HomeMy WebLinkAboutEnergy Efficiency Code 1-2-19FORM R405-2017 FTLE COPY
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: 619 Berger Rd
Builder Name: ALPHA DESIGN CONTRACTOR LLC
Street: 619 BERGER RD
Permit Office: ST LUCIE COUNTY
City, State, Zip: Fort Pierce , FL ,
Permit Number:
Owner:
Jurisdiction: 6611000
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing
New (From Plans)
9. Wall Types (3085.0 sqft.)
Insulation Area
2. Single family or multiple family
Single-family
a. Concrete Block - Int Insul, Exterior
R=4.0 3085.00 ftz
b. N/A
R= ftz
3. Number of units, if multiple family
1
c. N/A
R= ftz
4. Number of Bedrooms
4
d. N/A
R= ftz
10. Ceiling Types (3436.0 sqft.)
Insulation Area
5. Is this a worst case?
No
a. Roof Deck (Unvented)
R=20.0 3436.00 ftz
6. Conditioned floor area above grade (ftz)
3436
b. N/A
R= ftz
Conditioned floor area below grade (ftz)
0
c. N/A
R= ftz
11. Ducts
R ftz
7. Windows(671.8 sqft.) Description
Area
a. Sup: Attic, Ret: Attic, AH: Main
6 687.2
a. U-Factor: Dbl, U=0.58
501.17 ftz
SHGC: SHGC=0.24
b. U-Factor: Dbl, U=0.58
170.67 ftz
12. Cooling systems
kBtEfficiency
SHGC: SHGC=0.17
a. Central Unit
69.1 .1 SEER:16.00
c. U-Factor: N/A
ftz
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A
ftz
a. Electric Strip Heat
60.0 COP:50.00
SHGC:
Area Weighted Average Overhang Depth:
6.597 ft.
Area Weighted Average SHGC:
0.222
14. Hot water systems
a. Electric
Cap: 40 gallons
8. Floor Types (3436.0 sqft.)
Insulation Area
EF: 0.980
a. Slab -On -Grade Edge Insulation
R=0.0 3436.00 ftz
b. Conservation features
b. N/A
R= fl2
None
c. N/A
R= ftz
15. Credits
CF, Pstat
Glass/Floor Area: 0.196
Total Proposed Modified Loads: 115.25
PASS
Total Baseline Loads: 115.37
1 hereby certify that the plans and specifications covered by
Review of the plans and
0Irt-RE Sr'4?�
this calculation are in compliance 'th th Florida Ener y
specifications covered by this
indicates
�r ; ;_ Off,
_,.•�';,o�`�
Code.
calculation compliance
yrc+ �r�,sJ,`
with the Florida Energy Code.
PREPARED BY:
DATE: 6
Before construction is completed
this building will be inspected for
compliance with Section 553.908
I hereby certify that this building, as designed, is c pliance
Florida Statutes.
with the Florida Energy Code.
(
Op WEB
OWNER/AGQ�T .�-'
f
BUILDING OFFICIAL:
DATE.
DATE:
- Compliance requires certification by the air handler unit manufacturer that -the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2).
1/4/2019 7:55 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title:
Building Type:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction:
Family Type:
New/Existing:
Comment:
619 Berger Rd Bedrooms: 4
User Conditioned Area: 3436
Total Stories: 1
1 Worst Case: No
ALPHA DESIGN CONTRACT Rotate Angle: 0
ST LUCIE COUNTY Cross Ventilation:
6611000 Whole House Fan:
Single-family
New (From Plans)
Address Type: Street Address
Lot #
Block/Subdivision:
PlatBook:
Street: 619 BERGER RD
County: St. Lucie
City, State, Zip: Fort Pierce ,
FL,
CLIMATE
V Design Location
Design Temp
TMY Site 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, Fort Pierce FL VERO_BEACH_MUNI 39 90
70
75 299 62 Low
BLOCKS
Number
Name
Area Volume
1
Blockl
3436 32985.6
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms InfilID Finished Cooled Heated
1
Main
3436 32985.6 Yes 6
4
1 Yes Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio
Main 306 ft 0
3436 ftz
---- 0 0. 1
ROOF
/
V #
