Loading...
HomeMy WebLinkAboutEnergy Efficiency CodeFORM R405-2014 t ,1 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department'of Business and Professional Regulation- Residential Performance Method Project Name: TAIG RESIDENCE Builder Name: AMERON HOMES Street: 6104 E SEMINOLE RD. Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Owner: K TAIG Jurisdiction: Design Location: FL, Fort Pierce County:: St. LUCIE COUNTY (Florida Climate Zone 2) 1. New construction or existing New (From Plans) 9. Wall Types (1304.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1064.00 ft2 b. Frame - Wood, Adjacent R=11.0 240.00 ft2 rF ' 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 10. Ceiling Types (1210.0 sqft.) Insulation Area 5. Is this a worst case? No a. Under Attic (Vented) R=48.0 1210.00 ft2 6. Conditioned floor area above grade (ft2) 1210 b. N/A R= ft2 c. N/A R= ft2 Conditioned floor area below grade (ft2) 0 11. Ducts R ft2 7. Windows(148.8 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 325 a. U-Factor: Dbl, U=0.45 148.80 ft2 SHGC: SHGC=0.25 b. U-Factor: N/A ft2 12. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 24.0 SEER:16.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Strip Heat 17.0 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 2.000 ft. Area Weighted Average SHGC: 0.250 14. Hot water systems a. Electric Cap: 40 gallons 8. Floor Types (1210.0 sqft.) Insulation Area EF: 0.950 a. Slab -On -Grade Edge Insulation R=0.0 1210.00 ft2 b. Conservation features b. N/A R= ft2 No c. N/A R= ft2 15. Cred' CF, Pstat Total Proposed Modified Loads: 43.96 �`"' "" C Glass/Floor Area: 0.123 P ►S �7�7 Total Baseline Loads: 45.66 I hereby certify that the plans and specifications covered by Review of the plans and O� tIlE S1Pq�� this calculation are in compliance with the Florida Energy specifications covered by this Off, Code. calculation indicates compliance y ,,,� '' .9 �O with the Florida Energy Code. rnr,�•-`;. ��,� PREPARED BY: - DATE: IL P - -- I Before construction is completed this building will be inspected for compliance with Section 553.908 0 _0{J� * ° I hereby certify that this uil ' as designed, is in compliance Florida Statutes. COD with the Florida Energy o e. WEE OWNER/AGENT: BUILDING OFFICIAL: DATE: - DATE: - Compliance requires certification by the air handier unit manufacturer that the air handier enclosure qualifies as certified factory -sealed in accordance with R403.2.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope -leakage test report in accordance with R402.4.1.2. 6/7/2017 2:26 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 FORM R405-2014 PROJECT Title: TAIG RESIDENCE Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1210 Lot # Owner: K TAIG Total Stories: 1 Block/SubDivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: AMERON HOMES Rotate Angle: 0 Street: 6104 E SEMINOLE RD. Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: ST. LUCIE COUNTY Jurisdiction: Whole House Fan: No City, State, Zip: FT. PIERCE, Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE v IECC Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site Zone 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 2 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1210 9680 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 BEDROOM 3 188 1504 No 1 1 1 Yes Yes Yes 2 BEDROOM 2 156 1248 No 1 1 1 Yes Yes Yes 3 BATH 2 40 320 No 0 1 Yes Yes Yes 4 KITCHEN 110 880 Yes 0 1 Yes Yes