HomeMy WebLinkAboutNOANT1Y '. File COPY DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (NO MIAMI-DADS COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 RECEIVED Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 B 14 2022w waniamidade.tov/economy Boral Roofing, LLC, Lucie County ®®�®��fA���. 7575 Irvine Center Drive, Suite 100 &E Permitting Irvine, CA 92618 ST. L CIE COUNTY SCOPE: 8 0 C C 9/1 OZ This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Boral Villa 900 Concrete Roof Tile LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews and revises NOA# 21-0420.02 and consists of pages 1 through 7. The submitted documentation was reviewed by Alex Tigera. NOA No.: 21-0712.03 MIAMI•DAD, COUNTY Expiration Date: 09/21/26 Approval Date: 09/16/21 Page 1 of 7 ROOFING ASSEMBLY APPROVAL Category: Roofing Sub Category: Roofing Tiles Material: Concrete 1. SCOPE This renews a system using Boral Villa 900 Concrete Roof Tile, as manufactured Boral Roofing, LLC in Lake Wales, FL and described in Section 2 of this Notice of Acceptance. For locations where the pressure requirements, as determined by applicable Building Code, do not exceed the design pressure values obtained by calculations in compliance with RAS 127 using the values listed in section 4 herein. The attachment calculations shall be done as a moment based system. 2. PRODUCT DESCRIPTION Manufactured by Test Product Applicant Dimensions Specifications Description Boral Roofing Villa 900 Length =17" TAS 112 Low profile, interlocking, high pressure extruded Width =13" Type lb concrete roof tile equipped with three nail holes ''Y? thick Class III and double rolls. For direct deck, batten, mortar or adhesive set applications. Trim Pieces 1= varies TAS 112 Accessory trim, concrete roof pieces for use at w = varies ridges, hips and rakes. varying thickness 2.1 PRODUCTS MANUFACTURED BY OTHERS Product Name Product Description Manufacturer (With Current NOA) ICP Adhesives Polysee AH-160 Two component polyurethane ICP Adhesives and Sealants, Inc. foam adhesive. . TILE BOND Roof Tile Adhesive Single component polyurethane DuPont de Nemours, Inc. foam roof tile adhesive. "Tile Tite" Roof Tile Mortar Premixed, pre -bagged roof tile Bermuda Roof Co. Inc. mortar. Touch `N Seal StormBone 2 Two- Two component polyurethane DAP Foam, Inc. Component Polyurethane Roof Tile foam adhesive. Adhesive Touch `N Seal StormBone One One component polyurethane DAP Foam, Inc. Component Polyurethane Roof Tile foam adhesive. Adhesive 2.2 MANUFACTURING LOCATION 2.2.1. Lake Wales, FL NOA No.: 21-0712.03 Expiration Date: 09/21/26 Approval Date: 09/16/21 Page 2 of 7 2.3 EVIDENCE SUBMITTED Test Agency Nutting Engineers Redland Technologies The Center for Applied Engineering, Inc. Redland Technologies Test Identifier Test Name/Report Date 13343.1 TAS 112 Apr. 2006 7161-03 Static Uplift Testing Dec. 1991 Appendix III TAS 102�& TAS 102(A) 7161-03 Wind Tunnel Testing Dec. 1991 Appendix II TAS 108 (Nail -On) P0402 Withdrawal Resistance Testing of Sept. 1993 screw vs. smooth shank nails 94-060B Static Uplift Testing March, 1994 TAS 101 (Adhesive Set) 94-084 Static Uplift Testing May 1994 TAS 101 (Mortar Set) P0631-01 Wind Tunnel Testing July 1994 TAS 108 (Mortar Set) Letter Dated Aug. 1, 1994 Wind Tunnel Testing Aug. 1994 TAS 108 (Nail -On) The Center for Applied Project No. 307025 Wind Driven Rain Oct. 1994 Engineering, Inc. Test #MDC-76 TAS 100 25-7183-1 Static Uplift Testing Feb. 1995 25-7183-2 TAS 1 Q2 (2 Quik-Drive Screws, Direct Deck) 25-7214-2 Static Uplift Testing March, 1995 25-7214-6 TAS 102 (1 Quik-Drive Screw, Direct Deck) (1 Quik-Drive Screw, Battens) Celotex Corporation 528454-2-1 Static Uplift Testing Sep. 1998 Testing Services 520109-2 TAS 101 Dec. 1998 Walker Engineering, Inc. Evaluation Calculations 254183 March 1995 Evaluation Calculations 25-7094 February 1996 Evaluation Calculations 25-7496 April 1996 Evaluation Calculations 25-7584 December 1996 25-7804b-8 25-7804-4 & 5 25-7848-6 Evaluation Calculations Aerodynamic Multipliers 09/01/16 Evaluation Calculations Two Patty Adhesive Set System April 1999 Evaluation Calculations Restoring Moment Due to Gravity 09/01/16 American Test Lab of South RT0617.02-16 TAS 112 06/29/16 Florida RT0503.02-21 TAS 112 05/12/21 NOA No.: 21-0712.03 Expiration Date: 09/21/26 Approval Date: 09/16/21 Page 3 of 7 PRI Construction Materials COPO-002-02-11 Static Uplift Testing 10/12/2016 Technologies TAS 101 (Adhesive Set) COPO-002-02-04 Static Uplift Testing 10/12/2016 TAS 101 (Adhesive Set) COPO-002-02-03 Static Uplift Testing 10/12/2016 TAS 101 (Adhesive Set) 2002T003.02 TAS 101 11/06/20 NEMO ETC, LLC 4c-DPBS-20-LSOTM-0l.C.R1 TAS 101 12/17/20 3. LIMITATIONS: 3.1 Fire classification is not part of this acceptance. 