Loading...
HomeMy WebLinkAboutUNDERLAYMENT FL11842_R8_II_2_PS_EVALREPORTThis item has been electronically signed and sealed by James L. Buckner, P.E., on this date using a Digital Signature. Printed copies of this document are not considered signed and sealed, and the signature must be verified on any electronic copies. 2020.09.17 13:23:17 -04'00' Specialty Structural Engineering CBUCK, Inc. dba CBUCK Engineering Phone: (561) 491-9927 · Email: cbuck@cbuckinc.net · Website: www.cbuckinc.net Business: 1374 Community Dr., Jupiter, FL 33458 · Corp/Mailing: 2637 E. Atlantic Blvd, #34069, Pompano Beach, FL 33062 CBUCK, Inc. Certificate of Authorization #8064 CBUCK Engineering Evaluation Report “Peel & Seal™” Roof Underlayment Manufacturer: MFM Building Products Corp. 525 Orange Street Coshocton, Ohio 43812 (740) 622-2645 for Florida Product Approval # FL 11842.2 R8 Florida Building Code 7th Edition (2020) Method: 1 - D Category: Roofing Sub - Category: Underlayment Product: “Peel & Seal™” Description: Self-Adhered Underlayment Prepared by: James L. Buckner, P.E., SECB Florida Professional Engineer # 31242 Florida Evaluation ANE ID: 1916 Project Manager: Diana Galloway Report No. 20-229-P&S-ER (Revises 17-131- P&S-ER, FL11842.1 R4) Date: 08 / 28 / 20 Contents: Evaluation Report Pages 1 – 5 FL #: FL 11842.2 R8 Date: 08 / 28 / 20 Report No.: 20-229-P&S-ER Page 2 of 5 Specialty Structural Engineering CBUCK, Inc. Certificate of Authorization #8064 CBUCK Engineering Manufacturer: MFM Building Products Corp. 525 Orange Street Coshocton, Ohio 43812 (740) 622-2645 http://www.mfmbp.com/ Product Name: “Peel & Seal™” Product Category: Roofing Product Sub-Category Underlayment Compliance Method: State Product Approval Rule 61G20-3.005 (1) (d) Product Description: 45-mils thick (nominally), self-adhering, foil-faced, non-reinforced membrane with rubberized asphalt, and a release liner. Roll size: 36” wide x various lengths Surface colors: Aluminum, Almond, Granite Gray & White Product Material / Standards: Material Type: Styrene Butadiene Styrene (SBS) Material shall comply with ASTM D 1970 per Florida Building Code FBC 7th Edition (2020), Chapter 15. Substrate(s): Plywood Deck (Design of support is outside the scope of this evaluation) Installation: General Installation Instructions: • Product to be applied directly to a clean dry surface. • Dust, dirt, oil, grease, moisture, debris and other loose materials or contaminants must be removed prior to application. • Check that all nails in deck are not protruding and re-fasten any loose decking panels. • Prime Substrate with asphalt base primer. • Cut the membrane to appropriate length. • Peel back the release sheet, align the membrane and press into place onto roof deck. • Apply with selvedge on upward slope. • Overlap end laps a minimum of 6”. Side laps must be a minimum of 3”. • Apply membrane perpendicular to roof slope on slopes ≤ 3:12 and parallel on slopes > 3:12. • After installation roll entire surface with a heavy weighted roller. Roll all side and end laps. • Store product in the carton in a dry place until ready to use. Keep product out of direct sunlight. • Protect membrane from damage during construction. • Apply membrane only in fair weather when the air, surface and membrane are at a minimum temperature of: 55° F FL #: FL 11842.2 R8 Date: 08 / 28 / 20 Report No.: 20-229-P&S-ER Page 3 of 5 Specialty Structural Engineering CBUCK, Inc. Certificate of Authorization #8064 CBUCK Engineering Installation shall comply with this report, applicable code sections of FBC 7th Edition (2020) (subject to the Limitations and Conditions of Use listed in this Evaluation Report) and manufacturer’s installation instructions as a supplemental guide for attachment. Performance Standards: The product described herein has demonstrated compliance with: • ASTM D 1970-15a – Specification Self-adhering Polymer Modified Bituminous Sheet Materials Used as Steep Roof Underlayment for Ice Dam Protection Standards Equivalency: The ASTM D 1970-01 standard version used to test the product meets the prescribed