Yes 5 DINING 110 880 No 0 1 Yes Yes Yes 6 LIVING 296 2368 No 0 1 Yes Yes Yes 7 MASTERB EDROO 180 1440 No 2 1 1 Yes Yes Yes 8 WIC 49 392 No 0 1 Yes Yes Yes 9 M BATH 81 648 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio BEDROOM 3 27 ft 0 188 ft2 ---- 0 1 0 2 Slab -On -Grade Edge Insulatio BEDROOM 2 26 ft 0 156 ft2 ---- 0 1 0 3 Slab -On -Grade Edge Insulatio BATH 2 5 ft 0 40 ft2 ---- 0 1 0 4 Slab -On -Grade Edge Insulatio KITCHEN loft 0 110 ft2 ---- 0 1 0 5 Slab -On -Grade Edge Insulatio DINING loft 0 110 ft2 ---- 0 1 0 6 Slab -On -Grade Edge Insulatio LIVING 19 ft 0 296 ft2 ---- 0 1 0 7 Slab -On -Grade Edge Insulatio MASTERB EDRO 12 ft 0 180 ft2 ---- 0 1 0 6/7/2017 2:26 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 5 FORM R405-2014 FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 8 Slab -On -Grade Edge Insulatio WIC 15 ft 0 49 ft2 ---- 0 1 0 9 Slab -On -Grade Edge Insulatio M BATH 9 ft 0 81 ft2 ---- 0 1 0 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch 1/ # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Gable or Shed Composition shingles 1275 ft2 202 ft2 Medium 0.6 No 0.9 No 0 18.4 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 1210 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) BEDROOM 3 48 Blown 188 ft2 0.1 Wood 2 Under Attic (Vented) BEDROOM 2 48 Blown 156 ft2 0.1 Wood 3 Under Attic (Vented) BATH 2 48 Blown 40 ft2 0.1 Wood 4 Under Attic (Vented) KITCHEN 48 Blown 110 ft2 0.1 Wood 5 Under Attic (Vented) DINING 48 Blown 110 ft2 0.1 Wood 6 Under Attic (Vented) LIVING 48 Blown 296 ft2 0.1 Wood 7 Under Attic (Vented) MASTERB EDRO 48 Blown 180 ft2 0.1 Wood 8 Under Attic (Vented) WIC 48 Blown 49 ft2 0.1 Wood 9 Under Attic (Vented) M BATH 48 Blown 81 ft2 0.1 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below it Ornt Space 10 'Alai' TimeR-1/allie Et In Et In Area RA/allie Fraction Ahsor Grarie% 1 N Exterior Concrete Block - Ext In!8EDROOM 3 4.1 11 0 8 0 88.0 ft2 0 0 0.6 0 2 E Exterior Concrete Block - Ext InQEDROOM 3 4.1 16 0 8 0 128.0 ft2 0 0 0.6 0 3 N Exterior Concrete Block - Ext In!flffDROOM 2 4.1 14 0 8 0 112.0 ft2 0 0 0.6 0 4 W Exterior Concrete Block - Ext ImUDROOM 2 4.1 12 0 8 0 96.0 ft2 0 0 0.6 0 5 W Exterior Concrete Block - Ext Insul BATH 2 4.1 5 0 8 0 40.0 ft2 0 0 0.6 0 6 E Exterior Concrete Block - Ext InsuKITCHEN 4.1 10 0 8 0 80.0 ft2 0 0 0.6 0 7 E Exterior Concrete Block - Ext Insul DINING 4.1 10 0 8 0 80.0 ft2 0 0 0.6 0 8 W Exterior Concrete Block - Ext Insul LIVING 4.1 19 0 8 0 152.0 ft2 0 0 0.6 0 9 E Exterior Concrete Block - Ext In9MASTERB E 4.1 12 0 8 0 96.0 ft2 0 0 0.6 0 10 E Exterior Concrete Block - Ext Insul WIC 4.1 9 0 8 0 72.0 ft2 0 0 0.6 0 11 S Exterior Concrete Block - Ext Insul WIC 4.1 6 0 8 0 48.0 ft2 0 0 0.6 0 12 S Exterior Concrete Block - Ext InsulM BATH 4.1 9 0 8 0 72.0 ft2 0 0 0.6 0 13 N Garage Frame - Wood MASTERB E 11 30 8 240.0 ft2 0.23 0.6 0 6/7/2017 2:26 PM EnergyGauge@ USA - FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5 FORM R405-2014 DOORS # Ornt Door Type Space Storms U-Value Width Ft In Height Ft In Area 1 W Insulated LIVING None .39 3 6 8 20 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. V # Wall Ornt ID Frame Panes NFRC U-Factor SHGC Overhang Area Depth Separation Int Shade Screening 1 2 3 4 5 6 7 8 E 2 Vinyl N 3 Vinyl W 4 Vinyl E .6 Vinyl E 7 Vinyl W 8 Vinyl E 9 Vinyl S 12 Vinyl Low-E Double Yes Low-E Double Yes Low-E Double Yes Low-E Double Yes Low-E Double Yes Low-E Double Yes Low-E Double Yes