HomeMy WebLinkAboutEnergy Efficiency CodeFORM R405-2014 I
FLORIDA ENERGY EFFICIENCY
CODE FOR BUILDING CONSTRUCTION
Florida Department i f Business and Professional Regulation - Residential. Performance Method
I
Project Name: BISCAYNE UK, ANDE_eCLASSIC_MDW 53
Builder Name: GHO Homes
Street: 2672 Conifer Dr
Permit Office:
City, State, Zip: Ft Pierce , FL 34953
Permit Number:
Owner: GHO Homes
Jurisdiction:
Design Location: FL, Fort PiercI e
County:: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types (1976.6 sgft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Int Insul, Exterior R=4.1 1748.40 ft2
b. Frame - Steel, Adjacent
R=11.0 227.11 ft2
3. Number of units, if multiple famil 1
c. N/A
R= ft2
4. Number of Bedrooms 2
d. N/A
R= ft2
10. Ceiling Types (1954.0 sqft.)
Insulation Area
5. Is this a worst case? No
a. Under Attic (Vented)
R=30.0 1954.00 ft2
6. Conditioned floor area above grade (ft2) 1954
b. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
c. NIA
2
R= ft
1
11. Ducts
R ft2
7. Windows(255.3 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Main
6 394.2
a. U-Factor: Dbl, U 0.49 164.31 ft2
SHGC: SHGC=0.24
b. U-Factor: Dbl, UL0.50 72.00 ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.25
a. Central Unit
42.0 SEER:16.00
c. U-Factor: Dbl, U=0.46 19.00 ft2
SHGC: SHGC=0.26
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ft2
a. Electric Strip Heat
42.0 COP:1.00
SHGC:
I
Area Weighted Average Overhang Depth: 6.169 ft.
Area Weighted Average SHGC: 0.244
14. Hot water systems
a. Electric
Cap: 50 gallons
8. Floor Types (1954.0 sgft.) I Insulation Area
EF: 0.950
a. Slab -On -Grade Edge Insulation R=0.0 1954.00 ft2
b. NIA R= ft2
_
ia atu
c. N/A R= ft2
15. Credits, = r/
Pstat
Glass/Floor Area: 0.131 Total Proposed Modified Loads: 62.99
PASS
Total Baseline Loads: 63.72
1 hereby certify that the plan and specifications covered by
Review of the plans and
, ST,4,7, -
I
this calculation are in compliance with the Florida Energy
specifications covered by this
O&T.
,. �' = ; 40
Code.
calculation indicates compliance
with the Florida Energy Code.
PREPARED BY:
Before construction is completed
DATE:
this building will be inspected for
compliance with Section 553.908
I hereby certify thatpi i esi ed, is in compliance
Florida Statutes.
C01) B
with the Florida Eo(ergy Coe
WE
OWNER/AGENT: ) I
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certi cation by the air handier unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed i accordance with R403.2.2.1.
- Compliance requires anlAir Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and starting July 1, 2017
this project requires an envelope leakage test report with envelope leakage no greater than 7.0 ACH50 (R402.4.1.2).
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with Section 803 of RESNET Standards, is not greater than 0.070 Qn for whole house.
8/28/2017 11:46 AM EnergyGaugeO USA - v5.1 - Section R405.4.1 Compliant Software Page 1 of 5
FORM R405-2014
PROJECT
Title:
Building Type:
Owner:
# of Units:
Builder Name:
Permit Office:
Jurisdiction:
Family Type:
New/Existing:
Comment:
BISCAYNE GRANDE eCLAS
User I
GHO Homes
1
GHO Homes I
Single-family
New (From Plans)
Bedrooms: 2
Conditioned Area: 1954
Total Stories: 1
Worst Case: No
Rotate Angle: 180
Cross Ventilation:
Whole House Fan:
-
Address Type:
Lot #
Block/SubDivision:
PlatBook:
Street:
County:
City, State, Zip:
Street Address
2672 Conifer Dr
St. Lucie
Ft Pierce ,
FL, 34953
CLIMATE
/
V Design Location TMY Site
IECC Design Temp
Zone 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, Fort Pierce iFL VERO_BEACH_MUNI 2 39 90
70
75 299
62 Low
BLOCKS
Number
Name Area
Volume
1
Blockl I 1954
18230.8
SPACES
Number
Name Area
Volume Kitchen Occupants
Bedrooms
InfilID Finished Cooled Heated
1
Main I 1954
18230.8 Yes 3
2
1 Yes
Yes Yes
FLOORS
#
Floor Type Space
Perimeter R-Value
Area
Tile Wood Carpet
1 Slab -On -Grade Edgi Insulatio Main 211.66 ft 0
1954 ft2
___
1 0 0
ROOF
V #
Type Materials
Roof Gable Roof
Area Area Color
Solar
Absor.
