Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL ASPHALT SHINGLES Florida Building Code Online Page 1 of 2 ProfessionalBusiness & Regulation _ BC15 Home Log 1n User Registration i Hat Topics Submit Surcharge ! Stats 8,Facts Publications Contact Us 6CIS Site Hap LlakS Search db' Product Approval r 011 USER!Public User Product Approval Menu>Product or Application 5earch>Application List>Applieatlon Detail FL# FL30310-RI Application Type Revision Code Version 2020 Application Status Approved Comments Archived Product Manufacturer IKO Industries Ltd Address/Phone/Email 40 Hansen Road South Brampton,NON-US L6W 3114 (905)457-2880 Ext 4581 william.liu@ikc.com Authorized Signature William Liu william.liu@iko.com Technical Representative William Liu Address/Phone/Email 40 Hansen Road SotSth Brampton,FL L6W 3H4 (416)525-3740 william,liu@iko.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Asphalt Shingles Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Zachary R. Priest the Evaluation Report Florida License PE-74021 Quality Assurance Entity PRI Construction Materials Technologies, LLC Quality Assurance Contract Expiration Date 12/31/2024 Validated By Steven M.Urich, PE Validation Checklist-Hardcopy Received Certificate of Independence FL30310 R1 COI 1K019002.2 2020 FBC Eval Shingles flnal_.pdf Referenced Standard and Year(of Standard) Standard Yea.r ASTM D 3018 1990 ASTM D 3151 2016 ASTM d 3462 2010 ASTM E 108 2016 TAS 100 1995 TAS 107 2020 Equivalence of Product Standards Certified By https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgvH%2bffZf p... 1/11/2021 Florida Building Code Online Page 2 of 2 Sections from the Code Product Approval Method Method 1 Option D Date Submitted 10/16/2019 Date Validated 10/73/2020 Date Pending FBC Approval 10/28/2020 Date Approved 12/16/2020 Summary of Products FL# Model,Number or Name Description 30310.1 IKO Shingles ASTM D 3€61,Class F asphalt shingles, hip and ridge shingles,starter strip&shingle strip Limits of Use Installation Instructions Approved for use in HVMZ:Yes FL30310 R1 11 IK019002.2 2020 FBC Eval Shingles Approved for use outside HVHZ:Yes fznal.pdf Impact Resistant: N/A Verified By: Zachary R. Priest PF-74021 Design Pressure:N/A Created by Independent Third Party:Yes Other:See evaluation report for limits of use. Evaluation Reports FL30310 R1 AE IK019002.2 2020 FBC Eval Shingles final.odf Created by Independent Third Party:Yes Back Next Contact ::2601 5f3 r Stone Road,Tallahassee FL 32399 Phone:859-487-1824 The State of Florida is an AA/EEO employer.Coovriaht 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public recordsrequest,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487,1395.*Pursuant to Section 455.275 (1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455r F.S.must provide the Department with an email address if they have one.The emails provided may he used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address, please provide the Department with an emai{address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please dick here. Product Approval Accepts: ® ® Mmm Credit Card Safe https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param�wGEVXQwtDgvH%2bffZfjp... 1/11/2021 Certificate of Authorization No. 29824 CREEK17520 Edinburgh Dr Tampa, FL 33647 TECHNICAL SERVICES, LLC (813)480-3421 EVALUATION REPORT FLORIDA BUILDING CODE,7T"EDITION(2020) Manufacturer: IKO INDUSTRIES, LTD Issued October22, 2020 40 Hansen Rd S Brampton, ON L6W 311-14 Canada (905)457-2880 www.iko.com Manufacturing Plants: Calgary, Alberta Hawkesbury, Ontario Hillsboro,TX Kankakee, IL Sumas,WA Sylacauga, AL Toronto, Ontario Wilmington, DE Quality Assurance: PRI Construction Materials Technologies(QUA9110) SCOPE Category: Roofing Subcategory: Asphalt Shingles Code Edition: Florida Building Code, 7`r' Edition (2020) including High-Velocity Hurricane Zones(HVHZ) Code Sections: 1504.1.1, 1507.2.5, 1507.2.7.1, 1523.5.1, 1523.