HomeMy WebLinkAbout10. Duct Layout - 2401 Noble Oaks - Dudley ResidenceJob #: 1604
Performed by Vicki Lynne Nisa for:
Oleander Model 3
2401 Noble Oaks Lane
Ft Pierce, FL 34981
Air Calcs, LLC
7550 Hidden Hammock Ln
Vero Beach, FL 32966
Phone: 772.800.8413
www.aircalcs.com vickilynne@aircalcs.com
Scale: 1 : 141
Page 1
Right-Suite® Universal 2021
21.0.08 RSU27054
2021-Aug-26 11:24:18
...soft HVAC\2401 Noble Oaks Ln.rup
N
Level 1
Garage
Bed 2
Arrival Center
Laundry
Sto
Butlers Pantry
Clst
Bath 2
Foyer
Den
Wtr Clst
Master Bath
Hers
His
Master Bedroom
Great Room
Bed 3
Bath 3
Flex Space
Hall
Dining
Kitchen
2'8"W x 6'4"H
6'0"W x 8'0"H
5'4"W x 6'4"H
2'0"W x 2'0"H
2'0"W x 2'0"H
2'0"W x 2'0"H
1'11"W x 6'4"H
1'11"W x 6'4"H
1'8"W x 4'5"H3'0"W x 5'2"H
3'0"W x 3'0"H
5'4"W x 2'0"H
6'0"W x 2'0"H
3'0"W x 5'2"H
3'0"W x 3'0"H
6'0"W x 5'2"H
2'7"W x 8'0"H
9'0"W x 5'2"H
6'0"W x 8'0"H
12'0"W x 8'0"H
9'0"W x 5'2"H
8 x 4
29 cfm
8 x 4
19 cfm
12 x 12
89 cfm
12 x 12
120 cfm
12 x 12
106 cfm
36 x 18
1007 cfm
8 x 8
78 cfm
8 x 4
27 cfm
8 x 4
19 cfm
8 x 4
35 cfm
8 x 4
4 cfm
10 x 6
106 cfm
10 x 10
154 cfm
8 x 4
47 cfm
8 x 4
3 cfm
10 x 6
120 cfm
10 x 6
89 cfm
8 x 8
117 cfm
8 x 8
117 cfm
12 x 8
193 cfm
12 x 8
193 cfm
12 x 12
193 cfm 8 x 4
43 cfm
10 x 10
198 cfm
10 x 10
174 cfm
H/W F
F
F
F
DUCTS IN THE GARAGE AND
DUCTS PENETRATING THE
WALLS OR CEILINGS
SEPARATING THE DWELLING
FROM
THE GARAGE SHALL BE
CONSTRUCTED OF A MINIMUM
NO.
26 GAGE (0.48 MM) SHEET
STEEL, 1 INCH MINIMUM RIGID
NONMETALLIC CLASS 0 OR
CLASS 1 DUCT BOARD, OR
OTHER APPROVED MATERIAL
AND SHALL HAVE NO
OPENINGS INTO THE GARAGE
50 CFM
4" Duct
4"Exhaust Vent
80 CFM
4" Duct
4"Exhaust Vent
50 CFM
4" Duct
4"Exhaust Vent
100 CFM
6" Duct
6"Exhaust Vent
6 "
4 "
7 "
4 "
7 "
4 "
4 "
9 "
9 "
4 "
4 "5 "
6 "
14 "
16 "
7 "
7 "
6 "
8 "
4 "
9 "
4 "
4 "
14 x 14
243 cfm
10 x 6
88 cfm
12 "
6 "
18 "
7 "
9 "
7 "
10 "
12 "
7 "12 "
9 "