standards in ASTM D 1970-15a standard version adopted by the Florida Building Code 7th Edition (2020) for use as evaluated in this report. Code Compliance: The product(s) described herein have demonstrated compliance with the performance standards listed above as referenced in the current Florida Building Code. Evaluation Report Scope: This product has been evaluated in compliance with the building envelope requirements of the Florida Building Code, as related to the scope section to Florida Product Approval Rule 61G20-3.001. Product Limitations and Conditions of Use: • Deck shall be in compliance with applicable building code. • Evaluated for use with approved roof coverings that are mechanically fastened through the underlayment and is attached to the sheathing or rafters. Installation shall comply with FBC Section 1507.1.1. • Minimum slope shall be 2:12 or greater. • Not to be applied over EPDM rubber or urethane or urethane composite insulations. General Limitations and Conditions of Use: • Scope of “Limitations and Conditions of Use” for this evaluation: This evaluation report for “Optional Statewide Approval” contains technical documentation, specifications and installation method(s) which include “Limitations and Conditions of Use” throughout the report in accordance with Rule 61G20-3.005. Per Rule 61G20-3.004, the Florida Building Commission is the authority to approve products under “Optional Statewide Approval”. • Option for application outside “Limitations and Conditions of Use” Rule 61G20-3.005(1)(e) allows engineering analysis for “project specific approval by the local authorities having jurisdiction in accordance with the alternate methods and materials authorized in the Code”. Any modification of the product as evaluated in this report and approved by the Florida Building Commission is outside the scope of this evaluation and will be the responsibility of others. • This report is a building code product evaluation per FLPE rule (FAC) 61G15-36 to comply with Florida product approval rule (FAC) 61G20-3. This evaluation report is part of the Florida Building Commission approval for the listed code FL #: FL 11842.2 R8 Date: 08 / 28 / 20 Report No.: 20-229-P&S-ER Page 4 of 5 Specialty Structural Engineering CBUCK, Inc. Certificate of Authorization #8064 CBUCK Engineering related criteria. This report by James Buckner, P.E. and CBUCK Engineering is not a design certification of code compliance construction submittal documentation, per FBC section 107, for any individual structure, site specific or permit design. • Design of support system is outside the scope of this report. • Fire Classification is outside the scope of Rule 61G20-3, and is therefore not included in this evaluation. • This evaluation report does not evaluate the use of this product for use in the High Velocity Hurricane Zone code section. (Dade & Broward Counties) Quality Assurance: The manufacturer has demonstrated compliance of roof panel products in accordance with the Florida Building Code and Rule 61G20-3.0005 (3) for manufacturing under a quality assurance program audited by an approved quality assurance entity through Keystone Certifications, Inc. Referenced Data: 1. ASTM D 1970-01 Test By PRI Construction Materials Technologies, Inc. (FBC Organization ID# TST 1556) Report No. MFM-005-02-01, Date: 8/29/05 2. ASTM D 1970-01 Test By PRI Construction Materials Technologies, Inc. (FBC Organization ID# TST 1556) Report No. MFM-006-02-01, Date: 8/29/05 3. Equivalency of Test Standard Certification By James L. Buckner, P.E. @ CBUCK Engineering (FBC Organization # ANE 1916) 4. Quality Assurance Keystone Certifications, Inc. (FBC Organization ID# QUA 1824) MFM Building Products Corp. Licensee #335 5. Certification of Independence By James L. Buckner, P.E. @ CBUCK Engineering (FBC Organization # ANE 1916) FL #: FL 11842.2 R8 Date: 08 / 28 / 20 Report No.: 20-229-P&S-ER Page 5 of 5 Specialty Structural Engineering CBUCK, Inc. Certificate of Authorization #8064 CBUCK Engineering MFM Building Products Corp. Product Illustrations Peel & Seal™