SA Emitt
Tested
Emitt Deck Pitch
Tested Insul. (deg)
1
Hip I Flat tile/slate
2185 ft2 0 ft2 Medium
0.75
No 0.9
No 0 26.6
ATTIC
V #
Type I Ventilation Vent Ratio (1 in)
Area
RBS IRCC
1
Full attic i Vented 150 1954 ft2
N N
I
CEILING
#
Ceiling Type
Space R Value Ins Type Area Framing Frac Truss Type
1
Under Attici(Vented)
Main 30 Blown
1954 ft2 0.11
Wood
8/28/2017 11:46 AM j EnergyGauge® USA - v5.1 - Section R405.4.1 Compliant Software Page 2 of 5
FORM R405-2014
WALLS
Adjacent I
Cavity
Width
Height
Sheathing Framing Solar
Below
Wpill
Space
1
S=>N Garage
Frame- Steel
Main
11
22
4
9 4
208.4 ft2
0.23 0.01
0
2
E=>W Garage
Frame - Steel
Main
11
2
0
9 4
18.7 ft2
0.23 0.01
0
3
S=>N Exterior
Concrete Block - Int Insul
Main
4.1
15
4
9 4
143.1 ft2
0 0.600000
0
_
4
W=>E Exterior
Concrete Block - Int Insul
Main
4.1
6
8
9 4
62.2 ft2
0 0.600000
0
_
_ 5
S=>N Exterior
Concrete Block - Int Insul
Main
4.1
7
4
9 4
68.4 ft2
0 0.600000
0
_ 6
W=>E Exterior
Concrete Block - Int Insul
Main
4.1
44
10
9 4
418.4 ft2
0 0.600000
0
7
N=>S Exterior
Concrete Block - Int Insul
Main
4.1
14
2
9 4
132.2 ft2
0 0.600000
0
_
8
E=>W Exterior
Concrete Block - Int Insul
Main
4.1
8
4
9 4
77.8 ft2
0 0.600000
0
_
9
NE=>SW Exterior
Concrete Block - Int Insul
Main
4.1
2
10
9 4
26.4 ft2
0 0.600000
0
_
10
N=>S Exterior
Concrete Block - Int Insul
Main
4.1
12
8
9 4
118.2 ft2
0 0.600000
0
_
11
W=>E Exterior
Concrete Block - Int Insul
Main
4.1
11
2
9 4
104.2 ft2
0 0.600000
0
_
12
N=>S Exterior
Concrete Block - Int Insul
Main
4.1
15
4
9 4
143.1 ft2
0 0.600000
0
_
13
E=>W Exterior
Concrete Block - Int Insul
I
Main
4.1
48
8
9 4
454.2 ft2
0 0.600000
0
DOORS
# Omt
I Door Type Space
Storms
U-Value
Width
Height Area
Ft
In
Ft In
1 S=>N I Wood
Main
None
.14
2
8
8 21.3 112
2 S=>N I Insulated
Main
None
.14
3
8 24 ft2
WINDOWS
Orientation shown is the entered orientation => changed to As Built rotated 180 degrees).
Wall
I
Overhang
V
# Omt ID
Frame Panes
NFRC
U-Factor
SHGC
Area
Depth
Separation
Int Shade Screening
1 W=>E 4
Metall Low-E Double
Yes
0.49
0.24
8.3 ft2
8 ft 4 in
1 ft 6 in
Drapes/blinds
None
2 S=>N 3
Metali Low-E Double
Yes
0.49
0.24
30.0 ft2
1 ft 0 in
1 ft 6 in
Drapes/blinds
None
3 S=>N 5
Metal Low-E Double
Yes
0.46
0.26
7.0 ft2
7 ft 8 in
1 ft 3 in
Drapes/blinds
None
4 W=>E 6
I
Metal Low-E Double
Yes
0.49
0.24
30.0 ft2
2 ft 0 in
1 ft 6 in
Drapes/blinds
None
5 N=>S 7
Metal Low-E Double
Yes
0.49
0.24
20.0 ft2
2 ft 0 in
1 ft 61n
Drapes/blinds
None
6 E=>W 8
Metal Low-E Double
Yes
0.49
0.24
20.0 ft2
15 ft 6 in
1 ft 6 in
Drapes/blinds
None
7 N=>S 10
Metal Low-E Double
Yes
0.5
0.25
72.0 ft2
12 ft 2 in
1 ft 7 in
Drapesiblinds
None
8 N=>S 12
Metal Low-E Double
Yes
0.49
0.24
36.0 ft2
2 ft 0 in
1 ft 5 in
Drapes/blinds
None
9 E=>W 13
Metal Low-E Double
Yes
0.46
0.26
12.0 ft2
2 ft 0 in
1 ft 6 in
Drapes/blinds
None
10 E=>W 13
Metal Low-E Double
Yes
0.49
0.24
20.0 ft2
2 It 0 in
1 ft 6 In
Drapes/blinds
None
GARAGE
# Floor Area Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1 534.8035 ft2 534.8035 ft2
I
69 It
9.33 It
0
8/28/2017 11:46 AM j EnergyGauge® USA - v5.1 - Section R405.4.1 Compliant Software Page 3 of 5
FORM R405-2014
INFILTRATION
# Scope Method I
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50)
.000415
2126.9 116.77 219.59 .3029
7
HEATING SYSTEM
# System Type
Subtype
Efficiency Capacity
Block
Ducts
1 Electric Strip Heat
None
COPA 42 kBtu/hr
1
sys#1
COOLING SYSTEM
# System Type
Subtype
