Loading...
HomeMy WebLinkAboutSewage Construction Inspection & Final ApprovalSHB S APPLICATION # : A►P1294020 STATE OF FLORIDA PERMIT #:56-SF=1768472 DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM DOCUMENT #: F11154244 CONSTRUCTION INSPECTION AND FINAL APPROVAL DATE PAID:06/07/2017 �O uti FEE PAID:51.5.00 RECEIPT #.:56=P[D-3262859 APPiICANT: Harry Blue Builders AGENT: Atlantic Land Design PROPERTY ADDRESS: TBD Spring Hill Dr Jensen Beach, FL,34957 LOT': 6 SUBDIVISION: BLOCK: 1 Spring Hill ID#,. 4504-604=0013-0007 CHECKED [X] ITEMS ARE NOT IN COMPLIANCE WITH STATUTE OR RULE AND MUST BE CORRECTED. TANK INSTALLATION SETBACKS [ ] [O1] TANK SIZE [1] 1050.00 [2] [ ] [271 SURFACE WATER FT [ ] [02] TANK MATERIAL Concrete [ ] [28] DITCHES FT [ ] [03] OUTLET DEVICE [ ] [29] PRIVATE WELLS 100 FT [ ] [04] MULTI -CHAMBERED [ Y N ] [ ] [30] PUBLIC WELLS FT [ ] [05] OUTLET FILTER Polylok PL-68 [ ] [31]. IRRIGATION WELLS FT [ ] [06] LEGEND 1. 01-011-09DC3 2.. [ ] [321 POTABLE WATER 75 FT [ ] [07] WATERTIGHT [ ] [33) BUILDING FOUNDATIONS 6 FT [ ] [08] LEVEL [ ] [34] PROPERTY LINES 19 FT [ ] [09] DEPTH TO LID [ ] [35] OTHER FT DRAINFIELD INSTALLATION FILLED / MOUND SYSTEM [ ] [10] AREA [1] 420 [2] SOFT [ ] [36] DRAINFIELD COVER [ ] [11] DISTRIBUTION BOX HEADER X [ ] '[37]' SHOULDERS [ ] [121 NUMBER OF DRAINLINES 1. 7.00. 2.. [ ] [:38] SLOPES [ ] [131 DRAINLINE SEPARATION [ ] (39] STABILIZATION [ ] [14) DRAINLENE SLOPE [ ] [15] DEPTH OF COVER ADDITIONAL INFORMATION [ ] [16] ELEVATION [ ABOVE / BELOw )BM 2.00 [ ] [401 UNOBSTRUCTED AREA [ ] [17] SYSTEM LOCATION [ ] [41] STORMWATER RUNOFF [ ] [181 DOSING PUMPS [ ] [42] ALARMS [(] [19] AGGREGATE SIZE [ ] [43] MAINTENANCE AGREEMENT [ ] [20] AGGREGATE EXCESSIVE FINES [ ] [44] BUILDING AREA [ ] (21] AGGREGATE DEPTH [ ] [451 LOCATION CONFORMS WITH SITE PLAN [ ] (46] FINAL SITE GRADING FILL / EXCAVATION MATERIAL [ ] [22] FILL AMOUNT [ ] [47] CONTRACTOR David Whiteside (Accurate Se [ ] [23] FILL TEXTURE t ] [48] OTHER [ ] [24] EXCAVATION DEPTH ABANDONMENT [ ] [25] AREA REPLACED [ ] [491 .TANK 'PUMPED ( ] [261 REPLACEMENT MATERIAL [ ] [50] TANK CRUSHED & FILLED Comments: Comments are on page 2. [ APPROVED / 6 ) - `^-� r'— St. Lucie CHD CONSTRUCTION DISAPPROVED ] ° Environmental Speclallst ll Br - Ingram (ENVIRONMENTAL HEALTH) FINAL SYSTEM [ APPROVED / DISAPPROVED ]r \� St. Lucie CHD Environmental Specialist 11 Bri Ingram (ENVIRONMENTAL HEALTH) (Explanation of Violations on following page) DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, PAC EH Database v 1.0.1 AP1194020 EID1768472 DATE: 01/29/2018 DATE 01 /29/2018 Page 2 of 3 FED 2 2w r STATE OF FLORIDA DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM CONSTRUCTION INSPECTION AND FINAL APPROVAL APPLICATION # : AP1294020 PERMIT #•;56-SF=1768472 DOCUMENT # : F 11154244 DATE PAID:'06/07/2017 FEE PAID.,515.00 RECEIPT #:56-PID-3262859 Violation Number Comment is vThe system is sized for 3 bedrooms withh-a maximum occupancy of persons (2 per bedroom), for a total estimated flow of 300 gpd. New ST and 7x5 long DF installed. No violations system ok to cover'.. Contractor notified onsite: No final inspection required. Final system approved. Contractor and.building. department emailed final approyal. DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, FAC Page 2 0£ 3 EH Database v 1.0.1 AP1294020 EID1768472