Loading...
HomeMy WebLinkAbout3. Plans for Building (Part A) - 2401 Noble Oaks - Dudley ResidenceScaleVILLADELTA CONSTRUCTION CORP. LLC CRC 058035THE DESIGN PROFESSIONAL OF RECORD (ENGINEER AND/OR ARCHITECT) ASSUMES ALL RESPONSIBILITY OF THE SPECIFICATIONS CONTAINED HERE IN. IT IS THE CLIENT'S AND/OR CONTRACTOR'S RESPONSIBILITY TO VERIFY THE FINAL PLANS AND MEASUREMENTS. ALL CHANGES FROM THIS POINT FORWARD WILL NEED A SIGNED CHANGE ORDER BEFORE ANY ADDITIONAL WORK OR MODIFICATIONS WILL BE MADE. ALL WRITTEN CHANGE ORDERS SUPERCEED THE DRAWINGS. THE DRAWINGS ARE CONCEPTUAL DESIGNS AND MAY VARY FROM THE FINISHED PROUCT. THESE DRAWINGS ARE THE PROPERTY OF THE DISIGNER AND SHALL NOT BE REPRODUCED, MODIFIED OR ALTERED WITHOUT PRIOR WRITTEN CONSENT. THESE DRAWINGS WILL REMAIN THE PROPERTY OF THE DESIGNER EVEN IF THEY ARE NOT USED IN THE CONSTRUCTION OF THIS PROJECT. COPYRIGHTT 2016 PRONTO PLANS, L.L.C. ___________________________________CLIENT'S APPROVAL DATE 11/24/2021 12:48:39 AM Cover2401 Noble Oaks LaneFt. Pierce, FL 34981Dudley ResidenceDrawing List Sheet Number Sheet Name A-1 Notes A-2 Floor Plan A-3 Elevations Front & Rear A-4 Elevations Left & Right A-5 Schedules C-1 Site Plan E-1 Electrical Plan M-1 Duct Layout P-1 Plumbing Plan S-1 Foundation Plan S-2 Sections S-3 Floor Framing Plan S-4 Details S-5 Details 2 S-6 Truss Connectors S-7 Exterior Wall Openings Project Information & Design Criteria Building Code: FBC 2020 7th Edition w/All Amendenments Project Name:Project Address: Type of Construction: CBS Frame Building Designed: Enclosed Open Partially Enclosed Wind Speed (3 Sec. Gust): 160 M.P.H. 170 M.P.H. Exposure: C Internal Pressure Coefficient: +/- 0.18 Importance Factor: 1.0 Mean Building Height: <20 ft. Exposure Coefficient: Overhang 1’ 8” ft.Roof Pitch: 5/12 Components & Cladding Wind Pressure: Roof Dead Load: ShinglesTile Metal Framed Floor Live Load NA P.S.F. Dead Load NA P.S.F. Shutters: Yes No Impact Resistant Assembly: YesNo Design Pressure Garage Door: +26.4 -29.4 (16') +27.6 -31.2 (8') All Other Openings: +31.2 -41.0 DRIVING DIRECTIONS (REFER TO MAP BELOW): ENTRANCE TO NOBLE OAKS ESTATES ACROSS FROM GREY TWIG JUST SOUTH OF MIDWAY ROAD AND ST. JAMES/25TH STREET OPENING PROTECTION ALL NEW OPENINGS ARE MIAMI DADE IMPACT RATED, PLEASE REFER TO PRODUCT LIST ON THIS PAGE, BOTTOM LEFT.Rev. # DescriptionDateI HEREBY CERTIFY AS THE BUILDING DESIGN ENGINEER OF RECORD, THAT THE BUILDING DESIGN AS SHOWN ON THESE PLANS (STRUCTURAL COMPLIANCE ONLY) AND AS ACCOMPANIED BY DESIGN AND SUPPORT DOCUMENTS, CONFORMS TO THE 2020 7th EDITION FLORIDA BUILDING CODE. THIS CERTIFICATION DOES NOT INCLUDE ROOF TRUSS COMPONENTS OF WHICH THE TRUSS DESIGN ENGINEER IS THE ENGINEER OF RECORD. THESE PLANS HAVE BEEN PREPARED IN COMPLIANCE WITH THE 2020 7th EDITION FLORIDA BUILDING CODE WITH SUPPLEMENTS. Craig E. Gunderson, P.E. #060102 Date: FLORIDA ENGINEERING, LLC 4161 TAMIAMI TRAIL, UNIT 101 PORT CHARLOTTE, FL. 33952 PH: (941) 391-5980 FAX: (941) 979-8196 ScaleVILLADELTA CONSTRUCTION CORP. LLC CRC 058035THE DESIGN PROFESSIONAL OF RECORD (ENGINEER AND/OR ARCHITECT) ASSUMES ALL RESPONSIBILITY OF THE SPECIFICATIONS CONTAINED HERE IN. IT IS THE CLIENT'S AND/OR CONTRACTOR'S RESPONSIBILITY TO VERIFY THE FINAL PLANS AND MEASUREMENTS. ALL CHANGES FROM THIS POINT FORWARD WILL NEED A SIGNED CHANGE ORDER BEFORE ANY ADDITIONAL WORK OR MODIFICATIONS WILL BE MADE. ALL WRITTEN CHANGE ORDERS SUPERCEED THE DRAWINGS. THE DRAWINGS ARE CONCEPTUAL DESIGNS AND MAY VARY FROM THE FINISHED PROUCT. THESE DRAWINGS ARE THE PROPERTY OF THE DISIGNER AND SHALL NOT BE REPRODUCED, MODIFIED OR ALTERED WITHOUT PRIOR WRITTEN CONSENT. THESE DRAWINGS WILL REMAIN THE PROPERTY OF THE DESIGNER EVEN IF THEY ARE NOT USED IN THE CONSTRUCTION OF THIS PROJECT. COPYRIGHTT 2016 PRONTO PLANS, L.L.C. ___________________________________CLIENT'S APPROVAL DATE 11/24/2021 12:48:30 AM A-12401 Noble Oaks LaneFt. Pierce, FL 34981Dudley ResidenceGENERAL NOTES: THE BUILDER SHALL REVIEW DRAWINGS IN THEIR ENTIRETY BEFORE STARTING WORK. THE BUILDER SHALL ACCEPT FULL RESPONSIBILITY FOR ANY ERROR OR OMISSIONS NOT REPORTED IMMEDIATELY IN WRITING TO ENGINEER OF RECORD. BY SUBMITTING THESE PLANS FOR PERMIT THE BUILDER ACCEPTS FULL RESPONSIBILITY FOR THE ACCURACY OF THE INFORMATION DEPICTED WITHIN AND IT IS ASSUMED THE BUILDER HAS READ AND UNDERSTANDS THE NOTES BELOW. DESIGN LOADS IN ACCORDANCE WITH 2020 FBC 7TH EDITION CHAP. 16 ASSUMED SOIL BEARING CAPACITY MINIMUM: 2500 PSF STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH JOB SPECIFICATIONS AND ARCHITECTURAL, MECHANICAL, ELECTRICAL, PLUMBING, AND SITE DRAWINGS CONSULT ARCHITECTURAL DRAWINGS FOR SLEEVES, DEPRESSIONS, AND OTHER DETAILS NOT SHOWN ON STRUCTURAL DRAWINGS. ALL DETAILS AND SECTIONS SHOWN ON THE DRAWINGS ARE INTENDED TO BE TYPICAL AND SHALL BE CONSTRUED TO ANY SIMILAR SITUATION ELSEWHERE ON THE PROJECT, EXCEPT WHERE A DIFFERENT DETAIL IS SHOWN. ALL DIMENSIONS AND CONDITIONS MUST BE VERIFIED IN FIELD. DO NOT SCALE DRAWINGS. FOLLOW WRITTEN DIMENSIONS ONLY. IF ANY DISCREPANCIES ARE DISCOVER THE ENGINEER OF RECORD MUST BE CONTACTED BEFORE THE COMMENCEMENT OF CONSTRUCTION. THE STRUCTURE IS DESIGNED TO BE SELF SUPPORTING AND STABLE AFTER BUILDING IS COMPLETE. IT IS THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE ERECTION PROCEDURES TO ENSURE SAFETY OF THE BUILDING AND ITS COMPONENTS DURING ERECTION. THIS WORK INCLUDES THE ADDITION OF NECESSARY SHORING, SHEETING, TEMPORARY BRACING, GUYS OR TIEDOWNS. THE CONTRACTOR SHALL SUPPLEMENT THE MINIMUM REQUIRED FOUNDATION AND SITE PREPARATION REQUIREMENTS AND SLAB-ON-GRADE THICKNESS TO HANDLE CONSTRUCTION LOADS. THE STRUCTURAL FRAMING SHOWN IS SCHEMATIC IN NATURE. HOWEVER, THE SUPPORTING STRUCTURE HAS BEEN DESIGNED UNDER THE ASSUMPTION THE FRAMING SCHEME SHOWN WILL CLOSELY PARALLEL FINAL FLOOR DESIGNERS LAYOUT. PROVIDE SIGNED AND SEALED SHOP DRAWINGS AND CALCULATIONS FOR APPROVAL. REVIEW OF SHOP DRAWINGS IS REQUIRED AS THE ENGINEER CHECKS BEAM, WALL, COLUMN AND FOOTING CAPACITIES AGAINST KNOW LOADING. FAILURE TO PROVIDE SHOP DRAWINGS MAY RESULT IN ADDITIONAL ENGINEERING COSTS DURING CONSTRUCTION. FORMWORK NOTES: FORMWORK SHORING, AND BRACING FOR ALL CONCRETE BEAMS, COLUMNS, WALLS, AND FOOTINGS SHALL BE DESIGNED AND CONSTRUCTED IN ACCORDANCE WITH A.C.I 347, "RECOMMENDED PRACTICE FOR CONCRETE FORMWORK". ANY AND ALL PLUMBING PIPE PENETRATIONS THROUGH FORMED WORK SHOULD BE DONE SO THAT REINFORCING STEEL IS NOT DISRUPTED AND COVER FOR STEEL IS NOT AFFECTED ANY UTILITY PIPES PENETRATING FOOTERS TO BE PROPERLY SLEEVED TO AVOID PIPED UTILITIES FROM BEING SHEARED DURING SETTLEMENT OF STRUCTURE ELECTRICAL PIPES INSIDE OF THE POURED COLUMNS SHALL NOT TAKE UP MORE THAN 10% OF THE CROSS-SECTIONAL AREA OF THE COLUMNS AND THEY DO NOT AFFECT THE COVER ON THE REINFORCING STEEL WELDED WIRE MESH: WELDED WIRE MESH SHALL BE ASTM A185, GRADE 65, FREE FROM OIL, SCALE, AND RUST AND SHALL BE PLACED IN ACCORDANCE WITH ACI TYPICAL DETAILS. MINIMUM LAP SHALL BE ONE SPACE PLUS TWO INCHES. CONCRETE NOTES: CONCRETE HAS BEEN PERFORMED IN ACCORDANCE WITH ACI 318-05, BUILDING CODE REQUIREMENTS FIR STRUCTURAL CONCRETE NORMAL WEIGHT CONCRETE (145 PCF) 28-DAY COMPRESSIVE STRENGTHS. PILING 5000 PSI WITH .40 WATER-CEMENT RATIO SHALLOW FOUNDATIONS 2500 PSI. PILE SUPPORTED FOUNDATIONS 5000 PSI WITH .40 WATER-CEMENT RATIO COLUMNS, BEAMS, AND ELEVATED SLABS, 3000 PSI. CONCRETE SLUMP SHALL BE AS FOLLOWS SLUMP IN INCHES MINMAX MASSIVE SECTIONS, PAVEMENTS, AND SLABS1-1/2" 4" HEAVY SLABS, BEAMS, WALLS 3" 5" THIN WALLS, COLUMNS3-1/2" 6" MINIMUM CONCRETE CLEAR COVER SHALL BE: SLAB - 3/4" BEAMS AND COLUMNS – 1-1/2" TIE COLUMNS - 3/4" EXPOSED UNPROTECTED CONCRETE – 1-1/2" FORMED CONCRETE BELOW GRADE - 3" UNFORMED CONCRETE BELOW GRADE - 3" PLACING DRAWINGS AND BAR LISTS SHALL CONFORM TO A.C.I.'S "MANUAL OF STANDARD PRACTICE FOR DETAILING REINFORCED CONCRETE STRUCTURES."(A.C.I. 315) DETAILS OF CONCRETE REINFORCEMENT SHALL BE IN ACCORDANCE WITH "MANUAL OF STANDARD PRACTICE FOR REINFORCED CONCRETE CONSTRUCTION." AS PUBLISHED BY THE CONCRETE REINFORCING STEEL INSTITUTE UNLESS OTHERWISE INDICATED. CONCRETE CONSTRUCTION TECHNIQUES SHALL CONFORM TO THE "SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BUILDINGS" (A.C.I. 301) ADEQUATE VERTICAL AND HORIZONTAL SHORING SHALL BE PROVIDED TO SAFELY SUPPORT ALL CONSTRUCTION LOADS CONCRETE BEAM SIZES MAY BE INCREASED AS REQUIRED FOR ARCHITECTURAL DETAILS OR TO FIT BLOCK COURSING. CONCRETE SHALL COMPLY WITH ALL THE REQUIREMENTS OF A.C.I 301 AND ASTM C-94 FOR MEASURING, MIXING, TRANSPORTING, ETC. CALCIUM CHLORIDES SHALL NOT BE UTILIZED IN THE WORK. OTHER ADMIXTURES MAY BE USED ONLY WITH THE APPROVAL OF THE ENGINEER. FBC PROVIDES AN EXCEPTION FOR RESIDENTIAL CONSTRUCTION WHERE CONTROL JOINTS ARE NOT REQUIRED. HOWEVER, IN THAT EXCEPTION, IT SAYS THAT THE EXCEPTION IS ALLOWED WHERE THE OWNER ACKNOWLEDGES THAT CRACKS ARE ACCEPTABLE AND UNDERSTOOD. 1. JOB SPECIFIC GENERAL NOTES: HOUSE IS IN A NEGLIGIBLE WEATHER AREA 2. HOUSE IS IN A VERY HEAVY TERMITE AREA. 3. FLAME SPREAD FOR WALLS AND CEILING FINISHES SHALL BE LESS THAN 200. 