Loading...
HomeMy WebLinkAboutEnergy Efficiency Code 1-2-19FORM R405-2017 FTLE COPY FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 619 Berger Rd Builder Name: ALPHA DESIGN CONTRACTOR LLC Street: 619 BERGER RD Permit Office: ST LUCIE COUNTY City, State, Zip: Fort Pierce , FL , Permit Number: Owner: Jurisdiction: 6611000 Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (3085.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.0 3085.00 ftz b. N/A R= ftz 3. Number of units, if multiple family 1 c. N/A R= ftz 4. Number of Bedrooms 4 d. N/A R= ftz 10. Ceiling Types (3436.0 sqft.) Insulation Area 5. Is this a worst case? No a. Roof Deck (Unvented) R=20.0 3436.00 ftz 6. Conditioned floor area above grade (ftz) 3436 b. N/A R= ftz Conditioned floor area below grade (ftz) 0 c. N/A R= ftz 11. Ducts R ftz 7. Windows(671.8 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Main 6 687.2 a. U-Factor: Dbl, U=0.58 501.17 ftz SHGC: SHGC=0.24 b. U-Factor: Dbl, U=0.58 170.67 ftz 12. Cooling systems kBtEfficiency SHGC: SHGC=0.17 a. Central Unit 69.1 .1 SEER:16.00 c. U-Factor: N/A ftz SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ftz a. Electric Strip Heat 60.0 COP:50.00 SHGC: Area Weighted Average Overhang Depth: 6.597 ft. Area Weighted Average SHGC: 0.222 14. Hot water systems a. Electric Cap: 40 gallons 8. Floor Types (3436.0 sqft.) Insulation Area EF: 0.980 a. Slab -On -Grade Edge Insulation R=0.0 3436.00 ftz b. Conservation features b. N/A R= fl2 None c. N/A R= ftz 15. Credits CF, Pstat Glass/Floor Area: 0.196 Total Proposed Modified Loads: 115.25 PASS Total Baseline Loads: 115.37 1 hereby certify that the plans and specifications covered by Review of the plans and 0Irt-RE Sr'4?� this calculation are in compliance 'th th Florida Ener y specifications covered by this indicates �r ; ;_ Off, _,.•�';,o�`� Code. calculation compliance yrc+ �r�,sJ,` with the Florida Energy Code. PREPARED BY: DATE: 6 Before construction is completed this building will be inspected for compliance with Section 553.908 I hereby certify that this building, as designed, is c pliance Florida Statutes. with the Florida Energy Code. ( Op WEB OWNER/AGQ�T .�-' f BUILDING OFFICIAL: DATE. DATE: - Compliance requires certification by the air handler unit manufacturer that -the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). 1/4/2019 7:55 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: Building Type: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: 619 Berger Rd Bedrooms: 4 User Conditioned Area: 3436 Total Stories: 1 1 Worst Case: No ALPHA DESIGN CONTRACT Rotate Angle: 0 ST LUCIE COUNTY Cross Ventilation: 6611000 Whole House Fan: Single-family New (From Plans) Address Type: Street Address Lot # Block/Subdivision: PlatBook: Street: 619 BERGER RD County: St. Lucie City, State, Zip: Fort Pierce , FL, CLIMATE V Design Location Design Temp TMY Site 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Blockl 3436 32985.6 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 3436 32985.6 Yes 6 4 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 306 ft 0 3436 ftz ---- 0 0. 1 ROOF / V # Roof Gable Roof Type Materials Area Area Color Rad Barr Solar SA Emitt Emitt Deck Pitch Absor. Tested Tested Insul. (deg) 1 Hip Metal 3722 ftz 0 ft2 Unfinishe N 0.35 No 0.4 No 20 22.6 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 3436 ftz N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Unvented) Main 0 Blown 3436 ftz 0.11 Wood 1/4/2019 7:55 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Space Cavity EL-Vallie Width Ft In Height Et In Area Sheathing Framing R-Vallla Erection Solar A Below 1 W Exterior Concrete Block - Int Insul Main 4 24 4 9 6 231.2 ft2 0 0.75 0 2 W Exterior Concrete Block - Int insul Main 4 50 5 9 4 470.6 ft2 0 0.75 0 3 NW Exterior Concrete Block - Int Insul Main 4 7 9 4 65.3 ft2 0 0.75 0 4 N Exterior Concrete Block - Int Insul Main 4 18 4 9 6 174.2 ft2 0 0.75 0 5 N Exterior Concrete Block - Int Insul Main 4 53 3 9 4 497.0 ft2 0 0.75 0 6 E Exterior Concrete Block - Int Insul Main 4 13 4 9 