Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Project Information
I Building Analysis Entire House For: I GHO Homes 2672 Conifer Drive, Fort Pierce, FL 34953 Location: St Lucie Co Intl, FL, US Elevation: 26 ft Latitude: 28°N Outdoor: Heating Dry bulb (°F) 41 Daily range °F) - Wet - Wind speed (mph) 15.0 Indoor: Indoor temperature (°F) Design TD (°F Relative humi ity (%) Cooli0ng Moisture difference (gr/lb) li Infiltration: 15 ( L ). Method 77 Construction quality 7.5 Fireplaces Component Btuh%ft2 Btuh % of load Walls 4.1 6967 21.6 Glazing 14.2 3670 11.4 Doors 11.3 528 1.6 Ceilings 0.9 1762 5.5 Floors 3.4 6436 19.9 Infiltration 2.1 3718 11.5 Ducts 6722 20.8 Piping 0 0 Humidification 0 0 Ventilation 2486 7.7 Adjustments 0 Total 32289 100.0 Component Btuh/ft- Btuh % of load Walls 2.5 4309 15.9 Glazing I 15.0 3873 14.3 Doors 11.4 533 2.0 Ceilings 1.0 1993 7.3 Floors 0 0 0 Infiltration 0.6 1039 3.8 Ducts 8078 29.7 Ventilation I 1320 4.9 Internal gains I 6010 22.1 Blower I 0 0 Adjustments 0 Total j 27155 100.0 I Latent Cooling Load = 9152 Btuh Overall U-value = 0.115 B'tuh/ft2-°F i Data entries checked. I I I Job: Biscayne Grande Lot 53 Date: 6-13-17 By: Skyetec Heating Cooling 70 75 29 15 50 50 24.4 56.9 Simplified Average 0 1 wrilghtsoftm 2017-Aug-3016:24:29 Right -Suite® Universal 2017 17.0.04 RS000269 page 1 ..ulations\Skytec\Biscayne Grande Lot 53 GR N.rup Calc = MJ8 Front Door faces: N Component Constructions Entire House For: GHO Homes 2672 Conifer Drive, Fort Pierce, FL 34953 Job: Biscayne Grande Lot 53 Date: 6-13-17 By: Skyetec Location: Indoor: Heating Cooling St Lucie Co Intl, FL, US Indoor temperature (°F) 70 75 Elevation: 26 ft Design TD (OF) 29 15 Latitude: 28ON Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference (gr/lb) 24.4 56.9 Dry bulb (OF) 41 90 Infiltration: Daily range (OF) - 15 ( L ) Method Simplified Wet bulb (OF) - 77 Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces 0 Construction descriptio �s Walls 13A-4ocs: Blk wall, stucco ext, r-4lext bd ins, 8" thk, 1/2" gypsum board int fnsh Partitions 1213-0sm: Frm wall, stucco ext, r- 1 cav ins, 1/2" gypsum board int fnsh, 2"x4" metal frm, 16" o.c. stud Or Area U-value Insul R Htg HTM ft' Btuh/R? `F ft? °F/Stuh Btuh/W n 144 0.143 4.0 4.15 e 548 0.143 4.0 4.15 s 286 0.143 4.0 4.15 sw 46 0.143 4.0 4.15 w 484 0.143 4.0 4.15 all 1507 0.143 4.0 4.15 Windows 2 glazing, clr low-e outr, argon gas, vnl frm mat, clr innr, 1/4" gap, 1/4" n thk: 2 glazing, cir low-e outr, argon gas, vnl frm mat, clr innr, 1/4" gap, 1/4" thk; NFRC rated (SHGC=0.26); 50% blinds 45°, medium; 50% outdoor insect screen; 4 ft overhang (8 ft window ht, 3 ft sep.); 6.67 ft head ht 2 glazing, cir low-e outr, argon gas, vnl frm mat, cir innr, 1/4" gap, 1/4" n thk: 2 glazing, cir low-e outr, argon gas, vnl frm mat, clr innr, 1/4" gap, 1/4" thk; NFRC rated (SHGC=0.24); 50% blinds 45°, medium; 50% outdoor insect screen; 1.5 ft overhang (6 ft window ht, 1 ft sep.); 6.67 ft head ht 2 glazing, clr low-e outr, argon gas, vnl frm mat, cir innr, 1/4" gap, 1/4" e thk: 2 glazing, cir low-e outr, argon gas, vnl frm mat, clr innr, 1/4" gap, 1/4" thk; NFRC rated (SHGC=0.24); 50% blinds 45% medium; 50% outdoor insect screen; 1 ft overhang (5 ft window ht, 1 ft sep.); 6.67 ft head ht I 2 glazing, clr low-e outr, argon gas, vnl frm mat, cir innr, 1/4" gap, 1/4" e thk: 2 glazing, cir low-e outr, argon gas, vnl frm mat, clr innr, 1/4" gap, s 1/4" thk; NFRC rated (SHGC=0.24); 50% blinds 45°, medium; 50% s outdoor insect screen; 1.5 ft overhang (5 ft window ht, 1 ft sep.); 6.67 ft w head ht all Loss Clg HTM Gain Btuh Btuh/ft' Btuh 595 2.59 371 2270 2.59 1417 1184 2.59 739 192 2.59 120 2006 2.59 1252 6249 2.69 3900 203 0.122 11.0 3.54 718 2.01 409 8 0.460 0 13.3 107 10.1 81 36 0.490 0 14.2 512 10.2 368 10 0.490 0 14.2 142 24.9 249 30 0.490 0 14.2 426 24.2 725 30 0.490 0 14.2 426 10.2 307 20 0.490 0 14.2 284 10.2 205 20 0.490 0 14.2 284 24.2 483 100 0.490 0 14.2 1421 17.2 1720 2017-Aug-30 16:24:29 �- wrightsoft' RightSuite® Universal 2017 17.0.04 RS000269 Page 1 ... ulations\Skytec\Biscayne Grande Lot 53 GR N.rup Cale = MJ8 Front Door faces: N 2 glazing, clr low-e outr, argon gas, v I I frm mat, clr innr, 1/4" gap, 1/4" s 72 0.500 thk: 2 glazing, clr low-e outr, argon gas, vnl frm mat, clr innr, 1/4" gap, 1/4" thk; NFRC rated (SHGC=0.25); 50% blinds 45°, medium; 50% outdoor insect screen; 12.5 ft overhang (8 ft window ht, 1 ft sep.); 6.67 ft head ht 2 glazing, clr low-e outr, argon gas, frm mat, clr innr, 1/4" gap, 1/4" w 12 0.460 thk: 2 glazing, clr low-e outr, argon gas, vnl frm mat, clr innr, 1/4" gap, 1/4" thk; NFRC rated (SHGC=0.26); 50% blinds 45°, medium; 50% outdoor insect screen; 1.5 ft overhang (2 ft window ht, 1 ft sep.); 6.67 ft head ht i 2 glazing, clr low-e outr, argon gas, vnl frm mat, clr innr, 1/4" gap, 1/4" w 20 0.490 thk: 2 glazing, clr low-e outr, argon gas, vnl frm mat, clr innr, 1/4" gap, 1/4" thk; NFRC rated (SHGC=0.24);'50% blinds 45°, medium; 50% outdoor insect screen; 3 ft overhangl(5 ft window ht, 1 ft sep.); 6.67 ft head ht Doors 0 14.5 1044 10.5 757 0 13.3 160 24.0 288 0 14.2 284 20.5 410 11 DO: Door, wd sc type I n 24 0.390 0 Ceilings 16D-30td:Attic ceiling, tile, slate, c gypsum board intfnsh Floors 22A-tpm: Bg floor, heavy dry or ligh fnsh roof mat, r-30 cell ins, 1/2" n 23 0.390 0 all 47 0.390 0 1899 0.032 30.0 11.3 271 11.4 274 11.3 256 11.4 259 11.3 528 11.4 533 0.93 1762 1.05 1993 t damp soil, on grade depth, tile fir 188 1.180 0 34.2 6436 0 0 + wrightsoft® Right -Suite® Universal 2017 17.0.04 RS000269 � ..ulations\Skytec\Biscayni Grande Lot 53 GR N.rup Calc = MJ8 Front Door faces: N I -- 2017-Aug-30 16:24:29 Page 2 i I I Project Summary Entire House For: i GHO Homes 2672 Conifer Drive, Fort Pierce, FL 34953 Job: Biscayne Grande Lot 53 Date: 6-13-17 By: Skyetec Weather: St Lucie Co Intl, FL, US Winter Design Conditions Summer Design Conditions Outside db 41 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 29 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 57 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 25567 Btuh Structure 19078 Btuh Ducts 6722 Btuh Ducts 8078 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 32289 Btuh I Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipment sensible load 25906 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 6787 Btuh Ducts 2365 Btuh Heating Cooling Area (ft2) 1899 189 Central vent 0 cfm) Equipment latent load 0 9152 Btuh Btuh Volume (ft3) 18422 18422 Air changes/hour 0.38 0.20 Equipment total load 35059 Btuh Equiv. AVF (cfm) 117 61 Req. total capacity at 0.80 SHR 2.7 ton Heating Equipment Summary Cooling Equipment Summary Make Make Rheem Trade Trade RHEEM; RUUD Model Cond RA1642AJ1 AHRI ref Coil RH1T4821STAN AHRI ref 7942888 Efficiency 1 100 EFF Efficiency 13.0 EER, 16 SEER Heating input 12.3 kW Sensible cooling 33200 Btuh Heating output 41975 Btuh Latent cooling 8300 Btuh Temperature rise 28 OF Total cooling 41500 Btuh Actual air flow 1383 cfm Actual air flow 1383 cfm Air flow factor 0.043 cfm/Btuh Air flow factor 0.051 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat I I Load sensible heat ratio 0.75 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. ` 2017-Aug-30 16:24:29 ACC"wrightsofI Right -Suite® Universal 2017 17.0.04 RS000269 Page 1 ...ulations\Skytec\Biscayne Grande Lot 53 GR N.rup Calc = MJ8 Front Door faces: N Duct System Summary Entire House For: GHO Homes 2672 Conifer Drive, Fort Pierce, FL 34953 External static pressure Pressure losses Available static pressure Supply / return available pr Lowest friction rate Actual air flow Tnfml cf ar-fivc Icnnfh tTl=I \ Heating 0.50 in H2O 0.18 in H2O 0.32 in H2O 0.237 / 0.083 in H2O 0.101 in/100ft 1383 cfm Job: Biscayne Grande Lot 53 Date: 6-13-17 By: skyetec Cooling 0.50 in H2O 0.18 in H2O 0.32 in H2O 0.237 / 0.083 in H2O 0.101 in/100ft 1383 cfm q1R ft Name Design (Btuh� Htg (cfm) Clg (cfm) Design FIR Diam (in) H x W (in) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BR 2 C 3517 143 179 0.186 8.0 Ox 0 VIFx 7.3 120.0 st1 Bath 2 c 186 3 4 0.183 4.0 Ox 0 VIFx 10.1 120.0 st1 Den h 4082 175 96 0.101 8.0 Ox 0 VIFx 44.3 190.0 st2 Dining h 2644 113 110 0.108 7.0 Ox0 VIFx 33.9 185.0 st2 Foyer h 1084 46 35 0.103 4.0 Ox0 VIFx 45.4 185.0 st2 Hers c 60 2 3 0.117 4.0 Ox 0 VIFx 27.5 175.0 st3 His h 1865 37 17 0.112 4.0 Ox 0 VIFx 32.0 180.0 st3 Kitchen C 6686 266 341 0.103 10.0 Ox 0 VIFx 44.5 185.0 st2 Living C 2083 82 106 0.110 6.0 Ox 0 VIFx 35.3 180.0 st3 Living•A C 2083 82 106 0.109 6.0 Ox 0 VIFx 38.6 180.0 st3 M Bath h �1598 68 64 0.112 5.0 Ox0 VIFx 32.3 180.0 st3 Master BR h 3192 137 104 0.111 7.0 Ox 0 VIFx 34.8 180.0 st3 Master BR -A h 3192 137 104 0.112 7.0 Ox 0 VIFx 32.3 180.0 st3 Utility c 2148 89 109 0.182 7.0 Ox0 VIFx 10.4 120.0 st1 WC c 30 1 2 0.113 4.0 Ox 0 VIFx 30.6 180.0 st3 WIC c 48 2 2 0.184 4.0 Ox0 VIFx 9.1 120.0 st1 Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FIR (fpm) (in) (in) Material Trunk st1 Peak AVF 1383 1383 0.101 634 20.0 0 x 0 VinlFlx st2 Peak AVF 601 582 0.101 562 14.0 0 x 0 VinlFlx st1 st3 Peak AVF 545 506 0.109 510 14.0 0 x 0 VINFlx st1 I® 2017-Aug-30 16:24:30 - - wrightsoft Right-Suite(g) Universal 2017 17.0.04 RS000269 Page 1 ...ulations\Skytec\BiscaynelGrande Lot 53 GR N.rup Calc = MJ8 Front Door faces: N Grill Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in) (cfm) (cfm) (ft) FIR (fpm) (in) (in) Opening (in) Matl Trunk rb1 Ox0 1383 1383 81.5 0.101 634 20.0 Ox 0 VIFx wri htsoft® 2017-Aug-30 16:24:30 9 Right -Suite® Universal 2017 17.0.04 RS000269 Page 2 ...ulations\Skytec\Biscayne Grande Lot 53 GR N.rup Calc = MJ8 Front Door faces: N