Roof Gable Roof
Type Materials Area Area Color
Rad
Barr
Solar SA Emitt Emitt Deck Pitch
Absor. Tested Tested Insul. (deg)
1
Hip
Metal 3722 ftz 0 ft2 Unfinishe
N
0.35 No 0.4 No 20 22.6
ATTIC
V #
Type
Ventilation Vent Ratio (1 in)
Area
RBS IRCC
1
Full attic
Unvented 0 3436 ftz
N N
CEILING
#
Ceiling Type
Space R-Value Ins Type
Area Framing Frac Truss Type
1
Under Attic (Unvented)
Main 0 Blown
3436 ftz 0.11 Wood
1/4/2019 7:55 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent
Space
Cavity
EL-Vallie
Width
Ft In
Height
Et In
Area
Sheathing Framing
R-Vallla Erection
Solar
A
Below
1
W
Exterior
Concrete Block - Int Insul
Main
4
24
4
9 6
231.2 ft2
0
0.75
0
2
W
Exterior
Concrete Block - Int insul
Main
4
50
5
9 4
470.6 ft2
0
0.75
0
3
NW
Exterior
Concrete Block - Int Insul
Main
4
7
9 4
65.3 ft2
0
0.75
0
4
N
Exterior
Concrete Block - Int Insul
Main
4
18
4
9 6
174.2 ft2
0
0.75
0
5
N
Exterior
Concrete Block - Int Insul
Main
4
53
3
9 4
497.0 ft2
0
0.75
0
6
E
Exterior
Concrete Block - Int Insul
Main
4
13
4
9 4
124.4 ft2
0
0.75
0
7
E
Exterior
Concrete Block - Int Insul
Main
4
37
9 4
345.3 ft2
0
0.75
0
8
E
Exterior
Concrete Block - Int Insul
Main
4
17
4
9 4
161.8 ft2
0
0.75
0
9
NE
Exterior
Concrete Block - Int Insul
Main
4
4
5
9 4
41.2 ft2
0
0.75
0
10
SE
Exterior
Concrete Block - Int Insul
Main
4
4
5
9 4
41.2 ft2
0
0.75
0
11
S
Exterior
Concrete Block - Int Insul
Main
4
35
2
9 4
328.2 ft2
0
0.75
0
12
S
Exterior
Concrete Block - Int Insul
Main
4
40
8
9 4
379.6 ft2
0
0.75
0
13
E
Exterior
Concrete Block - Int Insul
Main
4
30
7 6
225.0 ft2
0
0.75
0
DOORS
#
Omt
Door Type
Space
Storms
U-Value
Width
Height
Area
Ft In
Ft In
1
N
Insulated
Main
None
.21
36
96
24 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
/
Wall
Overhang
V
#
Omt ID
Frame Panes
NFRC
U-Factor
SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1
W 1
Metal Low-E Double
Yes
0.58
0.24
Y
36.0 f12
2 ft 0 in
1 ft 0 in
None
None
2
W 2
Metal Low-E Double
Yes
0.58
0.24
Y
57.0 ft2
8 ft 0 in
1 ft 0 in
None
None
3
W 2
Metal Low-E Double
Yes
0.58
0.24
Y
31.7 ft2
8 ft 0 in
1 ft 0 in
None
None
4
W 2
Metal Low-E Double
Yes
0.58
0.17
Y
85.3 ft2
8 ft 0 in
1 ft 0 in
None
None
5
NW 3
Metal Low-E Double
Yes
0.58
0.24
Y
19.0 ft2
10 It 0 in
1 ft 0 in
None
None
6
N 4
Metal Low-E Double
Yes
0.58
0.17
Y
42.7 ft2
12 It 0 in
1 ft 0 in
None
None
7
W 2
Metal Low-E Double
Yes
0.58
0.24
Y
11.3 ft2
8 ft 0 in
1 ft 0 in
None
None
8
N 5
Metal Low-E Double
Yes
0.58
0.24
Y
22.5 ft2
2 ft 0 in
1 ft 0 in
None
None
9
N 5
Metal Low-E Double
Yes
0.58
0.24
Y
6.8 ft2
2 ft 0 in
1 ft 0 in
None
None
10
E 6
Metal Low-E Double
Yes
0.58
0.24
Y
11.3 ft2
2 It 0 in
1 ft 0 in
None
None
11
E 6
Metal Low-E Double
Yes
0.58
0.24
Y
36.0 ft2
2 It 0 in
1 ft 0 in
None
None
12
E 7
Metal Low-E Double
Yes
0.58
0.24
Y
95.0 ft2
10 ft 0 in
1 ft 0 in
None
None
13
E 8
Metal Low-E Double
Yes
0.58
0.24
Y
36.0 ft2
2 ft 0 in
1 ft 0 in
None
None
14
NE 9
Metal Low-E Double
Yes
0.58
0.24
Y
19.0 ft2
10 ft 0 in
1 ft 0 in
None
None
15
SE 10
Metal Low-E Double
Yes
0.58
0.24
Y
19.0 ft2
10 ft 0 in
1 ft 0 in
None
None
16
S 11
Metal Low-E Double
Yes
0.58
0.24
Y
6.8 ft2
2 ft 0 in
1 ft 0 in
None
None
17
E 8
Metal Low-E Double
Yes
0.58
0.24
Y
25.3 ft2
2 ft 0 in
1 ft 0 in
None
None
18
S 12
Metal Low-E Double
Yes
0.58
0.24
Y
13.0 ft2
8 ft 0 in
1 ft 0 in
None
None
19
S 12
Metal Low-E Double
Yes
0.58
0.17
Y
42.7 ft2
8 ft 0 in
1 ft 0 in
None
None
20
E 13
Metal Low-E Double
Yes
0.58
0.24
Y
45.0 ft2
