 10/08/19
ERD (TST 6049)
Wind Uplift
P11751.05.03-R3 —
11/26/13
NEMO (TST 6049)
FRSA/TRI
4S-PLYG-18-004.10.19-L 10/09/19
ERD (TST 6049)
Wind Uplift
P11781.11.03-R1
11/26/13
NEMO (TST 6049)
FRSA/TRI
4S-PLYG-18-004.12.19-F 12/18/19
ERD (TST 6049)
Wind Uplift
PLYG-SC8905.05.16-1
05/17/16
NEMO (TST 6049)
FRSA/TRI
4j-PLYG-I9-SSUDL-02.A 01/02/20
ERD (TST 6049)
UL1897
PLYG-SC12025.30.16
10/12/16
NEMO (TST 6049)
ASTM D6222
4S-PLYG-18-002.12.19-K-Rl 01/07/20
FM (TST 1867)
Wind Uplift
FM 3004091
01/12/00
NEMO (TST 6049)
ASTM D3970, D4798
4S-PLYG-18-004.01.20.H 01/14/20
NEMO (TST 6049)
Wind Uplift
4L-PLYG-18-003.01.19
01/11/19
NEMO (TST 6049)
ASTM D3970, D4798
4S-PLYG-18-004.01.20.K 01/14/20
Polyglass USA
P/L Affidavit
Mule -Hide Cross Ltg
03/01/08
NEMO (TST 6049)
ASTM D6164
4S-PLYG-18-004.01.20.B 01/15/20
Polyglass USA
Materials Affidavit
Polystick Compound
08/18/11
NEMO (TST 6049)
FRSA/TRI (tile slippage)
4S-PLYG-18-004.01.20.A 01/16/20
Polyglass USA
Materials Affidavit
Polystick Compound
01/13/21
NEMO ETC, U.C.
Evaluation Report P12060.02.09-R31
Certificate of Authorization N32455
7TH EDITION (2020) FBC NON-HVHZ
EVALUATION
FL5259-R35 (NON-HVHZ)
Polyglass Roof Underlayments
Revision 31:12/20/2021
Page 2 of 17
Emitt
Examination
Reference
Date
NEW (TST 6049)
ASTM D1623,TAS 103
Alp-DOW-I9-SSLAP-01.A-R2
02/10/20
NEMO (TST 6049)
FRSA/TRI
PLYG-SC15855.05.20.A
05/29/20
NEMO (TST 6049)
FRSA/TRI
4j-PLYG-20-SSUDL-01
07/06/20
NEMO (TST 6049)
ASTM D6222
4q-PLYG-I9-SSMBB-0S.A
07/23/20
NEMO (TST 6049)
ASTM D4798, D1623
4j-PLYG-I9-SSUDL-0S.A
09/10/20
4.1
4.2
4.3
4.4
4.5
4.6
4.7
4.8
4.9
4.10
4.11
4.12
4.13
4.14
4.15
ONEMO I etc
gafiilt
Examination
Reference
Date
FRI(TST5878)
UL1897
708T0058-1
01/13/21
PRI(TSTS878)
UL1897
708T0058-6
02/17/21
PRI(TSTS878)
UL1897
70ST0058-7
02/25/21
UL(QUA9625)
Quality Control
Service Confirmation(FL)
09/13/18
UL (QUA9625)
Quality Control
Service Confirmation (TX)
12/07/19
UL (QUA9625)
Quality Control
Florida BCIS
Current
Product
Material Standard
Plant(s)
Description
Elastobase V (formerly
ASTM D6163
FL
Fiberglass -reinforced, SBS modified bitumen base sheet
"Elastobase")
Elastobase P
ASTM D6164
FL
Polyester -reinforced, SBS modified bitumen base sheet
Elastoflex S6 G
ASTM D6164
FL, PA
Polyester -reinforced, SBS modified bitumen cap sheet
FRSA/TRI 09-18
Elastoflex S6 G FR
ASTM D6164
FL
Polyester -reinforced, SBS modified bitumen cap sheet
FRSA/TRI 09-18
HydraGuard Dual Pro
ASTM D1970
FL
Nominal 60-mil thick dual -layer rubberized asphalt
waterproofing membrane, fiberglass reinforced, with a
polyester fabric surface
HydraGuard Tile Pro
ASTM D1970
FL
Nominal 60-mil thick dual -layer rubberized asphalt
FRSA/TRI 09-18
waterproofing membrane, fiberglass reinforced, with a
polyester fabric surface
Mule -Hide SA-APP Cap Sheet
ASTM D6222
FL
Polyester -reinforced, APP modified bitumen cap sheet
FRSA/TR109-18
Mule -Hide SA-APP Cap Sheet
ASTM D6222
FL
Polyester -reinforced, APP modified bitumen cap sheet
(FR)
FRSA/TR109-18
