Loading...
HomeMy WebLinkAboutEnergy Efficiency Code0 1e�_0 S2)(P FORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: LEIGHTON ADDITION Builder Name: Street: 132 NE LOBSTER AVENUE Permit Office: City, State, Zip: PORT ST. LUCIE, FL, Permit Number: Owner: Jurisdiction: Design Location: FL, Fort Pierce County: St. Lucie(Florida Climate Zone 2) 1. New construction or existing Addition 10. Wall Types(480.0 sqft.) Insulation Area 2. Single family or multiple family Detached a. Frame - Wood, Exterior R=19.0 368.00 ft2 b. Frame - Wood, Exterior R=11.0 112.00 ft 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 1 d. N/A R= ft2 5. Is this a worst case? No 11. Ceiling Types(432.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 432.00 ft2b. 6. Conditioned floor area above grade (ft2) 435 NIA R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 7. Windows(24.0 sqft.) Description Area 12. Ducts, location & insulation level R ft2 a. U-Factor: Sgl, U=0.65 24.00 ftZ a. a. Sup: Attic, Ret: Attic, AH: Attic 6 87 SHGC: SHGC=0.25 b. b. U-Factor: N/A ft2 C. SHGC: 13. Cooling Systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a. Central Unit 43.5 SEER:14.00 SHGC: Area Weighted Average Overhang Depth: 2.000 ft Area Weighted Average SHGC: 0.250 14. Heating Systems kBtu/hr Efficiency 8. Skylights Description Area a. Electric Strip Heat 27.0 COP:1.00 U-Factor:(AVG) N/A NIA ft2 SHGC(AVG): N/A 15. Hot Water Systems -None required 9. Floor Types Insulation Area ft2 a. u@ Cap: N/A a. Slab -On -Grade Edge Insulation R= 0.0 432.00 b. Conservation features c. N/A R= ft2 16. Credits None Glass/Floor Area:0.055 Total Proposed Modified Loads: 13.71 PASS Total Baseline Loads: 13.80 I hereby certify that the plans and specifications covered by Review of the plans and �t1E ST 921 this calculation are in compliance with the Florida Energy specifications covered by this pSc _ Code. calculation indicates compliance c�1' with the Florida Energy Code. PREPARED BY: Before construction is completed this building will be inspected for DATE: 9-9-2021 compliance with Section 553.908 is Florida Statutes. . �G'Op I hereby certify that this building, as i ed i ompliance WF with the Florida Energ - e. OWNER/AG 4 BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance with a proposed duct leakage On requires a PERFORMANCE Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNETIICC 380, is not greater than 0.000 On for whole house. - Compliance requires an Air Barrier and Insulation Inspection Checklist In accordance with R402.4.1.1 and this project requires a PERFORMANCE envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). 9/8/2021 9:49:06 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edi n • Q2 r li t 3 Par ' Page 1