Loading...
HomeMy WebLinkAboutRoofing Systems1/13/22, 828AM TGFU.R11436 - Roofing Systems I UL Product IQ UL Product !QTM TGFU.R11436 - Roofing Systems Note: We are enhancing our systems and you may notice duplicate entries/missing/outdated data. During this interim period, please contact our Customer Service at htrp-Y www.utcom/about�ocations. Roofing Systems SOPREI+hIA INC R11436 310 QUADRAL DR WADSWORTH, OH 44281-9571 United States Any roof covering system listed for use over a combustible roof deck can be installedover a non-combustible roof deck and achieve the same classification. Uniform thickness or tapered insulation may be used in the following systems provided they do not exceed the indicated incline or thickness. "Sopra-ISO" insulation may be used wherever polyisoryanurate insulation is specified. Unless otherwise indicated, "Sopra-ISO r'', "Sopra-ISO r Tapered", "Sopra-ISO+ r", "Sopra-ISO+ r Tapered", "Sopra-ISO F r", "Sopra-ISO F r Tapered", "Sopra-ISO H r", "Sopra-ISO H+ r", "Sopra-ISO Premier+ r", "Sopra=ISO FB r", "Sopra-ISO FB r Tapered", "Sopra-ISO B r", may be substituted for polyisoryanurate in any of the systems listed below. "Sopra-ISO r" or "Sopra-ISO r Tapered", may be perforated on one side for use as the contact side for BUR or modified bitumen membrane. "Sopra-ISO H r" may be used over any polyisoryanurate insulation product in any of the following Classifications. "Sopra-ISO FB r", "SopraASO FB r Tapered", may be substituted for "Sopra-ISO r". "Sopra-ISO+ r" may be substituted for "Sopra-ISO r" polyisoryanurate insulation in any of the following Classifications. "Sopra-ISO H s" or Atlas "ACFoam HS Cover Board" may be used over polyisoryanurate insulation product in any of the following Classifications. "Sopra-ISO H r" or Hunter "H-Shield HD" (minimum 1/2 in. thick) or "Sopra-ISO H+ r" or Hunter "HShield HD Composite CG" may be used over any UL Classified polyisoryanurate or polystyrene on non-combustible roof decks. Maximum incline shall be in accordance with the Classification established for the insulation/membrane roof covering system, but cannot exceed 2:12. Unless otherwise indicated, the insulation and barrier board adhesives designated "Duotack", "Duotack 365", "Duotack Neo" and "DUOTACK SPF" may be used to adhere insulation or barrier boards to the roof deck, to adhere insulation and barrier boards together or to adhere layers of insulation together, in any roof covering system Classification. "Sopra 4897" is an acceptable alternate to Type G1, Type G2 and "Sopra G" in all applicable Classifications. Unless otherwise specified, minimum insulation thickness shall be: 1. 1.0 in, for "Sopra-ISO Tapered x" 2. 1.3 in. for "Sopra-ISO + x" "Ultra -Max Plus" may be used in lieu of "Sopra-ISO + x" and "Tapered Ultra -Max Plus" may be used in lieu of " Sopra-ISO + Tapered x" National Gypsum Co, "DEXcell Glass Mat Roof Board" or "DEXcell FA Glass Mat Roof Board" may be used in any UL Classified roof covering system assembly that incorporates the use of minimum 1/4-in.-thick Georgia-Pacifc Gypsum LLC "DensDeck@ Roofboard" or "DensDeck Primee Roofboard" or "DensDeck DuraGuardl Roofboard" or United States Gypsum Co. SecuRocke Glass -Mat Roof Board. References to "SENTINEL P150 and "SENTINEL P200" include 50 mil and 60 mil product, unless otherwise noted. https:/riq.ulprospector.com/en/profile?e=148925 1/120 1/13/22, 8:28 AM TGFU.R11436 - Roofing Systems i UL Product iQ Georgia-Pacific Gypsum LLC "DensDeck Prime® STORMXwRoofboard" may be used as an alternate to Georgia-Pacifc Gypsum LLC "DensDeck Prime® Roofboard" in all applicable Classifications. 