Polyflex G
ASTM D6222
FL
Polyester -reinforced, APP modified bitumen cap sheet for
FRSA/TRl 09-18
use as an alternate to Heat Applied "Cap Sheet" in the
"Two Ply System" from FRSA/TRI Florida High Wind
Concrete and Clay Roof Tile Installation Manual, Sixth
Edition beneath mechanically fastened or adhered tile
roof systems
Polyflex G FR
ASTM D6222
FL
Polyester -reinforced, APP modified bitumen cap sheet for
FRSA/TRI'09-18
use as an alternate to Heat -Applied "Cap Sheet" in the
"Two Ply System" from FRSA/TRI Florida High Wind
Concrete and Clay Roof Tile Installation Manual, Sixth
Edition beneath mechanically fastened tile roof systems
Polyflex SA P
ASTM D6222
FL, TX
Polyester -reinforced, APP modified bitumen cap sheet
FRSA/TRI 09-18
Polyflex SA P FR
ASTM D6222
FL, TX
Polyester -reinforced, APP modified bitumen cap sheet
FRSA/TR109-18
Polybase V (formerly "Polyglass
ASTM D6509
FL
Fiberglass -reinforced, APP modified bitumen base sheet
Base")
Polyglass G2 Base Sheet
ASTM D4601
AL
Fiberglass -reinforced, asphaltic base sheet
Polystick IR-Xe
ASTM D1970
FL, PA, TX
Nominal 60-mil thick rubberized asphalt waterproofing
membrane, glass fiber reinforced, with an aggregate
surface
NEMO ETC, I.I.C.
Certificate of Authorization N32455
7- EDITION (2020) FBC NON-HVHZ EVALUATION
Polyglass Roof Underlayments
Evaluation Report P12060.02.09-R31
FL5259-R35 (NON-HVHZ)
Revision 31:12/20/2021
Page 3 of 17
WE
4.16
4.17
4.18
4.19
4.20
ONEMOletc.
Product
Material Standard
Plant(s)
Description
Polystick MTS Plus
ASTM D1970
FL, NV,
Nominal 60-mil thick rubberized asphalt waterproofing
FRSA/TRI 09-18
PA, TX
membrane, glass fiber reinforced, surfaced with
polyolefinic film surface
Polystick TU Max
ASTM D1970
FL, PA, TX
Nominal 60-mil thick rubberized asphalt waterproofing
FRSA/TRI 09-18
membrane with a 190 g/m2polyester fabric surface
Polystick TU P
FRSA/TRI 09-18
FL, PA, TX
Nominal 130-mil thick rubberized asphalt waterproofing
membrane, glass-fiber/polyester reinforced, with a
granular surface
Polystick TU Plus
ASTM D1970
FL, PA, TX
Nominal 80-mil thick rubberized asphalt waterproofing
FRSA/TRI 09-18
membrane, glass fiber reinforced, with a polyester fabric
surface
Polystick XFR
ASTM D1970
NV, TX
Nominal 80-mil thick rubberized asphalt waterproofing
FRSA/TRI 09-18
membrane, glass fiber reinforced, surfaced with a
textured film surface
5.1 This is a Building Code Evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for
any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless
retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions i.e. Broward a-d—Wami-Dade Countiesa..
5.3 This Evaluation Report pertains to above -deck roof components. Roof decks and structural members shall be in accordance with
FBC requirements to the satisfaction of the Authority Having Jurisdiction.
5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and limitations
regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations concerning the use of foam plastic
insulation.