4. FLAME SPREAD FOR INSULATION SHALL BE LESS THAN 25 5. SMOKE DEVELOPED INDEX SHALL BE LESS THE 450 FOR WALL FINISHES, CEILING FINISH AND INSULATION 6. GYPSUM BOARD SHALL CONFORM TO FBC R702.3 STANDARDS 7. TILE IN SHOWERS MUST BE BACKED BY "DURA ROCK" CONCRETE BOARD OR EQUAL 8. EGRESS WINDOWS COMPLY WITH 2020 FBCR 7TH EDITION R310.2.1 EXCEPTION #1 MIN. NET CLEAR OPENING OF 5.0 S.F. 9. DRYER VENT TO OUTSIDE 10. LOW FLOW PLUMBING FIXTURES MASONARY NOTES: STRUCTURAL DESIGN IS IN ACCORDANCE WITH A.C.1530-05/ASCE 5-02/TMS 402-02, BUILDING CODE REQUIREMENTS FOR MASONRY STRUCTURES AND THE COMMENTARY ON BUILDING CODE REQUIREMENTS FOR MASONRY STRUCTURES. CONSTRUCTION SHALL BE IN ACCORDANCE WITH A.C.1530-05/ASCE 6-02/TMS 602-02, SPECIFICATIONS FOR MASONRY STRUCTURES AND THE COMMENTARY ON SPECIFICATIONS FOR MASONRY STRUCTURES. ALL BLOCK WALLS SHALL BE TWO CELL HOLLOW CONCRETE MASONRY REGULAR SIZE BLOCK MANUFACTURED IN CONFORMANCE WITH ASTM C-90, GRADE, F'm=1500 P.S.I. UNLESS OTHERWISE NOTED. BLOCK SHALL BE PLACED IN RUNNING BOND UNLESS OTHERWISE NOTED. LAY UP MASONRY WALLS TO BOTTOM OF TIE BEAMS BEFORE PLACING CONCRETE FOR IN WALL COLUMNS. GROUT USED TO FILL MASONRY CELLS SHALL COMPLY WITH ASTM C-476 AND SHALL PROVIDE A MINIMUM COMPRESSIVE STRENGTH OF 3,000 P.S.I AT 28 DAYS. THE GROUT MIX SHALL HAVE A MAXIMUM 3/8" COURSE AGGREGATE AND SHALL BE PLACED WITH A SLUMP OF 8" TO 10". USE MECHANICAL VIBRATION TO CONSOLIDATE GROUT. TYPE S MORTAR SHALL BE USED EXCLUSIVELY ON THIS PROJECT. MORTAR SHALL BE PROPORTIONED AND MIXED AS OUTLINED UNDER ASTM C-270 HORIZONTAL AND VERTICAL MORTAR JOINTS SHALL BE 3/8" THICK UNLESS OTHERWISE NOTED. REMOVE MORTAR PROTRUSIONS THAT EXTEND INTO THE CELLS TO BE FILLED. ALLOW A MINIMUM OF 24 HOURS FOR MORTAR TO CURE PRIOR TO GROUTING CELLS. TENSION AND COMPRESSION LAPS = .002 X BAR DIAMETER X Fs (NOTE THAT Fs= 24 KSI MAXIMUM (.4 X Fy)) (THIS EQUATES TO 48 X BAR DIAMETER) REINFORCING BAR SHALL BE IN ALL WALL INTERSECTIONS AND AT EACH SIDE OF ALL OPENINGS. POURED DOWNCELL TO BE AT EVERY GIRDER LOCATION AND REINFORCING BARS SHALL BE AT ALL DBL. GIRDER TRUSSES Rev. # DescriptionDateSITE PREPARATION: THE PROPOSED BUILDING AREA AND AREAS TO BE PAVED, PLUS A MINIMUM MARGIN OF FIVE FEET BEYOND THE PROPOSED CONSTRUCTION SHALL BE STRIPPED AND GRUBBED OF SURFACE DEBRIS, INCLUDING VEGETATION, ROOTS AND ORGANIC MATTER. STUMPS SHALL BE REMOVED ENTIRELY. THE BUILDING AREA SHOULD BE GRADED LEVEL AND PROOFROLLED. ANY SOFT YIELDING AREAS SHALL BE EXCAVATED AND REPLACED WITH CLEAN COMPACTED FILL. SUFFICIENT PASSES SHOULD BE MADE DURING COMPACTION OPERATIONS TO PRODUCE A DENSITY NO LESS THAN 95 PERCENT OF ITS MODIFIED DRY PROCTOR VALUE (ASTM D 1557) TO A DEPTH OF TWO FEET. AFTER THE EXPOSED SURFACE HAS BEEN PROOFROLLED, THE BUILDING AND PAVEMENT AREAS MAY BE FILLED TO THE DESIRED GRADES. THE FILL MATERIAL SHALL CONSIST OF CLEAN GRANULAR SAND CONTAINING LESS THAN 10% MATERIAL PASSING THE U.S. STANDARD NO. 200 MESH SIEVE. PLACE STRUCTURAL FILL IN LOOSE LAYERS OF 12 INCHES IN THICKNESS AND COMPACT EACH LIFT TO AT LEAST 95 PERCENT OF ITS MODIFIED DRY PROCTOR VALUE. AFTER EXCAVATING FOR THE FOOTINGS, THE DISTURBED FOOTING SUBGRADE SHOULD BE RECOMPACTED TO 95 PERCENT (MINIMUM) OF ITS MODIFIED DRY PROCTOR VALUE. THIS CAN BE BEST ACHIEVED BY MAKING SEVERAL PASSES WITH A RELATIVELY LIGHT-WEIGHT WALK-BEHIND VIBRATORY SLED OR ROLLER. TIMBER NOTES: ALL WOOD MEMBERS HAVE BEEN DESIGNED IN ACCORDANCE WITH THE NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION AND IT'S SUPPLEMENT, (NDS) ALL WOOD FOR BEAMS, BEARING WALLS, SOLE PLATES, TOP PLATES, BLOCKING, BRACING, LEDGERS, CRIPPLES, SILLS, ETC... SHALL BE SOUTHERN PINE NO. 2, KD-15 OR BETTER. MIN (3) 2"x UNDER ALL GIRDER BEARING LOCATIONS. SEE FLOOR PLAN MICRO LAM BEAMS SHALL BE MANUFACTURED BY TRUS-JOIST CORP., OR AND APPROVED EQUIVALENT AND SHALL PROVIDE A MODULUS OF ELASTICITY OF 2,000,000 PSI, A MINIMUM FLEXURAL STRENGTH OF 2,925 PSI, AND A MINIMUM HORIZONTAL SHEAR STRESS OF 285 PSI. ALL WOOD IN CONTACT WITH CONCRETE OR CONCRETE BLOCK SHALL NE PRESSURE TREATED. ACCEPTABLE TREATMENTS INCLUDE ACQ. (AMINE COPPER QUAT) COPPER BORON AZOLE, ACID COPPER CHROMATE, AND COPPER CITRATE. BORATE BASED TREATMENTS SUCH AS ZINCBORATE AND SODIUM BORATE ARE ALSO ACCEPTABLE FOR INDOOR USES. FOR STRUCTURAL USES, AVOID BUYING TREATED LUMBER THAT CONTAINS MORE THE 1/2" OF HEARTWOOD AVOID INHALATION OF SAWDUST PRODUCED BY PRESSURE TREATED WOOD, WEAR A DUST MASK AND WORK OUTDOORS. DISPOSE OF DUST AND SCRAP BY ORDINARY TRASH COLLECTION. DO NOT BURN. PRESSURE TREATED WOOD MAY PRODUCE TOXIC FUMES. IN HIGHLY CORROSIVE ENVIRONMENTS ALL WIND RESISTING HARDWARE INCLUDING THE HURRICANE STRAPS SHALL BE MADE OF STAINLESS STEEL OR SHALL BE DIPPED (AND SCRATCHES REPAINTED) IN COL-TAR EPOXY PAINT. HURRICANE STRAPS SHALL BE INSTALLED ACCORDING TO MANUFACTURER'S INSTRUCTIONS. HANGERS OR STRAPS THAT DO NOT MATCH EXACTLY TO THE ONES SPECIFIED ON THE DRAWINGS IN STEEL YIELD OR ULTIMATE STRENGTH, STEEL DIMENSIONS (LENGTH AND WIDTH), NUMBER AND DIAMETER OF HOLES FOR SAME SIZES OF NAILS OR BOLTS, AND/OR DO NOT HAVE THE SAME GENERAL SHAPE WILL NOT BE ACCEPTABLE. NO POCKETS WILL BE ALLOWED IN CONCRETE OR STEEL MEMBERS FOR CONNECTION OF WOOD MEMBERS UNLESS CONNECTION DETAIL IS IN WRITING PRIOR TO INSTALLATION. ALL NAILS, SCREWS, AND BOLTS SHALL BE HOT-DIPPED GALVANIZED. I HEREBY CERTIFY AS THE BUILDING DESIGN ENGINEER OF RECORD, THAT THE BUILDING DESIGN AS SHOWN ON THESE PLANS (STRUCTURAL COMPLIANCE ONLY) AND AS ACCOMPANIED BY DESIGN AND SUPPORT DOCUMENTS, CONFORMS TO THE 2020 7th EDITION FLORIDA BUILDING CODE. THIS CERTIFICATION DOES NOT INCLUDE ROOF TRUSS COMPONENTS OF WHICH THE TRUSS DESIGN ENGINEER IS THE ENGINEER OF RECORD. THESE PLANS HAVE BEEN PREPARED IN COMPLIANCE WITH THE 2020 7th EDITION FLORIDA BUILDING CODE WITH SUPPLEMENTS. Craig E. Gunderson, P.E. #060102 Date: FLORIDA ENGINEERING, LLC 4161 TAMIAMI TRAIL, UNIT 101 PORT CHARLOTTE, FL. 33952 PH: (941) 391-5980 FAX: (941) 979-8196 FRIDGE CEILING HEIGHT 10' 1" COFFER TO 11' 1" WH CEILING HEIGHT 10' 1" COFFER TO 11' 1" 15' - 3" x 14' - 0" MASTER BEDROOM WIC WIC 17' - 6" x 9' - 5" MASTER BATH DEN 8' - 3" x 7' - 8" FOYER 27' - 2" x 13' - 1" GREAT ROOM KITCHEN 8' - 8" x 4' - 6" BUTLER'S PANTRY 9' - 0" x 8' - 6" LAUNDRY BEDROOM 2 BATH 2 BEDROOM 3 BATH 3 FLEX SPACE CASUAL DINING GARAGE FT. ENTRY 10' - 8" X 12' - 1" CEILING HEIGHT 15' - 7" LANAI 15' - 9" X 14' - 4" CEILING HEIGHT 10' - 1" DINING PATIO 16' - 10" X 12' - 8" CEILING HEIGHT 10' - 1" 30' - 8" X 20' - 6" CEILING HEIGHT 10' - 1" 13' - 2" X 12' - 6" CEILING HEIGHT 10' - 1" 13' - 2" X 13' - 0" CEILING HEIGHT 10' - 1" 13' - 0" X 15' - 10" CEILING HEIGHT 10' - 1" 16' - 4" X 10' - 0" 13' - 6" X 19' - 0" CEILING HEIGHT 10' - 1" 11' - 0" X 11' - 0" CEILING HEIGHT 12' - 1" CEILING 12' 1" COFFER TO 13' 1" CEILING HEIGHT 10' - 1" MASTER SHOWER OPTIONAL GRILL AREA LINEAR NICHE SEATDW ARRIVAL CENTER SUSPENDED AIR HANDLER OPTIONAL CLOSET CEILING HEIGHT 10' 1" COFFER TO 11' 1" ACTIVE FIXED Linen Closet 24 x 20 x 84IRONING BOARD Linen Closet 24 x 22 x 84 ATTIC ACCESS WITH LADDER VERIFY LOCATION ON SITEP.C.WASHERDRYERScaleVILLADELTA CONSTRUCTION CORP. LLC CRC 058035THE DESIGN PROFESSIONAL OF RECORD (ENGINEER AND/OR ARCHITECT) ASSUMES ALL RESPONSIBILITY OF THE SPECIFICATIONS CONTAINED HERE IN. IT IS THE CLIENT'S AND/OR CONTRACTOR'S RESPONSIBILITY TO VERIFY THE FINAL PLANS AND MEASUREMENTS. ALL CHANGES FROM THIS POINT FORWARD WILL NEED A SIGNED CHANGE ORDER BEFORE ANY ADDITIONAL WORK OR MODIFICATIONS WILL BE MADE. ALL WRITTEN CHANGE ORDERS SUPERCEED THE DRAWINGS. THE DRAWINGS ARE CONCEPTUAL DESIGNS AND MAY VARY FROM THE FINISHED PROUCT. THESE DRAWINGS ARE THE PROPERTY OF THE DISIGNER AND SHALL NOT BE REPRODUCED, MODIFIED OR ALTERED WITHOUT PRIOR WRITTEN CONSENT. THESE DRAWINGS WILL REMAIN THE PROPERTY OF THE DESIGNER EVEN IF THEY ARE NOT USED IN THE CONSTRUCTION OF THIS PROJECT. COPYRIGHTT 2016 PRONTO PLANS, L.L.C. ___________________________________CLIENT'S APPROVAL DATE 1/4" = 1'-0" 11/24/2021 12:48:31 AM A-22401 Noble Oaks LaneFt. Pierce, FL 34981Dudley Residence 1/4" = 1'-0"1First Floor Area Calculations Name Area LIVING 2833 SF GARAGE 653 SF LANAI 223 SF DINING PATIO 203 SF FT. PORCH 104 SF Grand total: 5 4015 SF Rev. # DescriptionDateI HEREBY CERTIFY AS THE BUILDING DESIGN ENGINEER OF RECORD, THAT THE BUILDING DESIGN AS SHOWN ON THESE PLANS (STRUCTURAL COMPLIANCE ONLY) AND AS ACCOMPANIED BY DESIGN AND SUPPORT DOCUMENTS, CONFORMS TO THE 2020 7th EDITION FLORIDA BUILDING CODE. THIS CERTIFICATION DOES NOT INCLUDE ROOF TRUSS COMPONENTS OF WHICH THE TRUSS DESIGN ENGINEER IS THE ENGINEER OF RECORD. THESE PLANS HAVE BEEN PREPARED IN COMPLIANCE WITH THE 2020 7th EDITION FLORIDA BUILDING CODE WITH SUPPLEMENTS. Craig E. Gunderson, P.E. #060102 Date: FLORIDA ENGINEERING, LLC 4161 TAMIAMI TRAIL, UNIT 101 PORT CHARLOTTE, FL. 33952 PH: (941) 391-5980 FAX: (941) 979-8196 First Floor0"First Floor0" Entry Roof15' - 7" Main Roof10' - 1" Elevated Front12' - 1"2' - 2 1/2"2' - 1 3/4"5' - 8 3/4"10' - 11 3/4"5" / 12"5" / 12"5" / 12"1 2 1' - 8" 1' - 8" 1' - 8"20' - 3 7/8"20' - 11 3/4"19' - 2 3/4"15' - 1 7/8"1' - 10 1/4"8' - 2 3/4"2' - 0"2' - 0 1/2"5' - 1 1/2"2' - 0 1/2"6' - 1 3/4"2' - 0"2' - 7"3' - 2" CA 2660 2 PW 6020 1 6080 FD 1 CA 2660-2 22 CA 2660-2 20 PW 2620-2 21PW 2620-2 23 PW 2020 19 CA 2020 18 PW 2020 178080 GD 3 16080 GD 2 7' - 10 1/2" 10' - 2 3/4" 8' - 1 3/4"6"8' - 0"1' - 2"2' - 6"10"11' - 5"5' - 8 3/4" 6" 10' - 3 3/4" First Floor0"First Floor0" Main Roof10' - 1"Main Roof10' - 1" 9' - 0 1/4"3' - 11"2' - 9 1/4"5' - 4 3/4" 1' - 11" SH35 EGRESS 13 SH35 EGRESS 11 SH25 EGRESS 9 2' - 9 1/4"5' - 4 3/4" 1' - 11"2' - 9 1/4"5' - 4 3/4" 1' - 11" 125" / 12"5" / 12"5" / 12"1' - 8" 1' - 8" 1' - 8"1' - 8" SH35 EGRESS 12 SH35 EGRESS 10 SH25 EGRESS 8 4' - 5 1/8"6' - 4"9' - 0 1/4" 1' - 4"3' - 6" 8' - 2" 8' - 2"8' - 2"8' - 1 1/2"8' - 2"2' - 3"3080 Panel 412080 SLIDER 7 2880 FD 5 5" / 12"9' - 5"1' - 0"ScaleVILLADELTA CONSTRUCTION CORP. LLC CRC 058035THE DESIGN PROFESSIONAL OF RECORD (ENGINEER AND/OR ARCHITECT) ASSUMES ALL RESPONSIBILITY OF THE SPECIFICATIONS CONTAINED HERE IN. IT IS THE CLIENT'S AND/OR CONTRACTOR'S RESPONSIBILITY TO VERIFY THE FINAL PLANS AND MEASUREMENTS. ALL CHANGES FROM THIS POINT FORWARD WILL NEED A SIGNED CHANGE ORDER BEFORE ANY ADDITIONAL WORK OR MODIFICATIONS WILL BE MADE. ALL WRITTEN CHANGE ORDERS SUPERCEED THE DRAWINGS. THE DRAWINGS ARE CONCEPTUAL DESIGNS AND MAY VARY FROM THE FINISHED PROUCT. THESE DRAWINGS ARE THE PROPERTY OF THE DISIGNER AND SHALL NOT BE REPRODUCED, MODIFIED OR ALTERED WITHOUT PRIOR WRITTEN CONSENT. THESE DRAWINGS WILL REMAIN THE PROPERTY OF THE DESIGNER EVEN IF THEY ARE NOT USED IN THE CONSTRUCTION OF THIS PROJECT. COPYRIGHTT 2016 PRONTO PLANS, L.L.C. ___________________________________CLIENT'S APPROVAL DATE 1/4" = 1'-0" 11/24/2021 12:48:34 AM A-32401 Noble Oaks LaneFt. Pierce, FL 34981Dudley Residence 1/4" = 1'-0"1Front 1/4" = 1'-0"2Rear Rev. # DescriptionDateI HEREBY CERTIFY AS THE BUILDING DESIGN ENGINEER OF RECORD, THAT THE BUILDING DESIGN AS SHOWN ON THESE PLANS (STRUCTURAL COMPLIANCE ONLY) AND AS ACCOMPANIED BY DESIGN AND SUPPORT DOCUMENTS, CONFORMS TO THE 2020 7th EDITION FLORIDA BUILDING CODE. THIS CERTIFICATION DOES NOT INCLUDE ROOF TRUSS COMPONENTS OF WHICH THE TRUSS DESIGN ENGINEER IS THE ENGINEER OF RECORD. THESE PLANS HAVE BEEN PREPARED IN COMPLIANCE WITH THE 2020 7th EDITION FLORIDA BUILDING CODE WITH SUPPLEMENTS. Craig E. Gunderson, P.E. #060102 Date: FLORIDA ENGINEERING, LLC 4161 TAMIAMI TRAIL, UNIT 101 PORT CHARLOTTE, FL. 33952 PH: (941) 391-5980 FAX: (941) 979-8196 First Floor0"First Floor0" Entry Roof15' - 7" Main Roof10' - 1"Main Roof10' - 1" Elevated Front12' - 1" SH25 EGRESS 4 SH 2833 OBSCURE 5SH25 EGRESS 6 SH23 TEMP OBSCURE 7 1' - 11"5' - 4 3/4"2' - 9 1/4"1' - 11"3' - 4 1/8"4' - 9 7/8"1' - 11"5' - 4 3/4"2' - 9 1/4"1' - 11"3' - 4 1/8"4' - 9 7/8"18' - 1 1/8"3' - 2" 2' - 0" 3' - 2"13' - 2"2' - 9"2' - 2"3' - 2"8' - 5 1/2" B A5" / 12"5" / 12"5" / 12"1' - 8"1' - 8"1' - 8 1/8" 8' - 2" First Floor0"First Floor0" Entry Roof15' - 7" Main Roof10' - 1"Main Roof10' - 1" Elevated Front 12' - 1" PW 5050 OBSCURE 31' - 11"5' - 1 3/4"3' - 4 1/4"PW 1960 16 PW 1960 15 SH14 TEMP OBSCURE 141' - 11"6' - 1 3/4"2' - 0 1/4"5' - 11 1/2"1' - 10" 5' - 11 3/4" 1' - 10" 3' - 10 1/2" 1' - 8 1/8"3' - 9 5/8"4' - 4 3/8" 1' - 11" BA5" / 12"5" / 12"5" / 12"7' - 9 7/8" 8' - 1 1/2"8' - 1 1/2" 8' - 2" 8' - 2" 6080 SLIDER XX 6 2880 FD 5 1' - 0"9' - 5"5" / 12"5" / 12"ScaleVILLADELTA CONSTRUCTION CORP. LLC CRC 058035THE DESIGN PROFESSIONAL OF RECORD (ENGINEER AND/OR ARCHITECT) ASSUMES ALL RESPONSIBILITY OF THE SPECIFICATIONS CONTAINED HERE IN. IT IS THE CLIENT'S AND/OR CONTRACTOR'S RESPONSIBILITY TO VERIFY THE FINAL PLANS AND MEASUREMENTS. ALL CHANGES FROM THIS POINT FORWARD WILL NEED A SIGNED CHANGE ORDER BEFORE ANY ADDITIONAL WORK OR MODIFICATIONS WILL BE MADE. ALL WRITTEN CHANGE ORDERS SUPERCEED THE DRAWINGS. THE DRAWINGS ARE CONCEPTUAL DESIGNS AND MAY VARY FROM THE FINISHED PROUCT. THESE DRAWINGS ARE THE PROPERTY OF THE DISIGNER AND SHALL NOT BE REPRODUCED, MODIFIED OR ALTERED WITHOUT PRIOR WRITTEN CONSENT. THESE DRAWINGS WILL REMAIN THE PROPERTY OF THE DESIGNER EVEN IF THEY ARE NOT USED IN THE CONSTRUCTION OF THIS PROJECT. COPYRIGHTT 2016 PRONTO PLANS, L.L.C. ___________________________________CLIENT'S APPROVAL DATE 1/4" = 1'-0" 11/24/2021 12:48:37 AM A-42401 Noble Oaks LaneFt. Pierce, FL 34981Dudley Residence 1/4" = 1'-0"1Left 1/4" = 1'-0"2Right Rev. # DescriptionDateI HEREBY CERTIFY AS THE BUILDING DESIGN ENGINEER OF RECORD, THAT THE BUILDING DESIGN AS SHOWN ON THESE PLANS (STRUCTURAL COMPLIANCE ONLY) AND AS ACCOMPANIED BY DESIGN AND SUPPORT DOCUMENTS, CONFORMS TO THE 2020 7th EDITION FLORIDA BUILDING CODE. THIS CERTIFICATION DOES NOT INCLUDE ROOF TRUSS COMPONENTS OF WHICH THE TRUSS DESIGN ENGINEER IS THE ENGINEER OF RECORD. THESE PLANS HAVE BEEN PREPARED IN COMPLIANCE WITH THE 2020 7th EDITION FLORIDA BUILDING CODE WITH SUPPLEMENTS. Craig E. Gunderson, P.E. #060102 Date: FLORIDA ENGINEERING, LLC 4161 TAMIAMI TRAIL, UNIT 101 PORT CHARLOTTE, FL. 33952 PH: (941) 391-5980 FAX: (941) 979-8196 ScaleVILLADELTA CONSTRUCTION CORP. LLC CRC 058035THE DESIGN PROFESSIONAL OF RECORD (ENGINEER AND/OR ARCHITECT) ASSUMES ALL RESPONSIBILITY OF THE SPECIFICATIONS CONTAINED HERE IN. IT IS THE CLIENT'S AND/OR CONTRACTOR'S RESPONSIBILITY TO VERIFY THE FINAL PLANS AND MEASUREMENTS. ALL CHANGES FROM THIS POINT FORWARD WILL NEED A SIGNED CHANGE ORDER BEFORE ANY ADDITIONAL WORK OR MODIFICATIONS WILL BE MADE. ALL WRITTEN CHANGE ORDERS SUPERCEED THE DRAWINGS. THE DRAWINGS ARE CONCEPTUAL DESIGNS AND MAY VARY FROM THE FINISHED PROUCT. THESE DRAWINGS ARE THE PROPERTY OF THE DISIGNER AND SHALL NOT BE REPRODUCED, MODIFIED OR ALTERED WITHOUT PRIOR WRITTEN CONSENT. THESE DRAWINGS WILL REMAIN THE PROPERTY OF THE DESIGNER EVEN IF THEY ARE NOT USED IN THE CONSTRUCTION OF THIS PROJECT. COPYRIGHTT 2016 PRONTO PLANS, L.L.C. ___________________________________CLIENT'S APPROVAL DATE 11/24/2021 12:48:38 AM A-52401 Noble Oaks LaneFt. Pierce, FL 34981Dudley ResidenceDoor Schedule - Exterior Mark Count Manufacturer Model Type Width Head Height Swing Glass Type 1 1PGT Industries FD101 6080 FD 6' - 0" 8' - 0" LH ACTIVE Glass - Clear - PGT Low E MAX Insulated 2 1Wayne Dalton SERIES 8000 16080 GD 16' - 0" 7' - 8" SECTIONAL 3 1Wayne Dalton SERIES 8000 8080 GD 8' - 0" 7' - 8" SECTIONAL 4 1THERMA-TRU Fiber Classic 3080 Panel 3' - 0" 7' - 8" RHOS 5 1PGT Industries FD101 2880 FD 2' - 8" 8' - 0" RHOS Glass - Clear - PGT Low E MAX Insulated 6 1PGT Industries SGD770 6080 SLIDER XX 6' - 0" 8' - 0" RH ACTIVE Glass - Clear - PGT Low E MAX Insulated 7 1PGT Industries SGD770 12080 SLIDER 12' - 0" 8' - 0" LH ACTIVE Glass - Clear - PGT Low E MAX Insulated Grand total: 7 Window Schedule Mark Count Manufacturer Model Type Width HeightColor Glass 11 PGT WinGuard PW7720A PW 6020 6' - 5" 2' - 0" Glass - Clear - PGT Low E MAX Insulated 21 PGT WinGuard CA740 CA 2660 2' - 6" 6' - 0" Glass - Clear - PGT Low E MAX Insulated 31 PGT WinGuard PW7720A PW 5050 OBSCURE 5' - 0" 5' - 0" Glass - Low E MAX - PGT - Obscure Insulated Temp. 41 PGT Industries SH7700A SH25 EGRESS 3' - 1" 5' - 3" Glass - Clear - PGT Low E MAX Insulated 51 PGT Industries SH7700A SH 2833 OBSCURE 2' - 8" 3' - 2 3/8" Glass - Low E MAX - PGT - Obscure Insulated Temp. 61 PGT Industries SH7700A SH25 EGRESS 3' - 1" 5' - 3" Glass - Clear - PGT Low E MAX Insulated 71 PGT Industries SH7700A SH23 TEMP OBSCURE 3' - 1" 3' - 2 3/8" Glass - Low E MAX - PGT - Obscure Insulated Temp. 81 PGT Industries SH7700A SH25 EGRESS 3' - 1" 5' - 3" Glass - Clear - PGT Low E MAX Insulated 91 PGT Industries SH7700A SH25 EGRESS 3' - 1" 5' - 3" Glass - Clear - PGT Low E MAX Insulated 101 PGT Industries SH7700A SH35 EGRESS 4' - 5 1/8" 5' - 3" Glass - Clear - PGT Low E MAX Insulated 111 PGT Industries SH7700A SH35 EGRESS 4' - 5 1/8" 5' - 3" Glass - Clear - PGT Low E MAX Insulated 121 PGT Industries SH7700A SH35 EGRESS 4' - 5 1/8" 5' - 3" Glass - Clear - PGT Low E MAX Insulated 131 PGT Industries SH7700A SH35 EGRESS 4' - 5 1/8" 5' - 3" Glass - Clear - PGT Low E MAX Insulated 141 PGT Industries SH7700A SH14 TEMP OBSCURE 1' - 7 1/8" 4' - 2 5/8" Glass - Low E MAX - PGT - Obscure Insulated Temp. 151 PGT Industries PW7720A PW 1960 1' - 9" 6' - 0" Glass - Loe E MAX - PGT - Obscure Insulated Temp. 161 PGT Industries PW7720A PW 1960 1' - 9" 6' - 0" Glass - Loe E MAX - PGT - Obscure Insulated Temp. 171 PGT WinGuard PW7720A PW 2020 2' - 0" 2' - 0" Glass - Clear - PGT Low E MAX Insulated 181 PGT WinGuard CA740 CA 2020 2' - 0" 2' - 0" Glass - Clear - PGT Low E MAX Insulated 191 PGT WinGuard PW7720A PW 2020 2' - 0" 2' - 0" Glass - Clear - PGT Low E MAX Insulated 201 PGT WinGuard CA740 CA 2660-2 2' - 6" 6' - 0" Glass - Clear - PGT Low E MAX Insulated 211 PGT WinGuard PW7720A PW 2620-2 2' - 6" 1' - 11 1/4" Glass - Clear - PGT Low E MAX Insulated 221 PGT WinGuard CA740 CA 2660-2 2' - 6" 6' - 0" Glass - Clear - PGT Low E MAX Insulated 231 PGT WinGuard PW7720A PW 2620-2 2' - 6" 1' - 11 1/4" Glass - Clear - PGT Low E MAX Insulated Grand total: 23 Rev. # DescriptionDateDoor Schedule - Interior MarkManufacturer Model Swing Width Height 40THERMA-TRU Fire Rated 20MIN LHIS 3' - 0" 8' - 0" 41Masonite Solid Core Pocket 3' - 0" 8' - 0" 42Masonite Solid Core BiFold 3' - 0" 8' - 0" 43Masonite Solid Core RH 2' - 8" 8' - 0" 44Masonite Solid Core BiFold 6' - 0" 8' - 0" 45Masonite Solid Core Pocket 2' - 8" 8' - 0" 46Masonite Solid Core LH 2' - 6" 8' - 0" 47Masonite Solid Core RH 2' - 6" 8' - 0" 48Masonite Solid Core BiFold 5' - 0" 8' - 0" 49Masonite Solid Core BiFold 5' - 0" 8' - 0" 50Masonite Solid Core LH 2' - 8" 8' - 0" 51Masonite Solid Core LH 2' - 8" 8' - 0" 52Masonite Solid Core BiFold 6' - 0" 8' - 0" 53Masonite Solid Core LH 2' - 8" 8' - 0" 54Masonite Solid Core LH 2' - 6" 8' - 0" 55Masonite Solid Core RH 3' - 0" 8' - 0" 56Masonite Solid Core BiFold 5' - 0" 8' - 0" 57Masonite Solid Core RH 3' - 0" 8' - 0" 58Masonite Solid Core Pocket 3' - 0" 8' - 0" 59Masonite Solid Core RH 2' - 6" 8' - 0" 60Masonite Solid Core LH 2' - 6" 8' - 0" Grand total: 21 I HEREBY CERTIFY AS THE BUILDING DESIGN ENGINEER OF RECORD, THAT THE BUILDING DESIGN AS SHOWN ON THESE PLANS (STRUCTURAL COMPLIANCE ONLY) AND AS ACCOMPANIED BY DESIGN AND SUPPORT DOCUMENTS, CONFORMS TO THE 2020 7th EDITION FLORIDA BUILDING CODE. THIS CERTIFICATION DOES NOT INCLUDE ROOF TRUSS COMPONENTS OF WHICH THE TRUSS DESIGN ENGINEER IS THE ENGINEER OF RECORD. THESE PLANS HAVE BEEN PREPARED IN COMPLIANCE WITH THE 2020 7th EDITION FLORIDA BUILDING CODE WITH SUPPLEMENTS. Craig E. Gunderson, P.E. #060102 Date: FLORIDA ENGINEERING, LLC 4161 TAMIAMI TRAIL, UNIT 101 PORT CHARLOTTE, FL. 33952 PH: (941) 391-5980 FAX: (941) 979-8196 F1F5F2F3F1F1F1F1F1F1F3S-1216' - 11 5/8"5' - 5"1122BBAA12' - 0"20' - 0"29' - 10 1/2"10' - 11 3/4"20' - 8 5/8"11' - 1"7' - 5"11' - 4 1/2"8' - 9"48' - 0 3/8"9' - 10 3/4"8' - 0 1/4"77' - 10 7/8"56' - 1 3/4"19' - 3 1/4"2' - 5 7/8"15' - 2 1/4"16' - 3 1/2"15' - 9 1/8"16' - 2 5/8"72' - 10 1/4"9' - 4 3/4"63' - 5 1/2"65' - 11 1/4"11' - 11 5/8"4" 3000# FIBERMIX CONCRETE ON .006 VAPOR BARRIER ON CLEAN, COMPACTED, TERMITE TREATED FILLFILL TO COMPLY WITH SITE PREPARATION ON PAGE "A-2" ALL PERIMETER & INTERIOR FOOTINGS TO BE 16" WIDE X 20" DEEP WITH (2) #5 REBAR CONTINUOUS UNLESS OTHERWISE NOTEDUNLESS OTHERWISE NOTED ON PLANVERT.STEEL PLACEMENT NOT TO EXCEED:4'-0" O.C. IN 10'-1" WALLS &3'-0" O.C. IN 12'-1" WALLS"TIE BEAM POUR DOWN OVER WINDOWS & DOORS:FOR EACH ADDITIONAL 12" ADD (2)#5 REBAR HORIZ.MAX. BEAM DEPTH 48"CONTRACTOR TO VERIFY ALL MASONRY OPENINGS IN THE FIELD2' - 6 1/4"2' - 10 1/8" 2' - 9 1/8"WINDOW3' - 10" 1' - 6"WINDOW3' - 5" 4' - 2"4' - 2"4' - 2"WINDOW3' - 10" 8" 8"WINDOW3' - 10" 3' - 5 7/8" 3' - 5 7/8" 3' - 5 7/8" 3' - 5 7/8" 3' - 9 7/8"4' - 1 1/8"WINDOW7' - 0"4' - 1 1/8"15' - 3 1/2"1' - 0"3' - 3 5/8"2' - 11 5/8"3' - 6 3/4"DOOR3' - 10 1/4"1' - 4 3/4"WINDOW9' - 8 1/4"2' - 4 7/8"1' - 9 7/8"SLIDER6' - 10"8"4"1' - 0"SLIDER12' - 10"1' - 3 1/2"3' - 7"WINDOW9' - 8 1/4"3' - 7"1' - 0"6' - 8 1/4"4"4"14' - 5 1/8"1' - 0"1' - 0"8' - 10 3/4"4' - 5 1/8"4' - 0 7/8"3' - 8 7/8"3' - 8 7/8"3' - 8 7/8"3' - 8 7/8"3' - 8 7/8"3' - 8 7/8"WINDOW2' - 4 1/8"3' - 2 1/2"WINDOW2' - 6"4' - 7 3/4"8"WINDOW2' - 6"2' - 7 3/4"2' - 11 3/4"11 7/8"WINDOW2' - 9" 4"WINDOW2' - 10" 4"WINDOW2' - 9" 11 7/8"3' - 3"2' - 11" 2' - 7"1' - 10"2' - 0"WINDOW5' - 11" 1' - 7 1/2"2' - 9 1/2"WINDOW3' - 4" 3' - 1 1/2"1' - 10"3' - 10 3/4"3' - 7 1/8"WINDOW5' - 9"3' - 11 1/8" 3' - 6 5/8"1' - 0"8"GARAGE DOOR16' - 8"8"1' - 0"1' - 0"8"GARAGE DOOR8' - 8"8"1' - 0"4' - 0 1/2"3' - 8 5/8"3' - 8 5/8"3' - 8 