Loading...
HomeMy WebLinkAboutProduct Approval Windows Mullions'Florida Building Code Online Page 1 of 3 r.Atkn a . ,. � Zt7 r x $.,sit a ,Ik �� 'I, t .€ ' a? : � Yz i;, - ■ p r.4L1,.r�j,4'i-'t Flo1da Department « BCIS Home Log In i User Registration Hot Topics ! Submit Surcharge i Slats & Facts ; Publications j FBC Staff ; BCIS Site Map j Unks Search BusinesC,(n2i rofessi $ = .- Product UerApproval Regulation f Product'Aoproval Menu >Product or Aonlicatlon Search > Application List.> Application Detail FL # FL35353-R2 Application Type Revision Code Version 2014 Application Status Pending FBC Approval Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Florida Engineer or Architect Name who developed the Evaluation Report Florida License Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By Certificate of Independence Referenced. Standard and 'Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code Product.Approval Method Date Submitted Date Validated MI Windows and Doors 650 West Market Street Gratz, PA 17030 (717) 365-3300 Ext 2560 bsiUinger@miwd.cwm Brent Sitlinger bsitlinger@miwd.com Windows Mullions Evaluation Report from a Florida Registered Architector a Licensed Florida. Professional Engineer ' Evaluation Report - Hardcopy Received Luis R Lomas, PE PE-62514 National Accreditation & Management Institute 12/31/2015 Steven M. Urich, PE :4: Validation Checklist - Hardcopy Received F +5353 R2 COI FLGOr.odf 1710.5.3 Method 2 Option B 06/15/2015 r 06/15/2015 6 http://floridabuilding.org/pr/Pr--aPP-2 7/24/2015 'Florida Building Code Online Page 2 of 3 Date Pending FBC Approval 06/21/2015 Summary of Products -v^ FL # Model, Number or Name Description 15353.-1 .15764 Horizontal Aluminum Mullion Limits of. Use Installation Instructions Approved for use In HVHZ: No R15353 R2. 11 08-6144flkodf Approved for use outside HVHZ: Yes Verified By: Luis R Lomas, PE PE-62514 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Max single window size:.52-1/8" x 84'. Max mullion span: FL15353 •R2 AE 512072A.odf 52-1/8". Created by Independent Third Party: Yes 15353.25764 Vertical Aluminum Mullion Limits or Use Installation Instructions Approved for use In HVHZ: No EL15353 R2 11 08-61439A.odf Approved for use outside HVHZ: Yes Verified By: Luis R Lomas, PE PE-62514 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports l Other: Max single window size: 52-1/8" x 841. Max mullion span: 83" FL15353 R2 AE 512063A.odf Created by Independent Third Pally: Yes i535363 15765 Horizontal Aluminum Mullion Limits o"se Installation Instructions Approved for use. In HVHZ: No FL15353 R2 it 08-01449A.pdf Approved for use outside HVHZ: Yes verified By: Luis R Lomas, PE PE-62514 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other.