HomeMy WebLinkAboutFlood elevation - finalU.S. DEPARTMENT OF HOMELAND SECURITY OMB No. 1660-0008
Federal Emergency Management Agency Expiration Date: November 30, 2022
National Flood Insurance Program
ELEVATION CERTIFICATE
Important: Follow the instructions on pages 1-9.
Copy all pages of this Elevation Certificate and all attachments for (1) community official, (2) insurance agent/company, and (3) building owner.
SECTION A — PROPERTY INFORMATION
FOR INSURANCE COMPANY USE
Al. Building Owner's Name
Policy Number:
Kevin James Murphy
A2. Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and
Company NAIC Number:
Box No.
2422 Oak Drive
City State ZIP Code
Fort Pierce Florida 34949
A3. Property Description (Lot and Block Numbers, Tax Parcel Number, Legal Description, etc.)
Fort Piercce Shores Unit 1, Block 3, Lots 6 and 7
A4. Building Use (e.g., Residential, Non -Residential, Addition, Accessory, etc.) Residential
A5. Latitude/Longitude: Lat. 27°28'55.79999" Long. 80°17'57.98182" Horizontal Datum: ❑ NAD 1927 0 NAD 1983
A6. Attach at least 2 photographs of the building if the Certificate is being used to obtain flood insurance.
AT Building Diagram Number 1B
A8. For a building with a crawlspace or encosure(s):
a) Square footage of crawlspace or enclosure(s) N/A sq ft
b) Number of permanent flood openings in the crawlspace or enclosure(s) within 1.0 foot above adjacent grade N/A
c) Total net area of flood openings in A8.1b N/A sq in
d) Engineered flood openings? ❑x Yes ❑ No
A9. For a building with an attached garage:
a) Square footage of attached garage 542.00 sq ft
b) Number of permanent flood openings in the attached garage within 1.0 foot above adjacent grade 5
c) Total net area of flood openings in A9.b 1280.00 sq in
d) Engineered flood openings? ❑x Yes ❑ No
SECTION B — FLOOD INSURANCE RATE MAP (FIRM) INFORMATION
B1. NFIP Community Name & Community Number
B2. County Name
B3. State
120285
St Lucie
Florida
B4. Map/Panel
B5. Suffix
B6. FIRM Index
B7. FIRM Panel
B8. Flood
B9. Base Flood Elevation(s)
Number
Date
Effective/
Zone(s)
(Zone AO, use Base Flood Depth)
Revised Date
12111CO181
k
02-19-2020
02-19-2020
AE
4.0 Feet
1310. Indicate the source of the Base Flood Elevation (BFE) data or base flood depth entered in Item B9:
❑ FIS Profile ❑x FIRM ❑ Community Determined ❑ Other/Source:
B11. Indicate elevation datum used for BFE in Item B9: ❑ NGVD 1929 ❑x NAVD 1988 ❑ Other/Source:
B12. Is the building located in a Coastal Barrier Resources System (CBRS) area or Otherwise Protected Area (OPA)? ❑ Yes x❑ No
Designation Date: ❑ CBRS ❑ OPA
FEMA Form 086-0-33 (12/19) Replaces all previous editions. Form Pagel of 6
ELEVATION CERTIFICATE
OMB No. 1660-0008
Expiration Date: November 30, 2022
IMPORTANT: In these spaces, copy the corresponding information from Section A.
FOR INSURANCE COMPANY USE
Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No.
Policy Number:
2422 Oak Drive
City State ZIP Code
Company NAIC Number
Fort Pierce Florida 34949
SECTION C - BUILDING ELEVATION INFORMATION (SURVEY REQUIRED)
C1. Building elevations are based on: ❑ Construction Drawings' ❑ Building Under Construction' ❑x Finished Construction
'A new Elevation Certificate will be required when construction of the building is complete.
C2. Elevations - Zones Al-A30, AE, AH, A (with BFE), VE, V1-V30, V (with BFE), AR, AR/A, AR/AE, AR/A1-A30, AR/AH, AR/AO.
Complete Items C2.a-h below according to the building diagram specified in Item A7. In Puerto Rico only, enter meters.
Benchmark Utilized: FDNR '94-77-A-28" Vertical Datum: NAVD88
Indicate elevation datum used for the elevations in items a) through h) below.
❑ NGVD 1929 ❑x NAVD 1988 ❑ Other/Source:
Datum used for building elevations must be the same as that used for the BFE.
Check the measurement used.
a) Top of bottom floor (including basement, crawlspace, or enclosure floor) 4.5 feet ❑ meters
b) Top of the next higher floor 5.7 0 feet ❑ meters
c) Bottom of the lowest horizontal structural member (V Zones only) N/A ❑ feet ❑ meters
d) Attached garage (top of slab) 4.5 0 feet ❑ meters
e) Lowest elevation of machinery or equipment servicing the building feet meters x
6.1 ❑ ❑
(Describe type of equipment and location in Comments)
f) Lowest adjacent (finished) grade next to building (LAG) 3.8 ❑x feet ❑ meters
g) Highest adjacent (finished) grade next to building (HAG) 4.8 ❑x feet ❑ meters
h) Lowest adjacent grade at lowest elevation of deck or stairs, including ❑ feet ❑ meters
structural support N/A
SECTION D - SURVEYOR, ENGINEER, OR ARCHITECT CERTIFICATION
This certification is to be signed and sealed by a land surveyor, engineer, or architect authorized by law to certify elevation information.