2 ft 0 in
1 ft 0 in
None
None
21
E 13
Metal Low-E Double
Yes
0.58
0.24
Y
10.7 ft2
2 ft 0 in
1 ft 0 in
None
None
1/4/2019 7:55 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
INFILTRATION
# Scope
Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50)
.000305
2748.8 150.91 283.8 .1137 5
HEATING SYSTEM
#
System Type
Subtype
Efficiency Capacity
Block
Ducts
1 A
1 B
Electric Strip Heat/
Electric Strip Heatt
None
None
COP:50 34 kBtu/hr
COP:50 26 kBtu/hr
1
1
sys#1
sys#1
COOLING SYSTEM
#
System Type
Subtype
Efficiency Capacity Air Flow SHR
Block
Ducts
1 A
1 B
Central Unit/
Central Unit/
None
None
SEER: 16 41.5 kBtu/hr 1245 cfm 0.8
SEER: 16 27.6 kBtu/hr 828 cfm 0.8
1
1
sys#1
sys#1
HOT WATER SYSTEM
#
System Type SubType
Location
EF Cap Use SetPnt Conservation
1
Electric None
Main
0.98 40 gal 70 gal 120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Cert # Company Name
Collector Storage
System Model # Collector Model # Area Volume
FEF
None None
ft2
DUCTS
/
v #
— Supply —
Location R-Value Area
— Return— Air CFM 25 CFM25
Location Area Leakage Type Handler TOT OUT QN
RLF
HVAC #
Heat Cool
1
Attic 6 687.2 ft
Attic
171.8 ft Default Leakage Main (Default) (Default)
1 1
TEMPERATURES
Programable Thermostat: Y
CoolingJan Feb Mar
HeatinHJan HFeb Mar
Ventin Jan Feb X Mar
Ceiling Fans:
r may rj Jun�Xj Jul rl Au rl Se Oct
Oct
pr L May Jun Jul AuSep W
A r [ Ma Jun Jul Aug Se Oct
Nov
Nov
Nov
H
Dec
Dec
H Dec
1/4/2019 7:55 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
Thermostat Schedule: HERS 2006
Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
80
80
78
78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
80
80
78
78
78
78
78
78
78
78
Heating(WD)
AM
65
65
65
65
65
65
65
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
68
68
Heating (WEH)
AM
65
65
65
65
65
65
65
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
68
68
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Defauft(8 Ibs/sq.ft.
0 ft2
0 ft
0.3
Main
1/4/2019 7:55 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 5
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* =100
The lower the Energy Performance Index,
the more efficient the home.
1. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts R
6.0
c) AHU location
Main
3. No. of units (if multiple -family)
3.
1
4. Number of bedrooms
4.
4
13. Cooling system: Capacity
69.1
a) Split system SEER
5. Is this a worst case? (yes/no)
5.
No
b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6.
3436
d) Room unit/PTAC EER
e) Other
16.0
7. Windows, type and area
a) U-factor:(weighted average)
7a.
0.580
b) Solar Heat Gain Coefficient (SHGC)
7b.
0.222
14. Heating system: Capacity
60.0
c) Area
7c.
671.8
a) Split system heat pump HSPF
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
50.0
a) U-factor:(weighted average)
8a.
NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b.
NA
e) Gas furnace, LPG AFUE
f) Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a.
0.0
b) Wood, raised (R-value)
9b.
15. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF
0.98
b) Gas fired, natural gas EFL
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1.
e) Dedicated heat pump with tank EF
2. Masonry (Insulation R-value)
10A2.
4.0
0 Heat recovery unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
10131.
2. Masonry (Insulation R-value)
10132.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level
a) Ceiling fans
Yes
a) Under attic
11 a.