&5.1 Properties: Physical properties,Wind Resistance,Wind Driven Rain REFERENCES Entity Report No. Standard Year FM Approvals(TST1867) 3035971 FM 4475 2010 FM Approvals(TST1867) 3040947 FM 4475 2010 ASTM E 108 2016 FM Approvals(TST1867) 3041689 FM 4475 2010 FM Approvals(TST1867) 3044376 FM 4475 2010 FM Approvals(TST1867) 3045254 FM 4475 2010 FM Approvals(TST1867) 3046191 FM 4475 2010 PRI Construction Materials Technologies(TST5878) IKO-050-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) IKO-051-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) IKO-053-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) IKO-067-C2-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) IKO-071-02-01 ASTM D 3462 2010A PRI Construction Materials Technologies(TST5878) IKO-072-02-02 TAS 100 1995 PRI Construction Materials Technologies(TST5878) IKO-076-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) IKO-077-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) iKO-088-02-01 TAS 100 1996 PRI Construction Matenals Technologies(TST5878) IKO-095-02-01 ASTM D 3462 2010A PRI Construction Materials Technologies(TST5878) IKO-096-02-01 ASTM D 3462 2010A PRI Construction Materials Technologies(TST5878) IKO-099-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) IKO-100-C2-01 TAS 107 2020 PRI Construction Materials Technologies(TST5878) I KO-1 14-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) I KO-1 15-02-01 ASTM D 3161 2016 PRI Construction Materials Technologies(TST5878) IKO-117-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) IKO-120-02-01 ASTM D 3462 2010A IK019002.2 FL30310-R2 Page 1 of 15 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEKIKO INDUSTRIES,LTD Asphalt Shingles TECHNICAL SERVICES, LLC Entity Report No. Standard Year PRI Construction Materials Technologies(TST5878) I KO-121-02-01 ASTM D 3462 2010A PRI Construction Materials Technologies(TST5878) IKO-123-02-01 ASTM D 3161 2016 PRI Construction Materials Technologies(TST5878) IK0-125-02-01 TAS 107 2020 ASTM D 3161 2016 PRI Construction Materials Technologies(TST5878) IKO-126-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) IKO-127-02-01 ASTM D 3462 2010A PRI Construction Materials Technologies(TST5878) IKO-128-02-01 TAS 107 2020 ASTM D 3161 2016 PRI Construction Materials Technologies(TST5878) IKO-129-02-01 ASTM D 3462 2010A PRI Construction Materials Technologies(TST5878) IKO-130-02-01 ASTM D 3161 2016 PRI Construction Materials Technologies(TST5878) IKO-131-02-01 TAS 107 2020 ASTM D 3161 2016 PRI Construction Materials Technologies(TST5878) IKO-140-02-01 ASTM D 3462 2010A PRI Construction Materials Technologies(TST5878) IKO-148-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) IKO-153-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) IKO-171-02-01 ASTM D 3462 2010A PRI Construction Materials Technologies(TST5878) IKO-171-02-02 TAS 107 2020 ASTM D 3161 2016 PRI Construction Materials Technologies(TST5878) IKO-171-02-03 TAS 100 1995 PRI Construction Materials Technologies(TST5878) IKO-198-02-01 ASTM D 3462 2010A PRI Construction Materials Technologies(TST5878) IKO-198-02-02 TAS 100 2020 PRI Construction Materials Technologies(TST5878) IKO-198-02-03 ASTM D 3161 206 PRI Construction Materials Technologies(TST5878) IKO-199-02-01 ASTM D 3462 2010A PRI Construction Materials Technologies(TST5878) IKO-199-02-02 TAS 100 1995 PRI Construction Materials Technologies(TST5878) IKO-199-02-03 ASTM D 3161 2016 PRI Construction Materials Technologies(TST5878) IKO-201-02-01 ASTM D 3462 2010A ASTM E 108 2016 ASTM D 3018 1990(R94)EI PRI Construction Materials Technologies(TST5878) IKO-201-02-02 ASTM D 3161 2016 PRI Construction Materials Technologies(TST5878) IKO-201-02-07 TAS 100 1995 PRI Construction Materials Technologies(TST5878) IKO-202-02-01 ASTM D 3462 2010A ASTM E 108 2011 ASTM D 3018 1990(R94)E1 PRI Construction Materials Technologies(TST5878) IKO-202-02-02 TAS 107 2020 ASTM D 3161 2016 PRI Construction Materials Technologies(TST5878) IKO-202-02-07 TAS 100 1995 PRI Construction Materials Technologies(TST5878) IKO-203-02-01 ASTM D 3462 2010A ASTM E 108 2011 ASTM D 3018 1990(R94)E1 PRI Construction Materials Technologies(TST5878) IKO-203-02-02 ASTM D 3161 2016 PRI Construction Materials Technologies(TST5878) IKO-203-02-07 TAS 100 1995 PRI Construction Materials Technologies(TST5878) {KO-205-02-01 ASTM D 3462 2010A ASTM E 108 2016 ASTM D 3018 1990(R94)E1 PRI Construction Materials Technologies(TST5878) IKO-205-02-02 ASTM D 3161 2016 PRI Construction Materials Technologies(TST5878) IKO-205-02-07 TAS 100 1995 PRI Construction Materials Technologies(TST5878) IKO-206-02-01 ASTM D 3462 201CA ASTM E 108 2016 ASTM D 3018 1990(R94)EI PRI Construction Materials Technologies(TST5878) IKO-206-02-02 ASTM D 3161 2016 PRI Construction Materials Technologies(TST5878) IKO-206-02-07 TAS 100 1995 PRI Construction Materials Technologies(TST5878) IKO-208-02-01 ASTM D 3462 2010A PRI Construction Materials