Efficiency Capacity Air Flow
SHR Block
Ducts
1 Central Unit I
Split
SEER: 16 42 kBtu/hr 1260 cfm
0.75 1
sys#1
HOT WATER SYSTEM
# System Type SubType
Location
EF Cap Use SetPnt
Conservation
1 Electric I None
Garage
0.95 50 gal 50 gal 120 deg
None
SOLAR HOT WATER SYSTEM
FSEC I
Cart # Company Name
Collector
System Model # Collector Model # Area
Storage
Volume
FEF
None None I
ft'
DUCTS
/ — Supply —
V # Location R-Value Area
— Return— Air CFM 25 CFM25
Location Area Leakage Type Handler TOT OUT QN RLF
HVAC #
Heat Cool
1 Attic I 6 394.2 ft
Attic
98.55 ft Proposed Qn Main — cfm 136.8 cfm 0.07 0.60
1 1
TEMPERATURES
Programable Thermostat: Y I
Conlin Jan Feb Mar
Heating H Jan H Fete HX Mar
Ventin Jan Feb Mar
Ceiling Fans: N
Apr May Jun Jul Auge
E Apr I I May Jun Jul Au4 Sep E
lxl Apr May ]]] Jun Jul 111 Aug [ Se lx]
Oct Nov
Oct Nov
Oct Nov
Dec
Dec
Dec
8/28/2017 11:46 AM EnergyGauge® USA - v5.1 - Section R405.4.1 Compliant Software Page 4 of 5
FORM R405-2014
Thermostat Schedule:
Schedule Type
HERS 2006
Reference
I 1
2
3
4
5
6
Hours
7
8
9
10
11
12
Cooling (WD)
AM
178
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
78
78
78
78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78
78
78
78
78
78
78
78
78
PM
78
78
78
78
78
78
78
78
78
78
78
78
Heating (WD)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
Heating (WEH)
PM 168
68
68
68
68
68
68
68
68
68
66
66
f
8/28/2017 11:46 AM EnergyGauge® USA - v5.1 - Section R405.4.1 Compliant Software Page 5 of 5
I
I
I
I
FORM R405-2014
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 99
The lower the EnergyPerformance Index, the more efficient the home.
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple fan
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area (W)
7. Windows" Desci
a. U-Factor: Dbl, l
SHGC: SHG(
b. U-Factor: Dbl, L
SHGC: SHG(
c. U-Factor: Dbl, l
SHGC: SHG(
d. U-Factor: N/A
SHGC:
Area Weighted Average OverK
Area Weighted Average SHG(
8. Floor Types
a. Slab -On -Grade Edge Insulat
b. N/A
c. N/A
certify that this home has
Construction through the at
in this home before final ins
based on installed Code co
Builder Signature:
Address of New Home: 2
2672 Conifer Dr, Ft Pierce, FL, 34953
New (From Plans)
9. Wall Types
Single-family
a. Concrete Block - Int Insul, Exterior
b. Frame - Steel, Adjacent
1
c. N/A
2
d. N/A
10. Ceiling Types
No
a. Under Attic (Vented)
1954
b. N/A
Area
c. N/A
164.31 ft2
11. Ducts
a. Sup: Attic, Ret: Attic, AH: Main
72.00 ft2
12. Cooling systems
19.00 ft2
a. Central Unit
ft2
Depth: 6.169 ft.
0.244
Insulation Area
R=0.0 1954.00 ft2
R= ft2
R= ft2
13. Heating systems
a. Electric Strip Heat
14. Hot water systems
a. Electric
b. Conservation features
None
15. Credits
ith the Florida Energy Efficiency Code for Building
gy saving features which will be installed (or exceeded)
Otherwise, a new EPL Display Card will be completed
Date: Z
City/FL Zip:1"OYtv6te-
I? ULic
Insulation
Area
R=4.1
1748.40 ft2
R=11.0
227.11 ft2
R=
ft2
R=
ft2
Insulation
Area
R=30.0
1954.00 ft2
R=
ft2
R=
ft2
R ft2
6 394.2
kBtu/hr Efficiency
42.0 SEER:16.00
kBtu/hr Efficiency
42.0 COP:1.00
Cap: 50 gallons
EF: 0.95
Pstat
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321)
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support
staff.
**Label required by
R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
8/28/2017 9:52 AM I EnergyGauge® USA - v5.1 - Section R405.4.1 Compliant Software Page 1 of 1