3/4 (20-mm) to 2-1/4 in. (60-mm) thick "Kingspan Optim RI Vacuum Insulation Panel (VIP)" adhered with any UL Classified insulation adhesive may be used under'a Barrier Board in all applicable Classifications when minimum 1/4-in. thick Georgia-Pacific Gypsum LLC "DensDeck Roofboard" or "DensDeck Prime® Roofboard" or "DensDeck Prime 21 Roofboard" or "DensDeck DuraGuard® Roofboard" or "DensDeck Prime® STORM)('"' Roofboard" or United States Gypsum Co. SECUROCKO Glass -Mat Roof Board (Type SGMRX)" or National Gypsum Co. "DEXcell Glass Mat Roof Board" or "DEXcell FA Glass Mat Roof Board" is used as a Barrier Board. DEfEC SYSTEMS LLC "TruGround'TM Conductive Primer", applied at 1/3 gal/100 ftZ may be used as an alternate to "Elastocol 500", "Elastocol 600c", "Elastocol Stick H2O", "Elastocol Stick WB Primer", "Alsan RS 222 Primer" and "Alsan RS 276 Primer" in all applicable Classifications. For Combustible Roof Decks - Class A: 1. A minimum 3-in. thick layer or a minimum two layers of 1.5-in. thick " 5opra-ISO+ r" or "Sopra-ISO H+ r" is placed directly over a combustible roof deck and is covered with any UL Classified roof covering membrane used in any UL Class A roof covering assembly to achieve a Class A fire Classification. As an alternative, any UL Classified insulation (except expanded or extruded polystyrene), any combination, any thickness, may used below the 3-in. minimum total thickness of "Sopra-ISO+ e' or "Sopra-IS0 H+ r". The insulation may be loosely laid or attached with fasteners and plates, hot roofing asphalt or cold adhesive. A vapor barrier (non-UL classified) may also be used below the insulation. All insulation joints must be staggered a minimum of 6-in. from the foof deck joints or from the insulation joints directly below. The maximum incline shall be in accordance with the Classification established for the membranefinsulation roof covering assembly, -,however the incline cannot exceed 1/2:12. 2. A minimum 1/2 in. thick layer of "Sopra-ISO H r" over a minimum 2.5-in. thick layer of any Soprema Inc Classified polyisocyanurate insulation is placed directly over a combustible roof deck and is covered with any UL Classified roof covering membrane'used in any UL Class A roofing assembly to achieve a Class A fire Classification. As an alternative, any UL Classified insulation (except expanded or extruded polystyrene), any combination, any thickness, may be used below the 3-in. minimum total thickness. The insulation may loosely laid or attached with fasteners and plates, hot roofing asphalt or cold adhesive. A vapor barrier (non-UL classified) may also be used below the insulation. All insulation joints must be staggered a minimum of 6-in. from the roof deck joints or from the insulation joints directly below. The maximum incline shall be in accordance with the Classification established for the membrane/insulation roof covering assembly; however the incline cannot exceed 1/2:12. 