HomeMy WebLinkAboutCertification For Design Load CompliancePlanning & Development Services Department
Building & Code Regulations Division
2300 Virginia Avenue, Fort Pierce, FL 34982_— (772) 462-1553
Certification for Design Load Compliance
Project Name:
i
Project Address: i 0 iSoi i• O SV
Permit #: I Occupancy Type: Construction Type:
I
INSTRUCTIONS FOR USE:
• This certification must be completed, signed, and sealed by the design professional of record.
• Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following:
o New Residences (single or multi -family)
o Residential Addition
o Any accessory structure requiring a building permit "I L o Any nonresidential structure. } F
1,
*Note: Form not required for interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the local building official. Contact the # above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply)
2014 Building N/A
1. DESIGN CODE: Florida g Code Fifth Edition with 20 Supplements using ASCE 7-10
2. Structure Designed as (check one): X Enclosed Partially Enclosed Open
3. Risk Category: _I X II 111 IV Exposure Category: B X C D
4. Design Wind Veli city 160 mph X ASD LRFD End Zone Width: 6 ft
5. Mean Roof Height 16 ft Roof Pitch: 6 :12 Parapet: N/A ft
6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings):
Zone 1: +�s.3, -30.� Zone 2: +1s.3, -53.5 Zone 3: +1s.3. -7s.1 Zone 4: +33.s, �s.a Zone 5: +33•s, �a.s Garage: +28.4, -3a.7
100 12 30 N/A
7. Design Loads: Floor: PSF Roof/Dead: PSF Roof/Live: Balcony: PSF
' Dock: N/A PSF Deck: N/A PSF Stairs: N/A PSF Fence: N/A PSF Railings: N/A PSF
8. Were Shear Walls Considered For Structure? Yes x Not Applicable Explain Why Not:
Aspect Ratio < 4i1
9. Is A Continuous) Load Path Provided? X Yes Not Applicable Explain Why Not:
10. Design Soil Bearing Pressure: 2500 PSF Soil Test Reports Submitted? Yes
DESIGN PROFESSIONAL CERTIFICATION STATEMENT:
I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to
comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie
County. I also certify that structural elements depicted on these plans provide adequate resistance to the design
forces specified4
-� OA -, �10 52046
Print Name Cert # & Co. Cert Auth.
Nuelle Engineering
>ig re, te, In, d S I 11634 SW Rowena Str, P.S.L., FL 34987
Company Name & Address
Revised 07/G /201