5/8"4' - 0 3/4"1' - 0"DOOR4' - 2" 2' - 1" 2' - 1 3/4"-4" SLOPE 1.50"-4" SLOPE 2.00"-4" SLOPE 1.75"ASSUME 0.00" FFE20' - 7"1' - 6"16' - 10 1/4"9' - 7 7/8"15' - 1 1/2"S-139' - 10 1/2"13' - 5 3/4"22' - 2 5/8"4 1/2"14' - 0 3/4"9' - 6"KITCHEN ISLAND WALL7 5/8"3' - 2"RECESS 2" FOR SLIDER 12' - 2"9"9"6' - 2"RECESS 2" FOR SLIDER -4"-4"8"OPENING13' - 9 1/8"1' - 4"1' - 4"OPENING6' - 0 1/4"8"OPENING14' - 11 1/2"1' - 4"OPENING8' - 6 3/4"S-1112' - 1"5' - 3 1/2"F1F1F1ELECTRICAL CONTRACTOR TO INSTALL 1/2" CONDUIT FOR COLUMN LIGHTS PRIOR TO SLAB & COLUMN POURS7S-220' - 6 1/8"3' - 6"3' - 6"7' - 8 7/8"3' - 6"2' - 1"20' - 5 1/2"S-28GRC 2-PLY GIRDER ABOVEGRH 2-PLY GIRDER ABOVEGRL 3-PLY GIRDER ABOVE9S-210S-2S-211CORNER PAD REFER TO CALLOUTCORNER PAD REFER TO CALLOUTWALL PADREFER TO SECTION VIEWSHOWER RECESSSHOWER RECESS2' - 9 3/4"2' - 9 3/4"135.00 °45* BlockW/(2) #5 VERTOPENING3' - 2 1/4"2' - 4"7' - 5"2' - 4" F2 F3 F3 2"1' - 8"8' - 5"1' - 8" 2"2"1' - 4"3' - 9 1/2"3' - 0 1/4"2' - 4 1/4"4 3/8" DOUBLE SWING DOOR 6' - 8 1/4"4 3/8" 1' - 10"11 7/8"10 1/4" 8"5' - 3 1/2"5' - 3 1/2"5' - 4 1/2"8" x 12"8" x 12" ALL STEEL #5 VERT FILLED W/3000# PUMP MIX 6"8" 4"9' - 1"4" 8" 6"6"8"4' - 1 1/2"F1 F1 F1 10' - 11 3/4" -4" SHOWER RECESS LINE 2 7 5/8"4' - 2 1/2"7 5/8"9' - 8 1/2"7 5/8" 16" W X 20" D - MONOLITHIC CONTINUOS FOOTER W/(2) #5 REBAR CONT.F1 F2 F3 20" W X 18" D - FOOTER W/(3) #5 REBAR CONT. 24" W X 18" D - FOOTER W/(3) #5 REBAR CONT. F4 36" W X 36" L x 24" D - PAD W/(8) #5 REBAR GRID7 1/4"F5 18" W X 18" D - INT. BEARING FOOTER W/(2) #5 REBAR CONT. ScaleVILLADELTA CONSTRUCTION CORP. LLC CRC 058035THE DESIGN PROFESSIONAL OF RECORD (ENGINEER AND/OR ARCHITECT) ASSUMES ALL RESPONSIBILITY OF THE SPECIFICATIONS CONTAINED HERE IN. IT IS THE CLIENT'S AND/OR CONTRACTOR'S RESPONSIBILITY TO VERIFY THE FINAL PLANS AND MEASUREMENTS. ALL CHANGES FROM THIS POINT FORWARD WILL NEED A SIGNED CHANGE ORDER BEFORE ANY ADDITIONAL WORK OR MODIFICATIONS WILL BE MADE. ALL WRITTEN CHANGE ORDERS SUPERCEED THE DRAWINGS. THE DRAWINGS ARE CONCEPTUAL DESIGNS AND MAY VARY FROM THE FINISHED PROUCT. THESE DRAWINGS ARE THE PROPERTY OF THE DISIGNER AND SHALL NOT BE REPRODUCED, MODIFIED OR ALTERED WITHOUT PRIOR WRITTEN CONSENT. THESE DRAWINGS WILL REMAIN THE PROPERTY OF THE DESIGNER EVEN IF THEY ARE NOT USED IN THE CONSTRUCTION OF THIS PROJECT. COPYRIGHTT 2016 PRONTO PLANS, L.L.C. ___________________________________CLIENT'S APPROVAL DATE As indicated 11/24/2021 12:48:40 AM S-12401 Noble Oaks LaneFt. Pierce, FL 34981Dudley Residence 1/4" = 1'-0"5Foundation 1/2" = 1'-0"3 Foundation - Rear Angle Wall Joins Rev. # DescriptionDate 1/2" = 1'-0"1 Foundation - Entry & Column Callout 3/8" = 1'-0"2 Master Shower Recess -4" 1/4" = 1'-0" Footer Legend I HEREBY CERTIFY AS THE BUILDING DESIGN ENGINEER OF RECORD, THAT THE BUILDING DESIGN AS SHOWN ON THESE PLANS (STRUCTURAL COMPLIANCE ONLY) AND AS ACCOMPANIED BY DESIGN AND SUPPORT DOCUMENTS, CONFORMS TO THE 2020 7th EDITION FLORIDA BUILDING CODE. THIS CERTIFICATION DOES NOT INCLUDE ROOF TRUSS COMPONENTS OF WHICH THE TRUSS DESIGN ENGINEER IS THE ENGINEER OF RECORD. THESE PLANS HAVE BEEN PREPARED IN COMPLIANCE WITH THE 2020 7th EDITION FLORIDA BUILDING CODE WITH SUPPLEMENTS.Craig E. Gunderson, P.E. #060102Date:FLORIDA ENGINEERING, LLC 4161 TAMIAMI TRAIL, UNIT 101 PORT CHARLOTTE, FL. 33952 PH: (941) 391-5980FAX: (941) 979-8196 First Floor0"First Floor0" Entry Roof15' - 7" Main Roof10' - 1" B B 1' - 2"6080 FD 1 PW 6020 1 10' - 3 3/4"1' - 9 1/4"MIN. 5/8" STUCCO OVER RIB LATH R30 TO BTM TRUSS CORD 1 1/2" X 12 STUCCO BAND 8"W X 14"D FORMED TIE BEAM 3000# PUMP MIX W/(4) #5 CONT. 8" LINTEL W (1) #5 - 8F80T1B FRONT & BOTH SIDES OF ENTRY 3" X 10 STUCCO BAND WRAPS AROUND ENTRY 10' - 1"1' - 0"12' - 1"1' - 0"11' - 1"TRUSS BEARING PT. MIN. 5.5" SPRAY FOAM INSL. OPEN CELL SPRAY FOAM 8"W X 17.5"D FORMED TIE BEAM 3000# PUMP MIX W/(4) #5 CONT.1' - 11"8' - 2"9"W X 2"D RECESS FOR SLIDER F1 F1 F1 F2 R30 BATT INSULATION R30 BATT INSULATION 8' - 2" 26806080 SLIDER XX 6 12080 SLIDER 7 TRUSS BEARING PT.1' - 0"9' - 5"8"W X 12"D FORMED TIE BEAM 3000# PUMP MIX W/(4) #5 CONT. 8"W X 23"D FORMED TIE BEAM 3000# PUMP MIX W/(6) #5 CONT. COLUMNS STEEL #5 VERT FILLED W/3000# PUMP MIX DECORATIVE APPLIED STONE First Floor 0" Main Roof10' - 1" 7' - 9 7/8"5' - 1"7' - 9 7/8" Elevated Front12' - 1" A A 1' - 11"5' - 1 3/4"3' - 4 1/4"PW 5050 OBSCURE 31' - 2"8"W X 14"D FORMED TIE BEAM 3000# PUMP MIX W/(4) #5 CONT. 4' - 8F8-0B/0T PRE STRESSED LINTEL W/(1) #5 3000# PUMP MIX 1' - 4"8"8" FORMED SILL W/(1) # 5 3000# PUMP MIX 3080 S-2 5sim 7' - 4"First Floor0" Main Roof 10' - 1" A A 2' - 5"8' - 0"FORMED & POURED BEAM W/(2)#5 TOP, (2) #5 MID, (2)#5 BTM & WIRE TIES/ STIRRUPS 12" O.C. 3000# PUMP MIX CEMENT S-2 6 F1 First Floor0" Entry Roof15' - 7" Elevated Front 12' - 1"10"2' - 0"8' - 2 3/4"1' - 10 1/4"8"1' - 4"8" FORMED SILL W/(1) # 5 3000# PUMP MIX 8"W X 20"D FORMED TIE BEAM 3000# PUMP MIX W/(4) #5 CONT. 3" 12" COLLAR BAND 1 1/2" BEYOND STUCCO 10" BAND 3" BEYOND STUCCO S-2 5 F2 F1 8"2"6"2"8" FORMED SILL W/(1) # 5 3000# PUMP MIX ALL BANDING DIMENSIONS BEYOND STUCCO 6"BEYOND STUCCO 1" First Floor0" Foundation-1' - 8" Main Roof10' - 1" 2' - 0"1' - 8"24"W X 28"L X 24"D W/(3)#5 E.W. 2 7 S-2 2' - 0"2' - 4"1' - 0"1' - 4"GRH 2-PLY GIRDER OVER MASTER BATH 24"W X 28"L X 24"D W/(3)#5 E.W. F1 F1 F1 First Floor 0" Foundation-1' - 8"1' - 8"3' - 6"2' - 0"SHOWER RECESS LINE 42" W X 42" L X 24" D W/(5) #5 E.W. First Floor0" Foundation-1' - 8"1' - 8"4"2"9" 3' - 6" 1' - 5"2' - 1" 42"W X 42"L X 24"D W/(5) #5 E.W. 10 S-2 1' - 11"1' - 7"2' - 1"1' - 5" 3' - 6"3' - 6"F1 F1 42"W X 42"L X 24"D W/(5) #5 E.W. ScaleVILLADELTA CONSTRUCTION CORP. LLC CRC 058035THE DESIGN PROFESSIONAL OF RECORD (ENGINEER AND/OR ARCHITECT) ASSUMES ALL RESPONSIBILITY OF THE SPECIFICATIONS CONTAINED HERE IN. IT IS THE CLIENT'S AND/OR CONTRACTOR'S RESPONSIBILITY TO VERIFY THE FINAL PLANS AND MEASUREMENTS. ALL CHANGES FROM THIS POINT FORWARD WILL NEED A SIGNED CHANGE ORDER BEFORE ANY ADDITIONAL WORK OR MODIFICATIONS WILL BE MADE. ALL WRITTEN CHANGE ORDERS SUPERCEED THE DRAWINGS. THE DRAWINGS ARE CONCEPTUAL DESIGNS AND MAY VARY FROM THE FINISHED PROUCT. THESE DRAWINGS ARE THE PROPERTY OF THE DISIGNER AND SHALL NOT BE REPRODUCED, MODIFIED OR ALTERED WITHOUT PRIOR WRITTEN CONSENT. THESE DRAWINGS WILL REMAIN THE PROPERTY OF THE DESIGNER EVEN IF THEY ARE NOT USED IN THE CONSTRUCTION OF THIS PROJECT. COPYRIGHTT 2016 PRONTO PLANS, L.L.C. ___________________________________CLIENT'S APPROVAL DATE As indicated 11/24/2021 12:48:42 AM S-22401 Noble Oaks LaneFt. Pierce, FL 34981Dudley Residence 1/4" = 1'-0"1Section Thru Front Door 3/8" = 1'-0"3Garage & Section Laundry Window 3/8" = 1'-0"4Typ. Garage Door Header 3/8" = 1'-0"2 Section Den Window 1" = 1'-0"5 Typical Window Sill & Banding 1" = 1'-0"6 Typ. Garage Door Banding Rev. # DescriptionDate 1/4" = 1'-0"7Master Bath Corner Pad 1/2" = 1'-0"8Foundation - Master Bathroom 1/2" = 1'-0"9Bedroom & Bath #3 Pad 1/2" = 1'-0"10Porch Corner Pad for GRL 1/2" = 1'-0"11 Foundation - Porch Corner GRL I HEREBY CERTIFY AS THE BUILDING DESIGN ENGINEER OF RECORD, THAT THE BUILDING DESIGN AS SHOWN ON THESE PLANS (STRUCTURAL COMPLIANCE ONLY) AND AS ACCOMPANIED BY DESIGN AND SUPPORT DOCUMENTS, CONFORMS TO THE 2020 7th EDITION FLORIDA BUILDING CODE. THIS CERTIFICATION DOES NOT INCLUDE ROOF TRUSS COMPONENTS OF WHICH THE TRUSS DESIGN ENGINEER IS THE ENGINEER OF RECORD. THESE PLANS HAVE BEEN PREPARED IN COMPLIANCE WITH THE 2020 7th EDITION FLORIDA BUILDING CODE WITH SUPPLEMENTS. Craig E. Gunderson, P.E. #060102 Date: FLORIDA ENGINEERING, LLC 4161 TAMIAMI TRAIL, UNIT 101 PORT CHARLOTTE, FL. 33952 PH: (941) 391-5980 FAX: (941) 979-8196 3S-2SH25EGRESS612' - 0"20' - 0"8' - 9"12' - 1"9' - 0 1/2"10' - 11 3/4"2' - 0"72' - 10 1/4"18' - 0"7' - 9 7/8"5' - 1"7' - 9 7/8"2"10S-411' - 4 1/4"OPTIONAL CLOSET8' - 7 7/8"4' - 0 3/8"2' - 6"19' - 3 1/4"56' - 1 5/8"77' - 10 7/8"5' - 3 1/2"8' - 9"11' - 11 5/8"48' - 0 3/8"9' - 10 3/4"8' - 0 1/4"65' - 11 1/4"31' - 5 3/4"15' - 9 1/8"16' - 2 5/8"63' - 5 1/2"3e2e3e1e3e3e1e8' - 9"4iCA 2660-222CA 2660-220PW 202019CA 26602PW 5050OBSCURE3SH35EGRESS13SH35EGRESS12SH25EGRESS4SH14 TEMPOBSCURE14SH25EGRESS8SH25EGRESS9SH23 TEMPOBSCURE7SH35EGRESS10SH35EGRESS11PW 202017SH 2833OBSCURE5CA 202018PW 196015PW 1960164' - 5 1/4"13' - 4 5/8"3' - 8 1/2"10' - 10 1/2"14' - 4 1/4"7 5/8"5' - 10 1/2"4' - 4 1/2"5' - 4 1/4"11' - 4 1/4"2' - 4 1/2" 4' - 0 1/2" 5' - 10 5/8"9' - 11 1/4"4' - 5 3/4"6' - 10 3/4"13' - 6 1/4"2' - 4 3/4" 3' - 10 3/4"7' - 2 1/2"3' - 0 1/2" 2' - 4 1/2"8' - 7 3/4"4' - 10 1/4"4' - 0" 4' - 10 1/2"7 5/8"13' - 6 3/8"2' - 4 5/8" 6' - 10 1/2" 2' - 8 1/2"6' - 11"9' - 0 5/8"3' - 10 1/2" 5' - 4 1/2"13' - 6 1/4"3' - 10 1/2"4' - 3"5' - 8 1/2"2' - 4 1/2"13' - 9 3/4"8' - 3"8' - 5 1/4"7 5/8"9 3/4"2' - 0 3/4"6 1/2"FINISHED3' - 4"4' - 9 1/2"2' - 4 1/2"13' - 4 1/2"5' - 4 3/8"4' - 8"9' - 7 3/4"4' - 3 1/4"1' - 4 1/4"1' - 2 1/2"1' - 9 1/4"7 5/8"13' - 5 1/8"9' - 6"6' - 7"FINISHED2' - 8" 4' - 4 1/2"FINISHED2' - 8" 7 5/8"3080583080572680592680605080 BF563080552680543080412680462680472880436080 BF443080 EXT.402880452880502880516080 BF522880533080 Panel48080 GD316080 GD26080 FD112080 SLIDER76080 SLIDER XX62880 FD51122BBAA20' - 6"2' - 6"16' - 3 1/2"5 1/4"SUSPENDED AIR HANDLER2' - 7 5/8"5' - 4"8' - 10 3/4"2' - 9 5/8"2' - 9 5/8"15' - 6"1' - 7 5/8"1' - 6 7/8"18' - 1 1/8"3' - 2"2' - 0"3' - 2"13' - 2"2' - 9"2' - 2"3' - 2"8' - 5 1/2"4' - 5 1/8"6' - 4"4' - 5 1/8"9' - 0 1/4"2' - 8 7/8"2' - 1 7/8"6' - 2"1' - 4"1' - 4"12' - 2"1' - 7 1/2"3' - 11"9' - 0 1/4"3' - 11"26' - 10 1/2"1' - 8 1/8"3' - 10 1/2"1' - 10"5' - 11 3/4"1' - 10"5' - 11 1/2"1' - 4"2' - 1"1' - 0 3/8"2' - 1"1' - 0 3/8"2' - 1"1' - 4"4' - 2 1/2"5' - 1 1/2" 2' - 0 1/2"3' - 2"2' - 7" 5' - 4"5 1/2"6' - 6"5 1/2"2' - 0"8' - 0"2' - 0" 2' - 0"16' - 0"2' - 0"32' - 0"40' - 10 1/4"PW 2620-221PW 2620-223PW 60201ACTIVE FIXED 2e2e1e1e2e1i1i1i1i4i1i1i1i2e1i2X4 WOOD BEARING 1/2" DRYWALL LIVING 5/8" TYPE "X" GARAGE1i1i1i34-1/2" HIGH WALL TOSUPPORT CABINETS1i1i1S-22S-24S-25' - 0"4' - 1 3/4"7' - 0"4' - 1 3/4"1' - 5 1/2"11 1/2"S-438S-46 1/2"4 5/8"13' - 8 3/4"14' - 11 1/2"11S-45080 BF485080 BF498B1i1i9S-42e2e2e3080 BF42ATTIC ACCESS 22" X 36"P.C.ATTIC ACCESS WITH LADDER VERIFY LOCATION ON SITEP.C.IRONING BOARD2X6 IN FRONT OF RIGID INS.7 1/4"7 5/8"FINISHEDScaleVILLADELTA