I certify that the information on this Certificate represents my best efforts to interpret the data available. I understand that any false
statement may be punishable by fine orimprisonment under 18 U.S. Code, Section 1001.
Were latitude and longitude in Section A provided by a licensed land surveyor? ❑x Yes ❑ No ❑ Check here if attachments.
Certifiers Name License Number
Ted E. Phillips LS5932
Title
Professional Surveyor and Mapper
Company Name
TEPHILLIPS, LLC
Address
102 SW Parish Terrace
City State ZIP Code
Port St. Lucie Florida 34984
Signature Date Telephone Ext.
/ 11-04-2021 (772)359-7023
Copy all pages of this Elev Certificate and all attachments for (1) community official, (2) insurance agent/company, and (3) building owner.
Comments (includinglype of equipment and location, per C2(e), if applicable)
Flood Vents, are Smart Vent Products, Model Number 1540-521.
Latitude and Longitude calculated from Army Corps of Engineers "Corpscon" program.
Equipment is an Air Conditioning Condenser, and Water Pump.
FEMA Form 086-0-33 (12/19) Replaces all previous editions. Form Page 2 of 6
11
BUILDING PHOTOGRAPHS OMB No. 1660-0008
ELEVATION CERTIFICATE See Instructions for Item A6. Expiration Date: November 30, 2022
IMPORTANT: In these spaces, copy the corresponding information from Section A.
FOR INSURANCE COMPANY USE
Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No.
Policy Number:
2422 Oak Drive
City State ZIP Code
Company NAIC Number
Fort Pierce Florida 34949
If using the Elevation Certificate to obtain NFIP flood insurance, affix at least 2 building photographs below according to the
instructions for Item A6. Identify all photographs with date taken; "Front View" and 'Rear View"; and, if required, 'Right Side View" and
"Left Side View" When applicable, photographs must show the foundation with representative examples of the flood openings or
vents, as indicated in Section A8. If submitting more photographs than will fit on this page, use the Continuation Page.
f
Plato One
Photo One Caption Front / West side Clear Photo One
a
PMto Two
Photo Two Caption North Side Clear Photo Two
FEMA Form 086-0-33 (12/19) Replaces all previous editions. Form Page 5 of 6
BUILDING PHOTOGRAPHS OMB No. 1660-0008
ELEVATION CERTIFICATE Continuation Page Expiration Date: November 30, 2022
IMPORTANT: In these spaces, copy the corresponding information from Section A.
FOR INSURANCE COMPANY USE
Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No.
Policy Number:
2422 Oak Drive
City State ZIP Code
Company NAIC Number
Fort Pierce Florida 34949
If submitting more photographs than will fit on the preceding page, affix the additional photographs below. Identify all photographs
with: date taken; "Front View" and "Rear View"; and, if required, "Right Side View" and "Left Side View" When applicable,
photographs must show the foundation with representative examples of the flood openings or vents, as indicated in Section A8.
-
.rtJ k I ^y
Photo Thwm
Photo Three Caption South Side Clear Photo Three
Phdo Four
Photo Four Caption Rear / East Side Clear Photo Four
FEMA Form 086-0-33 (12/19) Replaces all previous editions. Form Page 6 of 6
Back_ta P'--,c- uta:cg
ww+ 9taiel�ss S1'r»I . .
Black
Insulated Flood Vent - Stacker
1540-521
Flood Coverage
400 sq.ft.
Air Ventilation
N/A
Vent Size
16"w x 16'h x 3"d
Rough Opening
` 16.25'w x 16.375'h
Available Colors
Gray Stainless Steel, White, Black, b,..y,
Wheat
Stacker Models are twice as efficient as a single unit, and ore a great
solution for large amounts of square footage requiring flood protection as
vial) as wh=,y there is not enough wall space to fit single units.
Application
it far garages or conditioned spaces where
are regwr ea, out air ventilation is not desired.
Flood Protection
The vent door is latched closed until it comes in contact wlti- "..-: y ..
Entering flood water!ifts the patented internal floats wh;c'
allow the door to rotate open. This allows the flood water
enter and exit through the frame opening, relieving the pressure fror, ,
foundation walls. Certified flood debris clearance is demonstrated wit'r, c. >
diometar opening wherthe flood door is activated.
Ventilation
The flood door contains a 2insulated core that has an R-volue of 8.
There is also a felt weather stripping that lines the entire vent frame
helping to keep the enclosure as insulated as possible.
Resources
CAU Filc
!C_C=ES Certifier„
F o ida pLoductt ApP,4yc i
Related Products
Flood Vent
SSaBna.Kit-
-
sta
Hurribond
Adhesive b
Caulk
Stacker Finish
Elgnse 6"- B.5"
Wall
nuts a,;.,: ,...
1114i21, 7:52 Aki
Cage 1 of 3
--�6 #- zolz-oy10
• 316L MARINE GRADE STAINLESS STEEL
• [CC -ES CERTIFIED I ESR-2074
• FLORIDA BUILDING PRODUCT APPROVED
• FEMA ACCEPTED
• 15 YEAR EXTENDED WARRANTY
• MADE IN THE U.S.A.
a�ef.
Y
0l 3