4 124.4 ft2 0 0.75 0 7 E Exterior Concrete Block - Int Insul Main 4 37 9 4 345.3 ft2 0 0.75 0 8 E Exterior Concrete Block - Int Insul Main 4 17 4 9 4 161.8 ft2 0 0.75 0 9 NE Exterior Concrete Block - Int Insul Main 4 4 5 9 4 41.2 ft2 0 0.75 0 10 SE Exterior Concrete Block - Int Insul Main 4 4 5 9 4 41.2 ft2 0 0.75 0 11 S Exterior Concrete Block - Int Insul Main 4 35 2 9 4 328.2 ft2 0 0.75 0 12 S Exterior Concrete Block - Int Insul Main 4 40 8 9 4 379.6 ft2 0 0.75 0 13 E Exterior Concrete Block - Int Insul Main 4 30 7 6 225.0 ft2 0 0.75 0 DOORS # Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 N Insulated Main None .21 36 96 24 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. / Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 W 1 Metal Low-E Double Yes 0.58 0.24 Y 36.0 f12 2 ft 0 in 1 ft 0 in None None 2 W 2 Metal Low-E Double Yes 0.58 0.24 Y 57.0 ft2 8 ft 0 in 1 ft 0 in None None 3 W 2 Metal Low-E Double Yes 0.58 0.24 Y 31.7 ft2 8 ft 0 in 1 ft 0 in None None 4 W 2 Metal Low-E Double Yes 0.58 0.17 Y 85.3 ft2 8 ft 0 in 1 ft 0 in None None 5 NW 3 Metal Low-E Double Yes 0.58 0.24 Y 19.0 ft2 10 It 0 in 1 ft 0 in None None 6 N 4 Metal Low-E Double Yes 0.58 0.17 Y 42.7 ft2 12 It 0 in 1 ft 0 in None None 7 W 2 Metal Low-E Double Yes 0.58 0.24 Y 11.3 ft2 8 ft 0 in 1 ft 0 in None None 8 N 5 Metal Low-E Double Yes 0.58 0.24 Y 22.5 ft2 2 ft 0 in 1 ft 0 in None None 9 N 5 Metal Low-E Double Yes 0.58 0.24 Y 6.8 ft2 2 ft 0 in 1 ft 0 in None None 10 E 6 Metal Low-E Double Yes 0.58 0.24 Y 11.3 ft2 2 It 0 in 1 ft 0 in None None 11 E 6 Metal Low-E Double Yes 0.58 0.24 Y 36.0 ft2 2 It 0 in 1 ft 0 in None None 12 E 7 Metal Low-E Double Yes 0.58 0.24 Y 95.0 ft2 10 ft 0 in 1 ft 0 in None None 13 E 8 Metal Low-E Double Yes 0.58 0.24 Y 36.0 ft2 2 ft 0 in 1 ft 0 in None None 14 NE 9 Metal Low-E Double Yes 0.58 0.24 Y 19.0 ft2 10 ft 0 in 1 ft 0 in None None 15 SE 10 Metal Low-E Double Yes 0.58 0.24 Y 19.0 ft2 10 ft 0 in 1 ft 0 in None None 16 S 11 Metal Low-E Double Yes 0.58 0.24 Y 6.8 ft2 2 ft 0 in 1 ft 0 in None None 17 E 8 Metal Low-E Double Yes 0.58 0.24 Y 25.3 ft2 2 ft 0 in 1 ft 0 in None None 18 S 12 Metal Low-E Double Yes 0.58 0.24 Y 13.0 ft2 8 ft 0 in 1 ft 0 in None None 19 S 12 Metal Low-E Double Yes 0.58 0.17 Y 42.7 ft2 8 ft 0 in 1 ft 0 in None None 20 E 13 Metal Low-E Double Yes 0.58 0.24 Y 45.0 ft2 2 ft 0 in 1 ft 0 in None None 21 E 13 Metal Low-E Double Yes 0.58 0.24 Y 10.7 ft2 2 ft 0 in 1 ft 0 in None None 1/4/2019 7:55 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000305 2748.8 150.91 283.8 .1137 5 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 A 1 B Electric Strip Heat/ Electric Strip Heatt None None COP:50 34 kBtu/hr COP:50 26 kBtu/hr 1 1 sys#1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 A 1 B Central Unit/ Central Unit/ None None SEER: 16 41.5 kBtu/hr 1245 cfm 0.8 SEER: 16 27.6 kBtu/hr 828 cfm 0.8 1 1 sys#1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Main 0.98 40 gal 70 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector Storage System Model # Collector Model # Area Volume FEF None None ft2 DUCTS / v # — Supply — Location R-Value Area — Return— Air CFM 25 CFM25 Location Area Leakage Type Handler TOT OUT QN RLF HVAC # Heat Cool 1 Attic 6 687.2 ft Attic 171.8 ft Default Leakage Main (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y CoolingJan Feb Mar HeatinHJan HFeb Mar Ventin Jan Feb X Mar Ceiling Fans: r may rj Jun�Xj Jul rl Au rl Se Oct Oct pr L May Jun Jul AuSep W A r [ Ma Jun Jul Aug Se Oct Nov Nov Nov H Dec Dec H Dec 1/4/2019 7:55 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating(WD) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Defauft(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 Main 1/4/2019 7:55 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 5 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* =100 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Main 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 4 13. Cooling system: Capacity 69.1 a) Split system SEER 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 3436 d) Room unit/PTAC EER e) Other 16.0 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.580 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.222 14. Heating system: Capacity 60.0 c) Area 7c. 671.8 a) Split system heat pump HSPF b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP 50.0 a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.98 b) Gas fired, natural gas EFL 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF 2. Masonry (Insulation R-value) 10A2. 