Technologies(TST5878) IKO-217-02-01 ASTM D 3462 2010A PRI Construction Materials Technologies(TST5878) IKO-218-02-01 TAS 100 1995 PRI Construction Materials Technologies(TST5878) 476CO017.1 ASTM D 3462 2010A PRI Construction Materials Technologies(TST5878) 476C0017.2 ASTM D 3161 2016 PRI Construction Materials Technologies(TST5878) 476C0017.3 ASTM E 108 2016 PRI Construction Materials Technologies(TST5878) 476C0020.1 ASTM D 3462 2010A PRI Construction Materials Technologies(TST5878) 476C0020.2 ASTM D 3161 2016 IK019002.2 FL30310-R2 Page 2 of 15 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK IKC I AsphalRI LTD Asphalt Shingles TECHNICAL SERVICES, LLC Enti Report No. Standard Year PRI Construction Materials Technologies(TST5878) 476C0020.3 ASTM F 108 2016 PRI Construction Materials Technologies(TST5878) 476C0033.1 ASTM D 3462 2010A PRI Construction Materials Technologies(TST5878) 476C0033.2 ASTM D 3161 2016 PRI Construction Materials Technologies(TST5878) 476C0033.3 ASTM E 108 2016 PRI Construction Materials Technologies(TST5878) 476T0002 ASTM 0 3462 2010A PRI Construction Materials Technologies(TST5878) 476T0003 TAS 100 1995 PRI Construction Materials Technologies(TST5878) 476T0004 ASTM D 3161 2016 PRI Construction Materials Technologies(TST5878) 476T0012 ASTM D 3462 2010A ASTM D 3018 1990(R94)E1 PRI Construction Materials Technologies(TST5878) 476T0013 ASTM D 3161 2016 TAS107 2020 PRI Construction Materials Technologies(TST5878) 476T0021 ASTM D 3462 2010A ASTM D 3018 1990(R94)E1 PRI Construction Materials Technologies(TST5878) 476T0022 ASTM D 3161 2016 TAS 107 2020 PRI Construction Materials Technologies(TST5878) 476T0023 ASTM E 108 2016 PRI Construction Materials Technologies(TST5878) 476T0034 ASTM D 3462 2010A PRI Construction Materials Technologies(TST5878) 476T0039 ASTM D 3462 2010A ASTM D 3018 1990(R94)E1 PRI Construction Materials Technologies(TST5878) 476T0040 ASTM D 3161 2016 PRI Construction Materials Technologies(TST5878) 476T0041 TAS 100 1995 PRI Construction Materials Technologies(TST5878) 476T0042 ASTM D 3462 2010A ASTM D 3018 11990(R94)E1 PRI Construction Materials Technologies(TST5878) 476T0043 TAS 100 1995 PRI Construction Materials Technologies(TST5878) 476T0044 ASTM D 3462 2010A ASTM D 3019 1990(R94)Ei PRI Construction Materials Technologies(TST5878) 476T0045 ASTM D 3161 2016 PRI Construction Materials Technologies(TST5878) 476T0046 TAS 100 1995 PRI Construction Materials Technologies(TST5878) 476TC057 ASTM D 3462 2010A PRI Construction Materials Technologies(TST5878) 47BT0058 ASTM E 108 2016 PRI Construction Materials Technologies(TST5878) 476T0059 ASTM D 3161 2015 PRI Construction Materials Technologies(TST5878) 476T0061 ASTM D 7158 2019ael PRODUCT DESCRIPTION RoofshakeTm HW 13-314" x 40-718", ASTM D 3161, Class F self-sealing, fiberglass reinforced, laminated (Sumas) architectural asphalt shingle surfaced with granules complying with ASTM D 3462. Shingles shall be used in the non-HVHZ only. ArmourshakeT"^ 18-112' x 37-318°, ASTM ❑ 3161, Class F self-sealing, fiberglass reinforced, laminated (Sumas) architectural asphalt shingle surfaced with granules complying with ASTM D 3462. Royal Estate'T" 13-114" x 40", ASTM D 3161, Class F self-sealing, fiberglass reinforced, laminated (Toronto) architectural asphalt shingle surfaced with granules complying with ASTM D 3462. Crowne Slate 13-114" x 39-112", ASTM D 3161, Class F self-sealing, fiberglass reinforced, laminated (Toronto) architectural asphalt shingle surfaced with granules complying with ASTM D 3462. Shingles shall be used in the non-HVHZ only. Dynasty7#° 13-314" x 40-718", ASTM D 3161, Class F self-sealing, fiberglass reinforced, laminated (Calgary, Hawkesbury, architectural asphalt shingle surfaced with granules complying with ASTM D 3462. Hillsboro, Kankakee& Shingles manufactured in Calgary and Sumas shall be used in the non-HVHZ only. Sumas) NordiCTM 13-314" x 40-718", ASTM D 3161, Class F self-sealing, fiberglass reinforced, laminated (Hillsboro&Kankakee) architectural asphalt shingle surfaced with granules complying with ASTM D 3462. IK019002.2 FL30310-R2 Page 3 of 15 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration forwhich this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK 1K0INDUSTRIES,LTD Asphalt Shingles TECHNICAL SERVICES, L..LC CambridgeTm 13-314" x 40-7/8", ASTM D 3161, Class F self-sealing, fiberglass reinforced, laminated (Calgary, Hawkesbury, architectural