Loading...
HomeMy WebLinkAboutblower doorJob Information Builder: DR HORTON Envelope Leakage Test Report (Blower Door Test) R405.4.2.1 Compliance IPermit # Community: CREEKSIDE Lot: 115 IVE_ Unit: "'' "Na" State: FL Air Leakage Test Results Passing results must be 7ACif(50) or less Zip: 1137 x 60 _ 15720.9 = 4.3 Method for calculating building volume: CFM(50) Building Volume ACH(50) Q Retrieved from architectural plans g (j *eode software calculated PASS _ FAI (. Q Field measured and calculated When ACH(50) is less than 3, Mechanical Ventilation installation must be verified by building department. Certification of Test Results v 111s. f fie uuaomg or aweiiing unit shall be tested and verified as having an air11 leakage rate of not exceeding 7 air changes per hour in Climate Zones 1 and 2, 3 air changes per hour in Climate Zones 3 through 8. Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g. (50 Pascals). Testing shall be conducted by wither individuals as defined in Section 553.993(5) or (7), F.S. or individuals licensed as set forth in Section 489.105(3)(f), (g), or (i) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelonP. Testing Company Company Name: SUN SEAL LLC Phone: 321-412-0035 I hereby verify that the above duct leakage testing results are in accordance with the Florida Building Code requirements with the selected compliance path as stated above, either the Prescriptive Method or Performance Method. Date of Test: 02/22/2022 Signature of Tester: Printed Name of Tester: RAULY BAGGETF License/Certification # 5066185 issuing Authority BPI