5.5 Polyglass Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within
FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this
evaluation combined with supporting data for the prepared roof covering.
NEMO ETC, I.I.C. Evaluation Report P12060.02.09-1131
Certificate of Authorization #32455 7- EDITION (2020) FBC NON-HVHZ EVALUATION FL5259-R35 (NON-HVHZ)
Polyglass Roof Underlayments Revision 31:12/20/2021
Page 4 of 17
ONEMOjetc.
5.6 Allowable Roof Covers:
TABLE 1: ROOF COVER OPTIONS
FBC Section:
1507.2
1507.3
1507.4 and 1507.5
1507.7
1507.8 and 1507.9
Asphalt
Clay and Concrete Tile
Slate or Slate-
Underlayment
Metal
Wood
Mechanical Attach
Adhesive -Set
Shingles
Type Shingles
Yes
Yes
Yes
Yes
Yes
Yes
Elastobase V
(Altemate to
(as Base Sheet,
(as Base Sheet,
(Alternate to
(Alternate to
(Altemate to
D226, Type II)
See 5.8.3)
See 5.8.3)
D226, Type 11)
D226, Type II)
D226, Type 11)
Yes
Yes
Yes
Yes
Yes
Yes
Elastobase P
(Altemate to
(as Base Sheet,
(as Base Sheet,
(Altemate to
(Alternate to
(Altemate to
D226, Type II)
See 5.8.3)
See 5.8.3)
D226, Type II)
D226, Type 11)
D226, Type 11)
Yes
Yes
Polybase V
No
(as Base Sheet,
(as Base Sheet,
No
No
No
See 5.8.3)
See 5.8.3)
Yes
Yes
Polyglass G2 Base
No
(as Base Sheet,
(as Base Sheet,
No
No
No
See 5.8.3)
See 5.8.3)
Elastoflex S6 G
No
Yes
Yes
No
No
No
(See 5.6.1)
Elastoflex S6 G FR
No
Yes
No
No
No
No
Yes
HydraGuard Dual Pro
Yes
No
No
Yes
Yes
(Jointstrips, 1507.1.1.3
/ 11905.1.1.3)
Yes
Yes
HydraGuard Tile Pro
Yes
Yes
(See 5.6.1)
Yes
Yes
(Jointstrips, 1S07.1.1.3
/ R905.1.1.3)
Mule -Hide SA-APP Cap Sheet
No
Yes
Yes
No
No
No
(See 5.6.1)
Mule -Hide SA-APP Cap Sheet (FR)
No
Yes
Yes
No
No
No
(See 5.6.1)
Polyflex G
No
Yes
Yes
No
No
No
(See 5.6.1)
Polyflex G FR
No
Yes
No
No
No
No
Polyflex SA P
No
Yes
Yes
No
No
No
(See S.6.1)
Polyflex SA P FR
No
Yes
Yes
No
No
No
(see 5.6.1)
Yes
Polystick IR-Xe
Yes
No
No
No
Yes
(jointstrips, 1507.1.1.3
/ R905.1.1.3)
Yes
Polystick MTS Plus
Yes
Yes
No
Yes
Yes
(Joint strips,1507.2.1.3
/ R905.1.1.3)
Yes
Yes
Polystick TU Max
No
Yes
(See 5.6.1)
Yes
No
(joint strips,1507.1.1.3
/ R905.1.1.3)
Yes
Yes
Polystick TU P
No
Yes
(See 5 6.1)
No
No
(joint strips,1507.2.1.3
/ R905.1.1.3)
Yes
Yes
Polystick TU Plus
Yes
Yes
(See 5.6.1)
Yes
Yes
(joint strips,1507.1.1.3
/ R905.1.1.3)
Yes
Polystick XFR
Yes
Yes
No
Yes
Yes
(joint strips,1S07.1.1.3
/ R905.1.1.3)
NEMO ETC, I.I.C. Evaluation Report P12060.02.09-1131
Certificate of Authorization #32455 7- EDITION (2020) FBC NON-HVHZ EVALUATION F1.5259-1135 (NON-HVHZ)
Polyglass Roof Underlayments Revision 31:12/20/2021
Page 5 of 17
NNEMOjetc.