4.0 0 Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10131. 2. Masonry (Insulation R-value) 10132. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans Yes a) Under attic 11 a. 0.0 b) Cross ventilation No b) Single assembly 11 b. c) Whole house fan No c) Knee walls/skylight walls 11c. d) Multizone cooling credit d) Radiant barrier installed 11 d. No e) Multizone heating credit 0 Programmable thermostat Yes `Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on ins�ed code compliant features. Builder Signature: _ ' l Date: U Address of New Home: 619 BERGER RD City/FL Zip: Fort Pierce, FL 1/4/2019 7:56:04 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 Envelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: 6611000 Permit #: ✓'i++prhivpy'#F '1}'FWkIS Dtq ➢{, IX"h�P .ct 4 a t (k'}QekKl k'41°t1417Fy��$�'#"i'3t �.P 4'{`°q A ET 1 1r k t}ik� ✓Z 5"kl Yy'*i 1�" P' sr 2t fB w .'i1, .� °,"',, '. t+.tr; �,kr '3".:;Y � �.N'-.a rye, ssR 'rF r•';+;5 � T��',:��''. lcr�;� r«r�:,, u C n�j��R 1�$1 Sr 1�� 1 �.,� Il. : �� ! "C 1 [°: tc11;3�. Builder: ALPHA DESIGN CONTRACT(BbMnQ.tnity: Lot: NA Address: 619 BERGER RD City: Fort Pierce State: FL Zip: 4 3 Passrngar',SUli�s »aus�,�meeteithe�;the,Per%rrnance„P�scnptrve;`or�F�l'Method� �� � <s ��A11?w?,ice@a�(fit�earteSt�i��Slt�tS ix,� 4� ���;; Lt 1;S`'^:r 'Y;a'tu,J+'rkt'r',t.,F. ?�.;f�"F hk. MlF�,cu»Y M.t� ",.3$Kv,lk T K �'Y�'.,5i..tti�. u:14r ;4t'^(Erf'>..di'� '.i �'4 f`F'l t'' $4.., R;q' �i„+i-• ,t'F r..:vn, a;d .-`b,,aY „ �� �'�"�PRE��RIPTIVE ME1�Hdi� T`he b�uildmg or d`elhn� and stall be tested and venfred as havm� an�a9rtleakag5;rate�of not e�ce�edmg Tair ����changes`perh�ur at a, pressure: ot'`4t2 ►nch"W.� (50 �akc�i(s) irl Cflmalt� �vttes�t a�nk� 2 �',� ' �� � �'��� ,� , e"� L � Q } �� ' �, S §+�' .[v 14 - }•. e;W 5! `� - N�5 t 1 d ` � rc. �JJ y� 5(, 9 t f f"'M" RA - '- 4 PEI±;FORMANCE oYR''er' c6METHD TJkCeetdm� 4 the seleeied ACtj(50)`Value, as shown on Four i R405 20 .,gPertor ante) orb# 406 20!47 (ERt), section labeled as in# ltration„Sub. section A�HSU z: s 4 y ` t(50) spec�fiec ork dorm R41J5 �Q97 Er/ergylc (Aen`ornaanee�or R406 2017 (IRl1j 5.000 Ja ih`)W L Y F b 4dA �:i f,(d _Ye}4 x 60 _ 32986 = Method for calculating building volume: CFM(50) Building Volume ACH(50) O Retrieved from architectural plans r—] PASS • Code software calculated When ACH(50) is less than 3, Mechanical Ventilation installation O Field measured and calculated must be verified by building department. R402.4.1.2 Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0;2 inch w.g. (50 Pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statues.or individuals licensed as set forth in Section 489.105(3)(f), (g), or (1) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to thecode official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other infiltration control measures. 2. Dampers including exhaust, intake, makeup air, back draft and flue dampers shall be closed, but not sealed beyond intended infiltration control measures. 3. Interior doors, if installed at the time of the test, shall be open. 4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5. Heating and cooling systems, if installed at the time of the test, shall be turned off. 6. Supply and return registers, if installed at the time of the test, shall be fully open. P s^: t ..- Sy,� p Company Name: Phone: I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: Date of Test: Printed Name of Tester: License/Certification #: Issuing Authority: 1/4/2019 7:56:22 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1