asphalt shingle surfaced with granules complying with ASTM D 3462. Hillsboro, Kankakee, Shingles manufactured in Calgary and Toronto shall be used in the non-HVHZ only. Sumas,Sylacauga, Toronto&Wilmington) CRC Biltmore® 13-314" x 40-718", ASTM D 3161, Class F self-sealing, fiberglass reinforced, laminated (Calgary, Hawkesbury, architectural asphalt shingle surfaced with granules complying with ASTM D 3462. Sumas& Toronto) Shingles manufactured in Calgary and Toronto shall be used in the non-HVHZ only. CRC Regency® 13-314" x 40-718", ASTM D 3161, Class F self-sealing, fiberglass reinforced, laminated (Calgary&Hawkesbury) architectural asphalt shingle surfaced with granules complying with ASTM D 3462. Shingles manufactured in Calgary shall be used in the non-HVHZ only. CRC Superglass® 13-1/4" x 39-318", ASTM D 3161, Class F self-sealing, 3-tab asphalt shingle with (Calgary, Hawkesbury& fiberglass mat coated on both sides with asphalt and surfaced with granules complying Toronto) with ASTM D 3462. Shingles manufactured in Calgary and Toronto shall be used in the non-HVHZ only. Marathon' Plus AR 13-114" x 39-318", ASTM D 3161, Class F self-sealing, 3-tab asphalt shingle with (Calgary,Hawkesbury, fiberglass mat coated on both sides with asphalt and surfaced with granules complying Hillsboro, Kankakee, with ASTM D 3462. Shingles manufactured in Calgary, Sumas and Toronto shall be Sumas,Sylacauga& used in the non-HVHZ only. Toronto) Hip&RidgeT11 12 13-114" x 36", ASTM D 3161, Class F fiberglass reinforced, monolayer asphalt hip and (Kankakee&Sylacauga) ridge shingle surfaced with granules and perforated every 12-inches complying with ASTM D 3462. Hip&Ridge PlusTM 13-114: x 39-318", ASTM D 3161, Class F fiberglass reinforced, monolayer asphalt hip (Calgary) and ridge shingle surfaced with granules and perforated every 13-inches complying with ASTM D 3462. Shingles shall be used in the non-HVHZ only. Hip and Ridge TM 13-114" x 39-318", ASTM D 3161, Class F fiberglass reinforced, monolayer asphalt hip (Sumas) and ridge shingle surfaced with granules and perforated every 10-inches complying with ASTM D 3462. Shingles shall be used in the non-HVHZ only. Armour Starter TM 13-114" x 39-318", ASTM D 3161, Class F fiberglass reinforced asphalt strip embedded (Sumas) with granules complying with ASTM D 3462. For use with ArmourshakeTM shingles. Leading Edge PIusTM 7-718" x 40-718°, ASTM f7 3161, Class F fiberglass reinforced, monalayer asphalt (Hawkesbury) shingle strip surfaced with granules complying with ASTM D 3462. I1<O19002.2 FL30310-R2 Page 4 of 15 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. KO INDUSTRIES, LTD CREEK Asphalt Shingles I TECHNICAL SERVICES, LLC INSTALLATION --------------------------------- —-------------------- Roofshalke Tm HW I Basic Wind S jyu!�): Max. 194.mp _Petq ................... (Sumas) Basic Wind Speed(Vad): i Max. 150 ................ ........--------- ---—----------------------- DeCk(HVHZ)' n accordance with FBC requirements, I Solidly sheathed min. 19/32 in. plywood or wood plank for new construction-, Min. 15/32 in. plywood existing construction. ...................... ............... Solidly sheathed in accordance with FBC requirements. .............­­..................................... .........._............................................................... Underlayment I In accordance with FBC requirements. ..................................... Min.slope: 2:12 and in accordance with FBC requirements. Refer to I the manufacturer's application instructions when installing shijqgjes at slopes greater than 21:12. --------------------------------- --------- ........... Installation on-HVHZ): Installed with 5-7/8 inch exposure, in accordance with FBC requirements and manufacturer's published installation instructions. Shingles shall be attached using "4 Nall Pattern"detailed below. -------------- ...................... ------------------------- Nall Line Common Bond Standard Application Requires 4 Nails 7/8 /— — — — — — — — — — — — — — Nail Line 5-7/8 Figure 1. RoofshakeTm HW 4 Nail Pattern (Non-HVHZ only) IK019002.2 FL30310-R2 Page 5 of 15 This evaluation report is provided for State of Florida product approval under Rule 61G20-3, The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. IKOI LTDCREEK Asphalt Shingles TEcHNICAL SE:RVICIES, LIL.,C --._.......... ............... - - ---- -- ------ _ - --------- -_ ---- _ ------------- ArmourshakeTm Basic Wind Speed Wind Naaisr}e_ Max 194_.