5.6.1 Adhesive -set tile is limited to use of the following underlayment / tile -adhesive combinations.
TABLE 1A: ALLOWABLE UNDERLAYMENT / TILE -ADHESIVE COMBINATIONS'
Underlayment
DAP
Foam
Dupont
ICP Adhesives
StormBond
StormBond 2
Tile Bond
Polyset AH-160
Polyset RTA-1
FL14506
FL14506
FL22525
FL6332
FL6276
Elastoflex S6 G
No
No
No
Yes
Yes
Polyflex G
No
No
No
No
Yes
Polyflex SA P, Mule -Hide SA-APP Cap Sheet
No
No
No
Yes
Yes
Polyflex SA P FR, Mule -Hide SA-APP Cap Sheet (FR)
No
No
No
No
Yes
Polystick TU Max
No
Yes
Yes
CS?Yes
Polystick TU P
Yes
Yes
No
Yes
Yes
Polystick TU Plus, HydraGuard Tile Pro
No
Yes
Yes
Yes
Yes
5.7 Allowable Substrates:
TABLE 2: SUBSTRATE OPTIONS FOR`ADHERED UNDERLAYMENTS
Substrates (designed
to meet wind loads for project)
Underlayment
Application
Type
Primer
Matenal(s)
HydraGuard Dual Pro,
Deck /
(Optional) ASTM
plywood, OSB, Southe�n.Yellow Pine or Huber Engineered
"ZIP
HydraGuard Tile Pro, Polystick IR-
sheathing
D41
Woods System" Panels
ASTM D41
structural concrete
Xe, Polystick MTS Plus, Polystick
(OptioASTM
C1289 Type II Class 1 polyisocyanurate, ASTM
TU Max, Polystick TU P. Polystick
self-
T-U-P-lus,-P-olystick-XFR,-Mule-Hide--adhering--Insulation—
-C-1289Type-V-polyisocyanurate=composite-DensDec
SA-APP Cap Sheet, Mule -Hide SA-
D410 WB-3 00
D41 or WB-3000
Prime or SECUROCK Gypsum -Fiber Roof Board
APP Cap Sheet (FR), Polyflex SA P
ASTM D226, Type II felt; Elastobase V, Elastobase P or
or Polyflex SA P FR
Base Sheet
N/A
Mule -Hide Nail Base
Deck
ASTM D41
structural concrete
Elastoflex S6 G or Elastoflex S6 G
hot asphalt
Insulation
(Optional) ASTM
D41
DensDeck Prime or SECUROCK Gypsum -Fiber Roof Board
FR
Base Sheet
N/A
ASTM D226, Type II felt, Elastobase V, Elastobase P, Mule -
Hide Nail Base or Polyglass G2 Base
Deck
ASTM D41
structural concrete
Polyflex G or Polyflex G FR
torch-
Insulation
(Optional) ASTMDensDeck
D41
Prime or SECUROCK Gypsum -Fiber Roof Board
applied
Base'Sheet
a
N/A
Elastobase V, Elastobase P, Mule -Hide Nail Base, Polyglass
G2 Base or Polybase V
1 Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance.
NEMO ETC, I.I.C. Evaluation Report P12060.02.09-R31
Certificate of Authorization #32455 7- EDITION (2020) FBC NON-HVHZ EVALUATION FL5259-1135 (NON-HVHZ)
Polyglass Roof Underlayments Revision 31:12/20/2021
Page 6 of 17
ONEMOletc.
5.8 Attachment Limitations:
5.8.1 For use under mechanically attached NON -TILE prepared roof coverings, attachment shall be in accordance with the
manufacturer's installation instructions, but - for mechanically attached underlayments or base sheets - not less than FBC
1507.1.1 or R905.1.1.
5.8.2 For use under the roof systems, attachment shall be in accordance with the manufacturer's installation instructions, but -
for mechanically attached base sheets - not less than:
• FRSA/TRI Florida High Wind Concrete and Clay Roof rile Installation Manual, Sixth Edition, Appendix A, Table 1(for Two -
Ply Asphalt Applied Hot Mop Underlayment)
or
• Section 5.8.3 herein (for other underlayment systems).
5.8.3 Wind Resistance for Underlayment Systems in Tile Roof Applications:
The following wind uplift limitations apply to underlayment systems that are not prescriptive in the FRSA/TRI Florida High
Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition. The Maximum Design Pressure is the result of testing
for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1
margin of safety per FBC 1504.9 has already been applied).
�r-.83.1 Direct -to -Deck:
The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI Florida High
Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A, Table 1A or the critical (highest) design
pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3.
#1 Maximum Design Pressure = -52.5 psf:
Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Joints: Min. 4-inch wide strips 5f ElastoflexSA-Vover a 10 Iom�l -lets
Base Ply: Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#2 Maximum Design Pressure = -90 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: None
Base Ply: (Optional) Polystick.MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered.
#3 Maximum Design Pressure = -97.5 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: PG100 or ASTM D41
Base Ply: (Optional)' Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x 1'/a" ring shank
nails through 32 ga.,1-5/8" diameter tin caps spaced 12-inch o.c.
\11—#4 Maximum Design Pressure = -105 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: WB-3000
Base Ply: (Optional) Polystick MTS Plus, self -adhered.
Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick
TU P or Polystick TU Plus, self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x 1'/0" ring shank
nails through 32 ga.,1-5/8" diameter tin caps spaced 12-inch o.c.
NEMO ETC, I.I.C. Evaluation Report P12060.02.09-1131
Certificate of Authorization #32455 7- EDITION (2020) FBC NON-HVHZ EVALUATION FL5259-R35 (NON-HVHZ)
Polyglass Roof Underlayments Revision 31:12/20/2021
Page 7 of 17
V
ONEMO.Jetc.
#53 Maximum Design Pressure = -127.5 psf:
Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Base Sheet: Elastobase V or Polybase V
Fasteners: TRUFAST Versa -Fast Fasteners & Plates with one (1) screw per plate, in the center hole.
Spacing: 9-inch o.c. at the 4-inch wide side laps and 9-inch o.c. at four (4) equally spaced staggered center rows.
Underlayment: Polyflex G, torch -applied.
5.9 Exposure Limitations:
TABLE 3: EXPOSURE LIMITATIONS
Underlayment
Prepared Roof Cover
Installation Type
Maximum
Exposure (days)
Elastobase V, Elastobase P, Polyglass G2 Base or Polybase V
Mechanically attached
30
Polystick IR-Xe
Mechanically attached
90
HydraGuard Dual Pro, HydraGuard Tile Pro, Polystick MTS Plus, Polystick TU Max, Polystick
TU P, Polystick TU Plus or Polystick XFR
Any type (per Table 1)
180
Elastoflex S6 G, Elastoflex S6 G FR, Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap
Sheet (FR), Polyflex G, Polyflex G FR, Polyflex SA P or Polyflex SA P FR
Adhesive -set the roof system
180
Mechanically attached
UNLIMITED
5.10 Tile Slippage Limitations: When loading roof tiles on the underlayment in direct -deck tile roof assemblies, the maximum roof
slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles.
TABLE 4: TILE SLIPPAGE LIMITATIONS.FOR DIRECT -DECK TILE INSTALLATIONS
Underlayment
Tile -Profile
Sfaging-Methoti
—MaximtTm-StagitfgSiope
Elastoflex S6 G or S6 G FR
Flat or Lugged
6-tile stack (4 over 2)
Prohibited without battens
HydraGuard Tile Pro
Flat or Lugged
6-tile stack (4 over 2)
7:12
Polyflex G or G FR
Flat or Lugged
6-tile stack (4 over 2)
4:12
Polyflex SA P or SA P FR
Flat or Lugged
6-tile stack (4 over 2)
4:12
Polystick MTS Plus
Flat.
6-tile stack (4 over 2)
5:12
Lugged
6-tile stack (4 over 2)
4:12
Polystick TU Max
Flat
6-tile stack (4 over 2) or 10-tile stack
7:12
Lugged
6-tile stack (4 over 2)
7:12
Lugged
10-tile stack
6:12
Polystick TU P
Flat or Lugged
6-tile stack (4 over 2)
7:12
Polystick TU Plus
Flat or Lugged
6-tile stack (4 over 2)
7:12
Flat or Lugged
10-tile stack
6:12
Polystick XFR
Flat or Lugged
Prohibited without battens
Prohibited without battens
NEMO ETC, I.I.C.
