Loading...
HomeMy WebLinkAboutSurvey 1-31-22SURVEYOR'S REPORT 1 This Survey shall not be valid unless sealed with an embossed Surveyor's Seal , 2 No underground improvements have been located as part of this Survey. 3 The last field date of this Survey was: 4.6.2010. 4 This Survey was prepared using the Plat of Record only. No other documents were provided and no search of the public records was performed by this office. 5 The Survey shown hereon and prepared this April 19, 2010 was prepared in accordance with the requirement for field accuracy as set forth by the Minimum Technical Standards (61G17-6FAC). 6 By acceptance of this survey all parties agree that the signing surveyor's liability is limited to the amount paid for said Survey. 7 Unless other wise noted all bearing and distances are in accordance with the: record plat and hove been verified by field measurements. See mop for bearing base. 8 Parcel/Lot line locations have been based on found survey control along the I. at PC N_ I012 N m N I .- O Ism 30.00'WM I� 12.0' --- ------ v WM center tine of NE Lobster Road. I o a 9 LEFT BLANK. W 3 0 10 The Legal Description shown hereon was provided by the client and/or his/her W representatives. pq 11 No ownership of fence lines has been determined as part of this Survey., _ O 12 Off set calls to found survey control are relative to the nearest property corner, intersection of lines, point of curvatures (PC)', point of reverse curvatures W `° I (PRC) or other identifiable point. 13 Compliance with local zoning requirements and or with requirements set forth by other State, Public, and/or Private entities has not been verified as part of this Survey. I 14 Elevations shown are in accordance with the North American Vertical Datum a: 1 15 By clients testimony this was revised to show an existing enclosure of an area previously occupied in part by a shed. this does NOT represent a field survey or I cation of walls LEGEND C/E —Covered Entry CAC - Concrete Pad with Air Conditioning. Flood Zone Data derived b scaling Y 9 CBS — Concrete Block Structure methods of the official FEMA Maps and CUP — Corrugated Metal Pipe CPE — Concrete Pad with Pool Equipment limited to the accuracy of such maps. Y F ' CTv - Cable ry Box Flood Zone: X Community #: 120285 Hv -water Cate Valve h HID -fire Hydrontl Pane # : 0278 Suffix: K Date: 2,19.2020' O/L — Overhead utility Line PP — Power Pole TCB — Telephone Communications Box St. — Street Light SSMH - Sanitary Sewer Manhole t PREPARED FOR: UB — utility Box wM - water Meter "x4"Concrete Douglas J. -Leighton, Jn FCM - Found 4, Monument FiP — Found 1' Iron Pipe Angel Oak Mortgage Solutions LLC, Its sucesso Found Iron Pipe with cap 164967' FIPC — Iron Rod FIR —Found 5 and/or assigns as their interest may appear FIRC — Found 15 Iron Rod with cap First American Title Insurance Company, SIRC — Set J5 Iron Rod with Cap IW17357" FIPC — Found 1/2' Iron Pipe with Cap FM — Found Nag Nail FM7 — Found Nag Nail with Tin Tab By: Regina C. Kamer, PSM Florida Registration # FMD — Found Nag Nail with Disk 4363 FN — Found Nall F—Found Nail with Tin Tab FPK —Found PK Nail Kamer � Surveying Inc. LB#7357 PK FPKD — Found PK Nag with Disk FRRS — Found Rail Road Spike /Co — In Pavement Cut Out Prepared For: Douglas J. Leighton, Jr. LEGAL DESCRIPTION Lot 9, Block 73, RIVER PARK - UNIT 9 PART 'A'; according to the Pla thereof, as recorded in Plat Book 14, Pages 31, Public Records of St. Lucie County, Florida. I Lot 10 Block 73 6'Drainage & Utility Easement '18'30"E 110.00' Fence corner o � r —Fence Line— Noi ID 6'Drainoge'j& Utility Easement !o j i - 20.2' 6 9''-p 2 0 he`- F o d' 25' Bu�ing Setback CAR PORT N w Conc. Drive EL. 15.18 J Rim at FIP El.14..02 No ID RMH 11.0 C nc.w I 'i I I u 3.9 11.9, --1-- Newly Enclosed o Area I o ry See NOTE# 15at 4 � -- 48.8 ---------00 ` y m o> 103, wI n z r° Lot 9 Block 73I I I em 23.8.' Building Setback Line to I�L-4-7.5' L— -q--'1 6'Drainage & Utility Easement TCB _ I _ _ N00"18'30 "W 110.00' - 1. 6'Drainage & tility Easement iLot 8 Block 73 NOTE: (This property is in a RS-4 Zoning District.. In accordance witd the L d Development Code,: Chapter VIl Development Code Section 7.04.04 the following property development standards should be adhered to: Front Building Setback 25', RECEIVED Side Building Setback = 7.5', Rear Building Setback = 15' JAN 31 2022 Total _maximum coverage = 309 St.,Lucie County KARNER SURVEYING, INC. Residential & Commercial Surveying Services I 1 2740 SW Martin Downs Blvd #333 Palm City, Florida.-.3499 PHONE: 1-772-288 7206 FAX. 1-772-223 8181i Synv p,N, r u 4;z Sheet Titles .ljl Boundary Survey Sheet Na, 1 OF 1 Draping Name, Proj: SLC_RiverPark1RivParkU9A-73-9 .Scafo,,,a10, Da e, - Drom Dy, Feld ook� or00-1 1001 Job No., Project. f 003-16