- Max Single Window size: 52-1/8' x 84% Max mullion span: FL15353 R2 AE 512073A.pdf 104-1/4' Created by Independent Third Party: Yes 15353.4 15765 Vertical.Aluminum Mullion Limits: of use installation Instructions j Approved for use in HVHZ: No FLIS353 R2 11 08-01440A,ndf Approved for use outside HVHZ: Yes Verified By:. Luis R Lomas, PE PE-62514 Impact Resistant: Yes Created by Independent. Third Party: Yes Design Pressure: N/A Evaluation Reports other: Max single window size: 52-1/8" x 84'. Max mullion span: 83". FL15353 R2 AE 512064A.odf Created. by Independent Third Party: Yes j 15353.5 CM-18514 vertical Aluminum Mullion Limits of Use Installation Instructions Approved for use in HVHZ: No FL15353 P2 it 03-01442A odf I Approved for use outside HVHZ Yes Verified By: Luis R Lomas, PE PE-62514 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Max single window size: 52-1/8" x 84'. Max mullion length - FL15353 R2 AE 512066A.Ddf 83". Created by Independent Third Party: Yes i5353.6 CM-18520 Horizontal Aluminum Mullion Limits of Use installation Instructions Approved for use In HVHZ: No F1.35353 R:2 II 09-01451A ndr Approved for use outside HVHZ: Yes 'Verified By`..Luis R Lomas, PE PE-62514 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation. Reports Other: Max single window size - 52-118" x 84". Max mullion span - FLIS353 R2 AE 512075A W 104-1/4' Created by Independent Third Party: Yes- i 15353.7 CM-18523 Horizontal Aluminum Mullion Limits of Use Installation Instructions Approved for use in HVHZ: No FL15353 5353 R2 '11 08-01452A odf Approved for use outside HVHZ: Yes Verified By:.LUIS R Lomas, PE PE-62514 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Max single window size - 52-1/8" x 84". Max mullion span - FL15353 R2 AE 512076A.pdf f Other: 104-1/4". Created by Independent Third Party: Yes 15353.8 CM-18531 Vertical Aluminum Mullion Limits of Use Installation Instructions i Approved for use in HVHZ No FL15353 R7 11 08.01443A calif Approved for use,outside HVHZ: Yes Verified By: Luis R Lomas, PE PE-62514 Ij Impact Resistant: Yes Created. by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Max single window size: 52-1/8' x 94'. Max mullion span - 83" FL15353 R2 AE 512067A ndr Created by Independent Third Party: Yes 15353.9 CM-16532 Horizontal Aluminum Mullion Limits of Use Installation Instructions Approved for use in HVHZ: No FL15353 R2 11 08-01453A.pdr Approved for use outside HVHZ: Yes Verified By: Luis R Lomas, PE PE-62514 Impact Resistant: Yes Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Max single window size- 52-1/8" x 84". Max mullion Span - FLIS353 S353 R2 AE 512077A.gdf 104-1/4" Created by Independent Third Party: Yes 15353.10 CM-18533 Vertical' Aluminum Mullion Limits of Use Installation Instructions Approved for use in HVHZ: No FL15353 R2 ti 08-01444A odf Approved for use outside HVHZ: Yes Verified By: Luis R Lomas, PE PE-62514 Impact Resistant: Yes Created' by Independent Third Party: Yes Design Pressure: N/A Other: Max single window size: 52-1/8" x 84". Max mullion span: 83' Evaluation Reports FLIS353 R2 AE 512068A ndf Created by independent Third Party: Yes 15353.11 CM-18534 Horizontal Aluminum Mullion Limits of Use Installation Instructions Approved for use in HVHZ: No FLIS353 R2 II 05-01454A odf Approved for use outside HVHZ: Yes Verified By: Luis R Lomas, PE PE-62514 Impact Resistant: Yes -Created by Independent Third Party: Yes Design Pressure: N/A Other: Max single window size: 52-1/8" x 84'. Max mullion span: Evaluation Reports FL15353 R2 AE 512078A.pjif 104-1/4". Created by IndeR2ndent Third Party: Yes http://floridabuildina.org/pr/pr_app_dtl.aspx?param=wGEVXQwd)gtH8572gvdwIsxrzuli... 7/24/2015 52 1/8" MAX. UNIT WIDTH (MULLION SPAN) F_111 WINDOW MAX. MAX. COMBINED HEIGHT - H2 WINDOW Maximum docinn nroaam m /nail Tributary --height Mullion span (in) 18.00 24.00 30.00 36.00 4200 4&00 SZ13 1&00 130.01 130.0 130.0 130.0 130.0 130.0 130.0 24.00 130.0 130.0 130.0 130.0 130.0 130.0 130.0 30.00 130.0 130.0 130.0 130.0 130.0 130.0 130.0 36.00 130.0 130.0 130.0 130.0 130.0 130.0 130.0 42.00 130.0 130.0 -130.0 130.0 130.0 130.0 130.0 48.00 130.0 130.0 130.0 130.0 130.0 130.0 130.0 54.00 130.0 130.0 130.0 130.0 130. 0 130.0 130.0 60.00 130.0 130.0 130.0 130.0 130.01 130.0 130.0 66.21 130.0 130.0 130.0 130.0 130.0 130.0 130.0 7200 130.0 130.0 130.0 130.0 130.0 130.0 130.0 78.00 1 130.01 130.0 130.0 130.0 130.0 130.0 130.0 84.00 1 130.01 130.0 130.0 130.0 130.0 130.0 130.0 LARGE AND SMALL MISSILE IMPACT, LEVEL D, WIND ZONE 3 DIMENSIONS IN CHARTARE FRAME DIMENSIONSAND DO NOT INCLUDE FLANGE 104.25" MAX. UNIT WIDTH (MULLION SPAN) H 1 WINDOW 168• MAX. COMBINED HEIGHT H2 [WfNDDW1Fw1NDOW Maximum dAmian nrPssure ranarRv rhart fmcil Tributary Mullion Span and individual unit width on) Height On) 36.00 48.00 60.00 7200 84.00 96.00 104.25 1&00 24.00 30.00 3&00 4200 48.00 5213 18.00 130.0 130.0 130.0 130.0 117.7 78.4 61.0 24.00 130.0 130.0 130.0 130.0 89.9 59.7 46.4 30.00 130.0 130.0 130.0 118.7 73.4 48.5 37.6 36.00 130.0 130.0 130.0 101.8 62.5 41.2 31.9 4200 130.0 130.0 130.0 89.9 54.9 36.0 27.8 48.00 1 130.0 1 130.0 130.01 81.2 49.3 322 24.8 54.00 130.0 130.0 124.7 74.5 45.0 29.3 22.5 60.00 13Q.0 130.0 116.5 69A 41.6 27.0 20.7 66.00 130.0 130.0 109.9 65A 38.9 25.1 19.2 7200 130.0 130.0 104.0 62.2 36.8 23.6 18.0 78.00 130.0 130.0 98.7 59.6 35.0 22.3 17.0 84.00 130.0 130.0 93.9 57.2 33.6 21.3 16.1 LARGEAND SMALL MISSILE IMPACT, LEVEL D. WIND ZONE 3 DIMENSIONS IN CHART ARE FRAME DIMENSIONSAND DO NOT INCLUDE FLANGE DESIGN PRESSURE TABLE INSTRUCTIONS: 15 DEFINE REQUIRED DESIGN LOAD PER FLORIDA BUILDING CODE CHAPTER 16. 2) DETERMINE TRIBUTARY HEIGHT AND MULLION SPAN BASED ON PRODUCT TO BE INSTALLED. SEE FORMULA FOR TRIBUTARY HEIGHT. 3) LOCATE MULLION SPAN (UNIT WIDTH) AND TRIBUTARY HEIGHT. AT THE INTERSECTION OF COLUMN AND ROW CONTAINING THE MULLION SPAN AND TRIBUTARY WIDTH RESPECTIVELY IS THE MULLION RATING FOR PRODUCT IN STEP 2. MULLION RATING MUST BE EQUAL OR GREATER THAN REQUIRED DESIGN PRESSURE OBTAINED IN STEP 1. TRIBUTARY HEIGHT= H1 + H2 2 TABLE OF CONTENTS SHEET NO. DESCRIPTION 1. 2' ELEVATION, NOTES AND DESIGN PRESSURE CHARTS 3 INSTALLATION DETAILS V.L. REVISIONS DESCRIPTION DATE I APPROVED REVISED INSTALLATION DETAILS 06/11/15 1 R.L. NOTES: 1) THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH REQUIREMENTS OF THE FLORIDA BUILDING CODE_ 2) WOOD FRAMING AND MASONRY OPENING TO BE DESIGNED AND ANCHORED TO PROPERLY TRANSFER ALL LOADS TO STRUCTURE. FRAMING AND MASONRY OPENING IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. 3) ALLOWABLE STRESS INCREASE OF 1/3 WAS NOT USED IN THE DESIGN OF THE PRODUCT SHOWN HEREIN. WIND LOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD ANCHOR CALCULATIONS. 4) APPROVED IMPACT PROTECTIVE SYSTEM IS NOT REQUIRED FOR THIS PRODUCT IN WIND BORNE DEBRIS REGIONS UP TO WIND ZONE 3 5) DESIGN PRESSURE AND INSTALLATION DETAILS SHOWN IN THIS DOCUMENT APPLY ONLY TO THE MULLION. WINDOWS MUST BE APPROVED UNDER SEPARATE APPROVAL. 6) SINGLE. UNITS TO BE MULLED ARE NOT LIMITED TO THOSE SHOWN IN THIS DRAWING. SINGLE UNITS TO BE MULLED TOGETHER MUST BE MANUFACTURED BY MI WINDOWS AND DOORS 7) DESIGN PRESSURE OF MULLED UNIT SHALL BE CONTROLLED BY THE LESSER DESIGN PRESSURE OF THE MULLION OR THE INDIVIDUAL WINDOW UNIT. 8) VERTICAL MULLIONS ARE NOT PART OF THIS APPROVAL VERTICAL MULLIONS USED TO MULL UNITS SIDE BY SIDE MUST HAVE SEPARATE APPROVAL. 9) FOR ADDITIONAL APPROVED CONFIGURATIONS SEE SHEET 2_ MI WINDOWS AND DOORS 650 WEST MARKET STREET GRATZ, PA 17030-0370 5765 HORIZONTAL MULLION SINGLE, TWIN AND TRIPLE WITH TRANSOM ELEVATION AND GENERAL NOTES 08-01449 NTS IDAE 03/06/12 SHEETI SIGNED: 0611212015 ```` ,5 lR I IL 0 '�7i',�i "• v�C E m'? f� fT51 OF •�� �'�F•'��OR1aQ:• ���� ��Viiis/OMAiIIN?G`N 1 N CON HE 156 3/8" MAX. UNIT WIDTH (MULLION SPAN) HI WINDOW 68" AX. BINED IGHT H2 WINDOW WINDOW Maximum design pressure capacity chat (pst) Tributary Height On) Mullion Span and Individual unit width pn) 54.00 7200 90.00 108.00 126 00 144.00 156.38 18.00 I 24.00 130.00 36.00 42.00 46.00 5Z13 1&00 130.0 130.01 97.1 55.8 35.0 23A 182 24.00 130.0 130.01 73.8 42.3 26.5 17.7 13.8 30.00 130.0 119.4N26.9 34.2 21.4 14.2 11.1 36.00 130.0 101.5 28.9 18.0 12 0 42.00 130.0 89.0 25.1 15.6 10.3 4&00 130.0 79.8 22.3 13.8 - 54.00 130.0 72.8 20.1 12.4 - 60.00 129A 67.4 18.3 11.3 66.00 122.4 63.3 16.9 10.4 7200 116.2 60.0 15.8 78.00 110.5 57.2 14.864.00 105.4 54.7 14.0 LARGEAND SMALL MISSILE IMPACT, LEVEL D, WIND ZONE 3 DIMENSIONS IN CHART ARE FRAME DIMENSIONS AND DO NOT INCLUDE FLANGE DESIGN PRESSURE TABLE INSTRUCTIONS: 1) DEFINE REQUIRED DESIGN LOAD PER FLORIDA BUILDING CODE' CHAPTER 16. 2) DETERMINE TRIBUTARY HEIGHT AND MULLION SPAN BASED ON PRODUCT TO BE INSTALLED. SEE FORMULA FOR TRIBUTARY HEIGHT. 3) LOCATE MULLION SPAN (UNIT WIDTH) AND TRIBUTARY HEIGHT. AT THE INTERSECTION OF COLUMN AND ROW CONTAINING THE MULLION SPAN AND TRIBUTARY WIDTH RESPECTIVELY IS THE MULLION RATING FOR PRODUCT IN STEP 2. MULLION RATING MUST BE EQUAL OR GREATER THAN REQUIRED DESIGN PRESSURE OBTAINED IN STEP 1. REVISIONS DESCRIPTION REVISED INSTALLATION DETAILS 4 5/8" 1 29/32" 27/32" 25/32" O C 3'8" 1 9/i6" O 13/16" O 3/8' 6X05/32" 1" SECT5768 CLIP ALUMINUM 6063-T5.093•THICK FOR WOOD FRAMING INSTALLATION 4 3'- -{ 13/16" 3" 9/16" O 25 32' SECT5768 CLIP 2Xm5/32" ALUMINUM 6063-TS.093' THICK FOR MASONRY/CONCRETEINSTALLATION RIBUTARY HEIGHT - H1 + H2 2 DATE I APPROVED 06/11/15 1 R.L. SECT5765 MULLION ALUMINUM 6005-T5.125" THICK MI WINDOWS AND DOORS 650 WEST MARKET STREET GRATZ, PA 17030-0370 5765 HORIZONTAL MULLION SINGLE, TWIN AND TRIPLE WITH TRANSOM ELEVATION AND COMPONENTS V. L. 1 08-01449 vI` NTS I DATE 03/06/12 ISHEET2 OF 3 SIGNED: 0611212015 REV DESCRIPTION DATE APPROVED A REVISED INSTALLATION DETAILS 06/11/15 R.L. 1 3/8" OD MIN. EMBEDMENT MIN. EMBEDMENT 5765 MULLION 57681/2 MIN. LS' INTERIOR 1/4" TAPCON d< 2 1/2" EDGE MIN. DISTANCE EDGE j I: I DISTANCE WOOD FRAMING 1 i OR 2X BUCK -----.. - i'`•• +++; BY OTHERS d MASONRY/CONCRETE BY OTHERS " EXTERIOR MULLION INSTALLATION I CLIP INSTALLATION ANCHORING NOTES: - 1) FOR ANCHORING INTO CONCRETE USE 1/4" TAPCONS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE WITH 2 1/2" MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 2) FOR ANCHORING INTO WOOD FRAMING OR 2X BUCK USE #10 WOOD SCREW WITH SUFFICIENT LENGTH TO ACHIEVE A 1 3/8" MINIMUM EMBEDMENT INTO SUBSTRATE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 3) FOR ATTACHING WINDOW UNITS TO MULLION USE #10 TEK SELF TAPPING SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A MINIMUM EMBEDMENT OF THREE THREADS PAST THE MULLION WALL. LOCATE SCREWS 6" FROM EACH MULLION END AND 12" MAX. O.C. THEREAFTER. STAGGER SCREWS AT EACH WINDOW. 5) FOR WINDOW UNITS ANCHORING SCHEDULE REFER TO WINDOW APPROVED INSTALLATION INSTRUCTIONS. SIGNED., 0611212015 6) ALL FASTENERS TO BE CORROSION RESISTANT. MI WINDOWS AND DOORSIIL0INST7j//� 7) INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR MANUFACTURER'S I ON AND CHORS SHALL SUBSTRATES WITH 650 ST MARKET 5 LESSTTHANONS, STRENGTHS THE MINIMUM STTRENGTHSPECIFIED BELOWN GRATZ,PA 170300370� F " A. WOOD - MINIMUM SPECIFIC GRAVITY OF G=0.42 B. CONCRETE - MINIMUM COMPRESSIVE STRENGTH OF 3.200 PSI. 5765 HORIZONTAL MULLION • per$ k= SINGLE, TWIN AND TRIPLE WITH TRANSOM =-o INSTALLATION DETAILS �� �y0 , TATE OF to DRAWN: OWC N0. REV Q ��Fs 08 _ A ���/j���NAj1��\\\� SGLLE NTS DATE 03/06/12 5o�390F 3 NOTES: 1) THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH REQUIREMENTS OF THE FLORIDA BUILDING CODE. 2) WOOD FRAMING TO BE DESIGNED AND ANCHORED TO PROPERLY TRANSFER ALL LOADS TO STRUCTURE. FRAMING IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. 3) ALLOWABLE STRESS INCREASE OF 1/3 WAS NOT USED IN THE DESIGN OF THE PRODUCT SHOWN HEREIN. WIND LOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD ANCHOR CALCULATIONS. 4) APPROVED IMPACT PROTECTIVE SYSTEM IS NOT REQUIRED FOR THIS PRODUCT IN WIND BORNE DEBRIS REGIONS UP TO WIND ZONE 3. 5) DESIGN PRESSURE AND INSTALLATION DETAILS SHOWN IN THIS DOCUMENT APPLY ONLY TO MULLION. WINDOWS MUST BE APPROVED UNDER SEPARATE APPROVAL. 6) SINGLE WINDOWS TO BE MULLED ARE NOT LIMITED TO THOSE SHOWN IN THIS DRAWING. WINDOWS MUST BE MANUFACTURED BY MI WINDOWS AND DOORS, INC. 7) DESIGN PRESSURE OF MULLED UNIT SHALL BE CONTROLLED BY THE LESSER DESIGN PRESSURE OF THE MULLION OR THE INDIVIDUAL WINDOW OR DOOR UNIT. 8) UNITS MAY BE MULLED TOGETHER INDEFINITELY AS LONG AS SINGLE UNIT WIDTH AND HEIGHT ARE NOT EXCEEDED AND MULLION IS ANCHORED AS SHOWN HEREIN. 9) MULLION VERTICAL INSTALLATION IS SHOWN, MULLION MAY BE USED IN HORIZONTAL APPLICATIONS AS LONG AS DIMENSIONS INDICATED HEREIN ARE NOT EXCEEDED AND MULLION IS ANCHORED ACCORDING TO THIS DOCUMENT. DESIGN PRESSURE TABLE INSTRUCTIONS: 1) DEFINE REQUIRED DESIGN LOAD PER FLORIDA BUILDING CODE CHAPTER 16. 2) DETERMINE TRIBUTARY WIDTH AND MULLION SPAN BASED ON PRODUCT TO BE INSTALLED. SEE FORMULA FOR TRIBUTARY WIDTH. 3) LOCATE MULLION SPAN (UNIT HEIGHT) AND TRIBUTARY WIDTH. AT THE INTERSECTION OF ROW AND COLUMN CONTAINING THE MULLION SPAN AND TRIBUTARY WIDTH RESPECTIVELY IS THE MULLION RATING FOR PRODUCT IN STEP 2. MULLION RATING MUST BE EQUAL OR GREATER THAN REQUIRED DESIGN PRESSURE OBTAINED IN STEP 1. TRIBUTARY WIDTH = W7 + W2 2 REVISIONS REV I DESCRIPTION DATE APPROVED A REVISED INSTALLATION DETAILS 06/10/15 R.L ANCHORING NOTES: 1) FOR ANCHORING INTO WOOD FRAMING OR 2X BUCK USE #10 WOOD SCREW WITH SUFFICIENT LENGTH TO ACHIEVE A 1 3/8" MINIMUM EMBEDMENT. LOCATE ANCHORS AS SHOWN IN INSTALLATION DETAILS SHEET 3. 2) FOR ANCHORING INTO CONCRETE USE 1/4" TAPCON WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT WITH 2 1/2" MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN IN INSTALLATION DETAILS SHEET 4. 3) FOR ATTACHING WINDOW UNITS TO MULLION USE #10 SELF DRILLING SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A MINIMUM EMBEDMENT OF THREE THREADS PAST THE MULLION WALL. LOCATE SCREWS IN ACCORDANCE WITH WINDOW ANCHORING SCHEDULE AS SHOWN IN WINDOW SEPARATE APPROVAL 4) ALL FASTENERS TO BE CORROSION RESISTANT. 5) INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS, AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW: A. WOOD - MINIMUM SPECIFIC GRAVITY OF G=0.42 B. CONCRETE - MINIMUM COMPRESSIVE STRENGTH OF 3,20D PSI. C. MASONRY - STRENGTH CONFORMANCE TO ASTM C-90. GRADE N, TYPE 1 (OR GREATER). 