3.2 For mortar or adhesive set tile applications, a static field uplift test shall be performed in accordance with TAS 106. 3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test in accordance with TAS 112, appendix `A'. Such testing shall be submitted to the Building Code Compliance Office for review. 3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed section 4.1 herein. 3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers published literature. 3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with applicable building code. 4. INSTALLATION 4.1 Villa 900 Concrete Roof Tile and its components shall be installed in strict compliance with Roofing Application Standard RAS 118, RAS 119, and RAS 120. 4.2 Data For Attachment Calculations Table 1: Average Weight (W) and Dimensions (I x w ) Tile Profile Weight W (Ibf) Length -I (ft) Width-w (ft) Villa 900 Concrete Tile 10.90 1.42 1.08 Table 2: Aerodynamic Multipliers - I (ft3) Tile Profile 2L (ft3) Batten Application , 2L (ft3) Direct Deck Application Villa 900 Concrete Tile 0.291 0.315 NOA No.: 21-0712.03 MIAMI•DAD; COUNTY Expiration Date: 09/21/26 Approval Date: 09/16/21 Page 4 of 7 Table 3: Restoring Moments due to Gravity - M9 ft-lbf.) Tile Profile 2":12" 3":12" 4":12" 5":12" 6":12" 7":12" or greater Villa 900 Concrete Tile Direct Deck Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck Battens Direct Deck 7.70 7.62 6.56 7.50 6.42 7.34 6.26 7.15 6.08 6.95 Table 4: Attachment Resistance Expressed as a Moment - Mf (ft-lbf) for Mechanically Fastened Systems Tile Profile Fastener Type Direct Deck Direct Deck Battens (min 15/32" plywood) (min.19/32" plywood) Villa 900 2-10d Ring Shank Nails 27.8 37.4 28.8 Concrete Tile 1-10d Smooth or Screw 8.8 11.8 4.1 Shank Nail 2-10d Smooth or Screw 16.4 21.9 7.1 Shank Nails 1 #8 Screw 25.8 25.8 22.9 2 #8 Screw 47.1 47.1 49.1 1-10d Smooth or Screw 24.3 24.3 24.2 Shank Nail Field Clip) 1-10d Smooth or Screw 19.0 19.0 22.1 Shank Nail (Eave. Clip) 2-10d Smooth or Screw 35.5 35.5 34.8 Shank Nails Field Clip) 2-10d Smooth or Screw 31.9 31.9 32.2 Shank Nails Eave Clip) Table 5: Attachment Resistance Expressed as a Moment Mf (ft-lbf) for Two Paddy Adhesive' Set Systems Tile Profile Tile Application Minimum Attachment Resistance Villa 900 Concrete Tile TILE BONDTm Roof Tile Adhesive 352 TILE BONDTm Roof Tile Adhesive 673 ICP Adhesives Pol set® AH-160 26.14 Touch'N Seal StormBond®2 555 Touch 'N Seal StormBond® (one component) - 726 1 See foam adhesive manufacturer's component approval for installation requirements. 2 Medium paddy weight of 8 grams per paddy of TILE BONDTm Roof Tile Adhesive 3 Medium paddy weight of 16 grams per paddy of TILE BONDTm Roof Tile Adhesive 4 Medium paddy weight of 8 grams per paddy of Polyset® AH-160 5 Medium paddy weight of 8 grams per paddy of Touch 'N Seal StormBond ® 2 6 Medium paddy weight of 8 grams between tile and underlayment, paddy weight of 5 grams on overlap of the of Touch 'N Seal StormBond ® one component) MAMI•DADE COUNTY , yme NOA No.: 21-0712.03 Expiration Date: 09/21/26 Approval Date: 09/16/21 Page 5 of 7 Table 6: Attachment Resistance Expressed as a Moment - Mf (ft-lbf) for Single Paddy Adhesive Set Systems Tile Tile Application Minimum Attachment Profile, Resistance Villa 900 Concrete Tile LC 86,67 ICP Adhesives Pol set® AH-160 45.58 ouch'N Seal StormBondw2 409 Touch 'N Seal StormBond®2 7010 7 Large paddy weight of 54 grams of Polyset0 AH-160 8 Medium paddy weight of 24 grams of Polyset® AH-160 9 Medium paddy weight of 30 grams of Touch 'N Seal StormBond ® 2 10 Large paddy weight of 60 grams of Touch 'N Seal StormBond ® 2 Table 7: Attachment Resistance Expressed as a Moment - Mf (ft-lbf) for Mortar Set Systems Tile Profile Tile Application Attachment Resistance Villa 900 Concrete Tile Mortar Set" 20.6 11 Bermuda Roof Co. Inc. Tile-Tite Roof Tile Mortar. 5. LABELING 5.1 All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as detailed below, or following statement: "Miami -Dade County Product Control Approved". LABEL FOR BORAL VILLA 900 CONCRETE TILE (LOCATED ON THE UNDERSIDE OF TILE 6. BUILDING PERMIT REQUIREMENTS: 6:1 Application for building permit shall be accompanied by copies of 11 the following: 6.1.1 This Notice of Acceptance. 6.1.2 Any other documents required by Building Official or Applicable building code in order to properly evaluate the installation of this system. NOA No.: 21-0712.03 Expiration Date: 09/21/26 Approval Date: 09/16/21 Page 6 of 7 Villa Nail hales iT' PROFILE DRAWING L12 VILLA 900 CONCRETE ROOF TILE END OF THIS ACCEPTANCE Overlock 13" 21 /8" 1 NOA No.: 21-0712.03 Expiration Date: 09/21/26 Approval Date: 09/16/21 Page 7 of 7