Loading...
HomeMy WebLinkAboutSublease Amendment ApprovalOrder Information Order ID Submitted By Original Submit Date JDE Job Number Revision Number 574871 Taylor Day Aug 24 2021 673492 0 Orders are subject to applicable Crown Castle engineering, regulatory, zoning/planning, and priority property-owner approval. Approval conditions may result in alternative requirements for type and/or placement of equipment. Approval conditions may also lead to additional or revised engineering analysis at Crown Castle discretion and upon consent of the customer. Site Information Site ID Crown Castle Structure Structure Height (ft) Crown Castle Site Name 813812 A 255.0 FL WEST FORT PIERCE Crown Castle District County FLA St. Lucie Latitude Longitude Structure Type Site Address 27° 26' 44.60" -80° 24' 46.60" SELF SUPPORT 8701 Orange Avenue Ft Pierce, FL 34945 Order Parameters Who is the customer? What do you want to do? License Number What is the Scope of your Order? Verizon Wireless Amend a License 101895 Tower Equipment Are you changing a mount? -- What is the scope of work? Swapping (3) Antennas, and adding (6) Antennas. Replacing (6) RRUS. Adding (1) OVP, (1) Hybrid. Removing (6) Coax. Final Config:: (12) Antennas, (6) RRUS, (2) OVP, (2) Hybrids, (6) Coax. Ground SOW: Remove IDE and install 19" rack. Customer Billing Company Billing ID Number Billing Address Verizon Wireless 111108 180 WASHINGTON VALLEY ROAD BEDMINSTER, NJ 07921 Operating Legal Entity Operating Legal Entity ID Alltel Corporation 1896246 Verizon Site Name Verizon Site Number Verizon Job Number NG # BAGGETT 237545 16247075 NG90711 Verizon Market Verizon Sub-Market SOUTH EAST FLORIDA Project Management Vendor Crown Castle - PMV Contacts NAME EMAIL PHONE ADDRESS Scott Henze scott.henze@verizonwireless.com RF Contacts There are currently no Contacts for this order. Page 1 &21), ' ( 17, $/ Configuration Review Antennas MCL (ft) ACL (ft) TOTAL INSTALLED PROPOSED NOT INSTALLED MANUFACTURER / MODEL HEIGHT (in) WIDTH (in) DEPTH (in) WEIGHT (lbs) 243 244 6 6 0 0 JMA WIRELESS / X7CQAP-665-VR0 72.00 14.60 7.30 57.80 247 3 0 3 0 ERICSSON / AIR 6449 B77 30.60 15.90 10.60 95.50 247 3 0 3 0 JMA WIRELESS / MX06FIT665-02 71.30 12.20 10.70 58.00 Tower Mounted Equipment MCL (ft) ACL (ft) TOTAL INSTALLED PROPOSED NOT INSTALLED MANUFACTURER / MODEL TYPE HEIGHT (in) WIDTH (in) DEPTH (in) WEIGHT (lbs) 243 247 1 1 0 0 RAYCAP / RXXDC-3315- PF-48 JUNCTION BOX 25.66 15.73 10.25 32.00 247 1 0 1 0 COMMSCOPE / RCMDC-6627-PF-48 JUNCTION BOX 29.50 16.50 12.60 32.00 247 3 0 3 0 ERICSSON / 4449 BASE STATION 17.90 13.20 9.40 70.50 247 3 0 3 0 ERICSSON / 8843 BASE STATION 15.00 13.20 10.90 71.90 Feedlines MCL (ft) ACL (ft) TOTAL INSTALLED PROPOSED NOT INSTALLED MANUFACTURER / MODEL NOMINAL SIZE (in) NOMINAL O.D. (in) 243 247 6 6 0 0 ANDREW / LDF7-50A 1-5/8 1.98 243 247 1 1 0 0 RFS/CELWAVE / HB114-13U6-S12F18 1-1/4 1.54 247 1 0 1 0 COMMSCOPE / HFT2406-48SV3-XXX 2 2.00 Frequencies SVC TECHNOLOGY EIRP (WATTS)STANDARD FREQUENCY TRANSMIT FREQUENCY CDMA 910.00 1950.000 -1955.000MHZ CDMA 242.00 880.000 - 894.000MHZ LTE 820.00 776.000 - 787.000MHZ LTE 120.00 2120.000 -2135.000MHZ All Receive frequencies are approved. Cabinets Number of Proposed Additional Cabinets 0 Lease Areas There are currently no Lease Areas for this order Power Do you need Crown to supply Power? No Battery Backup Required? No Page 2 &21), ' ( 1 7, $ / Equipment Order autopopulated from LMP(Installed Config) Antennas MANUFACTURER / MODEL