HomeMy WebLinkAboutfinal inspectionp 4"° STATE OF FLORIDA
DEPARTMENT OF HEALTH
ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM
sttti CONSTRUCTION INSPECTION AND FINAL APPROVAL
`•) WE'R''
APPLICANT: Danielle King
AGENT: Laventure & Associates
PROPERTY ADDRESS: 6600 Peacock Rd Port Saint Lucie, FL 34987
APPLICATION #:AP' 51097.t,7
PERMIT #:56-SF-2092766
DOCUMENT # : F 11788534
DATE PAID : 06/19/2020
FEE PAID:660.00
RECEIPT #:56-PID-4459889
LOT:
BLOCK:
SUBDIVISION:
ID# : 3213-421-0001-000-3
CHECKED [X] ITEMS ARE NOT IN COMPLIANCE WITH STATUTE OR
RULE AND MUST BE CORRECTED.
TANK INSTALLATION
SETBACKS
[ ] (01]
TANK SIZE [11 1537.00 [2] [ ]
[271
SURFACE WATER FT
[ ] [02]
TANK MATERIAL Polypropylene [ ]
[28]
DITCHES FT
[ ] (031
OUTLET DEVICE [ ]
[291
PRIVATE WELLS 100 FT
[ ] [04]
MULTI -CHAMBERED [ Y N ] [ ]
(301
PUBLIC WELLS FT
[ ] [05]
OUTLET FILTER Polylok PL-68 [ ]
[311
IRRIGATION WELLS FT
[ ] [06]
LEGEND 1. 70-143-16DC4 2. [ ]
[32]
POTABLE WATER 100 FT
[ ] [07]
WATERTIGHT [ ]
[331
BUILDING FOUNDATIONS 9 FT
[ ] [08]
LEVEL [ ]
[34]
PROPERTY LINES 100 FT
[ ] [091
DEPTH TO LID [ ]
[351
OTHER FT
DRAINFIELD INSTALLATION
FILLED
/ MOUND SYSTEM
[ ] [101
AREA [11 588.64 [21 SQFT [ ]
[36]
DRAINFIELD COVER
[ ] [11]
DISTRIBUTION BOX HEADER X [ ]
[37]
SHOULDERS
[ ] [121
NUMBER OF DRAINLINES 1. 6.00 2. [ ]
[38]
SLOPES
[ ] (131
DRAINLINE SEPARATION [ ]
[39]
STABILIZATION 02/22/2022
[ ] (141
DRAINLINE SLOPE
[ ] [151
DEPTH OF COVER
ADDITIONAL
INFORMATION
[ ] [161
ELEVATION [ ABOVE / BELOW ]BM 4,00 [ ]
[401
UNOBSTRUCTED AREA
[ ] [171
SYSTEM LOCATION [ ]
[411
STORMWATER RUNOFF
[ ] [161
DOSING PUMPS [ ]
[421
ALARMS
[ ] [19]
AGGREGATE SIZE [ ]
[431
MAINTENANCE AGREEMENT
[ ] [20]
AGGREGATE EXCESSIVE FINES [ ]
[44]
BUILDING AREA
[ ] [211
AGGREGATE DEPTH [ ]
(451
LOCATION CONFORMS WITH SITE PLAN
[ ]
[46]
FINAL SITE GRADING
FILL
/ EXCAVATION MATERIAL
[ ]
[47]
CONTRACTOR Mike Spears (All County Sep
[ ] [221
FILL AMOUNT
[ ]
[48]
OTHER INFILTRATOR Quic1<4 Plus EQ36 LP
[ ] [231
FILL TEXTURE
[ ] [241
EXCAVATION DEPTH
ABANDONMENT
[ ] [251
AREA REPLACED [ ]
[49]
TANK PUMPED
[ ] [26]
REPLACEMENT MATERIAL [ ]
(501
TANK CRUSHED & FILLED
Comments: Comments
are on page 2.
/
St. Lucie CHD DATE: 10/28/2021
CONSTRUCTION
[ APPROVED
DISAPPROVED ] ' Environmental Specialist 11114tian J Ingram (ENVIRONMENTAL HEALTH)
FINAL SYSTEM
[ APPROVED / DISAPPROVED ]
St. Lucie CHD DATE: 02/22/2022
Envi onmental Specialist I Matt
S V '
i (Florida Department of H
(Explanation of
Violations on following page)
DH 4016, 08/09
(Obsoletes all previous editions which may not
be used)
Incorporated:
64E-6.003, FAC
Page 2 of 3
EH Database v 1.0.1 AP1510975
EID2092766
STATE OF FLORIDA
DEPARTMENT OF HEALTH
ONSITE SEWAGE TREATMENT AND
CONSTRUCTION INSPECTION AND
Violation Number Comment
Comments
DISPOSAL SYSTEM
FINAL APPROVAL
APPLICATION #:AP1510975
PERMIT #:56-SF-2092766
DOCUMENT # : FI 1788534
DATE PAID : 06/19/2020
FEE PAID:660.00
RECEIPT #:56-PID-4459889
The system is sized for 5 bedrooms with a maximum occupancy of 10 persons (2 per bedroom), for a total estimated flow of
460 gpd.
New ST, filter, and 4x9+2x8 long TRENCH DF installed. No violations, system ok to cover, contractor notified onsite. Needs final
inspection for mound system and final site grading.
Final inspection conducted. Mound system and depth of cover checked, final site grading completed. Violations observed. Foot of
drainfield requires more sodding.
Final inspection completed. Sod has been added to foot of drainfield.
Final inspection approved. Emailed copy to building department and contractor.
DH 4016, 08/09 (Obsoletes all previous editions which may not be used)
Incorporated: 64E-6.003, FAC Page 2 of 3
EH Database v 1.0.1 AP1510975 EID2092766