Loading...
HomeMy WebLinkAboutDUCT DRAWINGJob #: 1622 Performed by Chris Bateman for: Pellaquila Residence 5302 Seagrape Dr Fort Pierce, FL 34982 Air Calcs, LLC 7550 Hidden Hammock Ln Vero Beach, FL 32966 Phone: 772.800.8413 vickilynne@aircalcs.com Scale: 1 : 123 Page 1 Right-Suite® Universal 2021 21.0.10 RSU29066 2021-Nov-18 10:11:19 ...AC\5302 Seagrape Dr PSL Prop.rup N Level 1 Garage Laundry Bed 2 BathBath 2 Hall Bed 3 Bed 4 Foyer GR Pantry Kitchen DR Master Bath Hers His Master Bed H/W DUCTS IN THE GARAGE AND DUCTS PENETRATING THE WALLS OR CEILINGS SEPARATING THE DWELLING FROM THE GARAGE SHALL BE CONSTRUCTED OF A MINIMUM NO. 26 GAGE (0.48 MM) SHEET STEEL, 1 INCH MINIMUM RIGID NONMETALLIC CLASS 0 OR CLASS 1 DUCT BOARD, OR OTHER APPROVED MATERIAL AND SHALL HAVE NO OPENINGS INTO THE GARAGE 100 CFM 6" Duct 6"Exhaust Vent 50 CFM 4" Duct 4"Exhaust Vent 50 CFM 4" Duct 4"Exhaust Vent F F F 12 x 8 151 cfm 12 x 12 151 cfm 12 x 12 194 cfm 8 x 8 52 cfm 8 x 8 7 cfm 10 x 10 192 cfm 12 x 12 145 cfm 8 x 4 46 cfm 16 x 16 252 cfm 10 x 10 192 cfm 16 x 16 8 x 8 113 cfm 8 x 8 113 cfm 12 x 12 217 cfm12 x 12 217 cfm 8 x 4 25 cfm 30 x 18 970 cfm 8 x 4 1 cfm 12 x 8 145 cfm 12 x 8 194 cfm 8 x 8 125 cfm 14 " 7 " 9 " 4 " 4 " 7 " 4 " 7 " 6 " 6 " 7 "7 " 4 " 12 " 4 " 16 " 6 " 9 " 7 " 6 " 18 " 7 " 8 " 7 "