HomeMy WebLinkAboutOleaner-3-Garage 01-26-22-2022 E-1GFCIGFCIGFCIGFCIGFCIGFCI GFCIGFCIGFCIGFCIGFCI J WPWP34443333 3 3334 444443WPWPGFCIGFCIT GFCIGFCIGFCIGFCI GFCIWPSUSPENDED AIR HANDLER 2' - 6"8' - 2"2' - 6"2' - 6"7' - 6 1/2"2' - 6"5' - 10"7' - 0"2' - 6"8' - 2"2' - 6" 2' - 8"8' - 3"2' - 8"3' - 0"7' - 5 1/2"3' - 0"6' - 8 3/4"6' - 8 3/4"2' - 6"4' - 4 1/2"2' - 6" Service-Disconnect 240V WH Service-Disconnect 240V 4" 4" VP 4" VP 4"1' - 6"1' - 6" 2' - 4"2' - 4"2' - 0"2' - 0"2' - 0" 4" VP 4" VP 60" 60" 60" 60" 60" 60" 60" 60" E-1 2 REFER TO CALLOUT FOR ISLAND RECEPTACLES 120V HOOD VENT VTR F F F F VP 2' - 0"2' - 4"FAN W/LIGHT KIT FAN W/LIGHT KIT METER CAN 240V ELECTRICAL CONTRACTOR TO INSTALL 1/2" CONDUIT FOR COLUMN LIGHTS PRIOR TO SLAB & COLUMN POURS RECESSED IRONING BOARD OUTLET INSIDE POOL & IRRIGATION SUB PANEL 100A SD SD SD SD SD SD SD SD BOX TO HOLD 150LBS. BOX TO HOLD 150LBS. COUNTER TOP REC. UNDER CABINET REC. DW & DISPOSAL DISPOSAL SWITCH INSIDE CABINET UNDER CABINET REC. FOR MICROWAVE DRAWER 4' - 0"9' - 8"~ RECEPTICALS IN BATH ARE ARE TO BE 46" A.F.F. ~ PROVIDE ARC FAULT PROTECTION IN ALL LIVING SPACES PER NEC 210.8 ~ T.V. & PHONE JACK PRECISE LOCATIONS T.B.D. BY CONTRACTOR ~ ALL MOTORS/PUMPS TO BE INSTALLED ON VIBRATION DAMPENERS & AFCI PER NEC ~ ALL WP OUTLETS TO BE GFCI PER NEC 210.8 ~ DISHWASHER RECEPTICAL TO BE AFCI/GFCI PER NEC 210.8 ~ ALL RECEPTICALS WITHIN 6 FEET OF A WET AREA MUST BE AFCI/GFCI ~ ALL RECEPTICALS ARE TO BE TAMPER PROOF ~ BATHROOM LIGHT FIXTURES TBD BY CONTRACTOR ON SITE ~ RECESSED LAMPS TO BE L.E.D. & MINIMUM 1000 LUMENS ELECTRICAL LEGEND SWITCH 3 WAY SWITCH 4 WAY SWITCH DIMMER SWITCH WALL SCONCE DUPLEX RECEPTICAL SWITCHED RECEPTICAL 220V RECEPTICAL RECESSED VAPOR PROOF L.E.D. LIGHT SMOKE & CARBON MONOXIDE DETECTORPUSH BUTTON (1) CAT 6 EXHAUST FAN (LESS THAN 2.0 SONES)RECESSED L.E.D. CAN LIGHT PHONE & CABLE OUTLET (1)RG-6 & (1)CAT 6 SURFACE MOUNTED LIGHT CEILING FAN PRE-WIRE GRAPHIC IS 60" FAN WALL MOUNTED LIGHT L.E.D. FIXTURE 1' x 4' ENCLOSED L.E.D. LIGHT L.E.D. FLOOD LIGHTS DOOR CHIME THERMOSTAT VP T D 4 3 SD F B QUAD. RECEPTICAL SINGLE RECEPTICAL WEATHER PROOF GFCI RECEPTICAL GROUND-FAULT CIRCUIT-INTERRUPTER PROTECTION FOR PERSONNEL SHALL BE PROVIDED AS REQUIRED IN 210.8(A) THROUGH (F). THE GROUND-FAULT CIRCUIT INTERRUPTER SHALL BE INSTALLED IN A READILY ACCESSIBLE LOCATION. ALL 125-VOLT THROUGH 250-VOLT RECEPTACLES INSTALLED IN THE LOCATIONS SPECIFIED IN 210.8(A)(1) THROUGH (A)(11) AND SUPPLIED BY SINGLE-PHASE BRANCH CIRCUITS RATED 150 VOLTS OR LESS TO GROUND SHALL HAVE GROUND-FAULT CIRCUIT-INTERRUPTER PROTECTION FOR PERSONNEL. ALL 125-VOLT THROUGH 250-VOLT RECEPTACLES SUPPLIED BY SINGLE-PHASE BRANCH CIRCUITS RATED 150 VOLTS OR LESS TO GROUND, 50 AMPERES OR LESS, AND ALL RECEPTACLES SUPPLIED BY THREE-PHASE BRANCH CIRCUITS RATED 150 VOLTS OR LESS TO GROUND, 100 AMPERES OR LESS, INSTALLED IN THE LOCATIONS SPECIFIED IN 210.8(B)(1) THROUGH (B)(12). SURGE PROTECTION TO THE SERVICE IS MANDATORY PER NEC 230.67 TYPE 1 OR TYPE 2 SPD IS ACCEPTABLE ELECTRICAL NOTES: UNDERGROUD UTILITIES CONNECTION BY OTHERS F.P.L. WILL DETERMINE IF OVERHEAD OR UNDERGROUND SERVICE #2 COPPER GROUND WIRE TO FOOTER STEEL AND COPPER WATER PIPE BRANCH OFF CIRCUITS AS REQUIRED P.V.C. NIPPLE WITH (4) 350 MCM CU (2) 250 MCM CU METER BOX HEATER/A.C. DISC. AS PER EQUIPMENT DEMAND 120/240V 1 sqft.-3W 400 AMP 40 CIRC. WITH MAIN BREAKER ALL GROUNDING RODS TO BE MIN. 3/4" X 10' COPPER MIN. QTY. 3 ScaleVILLADELTA CONSTRUCTION CORP. LLC CRC 058035THE DESIGN PROFESSIONAL OF RECORD (ENGINEER AND/OR ARCHITECT) ASSUMES ALL RESPONSIBILITY OF THE SPECIFICATIONS CONTAINED HERE IN. IT IS THE CLIENT'S AND/OR CONTRACTOR'S RESPONSIBILITY TO VERIFY THE FINAL PLANS AND MEASUREMENTS. ALL CHANGES FROM THIS POINT FORWARD WILL NEED A SIGNED CHANGE ORDER BEFORE ANY ADDITIONAL WORK OR MODIFICATIONS WILL BE MADE. ALL WRITTEN CHANGE ORDERS SUPERCEED THE DRAWINGS. THE DRAWINGS ARE CONCEPTUAL DESIGNS AND MAY VARY FROM THE FINISHED PROUCT. THESE DRAWINGS ARE THE PROPERTY OF THE DISIGNER AND SHALL NOT BE REPRODUCED, MODIFIED OR ALTERED WITHOUT PRIOR WRITTEN CONSENT. THESE DRAWINGS WILL REMAIN THE PROPERTY OF THE DESIGNER EVEN IF THEY ARE NOT USED IN THE CONSTRUCTION OF THIS PROJECT. COPYRIGHTT 2016 PRONTO PLANS, L.L.C. ___________________________________CLIENT'S APPROVAL DATE As indicated 1/26/2022 10:01:03 PM E-12401 Noble Oaks LaneFt. Pierce, FL 34981Dudley ResidenceRev. #DescriptionDate 1/4" = 1'-0"1First Floor Electrical Lighting 1/2" = 1'-0"2 First Floor Electrical Kitchen Island Receptacles 1/4" = 1'-0" Electrical Riser 400A N.T.S.