Loading...
HomeMy WebLinkAboutCertificate For Design Load ComplianceRECEI'.' .D JUL 13 2017 Planning & Development Services Department Building & Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553 Certification for Design Load Compliance Project Name: Project Address: t,-)C7 i I-i r, {?�;r . Permit #: Occupancy Type: Construction Type: INSTRUCTIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) o Residential Addition COP o Any accessory structure requiring a building permi _ o Any non-residential structure. * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida Code Fifth Edition with 20_Supplements using ASCE 7-10 2. Structure Designed as (check one): unclosed Partially Enclosed Open 3. Risk Category: _I III IV Exposure Category: ✓� C D 4. Design Wind Velocity t b0 mph L04ASD �LRFD End Zone Width: L_ft 5. Mean Roof Height /_ �r., ft Roof Pitch: S :12 Parapet: P/jft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): 4r-0,5- +17.5' + 17i5 430-K 430.91 4 Z(4-3 Zone 1:-zq. e Zone 2: - L10-1-t_ Zone 3: - ?I • ezz, Zone 4: - Y3.o Zone 5: • ID•'7 Garage: -2,2. S 7. Design Loads: Floor:140.0 LL PSF Roof/Dead: 1 S _PSF Roof/Live: Z0 Balcony: . &j/A�PSF Dock: -)Jln PSF Deck: 101�1' PSF Stairs: PIP PSF Fence: P16�, PSF Railings: P /APSF 8. Were Shear Walls Considered For Structure? v-"�es Not Applicable . Explain Why Not: La -Lit ,L U2 PO 1-�P4)5 9. Is A Continuous Load Path Provided? ✓Yes Not Applicable Explain Why Not: I) I) I, r-r✓ I A ), L�_Jt7 I oA,,) l 10. Design Soil Bearing Pressure:rov PSF Soil Test Reports Submitted? NYes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also certify that structural elements depicted on these plans provide adequate resistance to the design forces specified: -77 - Print Name Cert # & Co. Cert Auth. (�' Signature, Cafe, and Seal Cc.a I ` 3 2r1 ?6, Company Name & Address Revised 07/25/2014