Low-E Double Yes 0.45 0.25 0.45 0.25 0.45 0.25 0.45 0.25 0.45 0.25 0.45 0.25 0.45 0.25 0.45 0.25 15.0 ft2 2 ft 0 in 1 ft 4 in 15.0 ft2 2 ft 0 in 1 ft 4 in 15.0 ft2 2 ft 0 in 1 ft 4 in 9.0 ft2 2 ft 0 in 1 ft 4 in 40.8 ft2 2 ft 0 in 9 ft 0 in 30.0 ft2 2 ft 0 in 1 ft 4 in 20.0 ft2 2 ft 0 in 1 ft 4 in 4.0 ft2 2 ft 0 in 1 ft 4 in Drapes/blinds Drapes/blinds Drapes/blinds Drapes/blinds None Drapes/blinds Drapes/blinds Drapes/blinds Exterior 5 Exterior 5 Exterior 5 Exterior 5 None Exterior 5 Exterior 5 Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 462 ft2 384 ft2 32 ft 8 ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 1129.3 62 116.6 .2598 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat None COPA 17 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Split SEER: 16 24 kBtu/hr cfm 0.8 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 40 gal 60.9 gal 120 deg None 6/7/2017 2:26 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5 FORM R405-2014 SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ftz DUCTS V --- Supply ---- ---- Return ---- Air CFM 25 CFM25 HVAC # # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 325 ftZ Attic 85 ft2 Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: CoolingJan HeatinJan Feb f X Feb [ ] Mar [X] Mar f Apr Apr E Jul May 4 Jun Jul Ma X Jun rl AuSep rl Aug Se [ ]Oct [ ] Oct H Nov Nov [ ] Dec [X] Dec Ventin Jan [ Feb X Mar [X] A r [ Ma [ Jun Jul Aug Se �X] Oct Nov [ ] Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 6/7/2017 2:26 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 5 FORM R405-2014 TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: TAIG RESIDENCE Builder Name: AMERON HOMES Street: 6104 E SEMINOLE RD. Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Owner: K TAIG Jurisdiction: Design Location: FL, Fort Pierce COMPONENT CRITERIA CHECK Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. Breaks or joints in the air barrier shall be sealed. Air -permeable insulation shall not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Corners and headers shall be insulated and the junction of the foundation Walls and sill plate shall be sealed. 'The junction of the top plate and the top or exterior walls shall be sealed. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. Windows, skylights and doors The space between window/doorjambs and framing and skylights and framing shall be sealed. Rim joists Rim joists are insulated and include an air barrier. Floors (including above -garage Insulation shall be installed to maintain permanent contact with underside and cantilevered floors) of subfloor decking. The air barrier shall be installed at any exposed edge of insulation. Crawl space walls Where provided in lieu of floor insulation, insulation shall be permanently attached to the crawlspace walls. Exposed earth in unvented crawl spaces shall be covered with a Class I vapor retarder with overlapping joints taped. Shafts, penetrations Duct shafts, utility penetrations, and flue shaft openings to exterior or unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be airtight, IC rated, and sealed to the drywall. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air barrier installed separating them from the showers and tubs. Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or air sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have gasketed doors 6/7/2017 2:26 PM EnergyGaugeO USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1