HomeMy WebLinkAboutUNDERLAYMENT FL11842_R8_II_2_PS_EVALREPORTThis item has been electronically signed and sealed by
James L. Buckner, P.E., on this date using a Digital Signature.
Printed copies of this document are not considered signed
and sealed, and the signature must be verified on any
electronic copies.
2020.09.17 13:23:17 -04'00'
Specialty Structural Engineering
CBUCK, Inc. dba CBUCK Engineering
Phone: (561) 491-9927 · Email: cbuck@cbuckinc.net · Website: www.cbuckinc.net
Business: 1374 Community Dr., Jupiter, FL 33458 · Corp/Mailing: 2637 E. Atlantic Blvd, #34069, Pompano Beach, FL 33062
CBUCK, Inc. Certificate of Authorization #8064
CBUCK Engineering
Evaluation Report
“Peel & Seal™”
Roof Underlayment
Manufacturer:
MFM Building Products Corp.
525 Orange Street
Coshocton, Ohio 43812
(740) 622-2645
for
Florida Product Approval
# FL 11842.2 R8
Florida Building Code 7th Edition (2020)
Method: 1 - D
Category: Roofing
Sub - Category: Underlayment
Product: “Peel & Seal™” Description: Self-Adhered Underlayment
Prepared by:
James L. Buckner, P.E., SECB
Florida Professional Engineer # 31242
Florida Evaluation ANE ID: 1916
Project Manager: Diana Galloway
Report No. 20-229-P&S-ER
(Revises 17-131- P&S-ER, FL11842.1 R4)
Date: 08 / 28 / 20
Contents:
Evaluation Report Pages 1 – 5
FL #: FL 11842.2 R8
Date: 08 / 28 / 20
Report No.: 20-229-P&S-ER
Page 2 of 5
Specialty Structural Engineering
CBUCK, Inc. Certificate of Authorization #8064
CBUCK Engineering
Manufacturer: MFM Building Products Corp.
525 Orange Street
Coshocton, Ohio 43812
(740) 622-2645
http://www.mfmbp.com/
Product Name: “Peel & Seal™”
Product Category: Roofing
Product Sub-Category Underlayment
Compliance Method: State Product Approval Rule 61G20-3.005 (1) (d)
Product Description: 45-mils thick (nominally), self-adhering, foil-faced, non-reinforced membrane
with rubberized asphalt, and a release liner.
Roll size: 36” wide x various lengths
Surface colors: Aluminum, Almond, Granite Gray & White
Product Material /
Standards:
Material Type: Styrene Butadiene Styrene (SBS)
Material shall comply with ASTM D 1970 per Florida Building Code FBC 7th Edition
(2020), Chapter 15.
Substrate(s): Plywood Deck
(Design of support is outside the scope of this evaluation)
Installation: General Installation Instructions:
• Product to be applied directly to a clean dry surface.
• Dust, dirt, oil, grease, moisture, debris and other loose materials or
contaminants must be removed prior to application.
• Check that all nails in deck are not protruding and re-fasten any loose
decking panels.
• Prime Substrate with asphalt base primer.
• Cut the membrane to appropriate length.
• Peel back the release sheet, align the membrane and press into place onto
roof deck.
• Apply with selvedge on upward slope.
• Overlap end laps a minimum of 6”. Side laps must be a minimum of 3”.
• Apply membrane perpendicular to roof slope on slopes ≤ 3:12 and parallel on
slopes > 3:12.
• After installation roll entire surface with a heavy weighted roller. Roll all side
and end laps.
• Store product in the carton in a dry place until ready to use. Keep product
out of direct sunlight.
• Protect membrane from damage during construction.
• Apply membrane only in fair weather when the air, surface and
membrane are at a minimum temperature of: 55° F
FL #: FL 11842.2 R8
Date: 08 / 28 / 20
Report No.: 20-229-P&S-ER
Page 3 of 5
Specialty Structural Engineering
CBUCK, Inc. Certificate of Authorization #8064
CBUCK Engineering
Installation shall comply with this report, applicable code sections of FBC 7th
Edition (2020) (subject to the Limitations and Conditions of Use listed in this
Evaluation Report) and manufacturer’s installation instructions as a
supplemental guide for attachment.
