Loading...
HomeMy WebLinkAboutApplication For Construction Permit("E STATE OF FLORIDA DEPARTMENT OF HEALTH ` T '� a3 ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM COp WE.``� APPLICATION FOR CONSTRUCTION PERMIT APPLICATION FOR: New System [ ] Existing System [ ] Holding Tank [ ] Repair [ ] Abandonment [ ], Temporary APPLICANT: CELESTINO FUENTES PONCE AGENT: Alexander J. Piazza PSM, Inc. MAILING ADDRESS: 619 SW Biltmore Street, Port St. Lucie, Florida 34983 PERMIT NO. 50,SFA 11OJ DATE PAID: a "I FEE PAID: RECEIPT #:-��1 [ ] Innovative TELEPHONE: 772-340-7770 TO BE COMPLETED BY APPLICANT OR APPLICANT'S AUTHORIZED AGENT. SYSTEMS MUST BE CONSTRUCTED BY A PERSON LICENSED PURSUANT TO 489.105(3)(m) OR 489.552, FLORIDA STATUTES. IT IS THE APPLICANT'S RESPONSIBILITY TO PROVIDE DOCUMENTATION OF THE DATE THE LOT WAS CREATED OR PLATTED (MM/DD/YY) IF REQUESTING CONSIDERATION OF STATUTORY GRANDFATHER PROVISIONS. PROPERTY INFORMATION LOT: - BLOCK: - SUBDIVISION: NOT PLATTED PLATTED: PROPERTY ID # : 2309-122-0000-000-9 ZONING: R I /M OR EQUIVALENT: [ No ] PROPERTY SIZE: 12.10 ACRES WATER SUPPLY: [,(] PRIVATE PUBLIC [ ]<=2000GPD [ ]>2000GPD IS SEWER AVAILABLE AS PER 381.0065, FS? [ No ] DISTANCE TO SEWER: FT PROPERTY ADDRESS: BERGER ROAD, Fort Pierce, Florida 34945 DIRECTIONS TO PROPERTY: SEE MAP BUILDING INFORMATION Unit Type of No Establishment 1 RESIDENCE 2 3 4 [v/] RESIDENTIAL [ ] COMMERCIAL No. of Building Commercial/Institutional System Design Bedrooms Area Sqft Table 1, Chapter 64E-6, FAC 4 3,436 [ ] Floor/Equipment Drains [ ,/ ] Other (Specify) GARBAGE GRINDERS / DISPOSALS UlRimlly rirA.J by Al..dlr J Pi — Alexander J Piazza PINUS. -L;.f,1W.,..-AOIJ27000IIOO165R ICIJC90000019RI,m-Al..&rJ m,,, SIGNATURE : 1br.2ms.12.1s09:44a2-0sm• DATE* 12-18-18 DH 4015, 08/09 (Obsoletes previous editions which may not be used) Incorporated 64E-6.001, FAC Page 1 of 4 STATE OF FLORIDA DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM SITE EVALUATION AND SYSTEM SPECIFICATION APPLICANT: Celestino Ponce CONTRACTOR / AGENT: Alexander J. Piazza PSM, Inc John Erickson 772-260-5049 LOT: BLOCK: SUBDIVISION: ID# : 2309-122-0000-000-9 APPLICATION # AP1389929 PERMIT # 56-SF-1841839 DOCUMENT # SE1147199 TO BE COMPLETED BY ENGINEER,• HEALTH, DEPARTMENT EMPLOYEE, OR OTHER QUALIFIED PERSON. ENGINEERS MUST PROVIDE REGISTRATION NUMBER AND SIGN AND SEAL EACH PAGE OF SUBMITTAL. COMPLETE ALL ITEMS. PROPERTY SIZE CONFORMS TO SITE PLAN: [X]YES [ ]NO NET USABLE AREA AVAILABLE: 12.10 ACRES TOTAL ESTIMATED SEWAGE FLOW: 460 GALLONS PER DAY [ RESIDENCES -TABLET / OTHER -TABLE 2 ] AUTHORIZED SEWAGE FLOW: 18150.00 GALLONS PER DAY [ 1500 GPD/ACRE OR 2500 GPD/ACRE ] UNOBSTRUCTED AREA AVAILABLE: 1200.00 SQFT UNOBSTRUCTED AREA REQUIRED: 1150.00 SQFT BENCHMARK/REFERENCE POINT LOCATION: site BM red Capped IR N Of system ELEVATION OF PROPOSED SYSTEM SITE 4.00 [ INCHES / FT ] [ ABOVE / BENCHMARK/REFERENCE POINT THE MINIMUM SETBACK WHICH CAN BE MAINTAINED FROM THE PROPOSED SYSTEM TO THE FOLLOWING FEATURES SURFACE WATER: 75 FT DITCHES/SWALES: 75 FT NORMALLY WET: [ ]YES [X]NO WELLS: PUBLIC: FT LIMITED USE: FT PRIVATE: 