__mpphh _ _ _---- _ .....-.___ -........-(Sumas) Max 15q mSpeed b ----------------------- ---_......-------............ Deck(HVHZ): In accordance with FBC requirements- Solidly sheathed min. 19/32 in. plywood or wood plank for new construction; Min. 15/32 in. plywood existing construction. Deck Non-HVHZ : Salidl sheathed in accordance with FBC requirements. - Y -- --------.-.__. ----- _.__._..., Underlayment In accordance with FBG requirements, _ ; Min. slope: 12:12 and in accordance with FBC requirements. Refer to the manufacturer's application instructions when installing shingles at slopes greater than 21:12. - - - --....- .-._._.__.. Installation(HVHZ): Installed with 5-7/8 inch exposure in accordance with RAS 115 and manufacturer's published installation instructions. Shingles shall be attached using "6 Nail Pattern" detailed below. _._._...._-- __W..._-............................_ -..1..._ ... - Installation (Non-HVHZ): Installed with 5-7/8 inch exposure in accordance with FBC requirements and manufacturer's published installation instructions. Shingles shall be attached using either"5 Nail Pattern"or T Nail Pattern"detailed below. Standard Application Requires 5 Nails/Fasteners Nail Line Alignment Notches Figure 2. Armourshake- ____.___._. .- 5 Nail Pattern (Non-HVHZ only}-�� Nailing—Steep Slopes/High Wind Areas Applications Requires 6 Nails/Fasteners Nail Line Alignment F Alignment Notches Notches Figure 3. ArmourshakeTm 6 Nail Pattern --------------- IK019002.2 FL30310-R2 Page 6 of 15 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEKIKO INDUSTRIES,LTD +� Asphalt Shingles TECHNICAL SERVICES,LLC -- ------......, __----- __.-.-.-...._._.- .............. Royal Esta#e'TM Basi__ c Wlnd Speed Mit) µ Max. 194 mph --- - --------------- - --------- ---------- (Toronto) Basic Wind Seed ' _.. ............ .P. . _NaS--) - Max. 153 mph Deck(HVHZ): I In accordance with FBC requirements- Solidly sheathed min. 19/32 in. plywood or wood plank for new construction- Min. 15/32 in. plywood existing construction. Deck Non-HVHZ�_ Solidly sheathed In accordance with FBC requirements. ....................... . --------- ...... Underlarrlent: In accordance with FBC requirements,.-.-._-.-.. - ._.. -.-.-.-._- I...... ....4 ------ .............._-..._,......_....-_.-........_....; Min. slope: 2:12 and in accordance with FBC requirements. Refer to the manufacturer's application instructions when installing shingles at slopes greater than 21:12. ------------ -- - g - -------._._.....................- - _._..-.._-.. Installation(HVHZ): Installed with 5-7/8 in. exposure in accordance with RAS 115 and manufacturer's published installation instructions. Shingles shall be attached using "S Nail Pattern" detailed _................... ----- _below. ---.-.-.-...-.-._---------------........ Installation (Non-HVHZ): Installed with 5-7/8 in. exposure in accordance with FBC requirements and manufacturer's published installation instructions. Shingles shall be attached using either'A Nail Pattern"or"6 Nail Pattern"detailed below. Standard Application Requires 4 Nails/Fasteners - - --- - y--- -- - - - - ---- -- -- -- - i Nails Figure 4. Royal EstateTM 4 Nail Patterny(non_HVHZ only) Steep Slope/High Wind Applications Requires 6 Nails/Fasteners Nails Figure 5. Royal EstateTM 6 Nail Pattern I1<019002.2 FL30310-R2 Page 7 of 15 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. INDUSTRIES,LTD CREEK IKO Asphalt Shingles I TECHNICAL,SERVICES,LLC ........................ ........------------ ------------------------------------1-1--..-..-.......--.-.--..-.-....-.......-.-.-.-.---—---------------------------------- .......... Crowne Slate Basic Wind S eed(V,,It): 1 Max. 194 ------------ (Toronto) Basic Wind Speed(V.w): Max. 160 mph .......... —-------------- Deck(HVHZ): In accordance with FBC requirements; Solidly sheathed min. 19/32 in. plywood or wood plank for new construction; Min. 15132 in. plywood existing I construction. Deck(Non-HV ........ Solidly sheathed in accordance with FBG requirements. ............................. Underlavment: In accordance with FBC requirements, ............... ---------------------------- Min. slope. 