ANTENNA CENTERLINE (ft) AZIMUTH CUSTOMER MOUNT CLASS MOUNT ORIENTATION STATUS JMA WIRELESS / X7CQAP-665-VR0 244 270 SECTOR MOUNT Mid-Mount Installed JMA WIRELESS / X7CQAP-665-VR0 244 30 SECTOR MOUNT Mid-Mount Installed JMA WIRELESS / X7CQAP-665-VR0 244 30 SECTOR MOUNT Mid-Mount Installed JMA WIRELESS / X7CQAP-665-VR0 244 150 SECTOR MOUNT Mid-Mount Installed JMA WIRELESS / X7CQAP-665-VR0 244 150 SECTOR MOUNT Mid-Mount Installed JMA WIRELESS / X7CQAP-665-VR0 244 270 SECTOR MOUNT Mid-Mount Installed ERICSSON / AIR 6449 B77 247 30 OTHER MOUNT Mid-Mount Proposed ERICSSON / AIR 6449 B77 247 150 OTHER MOUNT Mid-Mount Proposed ERICSSON / AIR 6449 B77 247 270 OTHER MOUNT Mid-Mount Proposed JMA WIRELESS / MX06FIT665-02 247 30 OTHER MOUNT Mid-Mount Proposed JMA WIRELESS / MX06FIT665-02 247 150 OTHER MOUNT Mid-Mount Proposed JMA WIRELESS / MX06FIT665-02 247 270 OTHER MOUNT Mid-Mount Proposed Tower Mounted Equipment TYPE MANUFACTURER / MODEL TME CENTERLINE (ft) LOCATED ON ANTENNA MOUNT? MOUNT CLASS STATUS JUNCTION BOX RAYCAP / RXXDC-3315-PF-48 247 Yes Installed BASE STATION ERICSSON / 4449 247 Yes Proposed BASE STATION ERICSSON / 4449 247 Yes Proposed BASE STATION ERICSSON / 4449 247 Yes Proposed BASE STATION ERICSSON / 8843 247 Yes Proposed BASE STATION ERICSSON / 8843 247 Yes Proposed BASE STATION ERICSSON / 8843 247 Yes Proposed JUNCTION BOX COMMSCOPE / RCMDC-6627-PF-48 247 Yes Proposed Page 3 &21), ' ( 1 7, $ / Feedlines TYPE MANUFACTURER / MODEL NOMINAL SIZE (in) ATTACHED CENTERLINE (ft) LENGTH (ft) IN CONDUIT?STATUS HYBRID RFS/CELWAVE / HB114-13U6-S12F18 1-1/4 247 297 No Installed COAX ANDREW / LDF7-50A 1-5/8 247 297 No Installed COAX ANDREW / LDF7-50A 1-5/8 247 297 No Installed COAX ANDREW / LDF7-50A 1-5/8 247 297 No Installed COAX ANDREW / LDF7-50A 1-5/8 247 297 No Installed COAX ANDREW / LDF7-50A 1-5/8 247 297 No Installed COAX ANDREW / LDF7-50A 1-5/8 247 297 No Installed HYBRID COMMSCOPE / HFT2406-48SV3-XXX 2 247 297 No Proposed NOTICE: Structural Analysis shall be performed in accordance with the current revision of the TIA/EIA 222 standard and applicable local building permit codes and standards. EME analysis shall be consistent with current revision of FCC/OSHA standard OETB 65. AM detuning, when required, will be performed to 47 CFR22.371. The customer is responsible for all analysis expenses. All construction drawings are subject to Crown Castle engineering approval prior to commencement of tower attachments and compound installations. Installation of equipment not conforming to approved drawings may violate the terms of the occupancy agreement and will be corrected at the customer's expense. Crown Castle requires drawings for pre-construction approval and as built drawings for physical configuration validation to be submitted as unlocked AutoCAD files (Version 2000i preferred). Because manufacturers may change equipment specifications (e.g., length, width, height, depth or weight) for a Model Number without changing the Model Number itself, the equipment specifications for such Model Number as identified herein shall be used to determine exactly which version of equipment with such Model Number is approved by Crown Castle herein. Crown Castle may include the suffix “CCIv” together with a number (indicating a version number) after a Model Number, which suffix is not part of the actual Model Number, but indicative of a known change to the equipment specifications applicable to such Model Number. Page 4 &21), ' ( 1 7, $ /