0.0
b) Cross ventilation
No
b) Single assembly
11 b.
c) Whole house fan
No
c) Knee walls/skylight walls
11c.
d) Multizone cooling credit
d) Radiant barrier installed
11 d.
No
e) Multizone heating credit
0 Programmable thermostat
Yes
`Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on ins�ed code compliant features.
Builder Signature: _ ' l Date:
U
Address of New Home: 619 BERGER RD City/FL Zip: Fort Pierce, FL
1/4/2019 7:56:04 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
Envelope Leakage Test Report (Blower Door Test)
Residential Prescriptive, Performance or ERI Method Compliance
2017 Florida Building Code, Energy Conservation, 6th Edition
Jurisdiction: 6611000
Permit #:
✓'i++prhivpy'#F '1}'FWkIS Dtq ➢{, IX"h�P .ct 4 a t (k'}QekKl k'41°t1417Fy��$�'#"i'3t �.P 4'{`°q A ET 1 1r k t}ik� ✓Z 5"kl Yy'*i 1�" P' sr 2t fB
w .'i1, .� °,"',, '. t+.tr; �,kr '3".:;Y � �.N'-.a rye, ssR 'rF r•';+;5 � T��',:��''. lcr�;� r«r�:,, u C n�j��R 1�$1 Sr 1�� 1 �.,� Il. : �� ! "C 1 [°: tc11;3�.
Builder: ALPHA DESIGN CONTRACT(BbMnQ.tnity: Lot: NA
Address: 619 BERGER RD
City: Fort Pierce State: FL Zip:
4 3
Passrngar',SUli�s »aus�,�meeteithe�;the,Per%rrnance„P�scnptrve;`or�F�l'Method� �� � <s
��A11?w?,ice@a�(fit�earteSt�i��Slt�tS ix,� 4� ���;;
Lt 1;S`'^:r 'Y;a'tu,J+'rkt'r',t.,F. ?�.;f�"F hk. MlF�,cu»Y M.t� ",.3$Kv,lk T K �'Y�'.,5i..tti�. u:14r ;4t'^(Erf'>..di'� '.i �'4 f`F'l t'' $4.., R;q' �i„+i-• ,t'F r..:vn,
a;d .-`b,,aY „
�� �'�"�PRE��RIPTIVE ME1�Hdi� T`he b�uildmg or d`elhn� and stall be tested and venfred as havm� an�a9rtleakag5;rate�of not e�ce�edmg Tair
����changes`perh�ur at a, pressure: ot'`4t2 ►nch"W.� (50 �akc�i(s) irl Cflmalt� �vttes�t a�nk� 2 �',� ' �� � �'��� ,� , e"� L � Q } �� ' �,
S §+�' .[v 14 - }•. e;W 5! `� - N�5 t 1 d ` � rc. �JJ y� 5(, 9 t f f"'M" RA - '- 4
PEI±;FORMANCE oYR''er' c6METHD TJkCeetdm�
4 the seleeied ACtj(50)`Value, as shown on Four i R405 20 .,gPertor ante) orb# 406 20!47 (ERt), section labeled as in# ltration„Sub. section A�HSU z:
s 4 y `
t(50) spec�fiec ork dorm R41J5 �Q97 Er/ergylc (Aen`ornaanee�or R406 2017 (IRl1j 5.000
Ja ih`)W L Y F b 4dA �:i
f,(d _Ye}4
x 60 _ 32986 = Method for calculating building volume:
CFM(50) Building Volume ACH(50)
O Retrieved from architectural plans
r—] PASS • Code software calculated
When ACH(50) is less than 3, Mechanical Ventilation installation O Field measured and calculated
must be verified by building department.
R402.4.1.2 Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0;2 inch w.g. (50 Pascals).
Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statues.or individuals licensed as set forth in Section
489.105(3)(f), (g), or (1) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and
provided to thecode official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope.
During testing:
1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other infiltration
control measures.
2. Dampers including exhaust, intake, makeup air, back draft and flue dampers shall be closed, but not sealed beyond intended infiltration control
measures.
3. Interior doors, if installed at the time of the test, shall be open.
4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed.
5. Heating and cooling systems, if installed at the time of the test, shall be turned off.
6. Supply and return registers, if installed at the time of the test, shall be fully open.
P s^:
t ..-
Sy,� p
Company Name: Phone:
I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code
Energy Conservation requirements according to the compliance method selected above.
Signature of Tester: Date of Test:
Printed Name of Tester:
License/Certification #: Issuing Authority:
1/4/2019 7:56:22 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1