3. A minimum 1-in. thick layer of "5opra-ISO Premier+ r" is placed directly over a combustible roof deck and is covered with any UL Classified roof covering membrane used in any UL Class A roofing assembly to achieve a Class A fire Classification. As an alternative, any UL Classified insulation (except expanded or extruded polystyrene), any combination, any thickness, may be used below the 1-in. minimum thickness of "Sopra-ISO Premier+ r". The insulation may be loosely laid or attached with fasteners and plates, hot roofing asphalt or cold adhesive. A vapor barrier (non-UL classified) may also be used below the insulation. All insulation joints must be staggered a minimum of 6-in. from the roof deck joints or from the insulation joints directly below. The maximum incline shall be in accordance with the Classification established for the membranefinsulation roof covering assembly; however the incline cannot exceed 1/2:12. For Combustible Roof Decks - Class B: 1. A minimum 1.9-in. thick layer of "Sopra-ISO+ r" or "Sopra-ISO H+ r" is placed directly over a combustible deck and is covered with any UL Classified roofing membrane used in any UL Class B roofing assembly to achieve a Class B fire Classification. As an alternative, any UL Classified insulation (except expanded or extruded polystyrene), any combination, any thickness, may be used below the 1.9-in. minimum thickness layer of Soprema Inc "Sopra=ISO+ r" or "Sopra-ISO H+ r". The insulation may be loosely laid or attached with fasteners and plates, hot roofing asphalt or cold adhesive. A vapor barrier (non-UL classified) may also be used below the insulation. All insulation joints must be staggered a minimum of 6- in. from the roof deck joints or from the insulation joints directly below. The maximum incline shall be in accordance with the Classification established for the membrane/insulation roof covering'assembly, however the incline cannot exceed 1/2:12. 2. A minimum 1/2 in. thick layer of "Sopra-ISO H r" over a minimum of 1.4-in. thick layer of any Soprema Inc Classified polyisocyanurate insulation is placed directly over a combustible deck and is covered with any UL Classified roofing membrane used in any UL Class B roofing assembly to achieve a Class B fire Classification. As an alternative, any UL Classified insulation (except expanded or extruded polystyrene), any combination, any thickness, may be used below the 1.9-in. minimum thickness layer. The insulation may be loosely laid or attached with fasteners and plates, hot roofing asphalt or cold adhesive. A vapor barrier (non-UL classified) may also be used below the insulation. All insulation joints must be staggered a minimum of 6-in. from the deck joints or from the insulation joints directly below. The maximum incline shall be in accordance with the Classification established for the membrane/insulation roof covering assembly; however the incline cannot exceed 1/2:12. Unless otherwise indicated, when referring to gypsum board in the following classifications, the following will be referenced: United States Gypsum Co. "SECUROCK' Roof Board (Type FRX-G)" or "SECUROCK® Glass -Mat Roof Board (Type SGMRX)" or 1/2 or 5/8-in. thick "Type DCB", or minimum 1/4-in. thick Georgia-Pacifc Gypsum LLC "DensDeck® Roofboard" or "DensDeck Prime® Roofboard" or "DensDeck DuraGuardTM Roofboard" or "DensDeck Prime 2T"', Regular gypsum board (not Classified) laid with staggered joints (6-1n. offset) measuring 0.5-in. thick minimum and weighing 184-Ibs/100-ft.2 minimum or Georgia Pacific "Sound Deadening" Board, measuring 0.208-in. thick minimum and weighing 109-Ibs/100-ft2 minimum, mechanically fastened with all buttjoints staggered a minimum of 6-1n, from the insulation and plywood deck joints, hot mopped or adhered with any UL Classified insulation adhesive. hftps:/riq.ulprospector.com/en/proFile?e=148925 2/120 1/13/22, 8:28 AM TGFU.R11436 - Roofing Systems I UL Product iQ NOTE: Polystyrene insulation must be covered with minimum 1/4-in. thick Georgia-Pacific Gypsum LLC "DensDeck ® Roofboard" or "DensDeck Prime® Roofboard" or "DensDeck Prime 21 Roofboard" or "DensDeck DuraGuard® Roofboard" or Certainteed Gypsum Inc.. "GlasRoc" or United States Gypsum Co. SECUROCK® Glass -Mat Roof Board (Type SGMRX)" or National Gypsum Company "DEXcell Glas Mat Roof Board" or DEXcell FA Glas Mat Roof Board". Barrier Board (Optional): — "Sopraboard" (min 1/8 in.), perlite (min 1/2 in.), gypsum or gypsum fiber (min 1/4 in.) or wood fiberboard (min 1/2 in.) mechanically fastened, hot mopped or adhered with any UL Classified insulation adhesive. Base Sheet (Optional): — One or more plies Type G1 or Type G2; "Sopra IV", "Sopra VI", "Sopraglass 40", "Sopraglass 100", "Sopra G" or."Modified Sopra G", any combination mechanically fastened or adhered with hot asphalt. Ply Sheet (Optional): — One or more plies "Elastophene Sanded", "Elastophene HD", "Elastophene HR 2.2", "Elastophene HS FR", "Elastophene.HP", "Elastophene 180 Sanded", "Sopralene 180 Sanded 2.2", "Sopralene 180 Sanded", "Sopralene 250 Sanded", "Elastophene PS 2.2", "Elastophene 180 PS", "Sopralene 180.PS 2.2", "Sopralene 180 PS 3.0", "Sopralene 250 PS", "Elastophene HS", "Elastophene HS 62"or "Soprabase S" adhered with hot asphalt or mechanically fastened; or "Elastophene Flam "Elastophene Flam 2.2", "Elastophene Flam HD", "Elastophene Flam HR", "Elastophene Flam HS FR", "Elastophene Flam HP", "Sopralene Flam 180", "Sopralene Flam 250", "Elastophene Flam HS," "Elastophene Flam HS HD," "Colvent TG" or "Soprabase TG" heat welded or mechanically fastened; or "Soprafix", "Soprafix X" or "Soprafix E" mechanically fastened; or "ELASTOPHENE Stick", "ELASTOPHENE Flam Stick", "ELASTOPHENE SURE -STICK", "ELASTOPHENE ULTRA -STICK", "SOPRALENE ULTRA -STICK", "SOPRALENE Stick", "SOPRALENE Flam Stick", "SOPRALENE SURE -STICK", "Colvent SA" or "EPS Flam'Stick self -adhered; or "Soprasmart Board", "Soprasmart Board 180", "Soprasmart ISO ND", "Soprasmart ISO HD 180", "Soprasmart Board Sanded", "Soprasmart Board 180 Sanded", "Soprasmart ISO HD Sanded", or "Soprasmart ISO HD 180 Sanded" adhered with "Duotack" or "Duotack 365" adhesive or hot asphalt or mechanically fastened. Cap Sheet: — "Elastophene FR GR", "Elastophene HD FR GR", "Elastophene HR FR_ GR", "Elastophene HS FR GR", "Elastophene HP'FR GR", "Elastophene LS"FR GR", "Sopralene 180 FR GR", "Sopralene 180 FR GR 3.5" or "Sopralene 250 FR GR" adhered' with hot asphalt, or "Elastophene Flam FR GR", "Elastophene Flam HD FR GR", "Elastophene Flam HR FR GR", "Elastophene Flam HS FR GR", "Elastophene Flam HP FR GR", "Elastophene Flam LS FR GR", "Sopralene Flam 180 FR. GR", "Sopralene Flam 180 FR GR 3.5" or "Sopralene Flam 250 FR GR" heat welded; or "Colphene FR GR", "Elastophene Stick FR GR", "ELASTOPHENE SURE -STICK FR GR" or "ELASTOPHENE ULTRA -STICK FR GR", self -adhered: 89 Deck- N,C, Incliate: 1' Prirnner'(®pt"im_�a1� AQUAFIN "VAPORTIGHT COAT-SG3" ( t UL Classified), applied at 1 gal/100 ft2. Thermal Barrier (Optional): — Gypsum or gypsum fiber (min 1/4 in.), perlite or mineral wool (min 3/4 in.), cement board (min 1/4 in.) or wood fiberboard (min 1/2 in.) mechanically fastened or adhered with any UL Classified insulation adhesive. Vapor Retarder (Optional .: —Any UL Classified or Soprema base sheet, ply sheet or Sopravap'r, mechanically fastened or adhered. Base Sheet -(Optional):'— One or more plies Type G1 or Type G2; "Sopra IV", "Sopra VI", "Sopraglass 40", "Sopraglass 100", "Sopra G", "Modified Sopra G", or "SURESTICKI Nail Base", any combination mechanically fastened or adhered with hot asphalt. Ir_sul —on (Op¢i alj Polyisocyanurate, polystyrene (EPS, XPS), glass fiber, mineral wool, perlite, wood fiber or cellular glass insulation, any thic ness, any combination, mechanically fastened, loose laid or adhered with hot asphalt or insulation adhesive. NOTE: Polystyrene insulation must be covered with minimum 1/4-in. thick Georgia-Pacific Gypsum LLC "DensDeck ® Roofboard" or "DensDeck Prime® Roofboard" or "DensDeck Prime 2T Roofboard" or "DensDeck DuraGuard® Roofboard" or Certainteed Gypsum Inc. "GlasRoc" or United States Gypsum Co. SECUROCK® Glass -Mat Roof Board (type SGMR)Q". Barrier Board (Optional): — "Sopraboard" (min 1/8 in.), perlite (min 1/2 in.), gypsum or gypsum fiber (min 1/4 in.) or wood fibecboard .(min 1/2 in mechanically fastened, hot mopped or adhered with any UL Classified insulation adhesive. Base Sheep (Optional): One or more plies Type G1 or Type G2; "Sopra IV", "Sopra VI", "Sopraglass 40", "Sopraglass 100", "Sopra G" or "Modified Sopra G", an combination -mechanically fastened or adhered with hot asphalt. Ply Sheet (Optional) —,One Amore_ lies 'Elastophene Sanded", "Elastophene HD", "Elastophene HR 2.2", "Elastophene HS FR", "Elastophene HP", "Elastophene 180 Sanded", "Sopralene 180 Saode_.d 2.2", "Sopralene 180 Sanded", "Elastophene PS 2.2", "Elastophene 180 PS", "Sopralene 180 PS 2.2", 'ral 1ene 80�PS 34, "Sopralene 250 PS", "Elastophene HS", "Elastophene HS 62" or "Soprabase S";adhered with hotasphalt or mechanically` astef ned; or "Elastophene Flam", "Elastophene Flam 2.2", "Elastophene Flam HD", "Elastophene Flam HR", "Elastophene Flam HS FR", "Elastophene Flam HP", "Sopralene Flam 180", "Elastophene Flam HS", "Elastophene Flam HS HD% "Colvent TG" or "Soprabase TG" heat welded or mechanically fastened; or "Soprafix", "Soprafix X" or "Soprafix E" mechanically fastened; or "ELASTOPHENE Stick", "ELASTOPHENE Flam Stick", "ELASTOPHENE SURE -STICK", "ELASTOPHENE ULTRA -STICK", SOPRALENE ULTRA -STICK", "SOPRALENE Stick", "SOPRALENE Flam Stick", "SOPRALENE SURE -STICK", "Colvent SA" or "EPS Flam Stick self -adhered; or "Soprasmart Board", "Soprasmart Board 180", "Soprasmart ISO HD", "Soprasmart ISO HD 180", "Soprasmart Board Sanded", "Soprasmart Board 180 Sanded", "Soprasmart ISO HD Sanded", or "Soprasmart ISO HD 180 Sanded —"adhered with Duotack'_or "Duotack 365" adhesive or hot asphalt or mechanically fastened. {a Sheet: — 'Sopralene 180 FRG ", "Sopralene 180 FR GR 3.5" or "Sopralene 250 FR GR" adhered with hot asphalt, or "Sopralene 1c:a Flam 180 FR GR", "Sopralene Flam 180 FR GR 3.5" or "Sopralene Flam 250 FR GR" heat welded; or Unilay FR mechanically fastened. https://Iq.ulprospector.com/en/profile?e=148925 65/120