HomeMy WebLinkAboutEnergy Efficiency Code0 1e�_0 S2)(P
FORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: LEIGHTON ADDITION
Builder Name:
Street: 132 NE LOBSTER AVENUE
Permit Office:
City, State, Zip: PORT ST. LUCIE, FL,
Permit Number:
Owner:
Jurisdiction:
Design Location: FL, Fort Pierce
County: St. Lucie(Florida Climate Zone 2)
1. New construction or existing
Addition
10. Wall Types(480.0 sqft.)
Insulation Area
2. Single family or multiple family
Detached
a. Frame - Wood, Exterior
R=19.0 368.00 ft2
b. Frame - Wood, Exterior
R=11.0 112.00 ft
3. Number of units, if multiple family
1
c. N/A
R= ft2
4. Number of Bedrooms
1
d. N/A
R= ft2
5. Is this a worst case?
No
11. Ceiling Types(432.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 432.00 ft2b.
6. Conditioned floor area above grade (ft2)
435
NIA
R= ft2
Conditioned floor area below grade (ft2)
0
c. N/A
R= ft2
7. Windows(24.0 sqft.) Description
Area
12. Ducts, location & insulation level R ft2
a. U-Factor: Sgl, U=0.65
24.00 ftZ
a. a. Sup: Attic, Ret: Attic, AH:
Attic 6 87
SHGC: SHGC=0.25
b.
b. U-Factor: N/A
ft2
C.
SHGC:
13. Cooling Systems
kBtu/hr Efficiency
c. U-Factor: N/A
ft2
a. Central Unit
43.5 SEER:14.00
SHGC:
Area Weighted Average Overhang Depth:
2.000 ft
Area Weighted Average SHGC:
0.250
14. Heating Systems
kBtu/hr Efficiency
8. Skylights Description
Area
a. Electric Strip Heat
27.0 COP:1.00
U-Factor:(AVG) N/A
NIA ft2
SHGC(AVG): N/A
15. Hot Water Systems -None required
9. Floor Types Insulation
Area
ft2
a. u@
Cap: N/A
a. Slab -On -Grade Edge Insulation R= 0.0
432.00
b. Conservation features
c. N/A R=
ft2
16. Credits
None
Glass/Floor Area:0.055 Total Proposed Modified Loads: 13.71
PASS
Total Baseline
Loads: 13.80
I hereby certify that the plans and specifications covered by
Review of the plans and
�t1E ST
921
this calculation are in compliance with the Florida
Energy
specifications covered by this
pSc _
Code.
calculation indicates compliance
c�1'
with the Florida Energy Code.
PREPARED BY:
Before construction is completed
this building will be inspected for
DATE: 9-9-2021
compliance with Section 553.908
is
Florida Statutes.
.
�G'Op
I hereby certify that this building, as i ed i
ompliance
WF
with the Florida Energ - e.
OWNER/AG 4
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance with a proposed duct leakage On requires a PERFORMANCE Duct Leakage Test Report confirming duct
leakage to outdoors, tested in accordance with ANSI/RESNETIICC 380, is not greater than 0.000 On for whole house.
- Compliance requires an Air Barrier and Insulation Inspection Checklist In accordance with R402.4.1.1 and this project
requires a PERFORMANCE envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2).
9/8/2021 9:49:06 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edi n • Q2 r li t 3 Par ' Page 1