Performance Standards: The product described herein has demonstrated compliance with:
• ASTM D 1970-15a – Specification Self-adhering Polymer Modified
Bituminous Sheet Materials Used as Steep Roof Underlayment for Ice Dam
Protection
Standards Equivalency: The ASTM D 1970-01 standard version used to test the product meets the
prescribed standards in ASTM D 1970-15a standard version adopted by the
Florida Building Code 7th Edition (2020) for use as evaluated in this report.
Code Compliance: The product(s) described herein have demonstrated compliance with the
performance standards listed above as referenced in the current Florida
Building Code.
Evaluation Report Scope: This product has been evaluated in compliance with the building envelope
requirements of the Florida Building Code, as related to the scope section to
Florida Product Approval Rule 61G20-3.001.
Product Limitations and
Conditions of Use:
• Deck shall be in compliance with applicable building code.
• Evaluated for use with approved roof coverings that are mechanically
fastened through the underlayment and is attached to the sheathing or
rafters. Installation shall comply with FBC Section 1507.1.1.
• Minimum slope shall be 2:12 or greater.
• Not to be applied over EPDM rubber or urethane or urethane composite
insulations.
General Limitations and
Conditions of Use:
• Scope of “Limitations and Conditions of Use” for this evaluation:
This evaluation report for “Optional Statewide Approval” contains technical
documentation, specifications and installation method(s) which include
“Limitations and Conditions of Use” throughout the report in accordance with
Rule 61G20-3.005. Per Rule 61G20-3.004, the Florida Building Commission is
the authority to approve products under “Optional Statewide Approval”.
• Option for application outside “Limitations and Conditions of Use”
Rule 61G20-3.005(1)(e) allows engineering analysis for “project specific
approval by the local authorities having jurisdiction in accordance with the
alternate methods and materials authorized in the Code”. Any modification of
the product as evaluated in this report and approved by the Florida Building
Commission is outside the scope of this evaluation and will be the
responsibility of others.
• This report is a building code product evaluation per FLPE rule (FAC) 61G15-36
to comply with Florida product approval rule (FAC) 61G20-3. This evaluation
report is part of the Florida Building Commission approval for the listed code
FL #: FL 11842.2 R8
Date: 08 / 28 / 20
Report No.: 20-229-P&S-ER
Page 4 of 5
Specialty Structural Engineering
CBUCK, Inc. Certificate of Authorization #8064
CBUCK Engineering
related criteria. This report by James Buckner, P.E. and CBUCK Engineering is
not a design certification of code compliance construction submittal
documentation, per FBC section 107, for any individual structure, site specific
or permit design.
• Design of support system is outside the scope of this report.
• Fire Classification is outside the scope of Rule 61G20-3, and is therefore not
included in this evaluation.
• This evaluation report does not evaluate the use of this product for use in the
High Velocity Hurricane Zone code section. (Dade & Broward Counties)
Quality Assurance: The manufacturer has demonstrated compliance of roof panel products in
accordance with the Florida Building Code and Rule 61G20-3.0005 (3) for
manufacturing under a quality assurance program audited by an approved
quality assurance entity through Keystone Certifications, Inc.
Referenced Data: 1. ASTM D 1970-01 Test
By PRI Construction Materials Technologies, Inc.
(FBC Organization ID# TST 1556)
Report No. MFM-005-02-01, Date: 8/29/05
2. ASTM D 1970-01 Test
By PRI Construction Materials Technologies, Inc.
(FBC Organization ID# TST 1556)
Report No. MFM-006-02-01, Date: 8/29/05
3. Equivalency of Test Standard Certification
By James L. Buckner, P.E. @ CBUCK Engineering
(FBC Organization # ANE 1916)
4. Quality Assurance
Keystone Certifications, Inc. (FBC Organization ID# QUA 1824)
MFM Building Products Corp. Licensee #335
5. Certification of Independence
By James L. Buckner, P.E. @ CBUCK Engineering
(FBC Organization # ANE 1916)
FL #: FL 11842.2 R8
Date: 08 / 28 / 20
Report No.: 20-229-P&S-ER
Page 5 of 5
Specialty Structural Engineering
CBUCK, Inc. Certificate of Authorization #8064
CBUCK Engineering
MFM Building Products Corp.
Product Illustrations
Peel & Seal™