100 FT NON -POTABLE: 100 FT BUILDING FOUNDATIONS: 5 FT PROPERTY LINES: 50 FT POTABLE WATER LINES: 75 FT SITE SUBJECT TO FREQUENT FLOODING? [ ]YES [X]NO 10 YEAR FLOODING? [ ]YES [X]NO] 10 YEAR FLOOD ELEVATION FOR SITE: FT[ MSL / NGVD ] SITE ELEVATION: FT [ MSL / NGVD SOIL PROFILE INFORMATION SITE 1 SOTL PROFILE TNFORMATTON STTE 2 USDA SOIL SERIES:Nettles sand Munsell #/Color Texture Depth 1 OYR 4/2 Sand 0 To 11 10YR 5/1 Sand 11 To 29 10YR 6/1 Sand 23 To 29 1 OYR 2/1 Spodic Material 29 To 34 10YR 3/3 Sand 34 To 38 10YR 3/3 Loamy Sand 38 To 47 10YR 4/4 Sand 47 To 54 10YR 5/2 Sand 54 To 72 USDA SOIL SERIES:Oldsmar sand Munsell #/Color Texture Depth 10YR 4/2 Sand 0 To 10 10YR 5/1 Sand 10 To 35 10YR 6/2 Sand 25 To 35 1 OYR 3/2 Sand 35 To 44 10YR 5/3 Loamy Sand 44 To 46 5GY 5/1 Loamy Sand 46 To 60 5GY 511 Sand 60 To 72 OBSERVED WATER TABLE: 70.00 INCHES -[ ABOVE / BELOW ] EXISTING GRADE TYPE: ESTIMATED WET SEASON WATER TABLE ELEVATION: 23 INCHES C ABOVE / BELOW ] HIGH WATER TABLE VEGETATION: [ ]YES EX ]NO MOTTLING: [X]YES [ ]NO SOIL TEXTURE/LOADING RATE FOR SYSTEM SIZING: Sand/0.60 DEPTH OF E= DRAINFIELD CONFIGURATION: [ ] TRENCH [X ] BED [ ] OTHER (SPECIFY) - REMARKS/ADDITIONAL CRITERIA WSWT determined using USDA WSS and soil borings. 10YR6/1 stripping in 10YR5/1 matrix >10% with diffuse boundaries starting at 23" in SB1. SB1 and SB2 4"below BM. SITE EVALUATED BY: Ingram, Brian (TiWEnvironmental Specialist II) (ENVIRONMENTAL HEALTH) DH 4015, 08/09 (Obsoletes previous editions which may not be used) Incorporated: 64E-6.001, FAC C PERCHED / APPARENT ] EXISTING GRADE DEPTH: 23.00 INCHES NTION: 34 INCHES DATE: 01 /04/2019 Page 3 of 4 AP1389929 EID1841839 v1.0.2 zttE �X STATE OF FLORIDA PERMIT # . DEPARTMENT OF HEALTH '�•/ ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM .�,,� ,;' SITE EVALUATION AND SYSTEM SPECIFICATIONS APPLICANT: CELESTINO FUENTES PONCE AGENT: Alexander J. Piazza PSM, Inc. LOT: - BLOCK: - SUBDIVISION: NOT PLATTED PROPERTY ID # : 2309-122-0000-000-9 [ Tax ID Number TO BE COMPLETED BY ENGINEER, HEALTH DEPARTMENT EMPLOYEE,OR OTHER QUALIFIED PERSON. ENGINEERS MUST PROVIDE REGISTRATION NUMBER AND SIGN AND SEAL EACH PAGE OF SUBMITTAL. COMPLETE ALL ITEMS. PROPERTY SIZE CONFORMS TO SITE PLAN: [✓] TOTAL ESTIMATED SEWAGE FLOW: 767 AUTHORIZED SEWAGE FLOW: UNOBSTRUCTED AREA AVAILABLE: 1200 BENCHMARK/REFERENCE POINT LOCATION: ELEVATION OF PROPOSED SYSTEM SITE IS 34 YES [ ] NO NET USABLE AREA AVAILABLE: _GALLONS PER DAY [ RESIDENCES -TABLE 1 /OTHER -TABLE 2 _GALLONS PER DAY [ 1500 GPD/ACRE OR 2500 GPD/ACRE SQFT UNOBSTRUCTED AREA REQUIRED: 1200 ACRES SQFT [ INCHES / FT ] [ABOVE/BELOW'] BENCHMARK/REFERENCE POINT THE MINIMUM SETBACK WHICH CAN BE MAINTAINED FROM THE PROPOSED SYSTEM TO THE FOLLOWING FEATURES SURFACE WATER:100 FT DITCHES/SWALES:15 FT NORMALLY WET? [ ] YES [�/] NO WELLS: PUBLIC: 200 FT LIMITED USE: 100 FT PRIVATE: 75 FT NON —POTABLE: 100 FT BUILDING FOUNDATIONS:5 FT PROPERTY LINES:10 FT POTABLE WATER LINES: FT SITE SUBJECT TO FREQUENT FLOODING: [ ] YES [✓] NO 10 YEAR FLOODING? [ ] YES j✓] NO 10 YEAR FLOOD ELEVATION FOR SITE: FT MSL/NGVD SITE ELEVATION: FT MSL/NGVD SOIL PROFILE INFORMATION SITE 1 MUNSELL #/COLOR TEXTURE DEPTH TO TO TO TO TO TO TO TO TO USDA SOIL SERIES: OBSERVED WATER TABLE:40+ INCHES [BELOW ESTIMATED WET SEASON WATER TABLE ELEVATION:_ HIGH WATER TABLE VEGETATION: [ ] YES [ ] NO SOIL TEXTURE/LOADING RATE FOR SYSTEM SIZING: DRAINFIELD CONFIGURATION: [v/] TRENCH [ ] REMARKS/ADDITIONAL CRITERIA: BED SOIL PROFILE INFORMATION SITE 2 MUNSELL #/COLOR TEXTURE DEPTH TO TO TO TO TO TO TO TO TO USDA SOIL SERIES: �] EXISTING GRADE. TYPE:[ PERCHED/ APPARENT ] _ INCHES ABOVE BELOW ] EXISTING GRADE MOTTLING: [ ] YES [ ] NO DEPTH: INCHES DEPTH OF EXCAVATION: ] OTHER (SPECIFY) INCHES oyiv�y d�nm M nm� a,. � vma. Alexander J Piazza ova°»E OOOIb58iEE]C96WWI981, mRN u+MJPYm SITE EVALUATED BY: wle:nial:Isoe a:u.mnu DATE: 12-18-18 DH 4015, 12/11 (Obsoletes previous editions which may not be used) Incorporated: 64E-6.001, FAC Page 3 of 4 �jC� APPLICANT'S NAME: CELESTINO FUENTES PONCE - SF- LEGAL DESCRIPTION: NOT PLATTED PIP# 2309-122-0000-000-9' I certify that there are no potable private wells within 75 feet of .the available area for the proposed septic system, that there are no non -potable wells within 50 feet of the available area for the proposed septic system, that there are no wells within 25 feet of a pesticide -treated building foundation, that there are no public wells that serve less than 25 people or less than 15 homes or businesses within 100 feet of the proposed septic system, that there are no public wells that serve more than 25 people or more than 15 homes or businesses within 200 feet of the proposed septic system, that the water line from the- water meter or well to the structure is at least 10 feet_from the available area for the proposed septic system unless the plans show the line to be double sleeved, that there is not a gravity sewer line, low pressure sewer line or vacuum sewage line in a public easement or right-of-way that abuts the property, that there are no lakes, streams, wetlands, or surface water within 75 feet of the available area for the proposed septic system unless the property was created prior to 1972, that the septic system is proposed on the side of the lot farthest from surface water, that all private wells, septic systems and surface water on adjacent or contiguous land within 75 feet of the applicant's lot are shown on the site plan, that all public wells within 200 feet of the applicant's lot are shown on the site plan, and that the location of building or residences, swimming pools, recorded easements, paved areas or driveways, sidewalks, the general slope of the property, filled areas, drainage features, and surface waters such as lakes, ponds, streams, canals, or wetlands are shown on the applicants lot. The natural grade elevation in the area of the proposed septic system and the benchmark must be shown on the site plan. Please locate the benchmark within 200 feet of the proposed septic system. NOTE: MUST BE CERTIFIED BY A FLORIDA REGISTERED SURVEYOR OR ENGINEER. CERTIFIED BY: FLORIDA PROFESSIONAL O.: DATE: 04/12/18 1 JOB NO.: 14-1918 docs/ rormstseptics/SepticApppPage207