HomeMy WebLinkAboutSublease Amendment ApprovalOrder Information
Order ID Submitted By Original Submit Date JDE Job Number Revision Number
574871 Taylor Day Aug 24 2021 673492 0
Orders are subject to applicable Crown Castle engineering, regulatory, zoning/planning, and priority property-owner approval. Approval conditions may result in alternative
requirements for type and/or placement of equipment. Approval conditions may also lead to additional or revised engineering analysis at Crown Castle discretion and upon
consent of the customer.
Site Information
Site ID Crown Castle Structure Structure Height (ft) Crown Castle Site Name
813812 A 255.0 FL WEST FORT PIERCE
Crown Castle District County
FLA St. Lucie
Latitude Longitude Structure Type Site Address
27° 26' 44.60" -80° 24' 46.60" SELF SUPPORT 8701 Orange Avenue
Ft Pierce, FL 34945
Order Parameters
Who is the customer? What do you want to do? License Number What is the Scope of your Order?
Verizon Wireless Amend a License 101895 Tower Equipment
Are you changing a mount?
--
What is the scope of work?
Swapping (3) Antennas, and adding (6) Antennas. Replacing (6) RRUS. Adding (1) OVP,
(1) Hybrid. Removing (6) Coax.
Final Config:: (12) Antennas, (6) RRUS, (2) OVP, (2) Hybrids, (6) Coax.
Ground SOW: Remove IDE and install 19" rack.
Customer
Billing Company Billing ID Number Billing Address
Verizon Wireless 111108 180 WASHINGTON VALLEY
ROAD
BEDMINSTER, NJ 07921
Operating Legal Entity Operating Legal Entity ID
Alltel Corporation 1896246
Verizon Site Name Verizon Site Number Verizon Job Number NG #
BAGGETT 237545 16247075 NG90711
Verizon Market Verizon Sub-Market
SOUTH EAST FLORIDA
Project Management Vendor
Crown Castle - PMV
Contacts
NAME EMAIL PHONE ADDRESS
Scott Henze scott.henze@verizonwireless.com
RF Contacts
There are currently no Contacts for this order.
Page 1
&21),
'
(
17,
$/
Configuration Review
Antennas
MCL
(ft)
ACL
(ft)
TOTAL INSTALLED PROPOSED NOT
INSTALLED
MANUFACTURER / MODEL HEIGHT
(in)
WIDTH
(in)
DEPTH
(in)
WEIGHT
(lbs)
243 244 6 6 0 0 JMA WIRELESS / X7CQAP-665-VR0 72.00 14.60 7.30 57.80
247 3 0 3 0 ERICSSON / AIR 6449 B77 30.60 15.90 10.60 95.50
247 3 0 3 0 JMA WIRELESS / MX06FIT665-02 71.30 12.20 10.70 58.00
Tower Mounted Equipment
MCL
(ft)
ACL
(ft)
TOTAL INSTALLED PROPOSED NOT
INSTALLED
MANUFACTURER / MODEL TYPE HEIGHT
(in)
WIDTH
(in)
DEPTH
(in)
WEIGHT
(lbs)
243 247 1 1 0 0 RAYCAP / RXXDC-3315-
PF-48
JUNCTION
BOX
25.66 15.73 10.25 32.00
247 1 0 1 0 COMMSCOPE /
RCMDC-6627-PF-48
JUNCTION
BOX
29.50 16.50 12.60 32.00
247 3 0 3 0 ERICSSON / 4449 BASE
STATION
17.90 13.20 9.40 70.50
247 3 0 3 0 ERICSSON / 8843 BASE
STATION
15.00 13.20 10.90 71.90
Feedlines
MCL
(ft)
ACL
(ft)
TOTAL INSTALLED PROPOSED NOT
INSTALLED
MANUFACTURER / MODEL NOMINAL SIZE
(in)
NOMINAL O.D.
(in)
243 247 6 6 0 0 ANDREW / LDF7-50A 1-5/8 1.98
243 247 1 1 0 0 RFS/CELWAVE / HB114-13U6-S12F18 1-1/4 1.54
247 1 0 1 0 COMMSCOPE / HFT2406-48SV3-XXX 2 2.00
Frequencies
SVC TECHNOLOGY EIRP (WATTS)STANDARD FREQUENCY TRANSMIT FREQUENCY
CDMA 910.00 1950.000 -1955.000MHZ
CDMA 242.00 880.000 - 894.000MHZ
LTE 820.00 776.000 - 787.000MHZ
LTE 120.00 2120.000 -2135.000MHZ
All Receive frequencies are approved.
Cabinets
Number of Proposed Additional Cabinets
0
Lease Areas
There are currently no Lease Areas for this order
Power
Do you need Crown to supply Power?
No
Battery Backup Required?
No
Page 2
&21),
'
(
1
7,
$
/
Equipment Order autopopulated from LMP(Installed Config)
Antennas
MANUFACTURER / MODEL ANTENNA
CENTERLINE
(ft)
AZIMUTH CUSTOMER
MOUNT CLASS
MOUNT
ORIENTATION
STATUS
JMA WIRELESS / X7CQAP-665-VR0 244 270 SECTOR
MOUNT
Mid-Mount Installed
JMA WIRELESS / X7CQAP-665-VR0 244 30 SECTOR
MOUNT
Mid-Mount Installed
JMA WIRELESS / X7CQAP-665-VR0 244 30 SECTOR
MOUNT
Mid-Mount Installed
JMA WIRELESS / X7CQAP-665-VR0 244 150 SECTOR
MOUNT
Mid-Mount Installed
JMA WIRELESS / X7CQAP-665-VR0 244 150 SECTOR
MOUNT
Mid-Mount Installed
JMA WIRELESS / X7CQAP-665-VR0 244 270 SECTOR
MOUNT
Mid-Mount Installed
ERICSSON / AIR 6449 B77 247 30 OTHER MOUNT Mid-Mount Proposed
ERICSSON / AIR 6449 B77 247 150 OTHER MOUNT Mid-Mount Proposed
ERICSSON / AIR 6449 B77 247 270 OTHER MOUNT Mid-Mount Proposed
JMA WIRELESS / MX06FIT665-02 247 30 OTHER MOUNT Mid-Mount Proposed
JMA WIRELESS / MX06FIT665-02 247 150 OTHER MOUNT Mid-Mount Proposed
JMA WIRELESS / MX06FIT665-02 247 270 OTHER MOUNT Mid-Mount Proposed
Tower Mounted Equipment
TYPE MANUFACTURER / MODEL TME CENTERLINE
(ft)
LOCATED ON
ANTENNA MOUNT?
MOUNT CLASS STATUS
JUNCTION
BOX
RAYCAP / RXXDC-3315-PF-48 247 Yes Installed
BASE
STATION
ERICSSON / 4449 247 Yes Proposed
BASE
STATION
ERICSSON / 4449 247 Yes Proposed
BASE
STATION
ERICSSON / 4449 247 Yes Proposed
BASE
STATION
ERICSSON / 8843 247 Yes Proposed
BASE
STATION
ERICSSON / 8843 247 Yes Proposed
BASE
STATION
ERICSSON / 8843 247 Yes Proposed
JUNCTION
BOX
COMMSCOPE / RCMDC-6627-PF-48 247 Yes Proposed
Page 3
&21),
'
(
1
7,
$
/
Feedlines
TYPE MANUFACTURER / MODEL NOMINAL SIZE
(in)
ATTACHED
CENTERLINE
(ft)
LENGTH
(ft)
IN CONDUIT?STATUS
HYBRID RFS/CELWAVE / HB114-13U6-S12F18 1-1/4 247 297 No Installed
COAX ANDREW / LDF7-50A 1-5/8 247 297 No Installed
COAX ANDREW / LDF7-50A 1-5/8 247 297 No Installed
COAX ANDREW / LDF7-50A 1-5/8 247 297 No Installed
COAX ANDREW / LDF7-50A 1-5/8 247 297 No Installed
COAX ANDREW / LDF7-50A 1-5/8 247 297 No Installed
COAX ANDREW / LDF7-50A 1-5/8 247 297 No Installed
HYBRID COMMSCOPE / HFT2406-48SV3-XXX 2 247 297 No Proposed
NOTICE: Structural Analysis shall be performed in accordance with the current revision of the TIA/EIA 222 standard and applicable local building permit codes and standards.
EME analysis shall be consistent with current revision of FCC/OSHA standard OETB 65. AM detuning, when required, will be performed to 47 CFR22.371. The customer
is responsible for all analysis expenses. All construction drawings are subject to Crown Castle engineering approval prior to commencement of tower attachments and
compound installations. Installation of equipment not conforming to approved drawings may violate the terms of the occupancy agreement and will be corrected at the
customer's expense. Crown Castle requires drawings for pre-construction approval and as built drawings for physical configuration validation to be submitted as unlocked
AutoCAD files (Version 2000i preferred). Because manufacturers may change equipment specifications (e.g., length, width, height, depth or weight) for a Model Number
without changing the Model Number itself, the equipment specifications for such Model Number as identified herein shall be used to determine exactly which version of
equipment with such Model Number is approved by Crown Castle herein. Crown Castle may include the suffix “CCIv” together with a number (indicating a version number)
after a Model Number, which suffix is not part of the actual Model Number, but indicative of a known change to the equipment specifications applicable to such Model Number.
Page 4
&21),
'
(
1
7,
$
/