Loading...
HomeMy WebLinkAboutLetter - Wind Load Pressurer• NRANFIELD CHITECTS 1683 N.E. 7EN�VN MACH RAID. 7EN5EN MACH, FLORIDA 3 0i= 7 PHONE; 772-203-6032 I X 172-253-560 1 May 30, 2017 Project information:, Islandia I 9550 S. Ocean Dr. Jensen Beach, FL Suite # 903 To whom it may concern: The following Wind Load Pressure Calculations have been performed at the aforementioned address utilizing the ASCE-7710 (Part 4- Buildings with height of 90-160 ft) Components and Cladding pressure formulas and were performed at the request of the Contractor — Natural, Flow. Building Information : Exposure D - Importance Factor #1 Height: 110 ft — 9"' Floor Wind Speed: 170 mph Minimum Required Opening Pressures: Openings that are 20 sgft to 50 : Zone 4 = +56.6 / -57.2 psf Zone 5 = +56.6 / -101.6 psf Openings that are 50 sgft to 100: Zone 4 - +52.4 / -54.8 psf Zone 5 = +52.4 / -91.8 psf Openings that are 100 sgft to 500:. Zone 4 = +48.8 / -52.4 psf Zone 5 = +48.8 / -84.1 psf If there are any comments or concerns please contact me. Sincerely, Stewart Granfield Granfield Architects PLLC stewart@granarch.comcastbiz.net 7-0-ti-E S ILIti br.bh— k-h—* L.6-y- I 9