HomeMy WebLinkAboutSoil Nuclear GaugeSoil Nuclear Gauge
Client:
Project:
Report Date: 9/22/2017
GHO Homes Corporation.
15-0338.00
Test Method: ASTM D 6938
590 NW Mercantile Place
IVlead�; owood;Golf�& CountwNlub:;
"FRNAT�HP
Port SL Lucie
Port St. Lucie, FL 34986.
Fort Pierce, Florida
FBPE CA 9 4930
607 NW Commodity Cove
Port St. Lucie; FL 34986
Phone: 772-924-36751 Fax: 772-924-3580
Test Results
Test #
Retest
Of
Test
Date
Proctor ID
Method
Soil
Classification
Optimum
Moisture
(%)
Maximum
Dry Density
(pcf)
In Place
Moisture
(°/a)
In Place
Dry Density
(pcf)
Probe
Depth
(in)
Percent
Compaction
Min/Max
Comp.
N
Remark
55
8122/17
P-2
N/A
%0
117.0
7.7
114.6
12
98
95 / 105
Pass
56
8/22/17
P-2
N/A
10.0
117.0
8.1
112.2
12
96
95 / 105
Pass
57
8/22/17
P-2
N/A
10.0
fl-7--01
7.9
1 115.9
1 12
99
95 / 105 1
Pass
Test Information
Test #
Test Location _
Elevation
Reference ,
Gauge
Make I Model / SN
Field Technician
55
Below Slab Grade'tLot;53, 2672 Conifer Drive, Fort Pierce`; foundation pad, northwest comer
0-1
Troxler 3430 29796
Liverman, Robert
56
Below Slab Grade: Lot 53, 2672 Conifer Drive, Fort Pierce, foundation pad, center area
0-1
Troxler 3430 29796
Liverman, Robert
57
Below Slab Grade: Lot 53, 2672 Conifer Drive, Fort Pierce, foundation pad, southeast corner
0-1
Troxler 3430 29796
Liverman, Robert
Remarks
I Comments
Pass: Tests results comply with specifications
Tests are "Direct Transmission" (Method A) unless probe depth is noted as
"Backscatter". Gauge calibration data on file with the testing agency.
'r�- 1-7 a --� - b 3y 8
Permit #1707-0348
RECEIVED
SEP 2 5 20V
PERMITTING
St. Lucie County, FL
%CE R
(\ 617
t�nfosTATE rth �4U`
Test Reports shall not be reproduced, except in full,. without the written approval of GFA International Inc. Page 1 of 1
Digitally signed printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies.