Building Analysis
Entire House
For: I GHO Homes
2672 Conifer Drive, Fort Pierce, FL 34953
Location:
St Lucie Co Intl, FL, US
Elevation: 26 ft
Latitude: 28°N
Outdoor: Heating
Dry bulb (°F) 41
Daily range °F) -
Wet -
Wind speed (mph) 15.0
Indoor:
Indoor temperature (°F)
Design TD (°F
Relative humi ity (%)
Cooli0ng
Moisture difference (gr/lb)
li
Infiltration:
15 ( L ).
Method
77
Construction quality
7.5
Fireplaces
Component
Btuh%ft2
Btuh
% of load
Walls
4.1
6967
21.6
Glazing
14.2
3670
11.4
Doors
11.3
528
1.6
Ceilings
0.9
1762
5.5
Floors
3.4
6436
19.9
Infiltration
2.1
3718
11.5
Ducts
6722
20.8
Piping
0
0
Humidification
0
0
Ventilation
2486
7.7
Adjustments
0
Total
32289
100.0
Component
Btuh/ft-
Btuh
% of load
Walls
2.5
4309
15.9
Glazing
I 15.0
3873
14.3
Doors
11.4
533
2.0
Ceilings
1.0
1993
7.3
Floors
0
0
0
Infiltration
0.6
1039
3.8
Ducts
8078
29.7
Ventilation
I
1320
4.9
Internal gains
I
6010
22.1
Blower
I
0
0
Adjustments
0
Total
j
27155
100.0
I
Latent Cooling Load = 9152 Btuh
Overall U-value = 0.115 B'tuh/ft2-°F
i
Data entries checked.
I
I
I
Job: Biscayne Grande Lot 53
Date: 6-13-17
By: Skyetec
Heating
Cooling
70
75
29
15
50
50
24.4
56.9
Simplified
Average
0
1 wrilghtsoftm 2017-Aug-3016:24:29
Right -Suite® Universal 2017 17.0.04 RS000269 page 1
..ulations\Skytec\Biscayne Grande Lot 53 GR N.rup Calc = MJ8 Front Door faces: N
Component Constructions
Entire House
For: GHO Homes
2672 Conifer Drive, Fort Pierce, FL 34953
Job: Biscayne Grande Lot 53
Date: 6-13-17
By: Skyetec
Location:
Indoor:
Heating
Cooling
St Lucie Co Intl, FL, US
Indoor temperature (°F)
70
75
Elevation: 26 ft
Design TD (OF)
29
15
Latitude: 28ON
Relative humidity (%)
50
50
Outdoor: Heating
Cooling
Moisture difference (gr/lb)
24.4
56.9
Dry bulb (OF) 41
90
Infiltration:
Daily range (OF) -
15 ( L )
Method
Simplified
Wet bulb (OF) -
77
Construction quality
Average
Wind speed (mph) 15.0
7.5
Fireplaces
0
Construction descriptio �s
Walls
13A-4ocs: Blk wall, stucco ext, r-4lext bd ins, 8" thk, 1/2" gypsum
board int fnsh
Partitions
1213-0sm: Frm wall, stucco ext, r- 1 cav ins, 1/2" gypsum board int
fnsh, 2"x4" metal frm, 16" o.c. stud
Or
Area
U-value
Insul R
Htg HTM
ft'
Btuh/R? `F
ft? °F/Stuh
Btuh/W
n
144
0.143
4.0
4.15
e
548
0.143
4.0
4.15
s
286
0.143
4.0
4.15
sw
46
0.143
4.0
4.15
w
484
0.143
4.0
4.15
all
1507
0.143
4.0
4.15
Windows
2 glazing, clr low-e outr, argon gas, vnl frm mat, clr innr, 1/4" gap, 1/4" n
thk: 2 glazing, cir low-e outr, argon gas, vnl frm mat, clr innr, 1/4" gap,
1/4" thk; NFRC rated (SHGC=0.26); 50% blinds 45°, medium; 50%
outdoor insect screen; 4 ft overhang (8 ft window ht, 3 ft sep.); 6.67 ft
head ht
2 glazing, cir low-e outr, argon gas, vnl frm mat, cir innr, 1/4" gap, 1/4" n
thk: 2 glazing, cir low-e outr, argon gas, vnl frm mat, clr innr, 1/4" gap,
1/4" thk; NFRC rated (SHGC=0.24); 50% blinds 45°, medium; 50%
outdoor insect screen; 1.5 ft overhang (6 ft window ht, 1 ft sep.); 6.67 ft
head ht
2 glazing, clr low-e outr, argon gas, vnl frm mat, cir innr, 1/4" gap, 1/4" e
thk: 2 glazing, cir low-e outr, argon gas, vnl frm mat, clr innr, 1/4" gap,
1/4" thk; NFRC rated (SHGC=0.24); 50% blinds 45% medium; 50%
outdoor insect screen; 1 ft overhang (5 ft window ht, 1 ft sep.); 6.67 ft
head ht I
2 glazing, clr low-e outr, argon gas, vnl frm mat, cir innr, 1/4" gap, 1/4" e
thk: 2 glazing, cir low-e outr, argon gas, vnl frm mat, clr innr, 1/4" gap, s
1/4" thk; NFRC rated (SHGC=0.24); 50% blinds 45°, medium; 50% s
outdoor insect screen; 1.5 ft overhang (5 ft window ht, 1 ft sep.); 6.67 ft w
head ht all
Loss
Clg HTM
Gain
Btuh
Btuh/ft'
Btuh
595
2.59
371
2270
2.59
1417
1184
2.59
739
192
2.59
120
2006
2.59
1252
6249
2.69
3900
203
0.122
11.0
3.54
718
2.01
409
8
0.460
0
13.3
107
10.1
81
36 0.490 0 14.2 512 10.2 368
10 0.490 0 14.2 142 24.9 249
30
0.490
0
14.2
426
24.2
725
30
0.490
0
14.2
426
10.2
307
20
0.490
0
14.2
284
10.2
205
20
0.490
0
14.2
284
24.2
483
100
0.490
0
14.2
1421
17.2
1720
2017-Aug-30 16:24:29
�- wrightsoft' RightSuite® Universal 2017 17.0.04 RS000269
Page 1
... ulations\Skytec\Biscayne Grande Lot 53 GR N.rup Cale = MJ8 Front Door faces: N
2 glazing, clr low-e outr, argon gas, v I I frm mat, clr innr, 1/4" gap, 1/4" s 72 0.500
thk: 2 glazing, clr low-e outr, argon gas, vnl frm mat, clr innr, 1/4" gap,
1/4" thk; NFRC rated (SHGC=0.25); 50% blinds 45°, medium; 50%
outdoor insect screen; 12.5 ft overhang (8 ft window ht, 1 ft sep.); 6.67
ft head ht
2 glazing, clr low-e outr, argon gas, frm mat, clr innr, 1/4" gap, 1/4" w 12 0.460
thk: 2 glazing, clr low-e outr, argon gas, vnl frm mat, clr innr, 1/4" gap,
1/4" thk; NFRC rated (SHGC=0.26); 50% blinds 45°, medium; 50%
outdoor insect screen; 1.5 ft overhang (2 ft window ht, 1 ft sep.); 6.67 ft
head ht
i
2 glazing, clr low-e outr, argon gas, vnl frm mat, clr innr, 1/4" gap, 1/4" w 20 0.490
thk: 2 glazing, clr low-e outr, argon gas, vnl frm mat, clr innr, 1/4" gap,
1/4" thk; NFRC rated (SHGC=0.24);'50% blinds 45°, medium; 50%
outdoor insect screen; 3 ft overhangl(5 ft window ht, 1 ft sep.); 6.67 ft
head ht
Doors
0 14.5 1044 10.5 757
0 13.3 160 24.0 288
0 14.2 284 20.5 410
11 DO: Door, wd sc type I n 24 0.390 0
Ceilings
16D-30td:Attic ceiling, tile, slate, c
gypsum board intfnsh
Floors
22A-tpm: Bg floor, heavy dry or ligh
fnsh
roof mat, r-30 cell ins, 1/2"
n 23 0.390 0
all 47 0.390 0
1899 0.032 30.0
11.3
271
11.4
274
11.3
256
11.4
259
11.3
528
11.4
533
0.93
1762
1.05
1993
t damp soil, on grade depth, tile fir 188 1.180 0 34.2 6436 0 0
+ wrightsoft® Right -Suite® Universal 2017 17.0.04 RS000269
�
..ulations\Skytec\Biscayni Grande Lot 53 GR N.rup Calc = MJ8 Front Door faces: N
I --
2017-Aug-30 16:24:29
Page 2
i
I
I
Project Summary
Entire House
For: i GHO Homes
2672 Conifer Drive, Fort Pierce, FL 34953
Job: Biscayne Grande Lot 53
Date: 6-13-17
By: Skyetec
Weather: St Lucie Co Intl, FL, US
Winter Design Conditions
Summer Design Conditions
Outside db 41 OF
Outside db
90
OF
Inside db 70 OF
Inside db
75
OF
Design TD 29 OF
Design TD
15
OF
Daily range
L
Relative humidity
50
%
Moisture difference
57
gr/lb
Heating Summary
Sensible Cooling Equipment Load Sizing
Structure 25567 Btuh
Structure
19078
Btuh
Ducts 6722 Btuh
Ducts
8078
Btuh
Central vent (0 cfm) 0 Btuh
Central vent (0 cfm)
0
Btuh
Humidification 0 Btuh
Blower
0
Btuh
Piping 0 Btuh
Equipment load 32289 Btuh
I
Use manufacturer's data
n
Rate/swing multiplier
0.95
Infiltration
Equipment sensible load
25906
Btuh
Method Simplified
Latent Cooling Equipment Load Sizing
Construction quality Average
Fireplaces 0
Structure
6787
Btuh
Ducts
2365
Btuh
Heating Cooling
Area (ft2) 1899 189
Central vent 0 cfm)
Equipment latent load
0
9152
Btuh
Btuh
Volume (ft3) 18422 18422
Air changes/hour 0.38 0.20
Equipment total load
35059
Btuh
Equiv. AVF (cfm) 117 61
Req. total capacity at 0.80 SHR
2.7
ton
Heating Equipment Summary
Cooling Equipment Summary
Make
Make Rheem
Trade
Trade RHEEM; RUUD
Model
Cond RA1642AJ1
AHRI ref
Coil RH1T4821STAN
AHRI ref 7942888
Efficiency 1 100 EFF
Efficiency 13.0 EER, 16 SEER
Heating input
12.3 kW
Sensible cooling
33200
Btuh
Heating output
41975 Btuh
Latent cooling
8300
Btuh
Temperature rise
28 OF
Total cooling
41500
Btuh
Actual air flow
1383 cfm
Actual air flow
1383
cfm
Air flow factor
0.043 cfm/Btuh
Air flow factor
0.051
cfm/Btuh
Static pressure 0.50 in H2O
Static pressure
0.50
in H2O
Space thermostat I
I
Load sensible heat ratio
0.75
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
`
2017-Aug-30 16:24:29
ACC"wrightsofI Right -Suite® Universal 2017 17.0.04 RS000269
Page 1
...ulations\Skytec\Biscayne Grande Lot 53 GR N.rup Calc = MJ8 Front Door
faces: N
Duct System Summary
Entire House
For: GHO Homes
2672 Conifer Drive, Fort Pierce, FL 34953
External static pressure
Pressure losses
Available static pressure
Supply / return available pr
Lowest friction rate
Actual air flow
Tnfml cf ar-fivc Icnnfh tTl=I \
Heating
0.50
in H2O
0.18
in H2O
0.32
in H2O
0.237 / 0.083
in H2O
0.101
in/100ft
1383
cfm
Job: Biscayne Grande Lot 53
Date: 6-13-17
By: skyetec
Cooling
0.50 in H2O
0.18 in H2O
0.32 in H2O
0.237 / 0.083 in H2O
0.101 in/100ft
1383 cfm
q1R ft
Name
Design
(Btuh�
Htg
(cfm)
Clg
(cfm)
Design
FIR
Diam
(in)
H x W
(in)
Duct
Matl
Actual
Ln (ft)
Ftg.Egv
Ln (ft)
Trunk
BR 2
C 3517
143
179
0.186
8.0
Ox 0
VIFx
7.3
120.0
st1
Bath 2
c 186
3
4
0.183
4.0
Ox 0
VIFx
10.1
120.0
st1
Den
h 4082
175
96
0.101
8.0
Ox 0
VIFx
44.3
190.0
st2
Dining
h 2644
113
110
0.108
7.0
Ox0
VIFx
33.9
185.0
st2
Foyer
h 1084
46
35
0.103
4.0
Ox0
VIFx
45.4
185.0
st2
Hers
c 60
2
3
0.117
4.0
Ox 0
VIFx
27.5
175.0
st3
His
h 1865
37
17
0.112
4.0
Ox 0
VIFx
32.0
180.0
st3
Kitchen
C 6686
266
341
0.103
10.0
Ox 0
VIFx
44.5
185.0
st2
Living
C 2083
82
106
0.110
6.0
Ox 0
VIFx
35.3
180.0
st3
Living•A
C 2083
82
106
0.109
6.0
Ox 0
VIFx
38.6
180.0
st3
M Bath
h �1598
68
64
0.112
5.0
Ox0
VIFx
32.3
180.0
st3
Master BR
h 3192
137
104
0.111
7.0
Ox 0
VIFx
34.8
180.0
st3
Master BR -A
h 3192
137
104
0.112
7.0
Ox 0
VIFx
32.3
180.0
st3
Utility
c 2148
89
109
0.182
7.0
Ox0
VIFx
10.4
120.0
st1
WC
c 30
1
2
0.113
4.0
Ox 0
VIFx
30.6
180.0
st3
WIC
c 48
2
2
0.184
4.0
Ox0
VIFx
9.1
120.0
st1
Trunk
Htg
Clg
Design
Veloc
Diam
H x W
Duct
Name
Type
(cfm)
(cfm)
FIR
(fpm)
(in)
(in)
Material
Trunk
st1
Peak AVF
1383
1383
0.101
634
20.0
0 x 0
VinlFlx
st2
Peak AVF
601
582
0.101
562
14.0
0 x 0
VinlFlx
st1
st3
Peak AVF
545
506
0.109
510
14.0
0 x 0
VINFlx
st1
I® 2017-Aug-30 16:24:30
- - wrightsoft Right-Suite(g) Universal 2017 17.0.04 RS000269 Page 1
...ulations\Skytec\BiscaynelGrande Lot 53 GR N.rup Calc = MJ8 Front Door faces: N
Grill
Htg
Clg
TEL
Design
Veloc
Diam
H x W
Stud/Joist
Duct
Name
Size (in)
(cfm)
(cfm)
(ft)
FIR
(fpm)
(in)
(in)
Opening (in)
Matl
Trunk
rb1
Ox0
1383
1383
81.5
0.101
634
20.0
Ox 0
VIFx
wri htsoft® 2017-Aug-30 16:24:30
9 Right -Suite® Universal 2017 17.0.04 RS000269 Page 2
...ulations\Skytec\Biscayne Grande Lot 53 GR N.rup Calc = MJ8 Front Door faces: N