Loading...
HomeMy WebLinkAboutBoundary Survey 2-18-22LEGAL DESCRIPTION LOT 3, BLOCK 145, LAKEWOOD PARK, UNIT II, .-SURVEY-z' AS RECORDED IN PLAT BOOK 11, PAGES 32-32D, CONSULTANTS UBLIC RECORDS OF SAINT LUCIE CzOUN;TY7, COUNTY, FLORIDA. t fit\_...4! YS �V FORMBOARD SURVEY PERMIT#: XX))0OOO )D LOT 21 A 22.46' SIR 5/8" "LB 7821" ' ,.LOT 2 FFE-22.84' .. d a w co 0o O 0 O O z SIR 5/8" "LB 7821 " LOT 21 FFE-22.08' N89051'44"W(P&M) 90.00' P&M) 10.0' D.U.E. LOT 3 BLOCK 145 00 o 18.55' 34.6' FORMBOARD o FFE:22.53' b 3.6' o 37.00' 10.9' n4l 20.0' 18.35' Cl 1 9.7 M 90.00'(P&M) N89051'44"W(P&M) FND NAIL BM o P ELV=20.62'-t L LEGEND dt: ABBREVIA110NS PSM - PROFESSIONAL SURVEYOR & MAPPER LB = LICENSED BUSINESS LS = LICENSED SURVEYOR FND = FOUND SET = SET "LB 7821" IR[C]= IRON ROD [& CAP] N D = NAIL & DISK C ON= CONCRETE MONUMENT DW = DRIVEWAY SW = SIDEWALK EC = CONCRETE EP = PAVEMENT R/W = RIGHT—OF—WAY ((33 DRAINAGE CONDITIONER EASEMENT PAD) U.E. = UTILITY EASEMENT WBF = WOOD BOARD FENCE CLF = CHAIN LINK FENCE WVF = WHITE VINYL FENCE P = PLAT M = MEASURED = CLEANOUT ® = WATER METER ® = CABLE RISER ® = TELEPHONE RISER EM = ELECTRIC RISER t0� = POWER POLE ® = WELL ®S = SANITARY SEWER MANHOLE OE —W - OVERHEAD ELECTRIC WATER PIPE CABLE 111 1 _ 70.0' R/W (� y X — DEER PARK AVENUE 0 15 30 LA" 1 INCH = 30 FEET JOB NUMBER 20-12-041 LOT 20A FFE-21.97' SIR 5/8" "LB 7821 " LOT 4 FFE- 22.19' a w 0 00 O 0 O O z SIR, 5/8" "LB 7821 " 0 0 M�'-TND NAIL BM ELV=20.71' qzr— — FND N/D "LB 5569" MODEL: LOT SIZE: X 23.4 = GROUND ELEVATION 1246-B RH 11,790 SQ. FT. �® = PROPOSED DRAINAGE BOUNDARY SURVEY CERTIFIED TO: PROPERTY ADDRESS: _ ARROW CENTURY COMPLETE 7202 DEER PARK AVEUE,{° 3 `}� = PROPOSED ELEVATION FT PIERCE, FL o o ® = PROPOSED 12"X18" CORRUGATED METAL PIPE SURVEYOR'S N07ES I HEREBY CERTIFY THAT THIS SURVEY IS 1. BASIS OF BEARING - THE EASTERLY LINE OF LOT 3 BLOCK 145, LAKEWOOD TRUE AND CORRECT TO THE BEST OF PARK, UNIT II,AS RECORDED IN PLAT BOOK 11, PAGES 32-32D, PUBLIC RECORDS MY KNOWLEDGE, AND THAT THIS SURVEY OF SAINT LUCIE COUNTY COUNTY, FLORIDA, AS BEING N00'08'16"E PER PLAT. MEETS THE STANDARDS OF PRACTICE AS REQUIRED BY CHAPTER 5J-17 FLORIDA 2. DATE OF FIELD SURVEY: 12/29/2020; SITE PLAN: 2/9/21, FORMBOARD BOARD OF LAND SURVEYORS PURSUANT 11/10/2021. TO SECTION 472.027 FLORIDA STATUTES. 3. ADDITIONS OR DELETIONS TO SURVEY MAPS OR REPORTS BY OTHER THAN THE SIGNING PARTY OR PARTIES IS PROHIBITED WITHOUT WRITTEN CONSENT OF THE SIGNING SURVEYOR. This Item has been electronically signed and 4. PROPERTY LINES SHOULD NOT BE ESTABLISHED USING FENCE OR BUILDING TIES. sealed by Dustin W Holloway, PSM on [Date/Time Stamp,,,,*9,wn1 using a digital 5. NO UNDERGROUND INSTALLATIONS OR IMPROVEMENTS, INCLUDING BUT NOT signature. Printgd='egpies.,ob.this document are not and the LIMITED TO, BURIED UTILITIES, FOUNDATIONS AND FOOTERS WERE LOCATED. signature must?�.bd vcrj*'gd`�,any electronic 6. BASED UPON MY REVIEW OF THE "FLOOD INSURANCE RATE MAP" OF ST. LUCIE �aopies,� ', 9 COUNTY, FLORIDA, COMMUNITY PANEL NO. 12111CO070J, EFFECTIVE DATE 'Y, R .• 2416/2020 THIS PROPERTY IS LOCATED WITHIN FLOOD ZONE DEFINED AS AEAS DETtRMINED TO BE OUTSIDE OF THE 0.2% ANNUAL CHANCE FLOODPLAIN. 7. NO INSTRUMENTS OF RECORD REFLECTING OWNERSHIP OR ENCUMBRANCES WERE PROVIDED, EXCEPT AS NOTED, NOR DID THIS SURVEYOR ABSTRACT THESE LANDS. 8. SURVEY FILE NUMBER: 20-12-041 DUSTIN W HOLLOWAY, P.S.M. LS 6676 H&H SURVEY CONSULTANTS, LL LB 7821 9. ELEVATIONS SHOWN HEREON ARE BASED ON THE NORTH AMERICAN VERTICAL DATUM OF 1988 (NAVD88), AND MORE SPECIFICALLY TO THE FLORIDA PERMANENT REFERENCE NETWORK (FPRN) CONTINUOUSLY OPERATING REFERENCE STATIONS (CORS) FLFR, STEW & FLFD. r31 W Broadway, Suite 1001, Oviedo, FL 32765 www.hnhsurvey.com 407.542.4977