2:12 and in accordance with FBC requirements. Refer to the manufacturer's application instructions when installing shingles at slopes greater than 21:12. ----------------- ......... Installation (Non-HVHZ): Installed with 5-718 inch exposure, in accordance' with FBC requirements and manufacturer's published installation instructions. Shingles shall be attached using `5 Nail Pattern"detailed below................................... ........... ........... ........... Nail Line%-.. 101, EXPOSURE Standard Application Pecluires 5 Nails/Fasteners Nail Line Figure 6, Crown Slate 5 Nail Pattern (Non-HVHZ only)_................ --------------------------------------- IK019002.2 FL30310-R2 Page 8 of 15 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK IKO INDUSTRIES, LTD Asphalt Shingles TECHNICAL SERVICES, LLC dynastyT"' Basic Wlnd Speed(V,,r} Max 194 mph (Calgary(Nan-HVHZ), Basic Wind Speed (Vag Max 150 mph _ --- ---- ---- ._.__ Hawkesbury, Kankakee& Deck(HVHZ): In accordance with FBC requirements-, Sumas(Non-HVHZ)) Solidly sheathed min. 19/32 in. plywood or wood plank for new construction- Min. 15/32 in. plywood existing and construction. Deck(Non-HVHZ)_ Solidly sheathed in accordance with FBC requirements_ _ Nordic"' lJnderlayment In accordance with FBC requirements ----- _- (Kankakee) : Min. slope; 2:12 and in accordance with FBC requirements. Refer to the manufacturer's application instructions when installing and shingles at slopes greater than 21:12. . --- ----- _._._ .---._._._._. -. installation(HVHZ): Installed with 5-7/8 in. exposure in accordance with RAS CRC Regency® 115 and manufacturer's published installation instructions. Shingles shall be attached using "6 Nail Pattern" detailed below. i Installation (Non HVHZ) : Installed with 5-718 in. exposure in accordance with FBC requirements and manufacturer's published installation instructions. Shingles shall be attached using either'A Nail Pattern"or"6 Nail Pattern"detailed below. 1I Armourzwe ArmourZone Standard Application Requires 4 Nails/Fasteners Common Bond -- ------------ ------------ ----------- -- F ------------------------------ ArmourZone -'--------- ArmourZone r7 17 r7- Figure 7. DynastyTM and NordicTm 4 Nail Pattern (non-HVHZ on I►��- AmnawZone = 7 Steep Slope/High Wind Applications Requires 6 Nails/Fasteners i� Common Bond ----------- ----------- Z_ � •. i 14/4' ArmourZone r7 I Figure 8. DynastyTm and NordicT"' 6 Nail Pattern IKO19002.2 FL30310-R2 Page 9 of 15 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CR �[ IKO INDUSTRIES, LTD L.i l� Asphalt Shingles TECHNICAL.SERVICES, LLC ......................... w --.., CambridgeTM Bask Wind Speed Max 194 mph —--------------- ._._--------.............._.._._- _. (Calgary(Non-HVHZ), eed 150 Basic Wind S a� : Max. m. ----.... -- -_.p._. �!-.- -.... . Ph_ ----._. ----------..-... - -- -------- Hawkesbury, Hillsboro, Deck(HVHZ): In accordance with FBC requirements; Kankakee, Sumas, Solidly sheathed min. 19/32 in. plywood or wood plank for Sylacauga, Toronto(Non- ' new construction; Min. 15/32 in. plywood existing HVHZ)&Wilmington) construction. Deck(Non HVHZ) Solidly sheathed In accordance with FBC and requirements i� ..._ _ -__ _....�.......-- ----�--....._ Urtderlayment_ -- In accardanc with FBC requirements. ___._.-__._..__...-...-..-..-...-....___ Min. slope: 2:12 and in accordance with FBC requirements. Refer to CRC BiltmoreTM the manufacturer's application instructions when installing (Calgary(Nan-HVHZ), .-.--____--___.-.-..._-..____.-.-.-...._...___ _shingles at slopes greater than 21:12. - € Hawkesbury, Kankakee, _ - -- ................... . ..........._ .-.-._-...... Installation(HVHZ): Installed with 5-7/8 in. exposure in accordance with RAS Sumas(Nan-HVHZ) 8 115 and manufacturer's published installation instructions. Toronto(Non-HVHZ)) Shingles shall be attached using "6 Nail Pattern" detailed below. - ._.................. .-...-.....-_... ........-... __.........-.-....---.-.-..._..-._...-.... _-...... - -----...-.-..m_--..-..-.-.-.-. Installation (Non-HVHZ): Installed with 5-7/8 in. exposure in accordance with FBC requirements and manufacturer's published installation instructions. Shingles shall be attached using either'A Nail -------. : Pattern°'or"6 Nail Pattern"detailed below,- - - -----_.-.-.-.-.-.-_ Nail Line Common Bond Standard Application Requires 4 Nails/Fasteners 7/$' - - - - - - - - - ; - - - - = Nail �\ Line ' Figure 9, CambridgeTm and CRC Biltmore7ll 4 Nail Pattern (non-HVHZ only) ---.........