Certification for Design Load Compliance
Project Name:
Project Address: t,-)C7 i I-i r, {?�;r .
Permit #:
Occupancy Type: Construction Type:
INSTRUCTIONS FOR USE:
• This certification must be completed, signed, and sealed by the design professional of record.
• Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following:
o New Residences (single or multi -family)
o Residential Addition COP
o Any accessory structure requiring a building permi _
o Any non-residential structure.
* Note: Form not required for interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the local building official. Contact the # above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply)
1. DESIGN CODE: Florida Code Fifth Edition with 20_Supplements using ASCE 7-10
2. Structure Designed as (check one): unclosed Partially Enclosed Open
3. Risk Category: _I III IV Exposure Category: ✓� C D
4. Design Wind Velocity t b0 mph L04ASD �LRFD End Zone Width: L_ft
5. Mean Roof Height /_ �r., ft Roof Pitch: S :12 Parapet: P/jft
6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings):
4r-0,5- +17.5' + 17i5 430-K 430.91 4 Z(4-3
Zone 1:-zq. e Zone 2: - L10-1-t_ Zone 3: - ?I • ezz, Zone 4: - Y3.o Zone 5: • ID•'7 Garage: -2,2. S
7. Design Loads: Floor:140.0 LL PSF Roof/Dead: 1 S _PSF Roof/Live: Z0 Balcony: . &j/A�PSF
Dock: -)Jln PSF Deck: 101�1' PSF Stairs: PIP PSF Fence: P16�, PSF Railings: P /APSF
8. Were Shear Walls Considered For Structure? v-"�es Not Applicable . Explain Why Not:
La -Lit ,L U2 PO 1-�P4)5
9. Is A Continuous Load Path Provided? ✓Yes Not Applicable Explain Why Not:
I) I) I, r-r✓ I A ), L�_Jt7 I oA,,) l
10. Design Soil Bearing Pressure:rov PSF Soil Test Reports Submitted? NYes
DESIGN PROFESSIONAL CERTIFICATION STATEMENT:
I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to
comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie
County. I also certify that structural elements depicted on these plans provide adequate resistance to the design
forces specified:
-77 - Print Name Cert # & Co. Cert Auth.
(�'
Signature, Cafe, and Seal Cc.a I ` 3 2r1 ?6,
Company Name & Address
Revised 07/25/2014