CONSTRUCTION CORP. LLC CRC 058035THE DESIGN PROFESSIONAL OF RECORD (ENGINEER AND/OR ARCHITECT) ASSUMES ALL RESPONSIBILITY OF THE SPECIFICATIONS CONTAINED HERE IN. IT IS THE CLIENT'S AND/OR CONTRACTOR'S RESPONSIBILITY TO VERIFY THE FINAL PLANS AND MEASUREMENTS. ALL CHANGES FROM THIS POINT FORWARD WILL NEED A SIGNED CHANGE ORDER BEFORE ANY ADDITIONAL WORK OR MODIFICATIONS WILL BE MADE. ALL WRITTEN CHANGE ORDERS SUPERCEED THE DRAWINGS. THE DRAWINGS ARE CONCEPTUAL DESIGNS AND MAY VARY FROM THE FINISHED PROUCT. THESE DRAWINGS ARE THE PROPERTY OF THE DISIGNER AND SHALL NOT BE REPRODUCED, MODIFIED OR ALTERED WITHOUT PRIOR WRITTEN CONSENT. THESE DRAWINGS WILL REMAIN THE PROPERTY OF THE DESIGNER EVEN IF THEY ARE NOT USED IN THE CONSTRUCTION OF THIS PROJECT. COPYRIGHTT 2016 PRONTO PLANS, L.L.C. ___________________________________CLIENT'S APPROVAL DATE 1/4" = 1'-0" 11/24/2021 12:48:44 AM S-32401 Noble Oaks LaneFt. Pierce, FL 34981Dudley ResidenceArea Calculations Name Area LIVING 2833 SF GARAGE 653 SF LANAI 223 SF DINING PATIO 203 SF FT. PORCH 104 SF Grand total: 5 4015 SF 1/4" = 1'-0"1First Floor FramingRev. # DescriptionDateI HEREBY CERTIFY AS THE BUILDING DESIGN ENGINEER OF RECORD, THAT THE BUILDING DESIGN AS SHOWN ON THESE PLANS (STRUCTURAL COMPLIANCE ONLY) AND AS ACCOMPANIED BY DESIGN AND SUPPORT DOCUMENTS, CONFORMS TO THE 2020 7th EDITION FLORIDA BUILDING CODE. THIS CERTIFICATION DOES NOT INCLUDE ROOF TRUSS COMPONENTS OF WHICH THE TRUSS DESIGN ENGINEER IS THE ENGINEER OF RECORD. THESE PLANS HAVE BEEN PREPARED IN COMPLIANCE WITH THE 2020 7th EDITION FLORIDA BUILDING CODE WITH SUPPLEMENTS. Craig E. Gunderson, P.E. #060102 Date: FLORIDA ENGINEERING, LLC 4161 TAMIAMI TRAIL, UNIT 101 PORT CHARLOTTE, FL. 33952 PH: (941) 391-5980 FAX: (941) 979-8196 1e 5/8" STUCCO 7 5/8" CMU 5/8" STUCCO 5/8" STUCCO 7 5/8" CMU 3/4" RIDGID FOAM INSULATION 3/4" P.T. FURRING STRIP 16" OC 1/2" DRYWALL 2" APPLIED STONE FACADE STUCCO SCRATCH COAT WATER PROOFING MEMBRANE 7 5/8" CMU 3/4" RIDGID FOAM INSULATION 3/4"" P.T. FURRING STRIP 16" OC 1/2" DRYWALL 2e 4e 5/8" STUCCO 7 5/8" CMU 3/4" RIDGID FOAM INSULATION 3/4" P.T. FURRING STRIP 16" OC 1/2" DENS GLASS 3e 7i 5i 4i 2i 1i 1/2" DRYWALL 3 1/2" STUD 1/2" DRYWALL 1/2" DRYWALL 3 1/2" STUD 5/8" DRYWALL TYPE "X" 1/2" DRYWALL 5 1/2" STUD 1/2" DRYWALL 1/2" DRYWALL 5 1/2" STUD 5/8" DRYWALL TYPE "X" 1/2" DRYWALL 15" FRAMING 1/2" DRYWALL 6i 1/2" MOSAIC TILE 1/2" DENS GLASS 7 1/4" STUD 1/2" DENS GLASS 1/2" MOSAIC TILE 3i 1/2" DRYWALL 3 1/2" STUD 1/2" DENS GLASS 9B 8B 1/2" DRYWALL 3 1/2" WOOD STUD BEARING 58/" DRYWALL TYPE X 1/2" DRYWALL 5 1/2" WOOD STUD BEARING 1/2" DRYWALL 10B 1/2" DRYWALL 7 1/4" WOOD STUD BEARING 1/2" DRYWALL INTERIOR NON-BEARING WALL TO BE 16" OC WOOD LUMBER USED FOR STUDS IN INTERIOR NON BEARING PARTITIONS SHALL BE A STRESS GRADE NOT LESS THAN 225 P.S.I. NOMINAL EXTREME FIBER STRESS IN BENDING. MIN. 5/8" TWO COAT DECORATIVE STUCCO FINISH 2" X 8" HEMP FIR FASCIA, 1" X 2" PT UNDER DRIP EDGE W/FLAT STUCCO SOFFITS OVER HIGH RIB LATH METAL STANDING SEAM FASTENED TO SELF ADHESIVE MEMBRANE OVER 5/8" CDX PLYWOOD, ON PRE-ENG. TRUSSES AT 24"c.c. 1/2" DRYWALL 8" X 12" POURED CONCRETE TIE BEAM WITH (4) #5 CONT., LAP 48 DIA. MIN. OR AS NOTED ON FLOOR PLAN 8" X 16" CONC. BLOCK WITH #5 VERT. DOWEL IN CONC. FILLED CELLS AS PER PLAN 1" X 2" P.T. FURRING 16" O.C. ON 3/4" R5 RIGID INSULATION 1/2" DRYWALLREFER TO ELEVATIONS REFER TO ELEVATIONS #5 REBAR VERT. POURED CELL REFER TO FOUNDATION PLAN FOR SPACING & 16"WIDE x 20" DEEP FOOTER W/(2) #5 REBAR CONT. ALL LAPS 30" MIN. BTM OF FOOTER MIN. 12" BELOW GRADE CLEAN COMPACTED FILL PER SITE PREPARATION NOTE ON PAGE "A-2" 8" X 16" CMU 4"SEE TRUSS CONNECTION PAGE S-6 SPRAY E D O P E N C E L L F O A M 1' - 8"1' - 4" SEE TRUSS TAIL DETAIL PAGE S-4 REFER TO ELEVATIONS FOR ROOF PITCH FROM FURRING4' - 2 3/4"6' - 11"4' - 2 3/4"5 1/2"11 1/2" 1' - 5 1/2" ALL DIMENSIONS IN THIS VIEW ARE ROUGH FRAMED 12 S-5 6" 13 S-5 First Floor 0" Main Roof10' - 1" 6' - 11"10' - 1"3080 55 First Floor0" Main Roof10' - 1" 4' - 4 1/2" First Floor 0" Main Roof 10' - 1" 14"H X 22"W 3' - 6"First Floor0" Main Roof10' - 1"4' - 3 1/4"2' - 7"FINISHED 1' - 3" 1' - 2 3/8"IRONING BOARD DIMS BASED ON IRON-A-WAY AE-42 and ANE-42 A.H.U . PRO ENG. TRUSSES SEE SHOP DRAWINGS FOR EXACT LOCATION OF OPTIONAL COFFER TREADED ROD SUPPORT FOR A.H.U. FROM PRO. ENG. TRUSS ABOVE FASTEN WITH 1/2" WASHER & NUT A.H.U. ABOVE DRAIN PAN CEILING GYM. WALL BOARD (2) MSTA18 (14) 10d NAILS SPHx AT EVERY STUD WITH (6) 10d NAILS TOP & SOLE PLATE (2) 2 x STUDS 2 x PT. PLATE (2) 2 x TOP PLATE FINISHED FLOOR 5/8" x 6" TITEN HD BOLTS WITH 1/8" x 2" HOT DIPPED GALV. WASHER AT 32" o.c. OR WEDGE ANCHORS FRAMING LUMBER TO BE MIN. 2 x 4 OR AS PER PLAN FOR EXTERIOR: FINISH TO BE STUCCO OVER PAPER BACKED RIB LATH (2) 2 x 12 HEADER BOND TOGETHER WITH 16d AT 6" o.c. STAGGERED ATTACH TRUSSES TO TOP PLATE AS PER CONNECTOR SCHDLE FOR EXTERIOR WALL APPLICATION PROVIDE 1/2" C.D.X PLYWOOD ON OUTSIDE FACE OF STUDS, FASTEN PER STRUCTURAL NOTES BTM. OF FTNG. SPHx 16" o.c. SEE CONNECTOR SCHEDULE FOR FASTNER INFORMATION 1/2" DRYWALL SIMPSON "SPH" FASTNER AT EACH STUD STUDS 16" O.C. 1/2" DRYWALL EACH SIDE OF STUDS 4" 3000# FIBERMIX CONCRETE ON .006 VAPOR BARRIER OVER CLEAN, COMPACTED, TERMITE TREATED FILL REFERENCE FLOOR PLAN FOR CEILING HEIGHTS(2) 2X4 TOP PLATE CONTINUOS SIMPSON "SPX" FASTNER AT EACH STUD 2X PT. PLATE FASTENED TO THE FOUNDATION WITH 1/2" x 6" SIMPSON TITEN HD 32" o.c. USE 1/8" x 2" HOT DIPPED GALV. WASHERS INTERIOR BEARING FOOTING WITH (2) #5 CONT. REBAR UNLESS OTHERWISE NOTED18"4"14"REFER TO ROOFING NOTES FOR TYPICAL WALL SECTION WIRE LATH WITH DECORATIVE STUCCO FINISH 8" X 16" CONC. BLOCK OR OTHER AS SPECIFIED TRUSS BEARING POURED CONCRETE BEAM REFER TO TRUSS PLAN ScaleVILLADELTA CONSTRUCTION CORP. LLC CRC 058035THE DESIGN PROFESSIONAL OF RECORD (ENGINEER AND/OR ARCHITECT) ASSUMES ALL RESPONSIBILITY OF THE SPECIFICATIONS CONTAINED HERE IN. IT IS THE CLIENT'S AND/OR CONTRACTOR'S RESPONSIBILITY TO VERIFY THE FINAL PLANS AND MEASUREMENTS. ALL CHANGES FROM THIS POINT FORWARD WILL NEED A SIGNED CHANGE ORDER BEFORE ANY ADDITIONAL WORK OR MODIFICATIONS WILL BE MADE. ALL WRITTEN CHANGE ORDERS SUPERCEED THE DRAWINGS. THE DRAWINGS ARE CONCEPTUAL DESIGNS AND MAY VARY FROM THE FINISHED PROUCT. THESE DRAWINGS ARE THE PROPERTY OF THE DISIGNER AND SHALL NOT BE REPRODUCED, MODIFIED OR ALTERED WITHOUT PRIOR WRITTEN CONSENT. THESE DRAWINGS WILL REMAIN THE PROPERTY OF THE DESIGNER EVEN IF THEY ARE NOT USED IN THE CONSTRUCTION OF THIS PROJECT. COPYRIGHTT 2016 PRONTO PLANS, L.L.C. ___________________________________CLIENT'S APPROVAL DATE As indicated 11/24/2021 12:48:46 AM S-42401 Noble Oaks LaneFt. Pierce, FL 34981Dudley Residence 1/2" = 1'-0" Wall Legend - Exterior 1/2" = 1'-0" Wall Legend - Interior 1 1/2" = 1'-0"1 Truss Tail Detail NTS Rev. # DescriptionDate 1/2" = 1'-0"2 TYPICAL WALL SECTION DETAIL FLAT SOFFITS (N.T.S.) 1/2" = 1'-0"3First Floor Framing - Entertainment Wall 3/8" = 1'-0"11 Foyer to Great Room Opening 1/2" = 1'-0"10Master Bath Shower 1/2" = 1'-0"8Master Shower Niches 1/2" = 1'-0"9Wall Mounted Ironing Board 1 : 206 SUSPENDED AIR HANDLER DETAIL (N.T.S.) 1/2" = 1'-0"5 TYPICAL HEADER ATTACHMENT DETAIL (N.T.S.) 1/2" = 1'-0"4 INTERIOR BEARING WALL DETAIL (N.T.S.) 1/2" = 1'-0"7 PORCH & ENTRY CEILING - POURED BEAM DETAIL (N.T.S.) I HEREBY CERTIFY AS THE BUILDING DESIGN ENGINEER OF RECORD, THAT THE BUILDING DESIGN AS SHOWN ON THESE PLANS (STRUCTURAL COMPLIANCE ONLY) AND AS ACCOMPANIED BY DESIGN AND SUPPORT DOCUMENTS, CONFORMS TO THE 2020 7th EDITION FLORIDA BUILDING CODE. THIS CERTIFICATION DOES NOT INCLUDE ROOF TRUSS COMPONENTS OF WHICH THE TRUSS DESIGN ENGINEER IS THE ENGINEER OF RECORD. THESE PLANS HAVE BEEN PREPARED IN COMPLIANCE WITH THE 2020 7th EDITION FLORIDA BUILDING CODE WITH SUPPLEMENTS. Craig E. Gunderson, P.E. #060102 Date: FLORIDA ENGINEERING, LLC 4161 TAMIAMI TRAIL, UNIT 101 PORT CHARLOTTE, FL. 33952 PH: (941) 391-5980 FAX: (941) 979-8196 2"X8" P.T. AT VERTICAL SIDES OF OPENING & 2"X4" ACCROSS TOP FASTEN TO BLOCK WITH 1/2"X6" SIMPSON TITEN HD WITH MIN. 2" DIAMETER X 1/8" WASHER (TYP.) SPACING AS NOTED DOOR SIDES=12" FROM ENDS & 24" o.c. MAXIMUM AT MIDDLE 8"X16" C.M.U. WITH CELLS FILLED WITH 3000# GROUT & (1) #5 VERTICAL DOWEL DOOR OPNG.EXTERIOR WALL8 "#5 REBAR CONTINUOS #3 TIES 8" O.C. RQRD. (1) #7 REBAR ATTACH REBAR TO ADJACENT COLUMNS WITH 90 DEGREE HOOKS (MIN. 48 DIA.LAP.) 1'- 4" 1"X2" P.T. DRYWALL 3/16" TAPCON, 1 1/4" EMBEDED IN MASONRY 8" FROM ENDS AND 12" c.c. 1"X6" P.T. BUCK PRE-HUNG DOOR JAMB 3000# GROUT FILLED CELL, SEE PLAN FOR VERTICAL REQUIREMENTS 90 DEGREE HOOKS 48 DIA OVERLAP MIN. SOLID POURED CELLS WITH (1)#5 CONTINUOUS REBAR FROM BEAM TO FOOTING FOR HORIZ. TIE BEAM STEEL REQUIREMENTS, SEE TYP. WALL SECTION 1"X2" P.T. STUCCO FINISH RETURNED TO WINDOW FRAME AT EXTERIOR DRYWALL 3/16" TAPCON, 1 1/4" EMBEDED IN MASONRY 8" FROM ENDS AND 12" c.c. 1"X6" P.T. WINDOW BUCK (AT SIDES & WINDOW HEAD) 2"X6" AT SILL 3000# GROUT FILLED CELL, SEE PLAN FOR VERTICAL REQUIREMENTS 3/4" RIGID INSULATION 2"X (x)" P.T. PLATE FASTENED TO TIE BEAM WITH 1/2" X 6" SIMPSON TITEN HD BOLTS WITH 1/8" X 2" WASHER AT 12" FROM ENDS & 24" o.c. 2" X (x)" STUDS 16" o.c. TOP PLATE (2) 2"X (x)" SPX AT EVERY STUD WITH (6) 10d NAILS TOP & SOLE PLATE 2" X STUDS 16" o.c. TOP PLATE(2) 2"X SPX AT EVERY STUD WITH (6) 10d NAILS TOP & SOLE PLATE KNEE WALL LUMBER SIZE NEEDS TO BE EQUAL TO WALL SIZE AS NOTED ON TRUSS LAYOUT OR AS SPECIFIED (2) 2 X PLATE SPX AT EVERY STUD WITH (6) 10d NAILS LSTA 24 AT 16"c.c FILL HOLES WITH 10d NAILS 1 x PT WOOD BUCK 1/4" ELCO TAPCON REQUIRED MIN. 1 1/4" CONC. EMBED. TYPICAL HEAD ANCHORAGE USING A 1x PT WOOD BUCK 1 x PT WOOD BUCK TYPICAL JAMB ANCHORAGE USING A 1x PT WOOD BUCK 1/4" ELCO TAPCON REQUIRED MIN. 1 1/4" CONC. EMBED. 2 x WOOD BUCK 1/4" ELCO TAPCON SEE WINDOW SCHEDULE ATTACHMENT REQUIREMENTS TYPICAL SILL ANCHORAGE USING A 2x WOOD BUCK First Floor0" Main Roof10' - 1"1' - 0"9' - 1"6 7/8"3' - 0"6 7/8"7' - 0"4' - 1 3/4"6 1/2" LINEAR FIREPLACE NEFL60CFH 5' - 1"2' - 10 1/4"70" TV MUST CONFIRM TV & FIREPLACE HEIGHT ON SITE WITH CLIENT 3/4" 4PLY PLYWOOD PL400 & 12d (3 1/4") RINGSHANK NAILS TO 2X4 5/8" DRYWALL 2X12 BLOCKING BEHIND ENTIRE AREA 120V J BOX AT LEAST 10" FROM FINISHED FACE (2) 2X8 PL400 & 10d (2 1/2") RINGSHANK NAILS STAGGERED 5/8" DRYWALL TYPE X FRAMED1' - 5 3/8"FRAMED1' - 4 5/8"FINISHED1' - 4 1/8"4 1/4"2' - 2 1/8"2' - 1 1/2"5 1/2"6' - 6"First Floor0" Main Roof10' - 1"1' - 0"9' - 1"6 7/8"3' - 0" 6 7/8"7' - 0"4' - 1 3/4"6 1/2" LINEAR FIREPLACE NEFL60CFH 1' - 0 5/8"4' - 10 7/8"1' - 0 5/8" 5' - 1"2' - 10 1/4"70" TV ALL DIMENSIONS IN THIS VIEW ARE FINISHED 1' - 4 1/8"1' - 5 1/4"1' - 0"6' - 6"5 1/2"2' - 1 1/2"2" X (x)" P.T. STUD ATTACHED TO 8" C.M.U. WITH 1/4"X3 1/4" TAPCON AT 24" o.c. 8" C.M.U. WALL CONCRETE FILLED CELL 5/8" X 6" TITEN HD BOLTS WITH 1/8" X 2" WASHER AT 24" o.c.2" X 4" P.T. PLATE 2" X (x)" STUDS 16" o.c. TOP PLATE (2) 2" X (x)" SPH4 AT EVERY STUD WITH (6) 10d NAILS TOP & SOLE PLATE FOR AN EXTERIOR WALL APPLICATION PRIVIDE 1/2" C.D.X. PLYWOOD ON OUTSIDE FACE OF STUDS & FASTEN AS PER STRUCTURAL NOTES ScaleVILLADELTA CONSTRUCTION CORP. LLC CRC 058035THE DESIGN PROFESSIONAL OF RECORD (ENGINEER AND/OR ARCHITECT) ASSUMES ALL RESPONSIBILITY OF THE SPECIFICATIONS CONTAINED HERE IN. IT IS THE CLIENT'S AND/OR CONTRACTOR'S RESPONSIBILITY TO VERIFY THE FINAL PLANS AND MEASUREMENTS. ALL CHANGES FROM THIS POINT FORWARD WILL NEED A SIGNED CHANGE ORDER BEFORE ANY ADDITIONAL WORK OR MODIFICATIONS WILL BE MADE. ALL WRITTEN CHANGE ORDERS SUPERCEED THE DRAWINGS. THE DRAWINGS ARE CONCEPTUAL DESIGNS AND MAY VARY FROM THE FINISHED PROUCT. THESE DRAWINGS ARE THE PROPERTY OF THE DISIGNER AND SHALL NOT BE REPRODUCED, MODIFIED OR ALTERED WITHOUT PRIOR WRITTEN CONSENT. THESE DRAWINGS WILL REMAIN THE PROPERTY OF THE DESIGNER EVEN IF THEY ARE NOT USED IN THE CONSTRUCTION OF THIS PROJECT. COPYRIGHTT 2016 PRONTO PLANS, L.L.C. ___________________________________CLIENT'S APPROVAL DATE As indicated 11/24/2021 12:48:47 AM S-52401 Noble Oaks LaneFt. Pierce, FL 34981Dudley ResidenceRev. # DescriptionDate 3/4" = 1'-0"2 GARAGE DOOR BUCK ATTACHMENT DETAIL (N.T.S.) 1/2" = 1'-0"5 GARAGE DOOR HEADER DETAIL (N.T.S.) 3/4" = 1'-0"7 DOOR BUCK ATTACHMENT DETAIL (N.T.S.) 1" = 30'-0"3 CHANGE IN BEAM ELEVATION DETAIL (N.T.S.) 3/4" = 1'-0"4 WINDOW BUCK ATTACHMENT DETAIL (N.T.S.) 1/2" = 1'-0"9 KNEE WALL TO MASONRY DETAIL (N.T.S.) 1/2" = 1'-0"10 KNEE WALL TO STUD WALL DETAIL (N.T.S.) 3" = 1'-0"1WINDOW HEAD 1X PT BUCK 3" = 1'-0"8WINDOW JAMB 1X PT BUCK 3" = 1'-0"6WINDOW SILL 2X PT BUCK 3/4" = 1'-0"13Entertainment Wall Elevation Framing 1/2" = 1'-0"12Entertainment Wall Elevation 1 1/2" = 1'-0"11 WOOD TO MASONRY CONNECTION DETAIL (N.T.S.) I HEREBY CERTIFY AS THE BUILDING DESIGN ENGINEER OF RECORD, THAT THE BUILDING DESIGN AS SHOWN ON THESE PLANS (STRUCTURAL COMPLIANCE ONLY) AND AS ACCOMPANIED BY DESIGN AND SUPPORT DOCUMENTS, CONFORMS TO THE 2020 7th EDITION FLORIDA BUILDING CODE. THIS CERTIFICATION DOES NOT INCLUDE ROOF TRUSS COMPONENTS OF WHICH THE TRUSS DESIGN ENGINEER IS THE ENGINEER OF RECORD. THESE PLANS HAVE BEEN PREPARED IN COMPLIANCE WITH THE 2020 7th EDITION FLORIDA BUILDING CODE WITH SUPPLEMENTS. Craig E. Gunderson, P.E. #060102 Date: FLORIDA ENGINEERING, LLC 4161 TAMIAMI TRAIL, UNIT 101 PORT CHARLOTTE, FL. 33952 PH: (941) 391-5980 FAX: (941) 979-8196 LG11 GRE E KJ3K J 3 J3J3J1J1 J3J3J1J1 E1 E1 2 GRBBKJ5KJ5J5 J5 J5 J1 J3 J1J3J5 J5 J5 J1 J3J1J3 GRC3 GRA A A1 KJ5KJ5J5J5J5J1J3J1 J3 J5J5J5J1J3J1 JA3 A2 ATA ATB ATB ATB ATB GRH 4 GRF KJ5KJ5J5J1J3J1 J3 J5J1J3J1 J3 HGRGGG1G2G3G4G5G6G75KJC5J1JC3J1 JC3 JC5 JC5 JC5 JC5 J5 J5 J5 J5 J5 J5 J5 J5 J5 J5 J5 J5 J5 J5 6 GRK K K1 K2 K3 K4KJ5KJ5J5J5J5J5J5J5J1J3J1 J3J5J5J5J5J5J5J1J3J1 J3 K5 K5 K6GRPPP1P2P3P47KJ5 J1J3J1 J3 J5 J5 JA5 JA5 JA5 GRLGRM GRDDD1D2D3D4D5D6D7D8D9FF1F2G8G9G9G9G8J5 J5 J5 J5 J5 J5 J5 J5 J5 J5 J5 J5 J5 J5 J5 J5 J5 GR2J2MV4MV2MV4 MV2 MV2 MV4 MV6 MV8 MV2MV2MV4MV6MV8MV10MV12MV14VA VB V8 V4 MV8MV6LOAD BEARING AT 15'-7" LOAD BEARING AT 12'-1" LOAD BEARING AT 10'-1" CEILING AT 13'-1" CEILING AT 12'-1" CEILING AT 11'-1" CEILING AT 13'-1" CEILING AT 12'-1" CEILING AT 11'-1" CEILING AT 11'-1" CEILING AT 11'-1" A A/H/U SUSPENDED FROM BOTTOM 2-2X LEDGER BY BUILDER BOTTOM @ 12'-1"2-06-0019-03-0456-01-1077-10-1411-11-0848-00-069-10-128-00-0477-10-1412-00-0020-00-008-11-0011-09-00 9-02-08 10-11-12 72-10-04 9-04-1215-02-0416-03-0815-09-02 16-02-10 72-10-04 8-09-0039-03-062-09-109-10-0012-00-122-11-0611-07-1010-06-101-11-0017-07-1233-04-02 1-06-005-03-0410-10-08 5-04-082-01-10 4-08-042-04-10 1-11-1015-06-002-09-102-09-108-10-1219-09-06 2-07-105-04-0013-05-122-09-129-10-082-09-1222-04-0233-09-0811-04-087-05-0011-01-00 8-09-005-00-001-06-00 3-00-005-01-085-04-0820-08-085-00-0021-01-105-00-00 5-00-001-04-0015-02-04 18-05-02 5-00-00 5-00-00 4-05-0215-01-089-07-144-08-005-00-0011-10 2-01-121-06-087-09-107-00-007-09-10 Hatch Legend 1 1 2 2 B B A A Concrete Slab - 4" (2) 2x10 LEDGER W/(3) 1/2" X 6 1/2" TITEN HD W/#2 WASHER TRUSS HANGER HUS 28 W/(30) SIMPSON SD10 X 2 1/2" (2) FGTR TO 3 PLY GRL W/ (36) 1/4" X 3" SDS TO 3 PLY GIRDER & (4) 1/2" X 5" TITEN HD TO BEAM & POURED CELL (2) FGTR TO 3 PLY GRL W/ (36) 1/4" X 3" SDS TO 3 PLY GIRDER & (4) 1/2" X 5" TITEN HD TO BEAM & POURED CELL (1) MGT TO 2 PLY GRC W/ (22) 0.148 x 3 TO 2 PLY GIRDER & (1) 5/8" THREADED ROD W/12" EMBEDMENT IN TIE BEAM USING SET-XP (1) MGT TO 2 PLY GRC W/ (22) 0.148 x 3 TO 2 PLY GIRDER & (1) 5/8" THREADED ROD W/12" EMBEDMENT IN TIE BEAM USING SET-XP (1) MGT TO 2 PLY GRC W/ (22) 0.148 x 3 TO 2 PLY GIRDER & (1) 5/8" THREADED ROD W/12" EMBEDMENT IN TIE BEAM USING SET-XP TRUSS CONNECTION NOTES: TRUSS TO MASONRY w/UPLIFT UP TO 1,810# USE (1) SIMPSON HETA20 W/(8) 0.162 X 1 1/2" OR EQ. U.N.O. TRUSS TO MASONRY w/UPLIFT FROM 1,811# TO 2,560# USE (2) SIMPSON HETA20 W/(12) 0.162 X 3 1/2" OR EQ. U.N.O. GIRDER TO MASONRY USE (2) SIMPSON HETA20 W/(12) 0.162 X 3 1/2" OR EQ. UNLESS NOTED OTHERWISE TRUSS TO WOOD w/UPLIFT UP TO 1,310# USE (1) SIMPSON HTS20 W/(16) 0.148 X 1 1/2"OR EQ. U.N.O. TRUSS TO WOOD w/UPLIFT FROM 1,311# TO 2,620# USE (2) SIMPSON HTS20 W/(16) 0.148 X 3" OR EQ. U.N.O. ***IF HETA20 IS MISSED OR SKIPPED ON MASONRY, (2) HTSM20 MAY BE USED (10) 0.148 x 1 1/2" TO WOOD & (4) 1/4" x 1 3/4" TO CONCRETE. ScaleVILLADELTA CONSTRUCTION CORP. LLC CRC 058035THE DESIGN PROFESSIONAL OF RECORD (ENGINEER AND/OR ARCHITECT) ASSUMES ALL RESPONSIBILITY OF THE SPECIFICATIONS CONTAINED HERE IN. IT IS THE CLIENT'S AND/OR CONTRACTOR'S RESPONSIBILITY TO VERIFY THE FINAL PLANS AND MEASUREMENTS. ALL CHANGES FROM THIS POINT FORWARD WILL NEED A SIGNED CHANGE ORDER BEFORE ANY ADDITIONAL WORK OR MODIFICATIONS WILL BE MADE. ALL WRITTEN CHANGE ORDERS SUPERCEED THE DRAWINGS. THE DRAWINGS ARE CONCEPTUAL DESIGNS AND MAY VARY FROM THE FINISHED PROUCT. THESE DRAWINGS ARE THE PROPERTY OF THE DISIGNER AND SHALL NOT BE REPRODUCED, MODIFIED OR ALTERED WITHOUT PRIOR WRITTEN CONSENT. THESE DRAWINGS WILL REMAIN THE PROPERTY OF THE DESIGNER EVEN IF THEY ARE NOT USED IN THE CONSTRUCTION OF THIS PROJECT. COPYRIGHTT 2016 PRONTO PLANS, L.L.C. ___________________________________CLIENT'S APPROVAL DATE 1/4" = 1'-0" 11/24/2021 12:48:48 AM S-62401 Noble Oaks LaneFt. Pierce, FL 34981Dudley Residence 1/4" = 1'-0"1Truss Layout Rev. # DescriptionDateTHE TRUSS MANUFACTURER'S LAYOUT APPEARS TO BE IN SUBSTANTIAL COMPLIANCE WITH THE PERMITTING PLANS. CONTRACTOR MUST VERIFY DIMENSIONS, PITCH, HEEL HEIGHTS, OVERHANGS ETC. 2020 7th EDITION RESIDENTIAL BUILDING CODE FLORIDA ENGINEERING, LLC COA #30782 Craig E. Gunderson, P.E. #060102 FLORIDA ENGINEERING, LLC 4161 TAMIAMI TRAIL, UNIT 101 PORT CHARLOTTE, FL. 33952 PH: (941) 391-5980 FAX: (941) 979-8196 1122BBAA12' - 0"20' - 0"29' - 10 1/2"10' - 11 3/4"48' - 0 3/8"9' - 10 3/4"8' - 0 1/4"77' - 10 7/8"56' - 1 3/4"19' - 3 1/4"2' - 5 7/8"15' - 2 1/4"16' - 3 1/2"15' - 9 1/8"16' - 2 5/8"72' - 10 1/4"9' - 4 3/4"63' - 5 1/2"65' - 11 1/4"11' - 11 5/8"CONTRACTOR TO VERIFY ALL MASONRY OPENINGS IN THE FIELD8' - 5 5/8"WINDOW3' - 2" 2' - 2"WINDOW2' - 9"13' - 2"5' - 2"WINDOW3' - 2"18' - 1 1/8"4' - 5 1/8"WINDOW6' - 4"4' - 5 1/8"OPENING14' - 11 1/2"1' - 4"DOOR3' - 2 1/4"1' - 8 3/4"WINDOW9' - 0 1/4"2' - 8 7/8"2' - 1 7/8"SLIDER6' - 2"1' - 4"1' - 3 7/8"WINDOW2' - 1"1' - 0"WINDOW2' - 2"1' - 0"WINDOW2' - 1"1' - 3 7/8"4' - 2"WINDOW5' - 3" 1' - 11 1/2"3' - 1 1/2"WINDOW2' - 8" 5' - 3 1/2"1/8"7' - 9 7/8"WINDOW5' - 1"7' - 9 7/8"2' - 0"GARAGE DOOR16' - 0"2' - 0"2' - 0"GARAGE DOOR8' - 0"2' - 0"1' - 4"DOOR3' - 6" 4' - 6 3/4"3' - 3 3/8"OPENING9' - 0 1/4"3' - 11"1' - 4"SLIDER12' - 2"1' - 7 1/2"9"9"8"OPENING13' - 9 1/8"1' - 4"OPENING8' - 6 3/4"1' - 4"OPENING6' - 0 1/4"8"4 3/8"DOOR6' - 8 1/4" 4 3/8"THIS IS THE OPENING WIDTH DIMENSIONS (REFER TO ELEVATIONS FOR HEIGHTS) FOR THE MASONRY CONTRATORPLEASE REFER TO PAGE "S-1" FOR FOUNDATION PLAN5' - 11 1/2"WINDOW1' - 10" 5' - 11 3/4"WINDOW1' - 10" 3' - 10 1/2"WINDOW1' - 8 1/8"26' - 10 1/2"1' - 4"3' - 9 1/2"1' - 8"8' - 5"1' - 8"1' - 4"3' - 9 1/2"SHOWER RECESSSHOWER RECESSScaleVILLADELTA CONSTRUCTION CORP. LLC CRC 058035THE DESIGN PROFESSIONAL OF RECORD (ENGINEER AND/OR ARCHITECT) ASSUMES ALL RESPONSIBILITY OF THE SPECIFICATIONS CONTAINED HERE IN. IT IS THE CLIENT'S AND/OR CONTRACTOR'S RESPONSIBILITY TO VERIFY THE FINAL PLANS AND MEASUREMENTS. ALL CHANGES FROM THIS POINT FORWARD WILL NEED A SIGNED CHANGE ORDER BEFORE ANY ADDITIONAL WORK OR MODIFICATIONS WILL BE MADE. ALL WRITTEN CHANGE ORDERS SUPERCEED THE DRAWINGS. THE DRAWINGS ARE CONCEPTUAL DESIGNS AND MAY VARY FROM THE FINISHED PROUCT. THESE DRAWINGS ARE THE PROPERTY OF THE DISIGNER AND SHALL NOT BE REPRODUCED, MODIFIED OR ALTERED WITHOUT PRIOR WRITTEN CONSENT. THESE DRAWINGS WILL REMAIN THE PROPERTY OF THE DESIGNER EVEN IF THEY ARE NOT USED IN THE CONSTRUCTION OF THIS PROJECT. COPYRIGHTT 2016 PRONTO PLANS, L.L.C. ___________________________________CLIENT'S APPROVAL DATE 1/4" = 1'-0" 11/24/2021 12:48:49 AM S-72401 Noble Oaks LaneFt. Pierce, FL 34981Dudley Residence 1/4" = 1'-0"5Foundation - Opening DimensionsRev. # DescriptionDateI HEREBY CERTIFY AS THE BUILDING DESIGN ENGINEER OF RECORD, THAT THE BUILDING DESIGN AS SHOWN ON THESE PLANS (STRUCTURAL COMPLIANCE ONLY) AND AS ACCOMPANIED BY DESIGN AND SUPPORT DOCUMENTS, CONFORMS TO THE 2020 7th EDITION FLORIDA BUILDING CODE. THIS CERTIFICATION DOES NOT INCLUDE ROOF TRUSS COMPONENTS OF WHICH THE TRUSS DESIGN ENGINEER IS THE ENGINEER OF RECORD. THESE PLANS HAVE BEEN PREPARED IN COMPLIANCE WITH THE 2020 7th EDITION FLORIDA BUILDING CODE WITH SUPPLEMENTS. Craig