-._ _ --....... - Nail Line Common Bond Steep Slope/High Wind Applications Requires 6 Nails/Fasteners 7/8 u ��- - - - - - - - - - - Nail Line 5-7/8 Figure 10. CambridgeT"' and CRC BiltmoreTM 6 Nail Pattern iK019002.2 FL30310-R2 Page 10 of 15 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK IKO INDUSTRIES. LTD Asphalt Shingles TECHNICAL SERVICES,LLC ..-..._..-....... - - -_---------------.-.-.---- ----_ ..-.-..,., --............ -- --..... ..... CRC SuperglassY" Basic Wind Speed(M it); i Max 194 mph -- - ------------------------------------ (Calgary , (Non-HVHZ), Basic Wind Speed(Vard) Max 154 mph - Hawkesbury, &Toronto ; Deck(HVHZ): In accordance with FBC requirements; (Non-HVHZ)) _ Solidly sheathed min. 19/32 in. plywood or wood plank for new construction; Min. 15/32 in. plywood existing and construction. .-.-.-. _ _____-_. Deck(Non HVHZ: Solidly sheathed in accordance with FBC requirements.- MarathonTM Plus AR __.. Underlayment In accordance with FBC requirements Non-HVHZ --- �.-..._ _ .-- -.............. ....-.- ......_, (Calgary( ) Min. slope: 2:12 and in accordance with FBC requirements. Refer to I Hawkesbury, Hillsboro, the manufacturer's application instructions when installing Kankakee, Sumas Non- ) Sylacauga Installation HVHZ: _ _shin--es_at_s-opes greater than 21:12. . HVHZ, S lacau a& - � -.�_ .............. .......- _............. Toronto(Non-HVHZ)) ( ) ` Installed with 5-718 in. exposure in accordance with RAS 115 and manufacturer's published installation instructions. Shingles shall be attached using T Nail Pattern" detailed and below. -------..-..-... ------ _._.-__--.-.----------------.-..._— ----.-.-...... ..........._-_-... ..... installation (Non-HVHZ): Installed with 5-7/8 in. exposure in accordance with FBC MarathonT°" requirements and manufacturer's published installation (Hillsboro&Sylacauga) instructions. Shingles shall be attached using either"4 Nail Pattern'or T Nail Pattern"detailed below. —_.......... - -----.------------........------ ..-.._. -__-...............__-....-.-.-.-.-.__, Standard Application Requires 4 Nails/Fasteners Sealant Strip Figure 11. CRC SuperglassT"', MarathonTm Plus AR and MarathonT1" 4 Nail Pattern (non-HVHZ only) Steep Slope/High Wind Applications Requires 6 Nails/Fasteners Sealant Strip Figure 12. CRC SuperglaSSTM, Marathon"" Plus AR and MarathonT�' B Nail Pattern IKO19002.2 FL30310-R2 Page I of'15 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK 1KO INDUSTRIES,LTD Asphalt Shingles TECHNICAL SERVICES, LL.0 ------------..-..---.-.-.---- . ----.-..............—.....---......-.,..,..,..-.-.-_.___..,..._ .-.....----- _ ..-.- _--------------- _W _- .._—__..-----.------------------------__-_, Hip&Ridge'TM 12 ;------------------- Basic Wind (Kankakee&Sylacauga) Basic Wind Speed_ (Va�)_ Max. 1.50 mph °Deck(HVHZ): ` In accordance with FBC requirements; Solidly sheathed and min- 19132 in. plywood or wood plank for new construction; i Min. 15132 in. povd existing construction. -----. Hip&Ridge PIUSTM Deck(Non-HVHZ)_ Solidly sheathed in accordance with FBC re-u-irements. Cal a ( g rY) Underlayment In ac-------------------only) --- ----------------- ----...... .... ( Y} Min slope: -e_ - v1-2.a.-n-d...in accordance With FBC requirements.: ........_ __.......---- -- ......-......... ._.-.. ; Installation: Installed with 5-518 inch exposure in accordance with the FBC and manufacturer's published installation instructions. The direction of the exposed end shall be away from the ------------------------------ prevailing wind. Perforation Marks tart Direction of prevailing wind e 0`' i i _ � I Nails � 54- 5�1 t I � r, I I" � •1 fll 4 I l I t� I 1"Taper Cut 6-1/4" Figure 13. Hip & RidgeT"^ 12 and - ___.-__ _._Hip &Ridge PLUS 11 (non HVHZ onLY._1_—......__ IKO19002.2 FL30310-R2 Page 12 of 15 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEKKd INDUSTRIES, LTD Asphalt Shingles TEcHPIICAL S1=RVICES,LLC Hip and RldgeTM Banc Wrnd S ed -- -- _..... -- Max. 194 mph ---- -- _ - Sumas ------------ - ----.-.------ ( ) : Basic Wind Speed(Vasa): -Max_15Q mPh Deck(Nan-HV> Z�: Solidly shgathed In accordance ......... _.... _ Underlayment In accordance with FBC requirements. - --Min - slope_ 2:12 and in accordance with FBC requirements -- ...------ .-- _ Installation: Installed with 5-518 inch exposure, in accordance with the FBC and manufacturer's published installation instructions. The direction of the exposed end shall be away from the ifinq wind. Nails tart Direction of prevailing wind r 1 qn — m i 1 1"Taper Cut I Perforation Marks V Optional Taper Cut I � I -._.-___._.-.--.---------._...............___ _____.-_Figure.14._ Hip RidgeT'" (non-HVHZ only) IKO19002.2 FL30310-R2 Page 13 of 15 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services,LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREAK IKO INDUSTRIES,LTD Asphalt Shingles TECHNICAL SERVICEs,LLC .................._...................... _.., -- ----._.._ -----_-_. _....._..__ Armour Starter rm i Basic Wind Speed(Vot): 1 Max. 194 (Somas) 1 Basic Wend Speed(Vasa_ : Max 150 mph _..----..._..........____._._...--------......_......-.-_ ___..._._._..._._ Deck(HVHZ): in accordance with FBC requirements-, Solidly sheathed min. 19132 in. plywood or wood plank for new construction; ......... Min. 15/32 in. plywood existing construction,._..__.-.-_.-._-__...__.._.___-- Deck(Non HVHZ) _ ry Solidly sheathed in accordance with FBC requirements. .-- _ Underlayment _ In accordance with FBC requirements. -------------- Min slope 2 12 and in accordance with FBC requirements.__- . ..-...- ----._..-. -- —-.-.-.-.-. _q.. - ----- i Installation. Installed in accordance with the FBC and manufacturers ? published installation instructions. Shall be attached with ----- -min_ V x 12 ga: roofing nails with min. 3/8-inch head. Standard Application Requires 4 Nails/Fasteners I Match Color STARTER COURSE to Selected 1" and 13" from Each End Armourshake Shingle Figure 15.Armour Starter"m .__-----------------.-_.___W.__._.__.-. Leading Edge Plus"m Basic Wind Speed_tVit)_: Max. 194 mph _ —� ----- _.__._.............. --i (Hawkesbury) Basic Wind Seed(Vasd�-_Max. 150 mph Deck(HVHZ): In accordance with FBC requirements; Solidly sheathed min. 19132 in. plywood or wood plank for new construction; ___ Min. 15/32 in. plywood existing construction. -----------------------------_ . ----------- - _ _------ -Deck ....._--- (Non-HVHZ): Solidly sheathed in accordance with FBC requirements. Underlayment.- In accordance with FBC requirements. _. _ ._....._.-_._ — .._..-.. - _Min slope_ _ _ _ 2:12 and in accordance with FBC requirements.-_ -- --._.-, W_.._.....- Installation: Installed in accordance with the FBC and manufacturer's € published installation instructions. Shall be attached with min_ 1'x 12 ga_roofin nails with min`318-inch head._ _ Standard Application Requires 4 Nails/Fasteners 4'from Each End 3 to 4"from Bottom i Figure 16. Leading Edge Plusl" IK019002.2 FL30310-R2 Page 14 of 15 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK IKOIs LTD Asphalt fialt Shingles 0 TECHNICAL SERVICES,LLC LIMITATIONS 1) Fire Classification is not within the scope of this evaluation. 2) The roof deck and the roof deck attachment shall be designed by others to meet the minimum design loads established for components and cladding and in accordance with FBC requirements. 3) The mean roof height shall be restricted to a maximum 33 ft in the HVHZ. 4) Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be checked for protrusion and corrected prior to underlayment application. 5) Shingles shall be installed starting at the eave in horizontal layers such that the laps shed water from the deck. 6) Installation of the evaluated products shall comply with this report, the FBC, and the manufacturer's published application instructions. Where discrepancies exist between these sources, the more restrictive and code compliant detail shall prevail. 7) All products listed in this report shall be manufactured under a quality assurance program sn compliance with Rule 61 G20-3. COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code, 7t" Edition (2020) including High-Velocity Hurricane Zones (HVHZ) as evidenced in the referenced documents submitted by the named manufacturer. ,,,,,,t4,E,Rrr,,,,, 2020.10.22 tiP`'•��G•E•NsF•�s��: 14:10:00 No 74021 h•,R. y, pWWMn ea Mi.. Tf * •* - -04'001 O:•• STATE OF : IJ Zachary R. Priest, P.E O R `O P•'•`=`� Florida Registration No. 74021 NAL�--� *+` Organization No.ANE11669 I I I I 1101 CERTIFICATION OF INDEPENDENCE CREEK Technical Services, LLC does not have, nor will it acquire,a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services, LLC is not owned,operated, or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R.Priest,P.E.does not have, nor will acquire,a financiai interest in any other entity involved in the approval process of the product. END OF REPORT 1K019002.2 FL30310-R2 Page 15 of 15 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or qualify assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein.