HomeMy WebLinkAboutFloor Plan 10-4-19, ."
18"-0"
— — — — — — — — — — — — — — — — — — — — —
�\ 16'-4" 1 7'-9"
----------------------------
i \
II \
I II \
I I \
, wo,
24'-4" 3,_5j" 4'-1(J"
1 '-7j"
-------4 — — — —
18'-4" 22'-0"
\ GUEST ROOM
R I I \ 22'-0"X12'-8"
® I II \ I
BACK PORCH 9' CLG.
\18'-4"X18'-C"
II
/
Q
3
R
9'— 0" 18,1.
—
49'-4"
25'-1"
5'-6" 1. 12'-2" .2'-2" 4'-
s\
44'-8"
AO\
a
R7=.eervEo
OCT 10 1%
Permitting Department ADVANCED
St. Lucie County
-5" 0('T-01�5?4DESIGN &
I I I I / 4'-8" 14'-0" z 18'-11" 1 -g 9'-101, ,-6" 10'-3" 1_6",
00
- P
I
N
1'-8" 17'-4"
19'-0"
0
N
WINDOW AND DOOR SCHEDULE
NO.
NOMINAL SIZE
TYPE
REMARKS
WIDTH X HT.
76"WIDE X 96" HIGH
=NTRY DOOR
OUT SWING, IMPACT PER PRODUCT APPRO'l�_
O2
64" WIDE X 96" HIGH
DOUBLE DOOR
PGT "SGD-780" SERIES
SLIDING GLASS DOOR
�3
30" WIDE X 96" HIGH
SINGLE DOOR
PGT "SGD-780" SERIES
SLIDING GLASS DOOR
®
36" WIDE X 72" HIGH
ALUM. SINGLE HUNG
IMPACT W CATEGORY it SAFETY
GLASS PER FBC 4 4410.2.3.1.3
U5
36" WIDE X 76" HIGH
ALUM. SINGLE HUNG
IMPACT W CATEGORY II SAFETY
GLASS PER FBC 4 4410.2.3.1.3
®
30" WIDE X 76" HIGH
ALUM SINGLE HUNG
IMPACT W CATEGORY II SAFETY
GLASS PER FBC 4 4410 2 3.13
O
27" WIDE X 36" HIGH
ALUM SINGLE HUNG
IMPACT WCATEGORY IISAFETY
GLASS PER FBC 4 4410,2.3.1,3
®
36" WIDE X 52" HIGH
ALUM, SINGLE HUNG
IMPACT W CATEGORY II SAFETY
GLASS PER FBC 4 4410.2,3,1,3
O
72" WIDE X 72" HIGH
ALUM. SINGLE HUNG
IMPACT W CATEGORY II SAFETY
GLASS PER FBC 4 4410.2.3,1.3
10
84" WIDE X 76" HIGH
ALUM SINGLE HUNG
IMPACT W CATEGORY II SAFETY
GLASS PER FBC 4 44102 3.1.3
11
24" WIDE X 76" HIGH
ALUM SINGLE HUNG
IMPACT W CATEGORY II SAFETY
GLASS PER FBC 4 4410.2.3.1.3
12
27" WIDE X 60" HIGH
ALUM. SINGLE HUNG
IMPACT W CATEGORY II SAFETY
GLASS PER FBC 4 4410.2.3.1.3
13
36" WIDE X 30" HIGH
ALUM. SINGLE HUNG
IMPACT W CATEGORY II SAFETY
GLASS PER FBC 4 4410.2.3.1.3
024"
0
WIDE X 32" HIGH
ALUM. SINGLE HUNG
IMPACT W CATEGORY it SAFETY
GLASS PER FBC 4 4410,211.3
CONTRACTOR TO VER FY ROUGH OPEN NG D HENS ONS FOR DOORS AND W NDOWS ORDERED PR OR TO CONSTRUCT ON
ALL DOORSANDWNDUNSTOBE LOWE GLASS AND NPACT
FLOOR PLAN
N mop. SCALE: 1/4" _ 1,-0"
t �m
101
U-
w
Of
0
N
N/— — — — — — — — — — — — — — — — — — — — — — — — — — — — — LjLj -----------------------`.—
C4
PORCH /
O
ITCH 24'-9"X6'-8'" R
25'-9"X9'-4" ' CLG j io
1 5 ` 9' CI G• / I
" L
/ / O 6 2 -81
Q I
BATH 12
0
MASTER BED ,0 12'—O"X12' 8"
18'-7j" X15'-64" 00 R
/24'-4" 1 18'-4" / \°_ /
PORCH I I ' \ /II
6'-0"X21'-4" ❑ KITCHEN N 1 II b \
® ❑ 24'-4"X22'-0" n I I \ /
i \
12, C G `V I \ FAMILY ROOM /
\ I I \ 18'-4"X18'-0" / ?Do
@+�b
16' CLG. / / Y
5'-5" \ \
o
Go
m
I ):)5'-On GO
R EXCERCISE ROOD
17'-0"X14'-0"
9' CLG, c
I
/ 17'-0"
2'-5" b'-9"L 4'-6"
11
\\
E.P. 1 // i \ R
1 \ / `
0 _9 -4 \ / 5'-53 -YY \ � i
- _ _
I W CLOSES/ TORAG
f—
T
P
5'-0"X4' "
I
— 7� T \ —
Ix I >a I
lr.
y o
I i y
l+a.
I\ \
I
NN
DINING ROOM
MEDIA ROOM
15'-8"x 10'-8"
\
12'-5"x 14'-10"
/
I 118'
I
ICLG� I
I
R
Nn
I
BATH
—
1��,
❑
I
\\
�
11 CLG.
I
08FYx
R
9'--4"
12 5
//
-*
7N,0n--
15-8
o+
8-3"
A/C
\\
o
D
I w CLOSET
I
\
3• m
\�4a . N
I
I
No
1
18'
CLG
I
\
I
I
11
1 YHT Ro I T
s A/e5'-ox102" II 16' C /o 2
I- — — — g,_,. I+np "� I i I \ 1T-10" M
� 3'-0"
I I ry
N�4
13 5 13�513 5 13 i�513 \ of I -CLOSET
4 x 4 -3 "
-- — -- 5 5 �{ -- — —� qqI b
,II I
j 37' 0"x 8'-5' I 2� 4 14 1 14 I II
° - C G.
4 Q ti
BED 4
12'30' x 13'-9"
NA
---- ---- I I CLG.
M
— 1,_6, — — — 14'-9" -6 7'-2" I'-69'-1"
2'-5° 3' " 4'-4" 3'-0" 3'-0" _6, 3'-1j" 3'-9j" 3'-92" 3'-1 ' 2,- " 3,_bN 2'-2" 4'-6" 4'-6" 2'-2"
18'-14" '7'--7" 11'-3A}" O
7 -5 7,
14'-10"
■M■
I
N
R.I
I
ARCHITECTS
T
GENERAL
CONTRACTORS
A ROUND HILL DEVELOPMENT GROUP COMPANY
17968 115 TH AVE. NORTH
JUPITER, FLORIDA 33478
PH: 561-216-1000
CELL 561-718-0831
319 167TH ST
NO. MIAMI BEACH, FL, 33162
305-454-8000
WWW,ADVANCED—DESIGN—BUILDING.COM
THESE DRAWINGS AND SPECIFICATIONS ARE
INSTRUMENTS OF SERVICE AND ARE THE PROPERTY OF
ROUND HILL DEVELOPMENT GROUP. INC./ dbR ADVANCED
DESIGN 4 BUILDING. THEY ARE NOT 70 BE USED ON
ANY OTHER PROJECTS OR EXTENSIONS OF THIS PROJECT
EXCEPT BY WRITTEN AGREEMENTS WITH ROUND HILL
DEVELOPMENT GROUP.
NO DESIGN CHANGES WHICH ALTER THE INTENT
OF THESE DRAWINGS OR SPECFlCAHONS ARE TO BE MADE
WITHOUT OBTAINING WRITTEN PERMISSION FROM
ROUND HILL DEVELOPMENT GROUP.
ArAHffwT: BERNARD
70NES
ARCMTE,CJ T
SEAL- r�,J
CLIENT:
BERGER ROAD
in
I
Go ADDRESS:
PLAN jw0"���
A�v
O
REVISIONS:
DRAWN BY. JMG
CHECKED BY: BVJ
PROJECT dl:
SCALE: j INCH
A-1
EXISTING LEGEND
FIRE
WALL MOUNT
SUPPRESSION
O' AT KITCHEN
HOOD
��
LING /�'T L\EENDANT LAMP(HEAT)
•NEW
EXISTING
EXISTING ADDED FIRE
PENRWT \ 1T°
SPRINKLER
SWITCH LETTER
HEAD HEAD
ORECESSED
ucHr
®
MAKE UP AIR
CEILING
RETURN AIR GRILLE
SURFACE
MOUNT
—
T X 4
FLUORESCENT
SUPPLY
5 g REGISTER
4..
i' II 2 X 4
uFLUORESCENT
CEILING FAN
EXIT SIGN/EMERGENCY
LIGHT COMBO
r:r EXHAUST FAN
EXIT
SIGN
{ 3 - WAY
$ SWITCH TS
SWITCH
PANEL
EMERGENCY LIGHTING
ll-�--
A-10\ CIRCUIT NO.
Q FIRE ALARM PULL STATION
GROUND TYPE DUPLEX RECEPTACLE
120V-20AMP INTEGRAL FAULT
INTERRUPT PROTECTION
GF"I
CD COMBINATION /VISIBLE
GROUND TYPE DUPLEX
STROBE
RECEPI'ACLE120V-20AMP
OpWEATHERPROOF TYPE
CD=CANDELA
CD=CANDELA
HO"-9e AFF PA71NG ETRNG
GROUND TYPE SINGLE
RECEPTACLE 12INGLE MP
GROUND
GROUND TYPE DUPLEX RECEPTACLE
- 20 E D
+187AFF UNLESS NOTED
MOUNTED IN CEILING
OTHERWISE
GROUND TYPE DUPLEX OUTLET
120V-204MP +18"AFT U.N.O.
L GROUND TYPE DOUBLE DUPLEX
RECEPTACLE 126V-20AMP MOUNTED
IN TWO GANG OUTLET BOX AT eAFF
UNLESS NOTED OTHERWISE
GROUND TYPE DUPLEX
12OV-20AMP MOUNT ABOVE
/-�30A 120V SPECIAL PURPOSE OUTLET
[/��/7II'\J (SUFFIX INDICATES AMPS)
COUNTER OR AT HEIGHT NOTED
� 220V
Oc
a COMMUNICATIONS OUTLET
�IA 3 WIRE yG OR 4 WIRE
SPECIAL PURPOSE 0
(SUFFIX INDICATES AMPS)
SATERPAD
SECURITY JUNCTION BOX
RADIO
N TV OUTLET 5Rn
O ANTENNA
SECURITY KEY PAD
CONDUIT
THRU WALL
SMOKE DETECTOR
0 (PHOTOFIECTRIC)
WIRELESS
TELEPHONE WAP ACCESS
OUTLET/OR POINT
Y CM CARBON MONOCIDE
PUBLIC DRESS INTERCOM
EMERGENCY
CALL/PUSH BUTTON
/^_ `
\ , / (CEILING MOUNT)
\�VJ � `'� SUFFIX INDICATES
(INTEGRATED TO SECURITY SYSTEM)
INPUT+OUTPUT
MICROPHONE OUTLET
�� (MICROPHONE SYSTEM)
PUBLIC ADDRESS/INTERCOM
5 SPEAKER (WALL MOUNT)
a -_SUFFIX INDICATES
' \ SUFFIX INDICATES
INPUT+OUTPUT
INPUT+OUTPUT
corn SECURITY CAMERA
❑■ SECURITY MOTION SENSOR
Lj THERMOSTAT
POS POINT OF SERVICE
SPEAKER WIRE POINT AT
®t OBT 10 BASE T WIRING
CEILING
SPEAKER VOLUMN
CONTROL
® RESTROOM A/C SUPPLY
® RESTROOM EXHAUST FAN
AIR DIFFUSER
SCALE: 1/4" = 1'—O"
ARCHITECTS
GENERAL
CONTRACTORS
A ROUND HILL DEVELOPMENT GROUP COMPANY
17968 115 TH AVE. NORTH
JUPITER, FLORIDA 33478
PH: 561-216-1000
CELL 561-718-0831
319 167TH ST
NO. MIAMI BEACH, FL, 33162
305-454-8000
WWW.ADVANCED-DESIGN-BU I LDING.COM
THESE DRAWINGS AND SPECIFICATIONS ARE
INSTRUMENTS OF SERVICE AND ARE THE PROPERTY OF
ROUND HILL DEVELOPMENT GROUP. INC./ dba ADVANCED
DESIGN R BUILDING. THEY ARE NOT t0 BE USED ON
ANY OTHER PROJECTS OR EXTENSIONS OF THIS PROJECT
EXCEPT BY WRITTEN AGREEMENTS WITH ROUND HILL
DEVELOPMENT GROUP.
NO DESIGN CHANGES WHICH ALTO THE INTENT
OF THESE ORAWINGS OR SPECFICATIONS ARE TO BE MADE
WITHOUT OBTAINING MUM PERMISSION FROM
ROUND HILL DEVELOPMENT GROUP.
ARCFN w.. BERNARD
JONES
ARCHITECT
'(�S
SEAL l
�T
DATE:
CLIENT:
11:11ielI :allo1m1bi
ADDRESS:
ELECTRICAL
REVISIONS:
DRAWN BY: JMG
CHECKED BY: BVJ
PROJECT it:
SCALE: I INCH
E I