Loading...
HomeMy WebLinkAboutEvaluation Report' copy RECEIVED 0 FOR ®� . hIANCE MEMO etc. t, u U Certificate of Authorization #32455 ST. �PA I ` ®LINTY 353 Christian Street, Unit#13 � Oxford, CT 06478 (203) 262-9245 ENGINEER EVALUATE TEST CONSULT Polyglass USA, Inc. Evaluation Report P12060.02.09-1131 1111 West Newport Center Drive F1.5259-1135 (NON-HVHZ) Deerfield Beach, FL 33442 Date of Issuance: 02/24/2009 (954) 233-1330 Revision 30:12/20/2021 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the Ph Edition (2020) Florida Building Code sections noted herein. LDESCRIPTION: ''Polyglass Roof Underlayments; for use in FBC non=HVHZ jurisdictions LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein and FBC 1507.1.1. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change. Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any changes to the product(s), the QualityAssu►�a�ce or the�roduction facility loca�lon(srNEMO-E TC,-LLC requires a complete review -of its Evaluation Keport vela ivy e to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words "NEMO Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 17. Prepared by: ZZE Robert J.M. Nieminen P.E. Florida Registration No. 59166, Florida DCA ANE1983 ;C.`` " ' • The facsimile seal appearing was authorized by Robert Nieminen, P.E. an 12/20/2021. This does not serve as an electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. S. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. @2019 NEMO ETC, LLC ONEMO I etc. ROOFING COMPONENT EVALUATION: Product Category: Roofing Sub -Category: Underlayment Compliance Statement: Roof Underlayments,, as produced by Polyglass USA, Inc., have demonstrated compliance with the following sections of the Ph Edition (2020) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. Section 1504.3.1 1504.3.1 1507.1.1 / R905.1.1 1507.1.1, 1507.2.4, 1507.2.9.2 / R905.1.1, R905.2.8.2 1507.3.3 / R905.3.3 1507.11.2 / R905.11.2 1507.11.2 / R905.11.2 1507.11.2 / R905.11.2 1507.11.2 / R905.11.2 TAS 110 Property Wind resistance Wind resistance Material standard Material standard Material standard Material standard Material standard Material standard Material standard Accelerated Weathering Entity Examination Reference Date ERD (TST 6049) ASTM D6164 P37590.03.13-3A 03/06/13 ERD (TST 6049) ASTM D6164 P37590.07.13-1 07/02/13 ERD (TST 6049) ASTM D4601 P45940.09.13 09/04/13 ERD (TST 6049) ASTM D1970 (adhesion) P45370.09.13 09/18/13 (TST 6049) TAS 103, ASTERD P45270.05.14 05/12/14 TAS 114(C) TAS (C) ERD (TST 6049) ASTM D3623 P46520.30.14 10/03/14 ERD (TST 6049) FRSA/TRI P44360.30.14-R1 10/07/14 ERD (TST 6049) ASTM D1970, D4798 P43290.10.14 10/17/14 ERD (TST 6049) FRSA/TRI PLYG-SC7550.03.1S 03/24/15 ERD (TST 6049) ASTM D3623 P40390.04.15 04/03/15 ERD (TST 6049) ASTM D1623, TAS 103 PLYG-SC30130.06.16-2 06/27/16 ERD (TST 6049) ASTM D1970, D4798 PLYG-SC10130.06.16-1 06/27/16 ERD (TST 6049) FRSA/TRI PLYG-SC10130.06.16-3 06/27/16 ERD (TST 6049) FRSA/TRI (tile slippage) PLYG-SC33040.12.16 12/27/16 ERD (TST 6049) FRSA/TRI (tile slippage) PLYG-SC12115.08.17 08/08/17 ERD (TST 6049) FRSA/TRI PLYG-SC33035.08.17 10/31/17 NEMO (TST 6049) ASTM D1970 4-PLYG-18-004.03.18 03/29/18 NEMO (TST 6049) ASTM D1623, TAS 103 4S-ICP-18-001.07.18-R1 07/23/18 NEMO (TST 6049) ASTM D6163 4S-PLYG-18-002.01.19-A 01/24/29 NEMO (TST 6049) ASTM D6222 4S-PLYG-18-002.05.19-C 05/20/19 NEMO (TST 6049) FRSA/TRI 4S-PLYG-18-004.10.19-G 10/08/19 NEMO (TST 6049) FRSA/TRI 4S-PLYG-18-004.10.19-1 10/08/19 NEMO (TST 6049) FRSA/TRI 4S-PLYG-18-004.10.19-L 10/09/19 NEMO (TST 6049) FRSA/TRI 4S-PLYG-18-004.12.19-F 12/18/19 NEMO (TST 6049) FRSA/TRI 4J-PLYG-I9-SSUDL-02.A . 01/02/20 NEMO (TST 6049) ASTM D6222 4S-PLYG-18-002.12.19-K-R1 02/07/20 NEMO (TST 6049) ASTM D1970, D4798 4S-PLYG-18-004.01.20.H 01/14/20 NEMO (TST 6049) ASTM 01970, D4798 4S-PLYG-18-004.01.20.K 01/14/20 NEMO (TST 6049) ASTM D6164 4S-PLYG-18-004.01.20.B 01/16/20 NEMO (TST 6049) FRSA/TRI (tile slippage) 4S-PLYG-18-004.01.20A 01/16/20 Standard Year FM 4474 2011 UL 1897 2015 ASTM D226 2009 ASTM D1970 2015 FRSA/TRI, Sixth Edition 2018 ASTM D6163 2015 ASTM D6164 2011 ASTM D6222 2011 ASTM D6509 .2015 ASTM D4798 2011 Entity Examination Reference NEMO (TST 6049) FRSA/TRI 4J-PLYG-20-SSUDL-05.0 NEMO (TST 6049) FRSA/TRI 4J-PLYG-20-SSUDL-11.A NEMO (TST 6049) ASTM D1970,D4798 4S-PLYG-18-004.12.19.D NEMO (TST 6D49) FRSA/TRI 4j-PLYG-I9-SSUDL-M.A NEMO (TST 6049) ASTM D1623, TAS 103 4p-ICP-20-SSLAP-01.A NEMO (TST 6049) NEMO (TST 6049) NEMO (TST 6049) NEMO (TST 6049) NEMO (TST 6049) PRI(TSTS878) ERD (TST 6049) ERD (TST 6049) ERD (TST 6049) ERD (TST 6049) ERD (TST 6049) ERD (TST 6049) ERD (TST 6049) ERD (TST 5049) ERD (TST 6049) ERD (TST 6049) ERD (TST 6049) ERD (TST 6049) ERD (TST 6049) ERD (TST 6049) FM (TST 1867) NEMO (TST 6049) Polyglass USA Polyglass USA Polyglass USA ASTM D3623, TAS 103 ASTM D4798, D3623 ASTM D1623, TAS 103 ASTM D1623, TAS 103 ASTM D1970, D4798 ASTM D3623, TAS 103 Wind Uplift Wind Uplift Wind Uplift Wind Uplift Wind Uplift Wind Uplift Wind Uplift TAS 117(B), TAS 114(C) TAS 114(J) Wind Uplift Wind Uplift Wind Uplift Wind Uplift UL1897 Wind Uplift Wind Uplift PA Affidavit Materials Affidavit Materials Affidavit 4p-ICP-20-SSLAP-03.A-R3 4J-PLYG-2D-SSUDL-13.A 4J-PLYG-20-SSUDL-07.A 4J-PLYG-20-SSUDL-09.A 41-PLYG-2I-SSUDL-03.A DAPF-002-01 11757.04.01-1-R1 11757.08.01-1 11776.06.02 P1740.01.07 P1738.02.07-R2 P9260.03.08 P30540.11.09-R1 P11030.11.09-2 P39680.03.13 P41630.08.13 P11751.05.03-R1 P11781.11.03-R1 PLYG-SC8905.05.16-1 PLYG-SC12025.10.16 FM 30D4091 4L-PLYG-18-003.01.19 Mule -Hide Cross Ltg Polystick Compound Polystick Compound Date 09/30/20 20/21/20 10/27/20 11/18/20 22/15/20 03/04/21 03/15/21 10/29/21 20/29/21 10/29/21 03/08/18 04/25/01 08/13/01 01/16/03 01/04/07 02/05/07 03/21/08 11/23/09 11/30/09 03/04/13 08/06/13 11/26/13 11/26/13 05/17/16 10/12/16 01/12/00 01/11/19 03/01/09 08/18/11 01/13/21 NEMO ETC, I.I.C. Evaluation Report P32060.02.09-1131 Certificate of Authorization N32455 7- EDITION (2020) FBC NON-HVHZ EVALUATION FL5259-1135 (NON-HVHZ) Polyglass Roof Underlayments Revision 31:12/20/2021 Page 2 of 17 Enti Examination Reference Date NEW (TST 6049) ASTM D1623, TAS 103 4p-DOW-I9-SSLAP-01.A-112 02/10/20 NEMO (TST 6049) FRSA/TRI PLYG-SC15855.05.20.A 05/29/20 NEMO (TST 6049) FRSA/TRI 4j-PLYG-20-SSUDL-01 07/06/20 NEMO (TST 6049) ASTM D6222 4q-PLYG-I9-SSMBB-05.A 07/23/20 NEW (TST 6049) ASTM D4798, D3623 4j-PLYG-I9-SSUDL-OSA 09/10/20 M 4.1 4.2 4.3 4.4 4.5 4.6 4.7 4.8 4.9 4.10 4.11 4.12 4.13 4.14 4.15 OMEMO I etc Kn2y Examination Reference Date PRI(TST5878) UL1897 70ST0058-1 01/13/21 PRI(TST5878) UL1897 708TOO58-6 02/17/21 PRI(TST5878) UL1897 70ST0058-7 02/25/21 UL (QUA9625) Quality Control Service Confirmation (FL) 09/13/18 UL (QUA9625) Quality Control Service Confirmation (TX) 11/07/19 UL (QUA9625) Quality Control Florida BCIS Current ORODUCT00d• Product Material Standard Plant(s) Description Elastobase V (formerly ASTM D6163 FL Fiberglass -reinforced, SBS modified bitumen base sheet "Elastobase") Elastobase P ASTM D6164 FL Polyester -reinforced, SBS modified bitumen base sheet Elastoflex S6 G ASTM D6164 FL, PA Polyester -reinforced, SBS modified bitumen cap sheet FRSA/TRI 09-18 Elastoflex S6 G FR ASTM D6164 FL Polyester -reinforced, SBS modified bitumen cap sheet FRSA/TR109-18 HydraGuard Dual Pro ASTM D1970 FL Nominal 60-mil thick dual -layer rubberized asphalt waterproofing membrane, fiberglass reinforced, with a polyester fabric surface HydraGuard Tile Pro ASTM D1970 FL Nominal 60-mil thick dual -layer rubberized asphalt FRSA/TRI 09-18 waterproofing membrane, fiberglass reinforced, with a polyester fabric surface Mule -Hide SA-APP Cap Sheet ASTM D6222 FL Polyester -reinforced, APP modified bitumen cap sheet FRSA/TRI 09-18 Mule -Hide SA-APP Cap Sheet ASTM D6222 FL Polyester -reinforced, APP modified bitumen cap sheet (FR) FRSA/TR109-18 Polyflex G ASTM D6222 FL Polyester -reinforced, APP modified bitumen cap sheet for FRSA/TRI 09-18 use as an alternate to Heat Applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition beneath mechanically fastened or adhered tile roof.systems Polyflex G FR ASTM D6222 FL Polyester -reinforced, APP modified bitumen cap sheet for FRSA/TRI'09-18 use as an alternate to Heat. -Applied "Cap Sheet' in the "Two Ply System" from FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition beneath mechanically fastened tile roof systems Polyflex SA P ASTM D6222 FL, TX Polyester -reinforced, APP modified bitumen cap sheet FRSA/TR109-18 Polyflex SA P FR ASTM D6222 FL, TX Polyester -reinforced, APP modified bitumen cap sheet FRSA/TR109-18 Polybase V (formerly "Polyglass ASTM D6509 FL Fiberglass -reinforced, APP modified bitumen base sheet Base") Polyglass G2 Base Sheet ASTM D4601 AL Fiberglass -reinforced, asphaltic base sheet Polystick IR-Xe ASTM D1970 FL, PA, TX Nominal 60-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, with an aggregate surface NEMO ETC, LLC. Evaluation Report P32060.02.09-1131 Certificate of Authorization N32455 7- EDITION (2020) FBC NON-HVHZ EVALUATION FL5259-R35 (NON-HVHZ) Polyglass Roof Underlayments Revision 31: 22/20/2021 Page 3 of 17 4.16 4.17 4.18 4.19 4.20 ONEMOletc. ••. • Product Material Standard Plant(s) Description Polystick MTS Plus ASTM D1970 FL, NV, Nominal 60-mil thick rubberized asphalt waterproofing FRSA/TRI 09-18 PA, TX membrane, glass fiber reinforced, surfaced with polyolefinic film surface Polystick TU Max ASTM D1970 FL, PA, TX Nominal 60-mil thick rubberized asphalt waterproofing FRSA/TRI 09-18 membrane with a 190 g/mz polyester fabric surface Polystick TU P FRSA/TRI 09-18 FL, PA, TX Nominal 130-mil thick rubberized asphalt waterproofing membrane, glass-fiber/polyester reinforced, with a granular surface Polystick TU Plus ASTM D1970 FL, PA, TX Nominal 80-mil thick rubberized asphalt waterproofing FRSA/TRI 09-18 membrane, glass fiber reinforced, with a polyester fabric surface Polystick XFR ASTM D1970 NV, TX Nominal 80-mil thick rubberized asphalt waterproofing FRSA/TRI 09-18 membrane, glass fiber reinforced, surfaced with a textured film surface 5.1 This is a Building Code Evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC High Velocjty Hu rica_[Ie Zoae�j�irisdictions_(L_e,,BtoyuaLd and11 ' mi- _ade_CQunties) 5.3 This Evaluation Report pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. 5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations concerning the use of foam plastic insulation. 5.5 Polyglass Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. NEMO ETC, I.I.C. Evaluation Report P12060.02.09-1131 Certificate of Authorization #32455 7- EDITION (2020) FBC NON-HVHZ EVALUATION FL5259-1135 (NON-HVHZ) Polyglass Roof Underlayments Revision 31:12/20/2021 Page 4 of 17 Li NNEMOjetc. 5.6 Allowable Roof Covers: TABLE 1: ROOF COVER OPTIONS FBC Section: 1507.2 2507.3 1507.4 and 1507.5 1507.7 1507.8 and 2507.9 Asphalt Clay and Concrete Tile Slate or Slate- Underlayment Metal Wood Mechanical Attach Adhesive -Set Shingles Type Shingles Yes Yes Yes Yes Yes 'Yes Elastobase V (Alternate to (as Base Sheet, (as Base Sheet, (Alternate to (Alternate to (Alternate to D226, Type II) See 5.8.3) See 5.8.3) 0226, Type II) D226, Type II) D226, Type 11) Yes Yes Yes Yes Yes Yes Elastobase P (Altemate to (as Base Sheet, (as Base Sheet, (Alternate to (Alternate to (Alternate to D226, Type 11) See 5.8.3) See 5.8.3) D226, Type 11) D226, Type 11) D226, Type II) Yes Yes Polybase V No (as Base Sheet, (as Base Sheet, No No No See 5.8.3) See 5.8.3) Yes Yes Polyglass G2 Base No (as Base Sheet, (as Base Sheet, No No No See 5.8.3) See 5.8.3) Elastoflex S6 G No Yes Yes No No No (See 5.6.1) Elastoflex S6 G FR No Yes No No No No Yes HydraGuard Dual Pro Yes No No Yes Yes (joint strips,1507.1.1.3 / R905.1.1.3) Yes Yes HydraGuard Tile Pro Yes Yes (see 5.6.1) Yes Yes Qoint strips,1507.1.1.3 / R905.1.1.3) Mule -Hide SA-APP Cap Sheet No Yes es No No No (See 5.6.1) Mule -Hide SA-APP Cap Sheet (FR) No Yes Yes No No No (See 5.6.1) Polyflex G No Yes Yes No No No (See 5.6.1) Polyflex G FR No Yes No No No No Polyflex SA P No Yes Yes No No No (See 5.6.1) Polyflex SA P FR No Yes Yes No No No (See 5.6.1) Yes Polystick IR-Xe Yes No No No Yes (joint strips,1507.1.1.3 / R905.1.1.3) Yes Polystick MTS Plus Yes Yes No Yes Yes (joint strips,1507.1.1.3 / R905.1.1.3) Yes Yes Polystick TU Max No Yes (See 5.6.1) Yes No (joint strips,1507.1.1.3 / R905.1.1.3) Yes Yes Polystick TU P No Yes (See 5.6.1) No No (joint strips,1507.1.1.3 / R905.1.1.3) Yes Yes Polystick TU Pius Yes Yes (See 5.6.1) Yes Yes (joint strips,1507.1.1.3 / R905.1.1.3) Yes Polystick XFR Yes Yes No Yes Yes (Joint strips,1507.1.1.3 / R905.1.1.3) NEMO ETC, I.I.C. Evaluation Report P12060.02.09-1131 Certificate of Authorization #32455 7- EDITION (2020) FBC NON-HVHZ EVALUATION FL5259-R35 (NON-HVHZ) Polyglass Roof Underlayments Revision 31:12/20/2021 Page 5 of 27 ONEMOjetc. 5.6.1 Adhesive -set tile is limited to use of the following underlayment / tile -adhesive combinations. TABLE 1A: ALLOWABLE UNDERLAYMENT/TILE-ADHESIVE COMBINATIONS' Underiayment DAP Foam Dupont ICP Adhesives StormBond StormBond 2 Tile Bond Polyset AH-160 Polyset RTA-1 FL14506 FL14506 FL22525 FL6332 FL6276 Elastoflex S6 G No No No Yes Yes Polyflex G No No No No Yes Polyflex SA P, Mule -Hide SA-APP Cap Sheet No No No Yes Yes Polyflex SA P FR, Mule -Hide SA-APP Cap Sheet (FR) No No No No Yes Polystick TU Max No Yes Yes es Yes Polystick TU P Yes Yes No Yes Yes Polystick TU Plus, HydraGuard Tile Pro No Yes Yes Yes Yes 5.7 Allowable Substrates: TABLE 2: SUBSTRATE OPTIONS FOR ADHERED UNDERLAYMENTS Substrates (designed to meet wind loads for project) Underlayment Application Type Primer Material(s) HydraGuard Dual Pro, Deck / (Optional) ASTM' plywood, OSB, Southefn.Yellow Pine or Huber Engineered "ZIP HydraGuard Tile Pro, Polystick IR- sheathing D41 System" Panels Woods ASTM D41 structural concrete Xe, Polystick MTS Plus, Polystick ASTM ASTM C1289 Type II Class 1 polyisocyanurate, ASTM TU Max, Polystick TU P, Polystick self- TU Plus, Polystick XFR, Mule -Hide adhering(Optional) �1 o�B=3000 _C1289 hype-V-polyisocyanurate-composite,-DensDeck Prime or SECUROCK Gypsum -Fiber Roof Board SA-APP Cap Sheet, Mule -Hide SA- _insulation— APP Cap Sheet (FR), Polyflex SA P ASTM D226, Type II felt, Elastobase V, Elastobase P or or Polyflex SA P FR Base Sheet N/A Mule -Hide Nail Base Deck ASTM D41 structural concrete Elastoflex S6 G or Elastoflex S6 G Insulation (Optional) ASTM DensDeck Prime or SECUROCK Gypsum -Fiber Roof Board FR hot asphalt D41 Base Sheet N/A ASTM D226, Type II felt, Elastobase V, Elastobase P, Mule - Hide Nail Base or Polyglass G2 Base Deck ASTM D41 structural concrete Polyflex G or Polyflex G FR torch- Insulation (Optional) ASTM D41 DensDeck Prime or SECUROCK Gypsum -Fiber Roof Board applied Base Sheet N/A r Elastobase V, Elastobase P, Mule -Hide Nail Base, Polyglass G2 Base or Polybase V 1 Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance. NEMO ETC, I.I.C. Evaluation Report P12060.02.09-1131 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION FL5259-R35 (NON-HVHZ) Polyglass Roof Underlayments Revision 31:12/20/2021 Page 6 of 17 ONEMOletc. 5.8 Attachment Limitations: 5.8.1 For use under mechanically attached NON -TILE prepared roof coverings, attachment shall be in accordance with the manufacturer's installation instructions, but — for mechanically attached underlayments or base sheets - not less than FBC 1507.1.1 or R905.1.1. 5.8.2 For use under the roof systems, attachment shall be in accordance with the manufacturer's installation instructions, but — for mechanically attached base sheets - not less than: • FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A, Table 1(for Two - Ply Asphalt Applied Hot Mop Underlayment) or • Section 5.8.3 herein (for other underlayment systems). 5.8.3 Wind Resistance for Underlayment Systems in Tile Roof Applications: The following wind uplift limitations apply to underlayment systems that are not prescriptive in the FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition. The Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects -the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). \V5.8.3.1 Direct -to -Deck: The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A, Table 1A or the critical (highest) design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. #1 Maximum Design Pressure = -52.5 psf: Deck: APA rated, 7/16 CAT, 0.418 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Joints.—MiTr-4=irrchwiae-stripsorElastoflex'SA-V7sverall-OSB-jairi Base Ply: Polystick MTS Plus, self -adhered. Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick TU P or Polystick TU Plus, self -adhered. #2 Maximum Design Pressure = -90 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: None Base Ply: (Optional) Polystick MTS Plus, self -adhered. Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick TU P or Polystick TU Plus, self -adhered. #3 Maximum Design Pressure = -97.5 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: PG100 or ASTM D41 y Base Ply: (Optional)`Polystick MTS Plus, self -adhered. 1 Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, PolystickTU Max, Polystick TU P or Polystick TO Plus, self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x 1'/0" ring shank nails through 32 ga., 1-5/8" diameter tin caps spaced 12-inch o.c. #4 Maximum Design Pressure = -105 psf: 'Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: WB-3000 Base Ply: (Optional) Polystick MTS Plus, self -adhered. Underlayment: Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick TU Max, Polystick TU P or Polystick TU Plus, self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x 1'/<" ring shank nails through 32 ga.,1-5/8" diameter tin caps spaced 12-inch o.c. NEMO ETC, I.I.C. Evaluation Report P12060.02.09-1131 Certificate of Authorization #32455 7- EDITION (2020) FBC NON-HVHZ EVALUATION FL5259-R35 (NON-HVHZ) Polyglass Roof Underlayments Revision 31:12/20/2021 Page 7 of 17 qu ONEMOletc. #53 Maximum Design Pressure = -127.5 Psf: Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Elastobase V or Polybase V Fasteners: TRUFAST Versa -Fast Fasteners & Plates with one (1) screw per plate, in the center hole. Spacing: 9-inch o.c. at the 4-inch wide side laps and 9-inch o.c. at four (4) equally spaced staggered center rows. Underlayment: Polyflex G, torch -applied. 5.9 Exposure Limitations: TABLE 3: EXPOSURE LIMITATIONS Underlayment Prepared Roof Cover Installation Type Maximum Exposure (days) Elastobase V, Elastobase P, Polyglass G2 Base or Polybase V Mechanically attached 30 Polystick IR-Xe Mechanically attached 90 HydraGuard Dual Pro, HydraGuard Tile Pro, Polystick MTS Plus, Polystick TU Max, Polystick TU P, Polystick TU Plus or Polystick XFR Any type (per Table 1) 180 Elastoflex S6 G, Elastoflex S6 G FR, Mule -Hide SA-APP Cap Sheet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex G, Polyflex G FR, Polyflex SA P or Polyflex SA P FR Adhesive -set the roof system 180 Mechanically attached UNLIMITED 5.10 Tile Slippage Limitations: When loading roof tiles on the underlayment in direct -deck tile roof assemblies, the maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles. TABLE 4: TILE SLIPPAGE LIMITATIONS FOR DIRECT -DECK TILE INSTALLATIONS Under)aymen' Tiie-Profile Staiging Method fiimim-0m Staging Siope Elastoflex S6 G or S6 G FR Flat or Lugged 6-tile stack (4 over 2) Prohibited without battens HydraGuard Tile Pro Flat or Lugged 6-tile stack (4 over 2) 7:12 Polyflex G or G FR Flat or Lugged 6-tile stack (4 over 2) 4:12 Polyflex SA P or SA P FR Flat or Lugged 6-tile stack (4 over 2) 4:12 Polystick MTS Plus Flat 6-tile stack (4 over 2) 5:12 Lugged 6-tile stack (4 over 2) 4:12 Polystick TU Max Flat 6-tile stack (4 over 2) or 10-tile stack 7:1.2 Lugged 6-tile stack (4 over 2) 7:12 Lugged 10-tile stack 6:12 Polystick TU P Flat or Lugged 6-tile stack (4 over 2) 7:12 Polystick TU Plus Flat or Lugged 6-tile stack (4 over 2) 7:12 Flat or Lugged 10-tile stack 6:12 Polystick XFR Flat or Lugged Prohibited without battens Prohibited without battens NEMO ETC, I.I.C. Certlf&ate of Authorization #32455 7- EDITION (2020) FBC NON-HVHZ EVALUATION Polyglass Roof Underlayments Evaluation Report P12060.02.09-R31 FL5259-1135 (NON-HVHZ) Revision 31: 22/20/2021 Page 15 of 17 ONEMOIetc. 6.1 Polyglass Roof Underlayments shall be installed in accordance with Polyglass published installation instructions subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application, and prime the substrate (if applicable). 6.3 Elastobase V, Elastobase P or Mule -Hide Nail Base: 6.3.1 Non -Tile Applications:, Shall be installed in compliance with requirements for an approved mechanically attached underlayment (ASTM D226, Type II) in FBC Table 1507.1.1.1 or FBC.Residential Table 11905.1.1.1 for the type of prepared roof covering to be installed, and the manufacturer's installation instructions. FBC requirements take precedence over the manufacturer's installation instructions. Elastobase V, Elastobase P or Mule -Hide Nail Base may be covered with a layer of Polystick IR-Xe, Polystick MTS Plus, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick XFR, Polyflex SAP, Polyflex SA P FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR), self -adhered, Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt or Polyflex G or Polyflex G FR, torch applied. Roof cover limitations are those are those associated with the top -layer underlayment, as set forth in Table 1. 6.3.2 Tile Applications: 6.3.2.1 Elastobase V (poly -film top), Elastobase P (poly -film top) and Mule -Hide Nail Base are limited to use as a mechanically attached base sheet in the `?WO -PLY SYSTEM" from FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, followed by Polystick MTS Plus, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick XFR, Polyflex SAP, Polyflex SA P FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR), self -adhered or Polyflex G or Polyflex G FR, torch -applied. Tile roof installation method is limited by the selected Cap Sheet, as set forth in Table 1. Refer to Section 5.8.3.2 herein for attachment requirements. 6.3,2.2—F(asttobase3L(sanded--top)_a_n_c- astobase-P—(sanded--top).e_are_limited to-uses-a_mechanically-attached-basesheet-in the "TWO-PLY SYSTEM" from FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, followed by Elastoflex S6 G, Elastoflex S6 G FR or an FBC Approved Mineral Surfaced Cap Sheet (ASTM D6380), asphalt -applied or Polyflex G or Polyflex G FR, torch -applied. Tile roof installation method is limited by the selected Cap Sheet, as set forth in Table 1. • When Elastobase V (sanded -top) or Elastobase P (sanded -top) is followed by asphalt -applied Elastoflex S6 G, Elastoflex S6 G FR or FBC Approved Mineral Surfaced Cap Sheet (ASTM D6380), refer to FRSA/TRI, Sixth Edition, Appendix A, Table 1 or Section 5.8.3.2 herein for attachment requirements. • When Elastobase V (sanded -top) or Elastobase P (sanded -top) is followed by torch -applied Polyflex G or Polyflex G FR, refer to Section 5.8.3.2 herein for attachment requirements. 6.4 6.4.1 6.4.2 HydraGuard Dual Pro, HydraGuard Tile Pro, Mule-Hide,SA-APP'Cap.S'heet, Mule -Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR, Polystick IR-Xe,'Polystick MTS Plus, Polystick TU Max, Polystick TU P, Polystick TU Plus or Polystick XFR: General: All seal -lap seams (selvage laps) must be firmly rolled with a in accordance with Polyglass requirements to ensure full contact and adhesion. For HydraGuard Dual Pro and HydraGuard Tile Pro, align the edge of the top sheet to the end of the glue pattern (the sheet will overlap