6) TO ATTACH MULLION TO CLIP USE (4) #10 x 1 1/4" SELF DRILLING SCREWS PER CLIP. SCREWS MUST BE FIELD INSTALLED. HOLES FOR SCREWS ARE NOT PRE -DRILLED BY MANUFACTURER. TABLE OF CONTENTS SHEET NO.1 DESCRIPTION NOTES CONFIGURATIONS AND DP CHART INSTALLATION DETAILS MI WINDOWS AND DOORS 650 WEST MARKET STREET GRATZ, PA 17030-0370 5765 VERTICAL MULLION 83" MULLION SPAN GENERAL NOTES DRAWN: DWG NO. V.L. 08-01440 Sre' E NTS DATE 01 /11 /12 1 SHEET 1 OF 3 SIGNED: 0611112015 o TAT 5E OF •tv ��F' ���/ss/Ofi ENG\�� 107 3/8' T OMBINED WIDTH w 1 83" FRAME HEIGHT WINDOW WINDOW (MULLION SPAN) 107 3/B' T OMBINED WIDTH W1 -jr- W2 83" ll"OW FRAME HEIGHT WINDOW (MULLION SPAN) L / 107 3/8" COMBINED WIDTH 3" ,/ ,/ WINDOW /// FRAME HEIGHT WINDO ` WINDO (MULLION SPIN) W1 --I I- LW2 107 3/8" COMBINED WIDTH Design Pressure radna losB 107 3/8" COMBINED WIDTH w1 8Y I FRAME 'WINDOW WINDOW HEIGHT (MULLION SPAN) F_ 107 3/8" COMBINED WIDTH /Wt --{� W2 / 83" WINDOW FRAME HEIGHT WINDO (MULLION SPALI] Wt --IF^ W2! 107 3/8" COMBINED WIDTH Mullion span (n) Tributary 18.13 2550 width 36.00 42.00 (In) 48.00 5213 25.00 130.0 130.0 130.0 130.0 130.0 130.0 37.38 130.0 130.0 130.0 130.0 130.0 130.0 49.63 130.0 130.0 130.0 130.0 130.0 130.0 6ZOO 130.0 130.0 112.0 103.0 97.3 94.7 65.63 130.0 130.0 103.5 94.7 88.8 86.0 7Z00 130.0 117.4 91.3 82.8 77.0 74.1 84.00 120.2 87.0 64.0 56.4 61.01 48.1 REVISIONS REV I DESCRIPTION DATE I APPROVED A I REVISED INSTALLATION DETAILS 06/10/15 1 R.L. 107 3/8" COMBINED WIDTH F_ W2 83" !W7 J J WINDOW j FRAME HEIGHT WINDO f WINDOW (MULLION SPAN) / /J y/ APPROVED CONFIGURATIONS MULTIPLE UNITS MAYBE MULLED TOGETHER AS LONG AS COMBINED WIDTH DOES NOT EXCEED 107318' AS SHOWN HEREIN. LARGE AND SMALL MISSILE IMPACT, LEVEL D, WIND ZONE 3 DIMENSIONS IN CHART ARE FRAME DIMENSIONSAND DO NOT INCLUDE FLANGE W7 --I �- W2 107 3/8" COMBINED WIDTH MI WINDOWS AND DOORS_ 650 WEST MARKET STREET GRATZ, PA 17030-0370 5765 VERTICAL MULLION 83" MULLION SPAN APPROVED CONFIGURATIONS AND RATING CHART 1WN: I DWG NO. I I V.L. 1 08-01440 S' NTS DATE 01/11/12 --2 OF 3 SIGNED: 0611112015 .v ��CENs� •� y *• 0,r51 •*_ 0-4 OF 2 1/2" MIN. EDGE DISTANCE MASONRY/CONCRETE a BY OTHERS e 1 1/4" -° e . MIN: EMBEDMENT — — I I I 1/4" TAPCON SECT5768 CLIP SECT5765 MULLION SECT5768 CLIP jj10 WOOD SCREW r-- I I I 1 3/8" MIN. EMBEDMENT WOOD FRAMING/ /2X BUCK 1 2 MIN. BY OTHERS J EDGE DISTANCE VERTICAL CROSS SECTION MASONRWCONCRETEAND WOOD FRAMING INSTALLATION NOTES: 1) FOR FRAMING INSTALLATION USE ALL FOUR HOLES IN INSTALLATION CUP. 2) FOR MASONRY/CONCRETE INSTALLATION USE HOLES AT EACH -END OF INSTALLATION CUP. INSTALL TWO TAPCONS PER CLIP. DRAWN: V.L. 'CA`E NITS REVISIONS DESCRIPTION DATE I APPROVED REVISED INSTALLATION DETAILS 06/10/15 1 R.L. 0.212" 3.800" -{ I__T 1.125" SECT5765 MULLION ALUMINUM 6005-T5.125" THICK TICK 4.624" 1.891" 0.843" 70 81" 1.562" [1 O O 4X 00.171" 0.375" 1.000" SECT5768 CLIP ALUMINUM 6063-T5.093' THICK MI WINDOWS AND DOORS 650 WEST MARKET STREET GRATZ, PA 17030-0370 5765 VERTICAL MULLION 83" MULLION SPAN INSTALLATION DETAILS DWO N0. 08-01440 DATE 01 /11 /12 1SHEE13 OF 3 SIGNED: 0611112015 EN3�.9iP � "TAT E OF •� _