Certificate of Authorization #32455
7- EDITION (2020) FBC NON-HVHZ EVALUATION
Polyglass Roof Underlayments
Evaluation Report P32060.02.09-R31
FL52S9-R35 (NON-HVHZ)
Revision 31:12/20/2021
Page 15 of 17
ONEM01-etc.
n'"7. r `� 3 au+�•..y. `: :P"*7W`1r+^S'�}a 'x.r7➢•` i '@K- +^ ca t rv.,. ♦ aft �.
+S F`� :§^3 Y• � .�h "� 4 c( +r�'1��'.. ��5�',""� x. '+°`�cp 'a `y'� 'fT �? ha'"' 'C!�: "s +'�."c? zvr r ,.f
6 ,s.
Limitations6.1 Polyglass; Roof Underlayments shall be installed in accordance with Polyglass published installation instructions subject to the
•rth in Section 5 herein and the specificsnoted
6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust
and debris prior to application, and prime the substrate (if applicable).
6.3 -Elastobase V, Elastobase P or Mule -Hide Nail Base:
6.3.1 Non -Tile ADDlications:
Shall be installed in compliance with requirements for an approved mechanically attached underlayment (ASTM D226, Type
II) in FBC Table 1507.1.1.1 or FBC Residential Table R905.1.1.1 for the type of prepared roof covering to be installed, and the
manufacturer's installation instructions. FBC requirements take precedence over the manufacturer's installation instructions.
Elastobase V. Elastobase P or Mule -Hide Nail Base may be covered with a layer of Polystick IR-Xe, Polystick MTS Plus, Polystick
TU Max, Polystick TU, P, Polystick TU Plus, Polystick XFR, Polyflex SAP, Polyflex SA P FR, Mule -Hide SA-APP Cap Sheet or SA-APP
Cap Sheet (FR), self -adhered, Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt or Polyflex G or Polyflex G FR. torch applied.
Roof cover limitations are those are those associated with the top -layer underlayment, as set forth in Table 1.
6.3.2 Tile Applications:
6.3.2.1 Elastobase V (poly -film top), Elastobase P (poly -film top) and Mule -Hide Nail Base are limited to use as a mechanically attached
base sheet in the "TWO-PLY SYSTEM" from FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth
Edition, followed by Polystick MTS Plus, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick XFR, Polyflex SAP, Polyflex
SA P FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR), self -adhered or Polyflex G or Polyflex G FR, torch -applied. Tile
roof installation method is limited by the selected Cap Sheet, as set forth in Table 1. Refer to Section 5.8.3.2 herein for
attachment requirements.
6.12.2—Elastobase_V_(sanded_top.)-and-Elastobase-P_(sanded-top.)e-are-limited-to-use-as-a-mechanically-attached-base sheet in -the
"TWO-PLY SYSTEM" from FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, followed
by Elastoflex S6 G, Elastoflex S6 G FR or an FBC Approved Mineral Surfaced Cap Sheet (ASTM D6380), asphalt -applied or
Polyflex G or Polyflex G FR, torch -applied. Tile roof installation method is limited by the selected Cap Sheet, as set forth in
Table 1.
• When Elastobase V (sanded -top) or Elastobase P (sanded -top) is followed by asphalt -applied Elastoflex S6'G, Elastoflex
S6 G FR or FBC Approved Mineral Surfaced Cap Sheet (ASTM D6380), refer to FRSA/TRI, Sixth Edition, Appendix A, Table
1 or Section 5.8.3.2 herein for attachment requirements.
• When Elastobase V (sanded -top) or Elastobase P (sanded -top) is followed by torch -applied Polyflex G or Polyflex G FR,
refer to Section 5.8.3.2 herein for attachment requirements.