E. Gunderson, P.E. #060102 Date: FLORIDA ENGINEERING, LLC 4161 TAMIAMI TRAIL, UNIT 101 PORT CHARLOTTE, FL. 33952 PH: (941) 391-5980 FAX: (941) 979-8196 GENERAL STRUCTURAL NOTES: SITE PREPARATION NOTES: 17. CONCRETE BEAMS SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI AT 28 DAYS, UNLESS OTHERWISE NOTED ALL CONCRETEANY CONCRETE OR ANY MASONRY FROM CRACKING.16. CONCRETE IS TO BE INSTALLED TO THE LATEST PUBLICATIONS OF THE ACI MANUALS THE ENGINEER DOES NOT WARRANT THE SLAB, 14. ALL PERMANENT TRUSS BRACING, IN ADDITION TO TRUSS BRACING SPECIFIED BY THE TRUSS ENGINEER SHALL BE INSTALLED PER THE DETAIL IN THESE SHEETS, & IN ACCORDANCE TO BWT-76 & HIB-91 DESIGNS MAY REQUIRE ADDITIONAL REVIEW AND MODIFICATION.RESPONSIBILITY OF REVIEW OF THE PRE-ENGINEERED SYSTEMS AND ANY COMPLIANCE NECESSARY ANY DEVIATION FROM THE PROPOSED THE DESIGN IS TO ALSO INDICATE THE MAGNITUDE OF THE LOADS AND ANY PROVISIONS REQUIRED, THE CONTRACTOR ASSUMES THETHE DESIGNER THE TRUSS OR FLOOR SYSTEM DESIGN SHALL NOT EXERT LATERAL LOADS ON ANY WALL SYSTEM, INTERIOR OR EXTERIORDESIGNED THEM AND BEAR THE SEAL OF SUCH ENGINEER ALL LATERAL AND CROSS BRACING REQUIRED IS T0 BE SPECIFIED BYTO MEET THE 2020 FBC w/SUPPLEMENTS AND ASCE 7-10 THE DESIGN IS TO INDICATE THE FLORIDA REGISTERED ENGINEER WHO13. THE DESIGN OF ALL PRE-ENGINEERED ROOF TRUSSES INCLUDING GIRDERS FLOOR TRUSSES, AND ALL BEAMS ARE TO BE DESIGNED12. N0 ENVIRONMENTAL STUDIES HAVE BEEN PERF0RMED BY THE ENGINEER, AND IF REQUIRED ARE THE RESPONSIBILITY OF THE CONTRACTORCOMMENT OR COMPLIANCE.AND ORDINANCES SITE DRAINAGE IS ALSO THE CONTRACTORS RESPONSIBILITY THE ENGINEER HAS ACKNOWLEDGED NO REVIEW,11. THE CONTRACTOR IS RESPONSIBLE TO PROVIDE POSITIVE DRAINAGE FROM THE STRUCTURE OR BUILDING TO ALL APPLICABLE CODES COMPONENTS OF THE BUILDING ALL TEMPORARY BRACING IS THE RESPONSIBILITY OF THE CONTRACTOR.IS RESPONSIBLE FOR ERECTION PROCEDURES AND SEQUENCE OF SUCH TO PROVIDE SAFETY OF WORKERS, THE BUILDING AND ALL10. THE STRUCTURE HAS BEEN DESIGNED TO BE SELF-SUPPORTING AND STABLE WHEN CONSTRUCTION IS COMPLETE THE CONTRACTOR AND NO VERIFICATION OR COMPLIANCE IS EXPRESSED OR IMPLIED BY THE ENGINEER.9. HOMEOWNER ASSOCIATION, DEED RESTRICTIONS AND ZONING REQUIREMENTS, ETC ARE THE RESPONSIBILITY OF THE CONTRACTOR SUBJECT THE CONTRACTOR TO ADDITIONAL EXPENSES AND ARE THE SOLE RESPONSIBILITY OF THE CONTRACTOR.AUTHORITY HAVING JURISDICTI0N, AND SUCH REQUIREMENTS MAY ALTER THE ORIGINAL PROPOSED DESIGN THESE ADJUSTMENTS COULDACKNOWLEDGES THAT ADDITIONAL ENGINEERING DETAILS, AND/OR REQUIREMENTS MAY BE REQUESTED/REQUIRED BY THE PERMITTING8. ALL CONSTRUCTION WORK AND DESIGN IS SUBJECT TO THE REVIEW AND INTERPRETATION OF THE BUILDING OFFICIALS. CONTRACTOR TESTING REQUIRED BY THE BUILDING OFFICIAL IF REQUESTED.BUILDING CODE 7th EDITION w/SUPPLEMENTS, AND ASCE7-10 THE CONTRACTOR IS TO PROVIDE ANY INSTALLATION GUIDELINES OR PRODUCT7. CLADDING PRODUCTS ARE TO BE INSTALLED TO THE MANUFACTURES SPECIFICATIONS, AND TO COMPLY WITH THE 2020 FLORIDA6. ENGINEER HAS NOT PROVIDED ANY JOB SITE INSPECTIONS UNLESS SPECIFICALLY ARRANGED CAPACITY OF 2500 PSF, NO GEOTECHNICAL ENGINEERING HAS BEEN PROVIDED BY THE ENGINEER5. PRIOR TO ANY CONSTRUCTION, THE CONTRACTOR IS TO VERIFY THE EXISTING SITE CONDITIONS PROVIDE A MINIMUM SOIL BEARING ENGINEER HAS NOT PROVIDED REVIEW OF SUCH MATERIAL UNLESS OTHERWISE SPECIFIEDORIGINAL SPECIFIED PRODUCT ALL TESTING DATA OR PRODUCT VERIFICATION IS THE RESPONSIBILITY OF THE CONTRACTOR THE4. ANY PRODUCT OR MATERIAL SUBSTITUTION IS PERMITTED AS LONG AS THE SUBSTITUTION IS EQUAL TO OR GREATER THAN THETO THE CODES IDENTIFIED ABOVE3. ENGINEERING DESIGNS PROVIDED IN THESE DETAIL SPECIFICATIONS REPRESENT THE MINIMUM DESIGN CRITERIA FOR CONSTRUCTIONAND ASCE7-102. ALL WORK IS TO BE PERFORMED IN ACCORDANCE WITH THE 2020 FLORIDA BUILDING CODE SECTION 1609 w/SUPPLEMENTS,RESP0NSIBILITY 0F THE C0NTRACT0R/OWNER.FOR WINDOWS AND DOORS AND ATTACHMENT REQUIREMENTS, DIMENSIONS OF PRODUCTS, INCLUDING APPLIANCES ARE THE1. THE CONTRACTOR/OWNER IS TO VERIFY ALL SITE CONDITIONS, PROPERTY DIMENSIONS, AND PRODUCT AVAILABILITY, OPENINGS 18. ALL MASONRY UNITS ARE TO BE INSTALLED PER FBC 2020 7th EDITION. PLACEMENTS SHALL BE IN ACCORDANCE WITH ACI 318. 1/300 RATIO REQUIRED ATTIC VENTILATION 50% OF REQUIRED VENTS TO BE PLACED IN UPPER PORTION OF ATTIC AT LEAST 3' ABOVE EAVE VENTS 1 RIDGE VENT & OFF RIDGE VENT ARE TO BE INSTALLED TO MFG SPECIFICATIONS WITH 2" x 4" MIN 4 RIDGE BLOCKING IS NOT REQUIRED WHEN MINIMUM 7/16" SHEETING 3 OFF RIDGE VENT INSTALLED A MINIMUM OF 12" FROM ROOF PEAK 2 BL0CKING NAILED w/(2) 16d NAILS AT EACH END, EACH PIECE TYPICAL BLOCKING BETWEEN TRUSSES AT EACH SIDE VENT 3. SEE ALUMINUM ENGINEERING SPECIFICATIONS SUPPLIED BY OTHERS FOR FASIA OR OVERHANG REQUIREMENTS WHEN SCREEN 2. TYPICAL DRIP EDGE & SOFFIT/FASCIA INSTALLED TO MFG SPECIFICATIONS 1. MINIMUM 2"x4" SUB FASCIA NAILED T0 TRUSS TAILS w/(2) 16d NAILS AT EACH TRUSS - (EACH PLY WHEN MULTIBLE TRUSS) ENCLOSURES OR STRUCTURAL GUTTERS ARE DESIGNED TO BE ATTACHED TO FASCIΛ E) PROVIDE FILED DENSITY TESTS FOR EACH 1,500 SQ. FT. OF BUILDING AREA FOR EACH FROM ALL ORGANICS OR OTHERWISE DELETERIOUS MATERIALD) ALL CONTROLLED FILL MATERIAL SHALL BE A SELECT GRANULAR MATERIAL FREE ON THE MODIFIED PROCTOR TESTLIFTS AND COMPACT TO A MINIMUM OF 95% OF THE MAXIMUM DRY DENSITY BASEDC)FILL ALL EXCAVATED AREAS WITH APPROVED CONTROLLED FILL PLACE IN 8-INCH THE GE0TECHNICAL ENGINEER/TESTING AGENCY.OF SOFT OR UNSUITABLE MATERIAL EXCAVATE UNSUITABLE SOIL AS DIRECTED BYB) THE SURFACE OF THE EXPOSED SUBGRADE SHALL BE INSPECTED FOR POCKETS DEBRIS AND OTHERWISE UNSUITABLE MATERIAL.A MINIMUM OF 4" OF EXISTING SOIL REMOVE ALL ORGANICS, PAVEMENT, ROOTS,A) WITHIN AN AREA A MINIMUM OF 5 FEET BEYOND THE BUILDING LIMITS EXCAVATE REPORT THE FOLLOWING PROCEDURES SHOULD BE USED AS A MINIMUM: 2. IF THE SITE PREPARATION REQUIREMENTS ARE NOT SPECIFIED BY A GEOTECHNICAL THE RECOMMENDATIONS OF THE SOILS ENGINEER 1. THE BUILDING SHALL BE PREPARED AND TESTED IN ACCORDANCE WITH LIFT OF CONTROLLED FILL GENERAL NOTES: 1. THE STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH THE DRAWINGS OF ALL OTHER DISCIPLINES AND THE SPECIFICATIONS. THE CONTRACTOR SHALL VERIFY THE REQUIREMENTS OF THE TRADES AS TO SLEEVES, CHASES, HANGERS, INSERTS, ANCHORS, HOLES, AND OTHER ITEMS TO BE PLACED OR SET IN THE STRUCTURAL WORK. 2. THE CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLYING WITH ALL SAFETY PRECAUTIONS AND REGULATIONS DURING WORK. THE ENGINEER WILL NOT ADVISE ON NOR ISSUE DIRECTION AS TO SAFETY PRECAUTIONS AND PROGRAMS. 3. THE STRUCTURAL DRAWINGS REPRESENT THE FINISHED STRUCTURE AND DO NOT INDICATE THE METHODS OR MEANS OF CONSTRUCTION. THE CONTRACTOR SHALL PROVIDE ALL TEMPORARY GUYING AND BRACING REQUIRED TO ERECT AND HOLD THE STRUCTURE IN PROPER ALIGNMENT UNTIL ALL STRUCTURAL WORK AND CONNECTIONS HAVE BEEN COMPLETED. THE INVESTIGATION, SAFETY, DESIGN ADEQUACY AND INSPECTION OF ERECTION BRACING, TEMPORARY SUPPORTS ETC. IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR. 4. THE ENGINEER SHALL NOT BE RESPONSIBLE FOR THE METHODS, TECHNIQUES AND SEQUENCES OR PROCEDURES TO PERFORM THE WORK. THE SUPERVISION OF THE WORK IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR. 5. DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION , WHERE CONDITIONS ARE NOT SPEFICALLY SHOWN, THE STANDARD DETAILS CONTAINED IN THE ENGINEER OF RECORD DETAIL SHEETS SHALL BE USED. 6. LOADING APPLIES TO THE STRUCTURE DURING THE PROCESS OF CONSTRUCTION SHALL NOT EXCEED THE SAFE LOAD CARRYING CAPACITY OF THE STRUCTURAL MEMBERS. THE LIVE LOAD USED IN THE DESIGN OF THIS STRUCTURE ARE INDICATED IN THE "DESIGN CRITERIA NOTES". DO NOT APPLY ANY CONSTRUCTION LOADS UNTIL THE STRUCTURAL FRAMING IS PROPERLY CONNECTED TOGETHER AND UNTIL ALL TEMPORARY BRACING IS IN PLACE. 7.GARAGE TO LIVING DOOR TO BE SOLID w/ 20 MINUTE FIRE RATING & SELF CLOSING HINGES. 8. GARAGE TO DWELLING SEPARATION TO HAVE 12" GYPSUM BOARD ON GARAGE SIDE WALLS & 58" TYPE "X" ON CEILINGS w/ HABITABLE ROOMS ABOVE PER FBC 2020 R302.6. 9. WALL SECTIONS 4 FOOT OR GREATER IN LENGTH w/ VERTICAL REBAR IN A FILLED CELL AT EACH END SHALL BE CONSIDERED A SHEAR WALL. FILLED CELLS ARE REQUIRED w/ VERTICAL #5 REBAR ON EACH SIDE OF WINDOWS, DOORS & OPENINGS ALSO AT ALL CORNERS & UNDER ALL GIRDER TRUSSES & BEAMS. 4. SOFFITS SHALL BE CAPABLE OF RESISTING THE DESIGN PRESSURES SPECIFIED IN TABLE R301.2 (2) (2) . FOR HALLS SECTION R103.1 5. ENTRY LANAI CEILING SPECIFICATION OPTIONS: a) 12" SAG RESISTANT GYPSUM BOARD OVER 1"x4" P.T. FURRING STRIPS NAILED @ 16" O.C. w/ (2) 8d NAILS EACH TRUSS b) 12" NOMINAL PLYWOOD OR OSB FASTENED w/ 8d NAILS 6" O.C. OR 38" x 1 12" STAPLES 4" O.C. c) 58" SAG RESISTANT EXTERIOR DRYWALL. 15. ENGINEER OF RECORD MUST REVIEW & APPROVE TRUSS PLANS PRIOR TO THE START OF ANY CONSTRUCTION. FOUNDATION, BEARING WALLS, BEAMS, POSTS & TRUSS CONNECTORS ARE SUBJECT TO CHANGE BASED ON FINAL TRUSS PLANS RAFTER / TRUSS SPACING 24" O.C. ROOF UNDERLAYMENT APPLICATION REFER TO 2020 FLORIDA BUILDING CODE-RESIDENTIAL, 7TH EDITION SECTION 905.1.1 FOR ROOF UNDERLAYMENT. UNDERLAYMENT FOR ROOF SLOPES 2:12 AND GREATER SHALL CONFORM TO APPLICABLE STANDARDS LISTED IN THE CHAPTER. WIND SPEED 115 mph 120 mph 130 mph 140 mph 150 mph 160 mph 170 mph 180 mph MIN. SHEATHING THICKNESS, INCHES (PANEL SPAN RATING) EXPOSURE B 7/16 (24/16) MIN. SHEATHING THICKNESS, INCHES (PANEL SPAN RATING) EXPOSURE C MIN. SHEATHING THICKNESS, INCHES (PANEL SPAN RATING) EXPOSURE D 7/16 (24/16) 7/16 (24/16) 7/16 (24/16) 7/16 (24/16) 7/16 (24/16) 15/32 (32/16) 15/32 (32/16) 15/32 (32/16) 19/32 (40/20) 19/32 (40/20) 19/32 (40/20) 19/32 (40/20) 19/32 (40/20) 19/32 (40/20) 19/32 (40/20) 19/32 (40/20) 19/32 (40/20) 19/32 (40/20) 19/32 (40/20) 19/32 (40/20) 23/32 (48/24) 23/32 (48/24) 23/32 (48/24) FBC 2020 7th EDITION TABLE R803.2.2 MIN. ROOF SHEATHING THICKNESS RAFTER / TRUSS SPACING 24" O.C. WIND SPEED 115 mph 120 mph 130 mph 140 mph 150 mph 160 mph 170 mph 180 mph FBC 2020 7th EDITION TABLE R803.2.3.1 MIN. ROOF SHEATHING ATTACHMENT E F EXPOSURE B RAFTER / TRUSS SG = 0.42 EXPOSURE C EXPOSURE D RAFTER / TRUSS SG = 0.49 RAFTER / TRUSS SG = 0.42 RAFTER / TRUSS SG = 0.49 RAFTER / TRUSS SG = 0.42 RAFTER / TRUSS SG = 0.49 E F E F E F E F E F E F E F 6 6 6 12 6 6 6 6 6 6 6 6 6 6 6 12 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 4 4 6 6 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 46 6 6 6 6 6 6 6 6 6 4 4 4 4 4 4 6 6 6 6 6 6 3 3 3 3 6 6 4 4 4 4 3 3 3 3 3 3 E = NAIL SPACING ALONG PANEL EDGES (INCHES) F = NAIL SPACING ALONG INTERMEDIATE SUPPORTS IN THE PANEL FIELD (INCHES) a) FOR SHEATHING LOCATED A MIN. OF 4 FT. ON EA. SIDE OF RIDGES & HIPS, NAIL SPACING IS PERMITTED TO BE 6" O.C. ALONG PANEL EDGES & 6" O.C. ALONG INTERMEDIATE SUPPORTS IN PANEL FIELD. b) WHERE RAFTER / TRUSS SPACING IS LESS THAN 24 IN. O.C., ROOF SHEATHING FASTENING IS PERMITTED TO BE IN ACCORDANCE WITH THE AWC WFCM OR THE AWC NDS. TRUSS CONNECTION NOTES: TRUSS TO MASONRY w/ UPLIFT UP TO 1,810# USE (1) SIMPSON HETA20 OR EQ. U.N.O. TRUSS TO MASONRY w/ UPLIFT FROM 1,811# TO 2,365# USE (2) SIMPSON HETA20 OR EQ. U.N.O. GIRDER TO MASONRY USE (2) SIMPSON HETA20 OR EQ. UNLESS NOTED OTHERWISE TRUSS TO WOOD w/ UPLIFT UP TO 1,310# USE (1) SIMPSON HTS20 OR EQ. U.N.O. TRUSS TO WOOD w/ UPLIFT FROM 1,311# TO 2,620# USE (2) SIMPSON HTS20 OR EQ. U.N.O. ***IF HETA20 IS MISSED OR SKIPPED ON MASONRY, (2) HTSM20 MAY BE USED. NOTES: 1. APPLY SOLID BEAD OF ROOF MASTIC JUST ABOVE THE ROOF JACK. 2. SLIDE STORM COLLAR DOWN MAKING SURE THE COLLAR IS COMPLETELY SEATED IN MASTIC & THERE ARE NO VOIDS. 