Manufacture Spec's
Load test Resulis .
The sample below was tested by pull testing hoxizi6ntally 36" from
base with accu-force250f6rce gauges, s/n 62988075 X�pole 64.4
with .063 aluminum extrusion: pole.
Baby Guard mesh tested tensile strength ASTM D,GRAB
METHOD V 157LB11S. BURSTING STRENGTH MULLEN
TESTER ASTM •) 5034 D, 3786 ,3787and g 53 0257 LBS.
'Completed pool fence is assembled with x-pole and Baby Guard
rAesh tensioned betw6en x-poles, comprising of 5 poles .per .10 foot
or 1.2 foot section. Poles inserted with plastic composite sl6eves
into pool decking Sand Set Pavers, concrete, wood} and sections
connected with safety eonhectors. The product completely
assembled and installed: will withstand 321.4 lbs burst. All mesh
has a minimum of 90% transparency testing results provided by:
American test Labs of South Florida and Nutting engineers of
Florida Testing' anti c6nsutting services. Testing report-ATL
report.# 0809.03-03 in: conjunction with Baby Guard Inc.
in compliance with ASTM standard F-2286-05
**In compliance with. Building: 'code #424.2.17 pool hairier 2004
** In Compliance with California code 1159920-115929
**In compliance with! R-4101.1-7.1.15fbc-04
**Minimum fence height its 48".
! **Fence will be installed a. mmi lmuxn of 20" off pool's edge.
**Fence will be, permanendy attached in one area (a tool must be
used to remove fence);. **;*see attached exhibit