the fabric). Non -Tile Applications: View of Overlap Seam of HydraGuard Dual Pro and HydraGuard Tile Pro NEMO ETC, U.C. Evaluation Report P12060.02.09-1131 Certificate of Authorization #32455 7- EDITION (2020) FBC NON-HVHZ EVALUATION FL5259-R35 (NON-HVHZ) Polyglass Roof Underlayments Revision 31:12/20/2021 Page 16 of 17 NNEMOjetc. Shall be installed in compliance with requirements for an approved self -adhering underlayment (ASTM D1970) in FBC 1507.1.1.1 or 1507.1.1.3 or FBC Residential R905.1.1.1 or R905.1.1.3 for the type of prepared roof covering to be installed, and the manufacturer's installation instructions. When installed over a mechanically attached base sheet of FBC Approved ASTM D226, Type II felt, Elastobase V, Elastobase P or Mule -Hide Nail Base, the base sheet shall be fastened in accordance with FBC 1507.1.1 or R905.1.1. 6.4.3 Tile Applications (excludes HydraGuard Dual Pro and Polystick IR Xe): Shall be installed in compliance with the requirements for Self -Adhered Membrane set forth in FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition and the manufacturer's installation instructions. Refer to Section 5.8.3 herein for attachment limitations. Refer to Table 4 herein for tile staging limitations. 6.4.4 Multi -.Ply Underlayment Systems: Polystick .MTS Plus or Polystick XFR followed by HydraGuard Tile Pro, Polyflex SA P, Polystick MTS Plus, Polystick TU Max, Polystick TU P, Polystick TU Plus or Polystick XFR is allowable for use under mechanically attached prepared roof systems. Limits of use are those associated with the top -layer material. This is not a requirement, but is allowable if a 2-ply underlayment system is desired. Polystick MTS Plus followed by HydraGuard Tile Pro, Polyflex SA P, Polystick TU Max, Polystick TU P or Polystick TU Plus is allowable for use under adhesive -set tile systems. Limits of use are those associated with the top -layer material. This is not a requirement, but is allowable if a 2-ply underlayment system is desired. 6.5 Elastoflex S6 G.or Elastoflex.S6 G,FR: 6.5.1 Shall be installed in compliance with requirements as an alternate to the "Hot Asphalt Applied Cap Sheet" in the `Two Ply System" in the FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, and the manu of c� sr'insfafla Ion instructions. Refer to Section 5.8.2 and 5.8.3 herein for attachment limitations. Refer to Table 4 herein for tile staging limitations. 6.6 Polyflex G or Polyfle.k G,FR: 6.6.1 Shall be installed in compliance with requirements as an alternate to the "Heat Applied Cap Sheet" in the `Two Ply System" in the FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, and the manufacturer's installation instructions. Refer to Section 5.8.3 herein for attachment limitations. Refer to Table 4 herein for tile staging limitations. As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this product. Contact the named QA entity for manufacturing facilities covered by F.A.C. Rule 61620-3 QA requirements. Refer to Section 4 herein for products and production locations having met codified material standards. UL LLC—QUA9625; (360) 817-5512; Vinvcia.Seman@ul.com - END OF EVALUATION REPORT - NEMO ETC, I.I.C. Evaluation Report P32060.02.09-1131 Certificate of Authorization #32455 7- EDITION (2020) FBC NON-HVHZ EVALUATION FL5259-R35 (NON-HVHZ) Polyglass Roof Underlayments Revision 32: 22/20/2021 Page 17of17