6.4
6.4.1
6.4.2
HydraGuard Dual Pro, HydraGuard Tile Pro, Mule -Hide SA-APP Cap Sheet, IMule=H)de SA-APP.Cap Sheet (FR), Polyflex SA P,
Polyflex SSA P FR, Polystick IR-Xe, Polystick MTS Plus, Polystick TU Max, Polystick TU`P, Polystick TU Plus or Polystick XFR:
General:
All seal -lap seams (selvage laps) must be firmly rolled with a
in accordance with Polyglass requirements to ensure full
contact and adhesion. For HydraGuard Dual Pro and
HydraGuard Tile Pro, align the edge of the top sheet to the
end of the glue pattern (the sheet will overlap the fabric).
Non -Tile ADDlications:
View of Overlap Seam of HydraGuard Dual Pro and HydraGuard Tile Pro
NEMO ETC, I.I.C. Evaluation Report P12060.02.09-1131
Certificate of Authorization #32455 7- EDITION (2020) FBC NON-HVHZ EVALUATION FL5259-1135 (NON-HVHZ)
Polyglass Roof Underlayments Revision 31:12/20/2021
Page 16 of 17
OMEMO I etc.
Shall be installed in compliance with requirements for an approved self -adhering underlayment (ASTM D1970) in FBC
1507.1.1.1 or 1507.1.1.3 or FBC Residential R905.1.1.1 or R905.1.1.3 for the type of prepared roof covering to be installed,
and the manufacturer's installation instructions.
When installed over a mechanically attached base sheet of FBC Approved ASTM D226, Type II felt, Elastobase V, Elastobase P
or Mule -Hide Nail Base, the base sheet shall be fastened in accordance with FBC 1507.1.1 or R905.1.1.
6.4.3 Tile Applications (excludes HydraGuard Dual Pro and Polystick IR Xe):
Shall be installed in compliance with the requirements for Self -Adhered Membrane set forth in FRSA/TRI Florida High Wind
Concrete and Clay Roof Tile Installation Manual, Sixth Edition and the manufacturer's installation instructions.
Refer to Section 5.8.3 herein for attachment limitations.
Refer to Table 4 herein for tile staging limitations.
6.4.4 Multi -Ply Underlayment Systems:
Polystick MTS Plus or Polystick XFR followed by HydraGuard Tile Pro, Polyflex SA P, Polystick MTS Plus, Polystick TU Max,
Polystick TU P, Polystick TU Plus or Polystick XFR is allowable for use under mechanically attached prepared roof systems.
Limits of use are those associated with the top -layer material. This is not a requirement, but is allowable if a 2-ply
underlayment system is desired.
Polystick MTS Plus followed by HydraGuard Tile Pro, Polyflex SA P, Polystick TU Max, Polystick TU P or Polystick TU Plus is
allowable for use under adhesive -set tile systems. Limits of use are those associated with the top -layer material. This is not a
requirement, but is allowable if a 2-ply underlayment system is desired.
6.5 Elastoflex S6.G or Elastoflex S6 G FR:
6.5.1 Shall be installed in compliance with requirements as an alternate to the "Hot Asphalt Applied Cap Sheet" in the 'Two Ply
System" in the FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, and the
manufacturer's installation instructions.
Refer to Section 5.8.2 and 5.8.3 herein for attachment limitations.
Refer to Table 4 herein for tile staging limitations.
6.6 Polyflex G or Polyflex G FR:.
6.6.1 Shall be installed in compliance with requirements as an alternate to the "Heat Applied Cap Sheet" in the "Two Ply System" in
the FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, and the manufacturer's
installation instructions.
Refer to Section 5.8.3 herein for attachment limitations.
Refer to Table 4 herein for tile staging limitations.
As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this product.
Contact the named QA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 QA requirements. Refer to Section
4 herein for products and production locations having met codified material standards.
UL LLC—QUA9625; (360) 817-5512; Vinycia.Seman@ul.com
- END OF EVALUATION REPORT -
NEMO ETC, I.I.C. Evaluation Report P12060.02.09-1131
Certiykate of Authorization #32455 7- EDITION (2020) FBC NON-HVHZ EVALUATION FL5259-R35 (NON-HVHZ)
Polyglass Roof Underlayments Revision 32:12/20/2021
Page 17 of 17