3. WHEN COLLAR IS IN FINAL POSITION APPLY FINAL BEAD OF MASTIC AROUND TOP OF STORM COLLAR TOP & SIDES OF FLASHING UNDER ROOF SOLID ROOF MASTIC BOTTOM OF FLASHING OVER ROOFING STORM COLLAR ROOF JACK ONLY BOTTOM FLANGE NAILS EXPOSED VENT PIPE PENETRATION SCALE: N.T.S. 4 5 2n 3e 1 2e 5 5 5 3e 4 3 ROOF PLAN NOTES 1. MINIMUM PRE-FABRICATED ROOF TRUSS DESIGN LOADS TO BE: TOP CHORD LIVE LOAD: 20 P.S.F. TOP CHORD DEAD LOAD: 15 P.S.F. BOTTOM CHORD: 10 P.S.F. TOTAL OF 45 P.S.F. 2. TRUSS ENGINEER IS RESPONSIBLE FOR THE DESIGN OF TRUSS SYSTEM, ROOF FRAMING PLAN & MUST PROVIDE ENGINEERING FOR ALL TRUSSES, TRUSS TO TRUSS CONNECTORS, BEAM BUCKETS/HANGER & UPLIFT DESIGN LOADS. ALL OF WHICH SHALL BE CLEARLY & COMPLETELY SPECIFIED ON TRUSS MANUFACTURER'S ENGINEERING DOCUMENTS. 3. ALL FLASHING & EAVE METAL TO BE 26 GUAGE, G-90 GALV. STEEL. FLASHING TO BE INSTALLED AT ALL WALL/ ROOF INTERSECTIONS, GUTTERS (IF APPLICABLE) WHEREVER THERE IS A CHANGE IN ROOF SLOPE / DIRECTION EXCEPT HIP & RIDGE JUNCTIONS & ALL AROUND ROOF OPENINGS.1 2e 1 2r 2r 3 1 2e 1 1 2e 2e 1 3 2r 1 2r 1 2e 2e 3e 2n 3r 2n 3e DESIGN WIND PRESSURES: REFER TO FIG R301.2(7) COMPONENT AND CLADDING PRESSURE ZONES (2020 FBC-R) NOTE: ALL GABLE ENDS TO BE NAILED 4" O.C. @ ALL EDGES, BLOCKING, SUPPORT, FIELD, ETC.3r 2r 2r2r2e 2e 2e 2r 2r 2e 2e 2e 2r HIP ROOF GABLE ROOF HIP ROOF 2n 3r 3r 2r THE ENGINEER OF RECORD MUST REVIEW AND APPROVE TRUSS PLANS PRIOR TO THE START OF ANY CONSTRUCTION. FOUNDATION, BEARING WALLS, BEAMS, POSTS & TRUSS CONNECTORS ARE SUBJECT TO CHANGE BASED ON FINAL TRUSS PLANS SCALE: AS PER PLAN REV 1: PROJECT #: XX XXX XX DRAWN BY: BILL S. SHEET NUMBER: SHEET TITLE: STATE OFLICENSE FLOR I D ACRAIGE.GUNDERS O NPROF ESSIONA L E N GINEERSTATE OF No. 60102LICENSE FLOR I D ACRAIGE.GUNDERS O NPROF ESSIONA L E N GINEERCraig E. Gunderson, P.E. #60102 FloridaEngineering, LLC4161 TAMIAMI TRAIL UNIT 101PORT CHARLOTTE, FL 33952PH. 941-391-5980FAX 941-979-8195I HEREBY CERTIFY AS THE BUILDING DESIGN ENGINEER OFRECORD, THAT THE BUILDING DESIGN AS SHOWN ON THESEPLANS AND AS ACCOMPANIED BY DESIGN & SUPPORT DOCUMENTSCONFORMS TO THE 2020 7th EDITION FLORIDA BUILDING CODE.THIS CERTIFICATION DOES NOT INCLUDE ROOF TRUSSCOMPONENTS OF WHICH THE TRUSS DESIGN ENGINEER IS THEENGINEER OF RECORD.THIS PLAN HAVE BEEN PREPARED IN COMPLIANCE WITH THE 20207th EDITION FLORIDA BUILDING CODE WITH SUPPLEMENTS.ALL THE DESIGN AND DETAILS ON THIS PLAN ARE THE PROPERTY OF FLORIDA ENGINEERING LLC, AND SHALL NOT BE USED, COPIED OR REPRODUCED WITHOUT THE WRITTEN PERMISSION OF FLORIDA ENGINEERING LLC.S:\FE Structural\Template Roll Out\Residential DetailsLAST SEEN:-3/9/2021 10:42 AM DRAWN BY: BILL S.STRUCTURAL DETAILSREV 2: REV 3: REV 4: REV 5: REV 6: S-8 APPLICABLE CODES : 2020 FLORIDA BUILDING CODE , 7th EDITION2020 FLORIDA BUILDING CODE , 7th EDITION, BUILDING2020 FLORIDA BUILDING CODE , 7th EDITION, EXISTING BUILDING2020 FLORIDA BUILDING CODE , 7th EDITION, MECHANICAL2020 FLORIDA BUILDING CODE , 7th EDITION, PLUMBING2020 FLORIDA BUILDING CODE , 7th EDITION, FUEL GAS2020 FLORIDA BUILDING CODE , 7th EDITION, ACCESSIBILITY CODE 2020 FLORIDA BUILDING CODE , 7th EDITION, ENERGY CONSERVATION 2017 NATIONAL ELECTRIC CODE, NFPA 702018 NFPA 1 CODE / FFPC 6TH EDITION2018 NFPA 101-LIFE SAFETY CODE DETAILS & NOTES 6 6 6 Where the sheathing thickness is 15/32 inches and less, sheathing shall be fastened with ASTM F1667 RSRS-01 (23/8" × 0.113") nails. Where the sheathing thickness is greater than 15/32 inches, sheathing shall be fastened with ASTM F1667 RSRS-03 (21/2" × 0.131") nails or ASTM F1667 RSRS-04 (3" × 0.120") nails. RSRS-01, RSRS-03 and RSRS-04 are ring shank nails meeting the specifications in ASTM F1667. STEP 1: INSTALL SHEET OF MOISTURE BARRIER @ BOTTOM OF OPENING STEP 2: INSTALL BARRIER MEMBRANE ON SILL OF ROUGH OPENING & ON THE MOISTURE BARRIER, LAP UP THE JAMBS MIN. 4" STEP 3: COMPLETELY SEAL CORNER BY ALLPYING A 2" STRIP OF BARRIER MEMBRANE DIAGONALLY AS SHOWN STEP 4: WRAP MOISTURE BARRIER AROUND JAMBS OVERLAPPING BARRIER MEMBRANE 2" SLIDE HEAD FLASHING UNDER TOP SHEET STEP 1 STEP 2 STEP 3 STEP 4 NOTES: 1. PREPARE OPENING PRIOR TO THE INSTALLATION OF THE WINDOW OR MECHANICAL EQUIPMENT. COORDINATE INSTALLATION w/ OTHER SUBTRADES 2. PROVIDE MOISTURE BARRIER & OTHER ASSOCIATED TRIM & ACCESSORIES. 3. PROVIDE FLASHING @ SILL TO DRAIN WATER TO THE EXTERIOR. ROUGH OPENING PREPARATION SCALE: N.T.S. FRAMED BEARING WALL (INTERIOR/EXTERIOR) SCALE: N.T.S. A34 A34 HEADER SEE TRUSS LAYOUT FOR UPLIFT CONNECTORS USE 2x WOOD BLOCKING @ MID-HEIGHT w/ (2) 16d NAILS EA. CONNECTION OR (1) ROW @ EA. PLYWOOD JOINT FOR WALLS OVER 8'-0" IN HEIGHT IF PLYWOOD IN 8 FT. WALLS IS RUNNING VERTICAL, BLOCKING NOT REQ'D. UNLESS NOTED ON PLANS, SEE **EXTERIOR WALL SHEETING NOTE** PRE-ENG. TRUSS TYP.DOUBLE 2x TOP PLATE (SEE GENERAL NOTE #4) SIMPSON SP4 (2x4 STUDS) OR SP6 (2x6 STUDS) @ MASONRY: 1"x4" P.T. & (1) 2"x4" or (1) 2"x4' P.T. MASONRY WALL SIMPSON LSTA24 OR EQ. FULL LENGTH WALL STUDS w/ 16d NAILS 16" O.C. KING STUDS (2) JACK STUDS NAILED TOGETHER w/ 16d NAILS 8" O.C. SIMPSON HTT5 OR EQUIV. ATTACH w/ 12" WEDGE ANCHOR OR "J" BOLTS EMBEDDED2x4 OR 2x6 P.T. BOTTOM PLATE CUT BACK P.T. BTM PLATE 2" TYP. NO CONNECTOR REQ'D @ WINDOW OR DOOR OPENINGS ATTACH FRAME WALLS TO MASONRY w/ 316" x 3 34" TAPCONS @ 16" O.C. OR 12" WEDGE ANCHORS 32" O.C. MAX. SIMPSON SP2 OR EQUIV. MAY BE USED INSTEAD OF SP4 OR SP6 SIMPSON SP1 OR EQUIV. MAY BE USED INSTEAD OF SP4 OR SP6 SIMPSON HTT5 OR EQUIV. SPLICE WITH10D NAILS NOTE SCHEDULE #1 1/2" X 5" TITEN HD ANCHOR BOLT W/ 2" WASHER @ 6" FROM ALL CORNERS & OPENINGS, & 32" O.C. MAX. #2 SIMPSON SP4 @ BOTTOM OF ALL FULL LENGTH & JACK STUDS @ ALL DOOR/ WINDOW OPENINGS #3 SIMPSON SP4 @ TOP & BOTTOM OF FULL LENGTH STUDS @ 32" O.C. #4 SIMPSON SP4 @ TOP OF ALL FULL LENGTH STUDS @ ALL DOOR/ WINDOW OPENINGS #5 CONNECT ALL JACK STUDS TO HEADER W/ SIMPSON LSTA12 @ ALL DOOR/ WINDOW OPENINGS #6 CONNECT DBL TOP PLATE TO HEADER W/ SIMPSON SP4 @ 16" FROM EACH END, & 32" O.C. MAX. FULL LENGTH/ JACK STUD SCHEDULE DOUBLE TOP PLATE SPLICE NAILING REQUIREMENT: (2) 10D NAILS EACH SIDE OF SPLICE SPLICE TO BE STAGGERED MIN OF 4' FROM ANY OTHER SPLICE PLATES TO BE NAILED TOGETHER 16" OC MIN WITH 10D NAILS OPENING WIDTH 1'-0" TO 4'-0" 4'-1" TO 6'-0" 6'-1" TO 9'-0" 9'-1" TO 12'-0" (1) JACK STUD EACH END, (2) FULL LENGTH STUD EACH END (1) JACK STUD EACH END, (2) FULL LENGTH STUDS EACH END (2) JACK STUDS EACH END, (3) FULL LENGTH STUDS EACH END (3)JACK STUDS EACH END, (3) FULL LENGTH STUDS EACH END Frame 2x4-Bearing Wall-Header Schedule N.T.S. NOTE: DBL 2 x12 HEADER MAX. SPAN = 12'-1" ALL OTHER SPANS SHALL BE SPECIFIED NTS 1. THE HEADER STUD SHALL NOT BE REQUIRED IF THEHEADER IS SUPPORTED BY A SUITABLE FRAMINGANCHOR. OR SIMPSON SYSTEM IS INSTALLED, CONNECTORS INDICATED IN THIS DETAIL ARE NOT REQUIRED. 2. IF GO BOLT OR PRO BOLT OR TIE MAX ANCHOR WALL HEIGHTUNSUPPORTED 10' OR LESS SPACINGSTUD THAN 10'GREATER 12 INCHES 16 INCHES 24 INCHES 12 INCHES 16 INCHES 24 INCHES MAXIMUM HEADER SPAN (FEET) 4'6' 9'12'15'18' 1 1 2 3 3 3 NUMBER OF FULL LENGTH STUDSAT EACH END OF HEADER 5 4 3 3 2 3 2 2 1 2 1 2 2 2 2 2 2 2 3 3 2 3 2 3 4 3 2 3 2 3 5 4 3 3 2 3 SUPPORTING END OF HEADERNUMBER OF HEADER STUDS C DBL. TOP PLATETRUSSES HEADER A CCRIPPLF STUDS HEADER STUDS A TYPICAL CONNECTOR LENGTHFULL STUDS BB NO CONNECTOR REQUIRED UPLIFTLOCATIONSTRAP SIMPSON MSTA (fIat strap) 2x4 AND 2x6 WALL A A A A 18 16 10 14 1370 1215 760 1065 SIMPSON SP4 2x4 WALL 1240 1360 735 FASTENERS10d x 1 12" NAILS B,C 6 10 12 B,CB,C SIMPSON SPH4 2x6 WALL 1240 1360 735B,C 6 10 12 B,CB,C UPLIFTLOCATIONSTRAPFASTENERS10d x 1 12" NAILS SIMPSON SP6 SIMPSON SPH6 SHOWN OR SUBSTITUTED WITH ALL CONNECTORS MAY BE AS EQUAL OR GREATER CONNECTORS REQUIREMENTS FOR OPENINGS MINIMUM STUD & HEADER SCALE: AS PER PLAN REV 1: PROJECT #: XX XXX XX DRAWN BY: BILL S. SHEET NUMBER: SHEET TITLE: STATE OFLICENSE FLOR I D ACRAIGE.GUNDERS O NPROF ESSIONA L E N GINEERSTATE OF No. 60102LICENSE FLOR I D ACRAIGE.GUNDERS O NPROF ESSIONA L E N GINEERCraig E. Gunderson, P.E. #60102 FloridaEngineering, LLC4161 TAMIAMI TRAIL UNIT 101PORT CHARLOTTE, FL 33952PH. 941-391-5980FAX 941-979-8195I HEREBY CERTIFY AS THE BUILDING DESIGN ENGINEER OFRECORD, THAT THE BUILDING DESIGN AS SHOWN ON THESEPLANS AND AS ACCOMPANIED BY DESIGN & SUPPORT DOCUMENTSCONFORMS TO THE 2020 7th EDITION FLORIDA BUILDING CODE.THIS CERTIFICATION DOES NOT INCLUDE ROOF TRUSSCOMPONENTS OF WHICH THE TRUSS DESIGN ENGINEER IS THEENGINEER OF RECORD.THIS PLAN HAVE BEEN PREPARED IN COMPLIANCE WITH THE 20207th EDITION FLORIDA BUILDING CODE WITH SUPPLEMENTS.ALL THE DESIGN AND DETAILS ON THIS PLAN ARE THE PROPERTY OF FLORIDA ENGINEERING LLC, AND SHALL NOT BE USED, COPIED OR REPRODUCED WITHOUT THE WRITTEN PERMISSION OF FLORIDA ENGINEERING LLC.S:\FE Structural\Template Roll Out\Residential DetailsLAST SEEN:-3/9/2021 10:42 AM DRAWN BY: BILL S.STRUCTURAL DETAILSREV 2: REV 3: REV 4: REV 5: REV 6: S-9 DETAILS & NOTES