FL FL16023
Application Type New
Code Version 2010
Application Status Approved
*Approved by DBPR. Approvals by DBPR shall be reviewed and ratified
by the POC and/or the Commission if necessary.
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Certification Agency
Validated By
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
MI Windows and Doors
650 West Market Street
Gratz, PA 0 4
(717) 365-330-3300 Ext2560
bsitlinger@miwd.com
Brent Sitlinger
bsitlinger@miwd.com
Windows
Single Hung
Certification Mark or Listing
American Architectural Manufacturers Association
Steven M. Urich, PE
Validation Checklist - Hardcopy Received
Standard
AAMA/WDMA/CSA 101/I.S. 2/A440
Method 1 Option A
10/23/2012
10/23/2012
11/05/2012
v. jaiF.,n
Year
2005
http://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGE'VXQwtDgtFPmdYiNDWr... 5/12/2017
�I - Florida Building Code Online
Page 2 of 3
Summary of Products
FL
Model, Number or Name
Description
16023.1
3500 HP SH
36x72 Finless Frame Insulating Glass
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +50/-60
Other: H-R50
Certification Agency Certificate
FL16023 RO C CAC APC B9170 01-109-47-RO 3500HP SH
FLS 3-4IG 1-8A 36X72 RS0-DP-60osf(0S0216)odf
Quality Assurance Contract Expiration Date
05/02/2016
Installation Instructions
FL16023 RO II 3500HP SH 36x72 08-01729 odf
Verified By: Luis R. Lomas PE-62514
Created by Independent Third Party: Yes
Evaluation Reports
FL16023 RO AE 512410 1729 odf
Created by Independent Third Party: Yes
16023.2
3500 HP SH
52x84 Finless Frame Insulating Glass
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant, No
Design Pressure: +50/-50
Other: H-R50
Certification Agency Certificate
FL16023 RO C CAC APC B9170 01-109-47-RO 3SOOHP SH
FLS 3-4IG 1-8A S2x84 R50(0502+61 odf
Quality Assurance Contract Expiration Date
05/02/2016
Installation Instructions
FI_16023 RO II 3500HP SH 52x84 08-01730 Ddf
Verified By: Luis R. Lomas PE-62514
Created by Independent Third Party: Yes
Evaluation Reports
FL16023 RO AE 512411 1730 Ddf
Created by Independent Third Party: Yes
16023.3
3500 HP SH
3602 Fin Frame Insulating Glass
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +50/-60
Other: H-R50. Windows must be glazed in accordance with
ASTM E1300-04.
Certification Agency Certificate
FL16023 RO C CAC APC B9171 01-109-47-RO 3500HP SH
FIN 3-4IG 1-8A 36X72 LC50-DP60osf(0S0716)odf
Quality Assurance Contract Expiration Date
OS/02/2016
Installation Instructions
FL16023 RO II Install instruct-3500HP SH FIN (As Tested
89171 36X72).DdP
Verified By: American Architectural Manufacturers
Association
Created by Independent Third Party:
Evaluation Reports
Created by Independent Third Party:
16023.4
3500 HP SH
52x84 Fin Frame Insulating Glass
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +50/-50
Other: H-R50. Windows must be glazed in accordance with
ASTM E1300-04.
Certification Agency Certificate
FL16023 RO C CAC APC B9I71 01-109-47-RO 3500HP SH
FIN 3-4IG 1-8A S2x84 LC50(050216)odf
Quality Assurance Contract Expiration Date
OS/02/2016
Installation Instructions
FL16023 RO II Install Instruct-3500HP SH FIN (As Tested__
69171 52X84).odf
Verified By: American Architectural Manufacturers
Association
Created by Independent Third Party:
Evaluation Reports
Created by Independent Third Party;
Contact Us :: 2601 Blair Stone Road. Tallahassee FL 32399 Phone: 850.487-1824
The State of Florida Is an AA/EEO employer. Copyright 2007-2013 State of Florida :: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send
electronic mail to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. -Pursuant to
Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if
they have one. The emalls provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to
supply a personal address, please provide the Department with an email address which can be made available to the public. To determine If you are a licensee under
Chapter 455, F.S., please click here .
Product Approval Accepts:
http://www. floridabuilding. org/prlpr_app_dti. aspx?param=wGEVXQwtDgtFPmdYiND Wr... 5 / 12/2017
I r 36" MAX
1
4" MAX.
ANCHORS TO BE EQUALLY
SPACED, SEE ANCHOR CHARTS
FOR UNIT SIZE
AND ANCHOR QUANTITY
0
FRAME WIDTH
®
12"
MAX
FRAME
HEIGHT
MAXIMUM SASH
4
SIZE, SEE NOTE
14 SHEET 1
X
i
4" MAX.
SERIES 3500 HP FLANGE PVC SINGLE HUNG WINDOW
EXTERIOR VIEW
EQUAL UNIT SHOWN, ORIEL UNIT QUALIFIED
DESIGN PRESSURE RATING IMPACT RATING
+50.0 PSF
-60.0 PSF NONE
NUMBER
Window
Height
(in)
Windmv Widffi(in)
18.001
24.00
30.001
36.00
Tamb
I Tans
Tamb
Jamb
24.00
2
2
z
2
30.00
2
2
2
3
36.00
2
1 2
3
3
42.00
3
1 3
3
q
48.00
3
3
4
4
54.00
3
3
4
5
60.00
3
4
4
5
66.00
1
3 1
4 1
5
6
72.00
3 1
4. 1
5
6
REVISIONS
DESCRIPTION DATE APPROVED
NOTES:
1) THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH
REQUIREMENTS OF THE FLORIDA BUILDING CODE.
2) WOOD FRAMING AND MASONRY OPENING TO BE DESIGNED AND ANCHORED TO PROPERLY
TRANSFER ALL LOADS TO STRUCTURE. FRAMING AND MASONRY OPENING IS THE
RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD.
3) 1X BUCK OVER MASONRY/CONCRETE IS OPTIONAL. WHERE 1X BUCK IS NOT USED
DISSIMILAR MATERIALS MUST BE SEPARATED WITH APPROVED COATING OR MEMBRANE.
SELECTION OF COATING OR MEMBRANE IS THE RESPONSIBILITY OF THE ARCHITECT OR
ENGINEER OF RECORD.
4) ALLOWABLE STRESS INCREASE OF 1/3 WAS NOT USED IN THE DESIGN OF THE PRODUCT
SHOWN HEREIN. WIND LOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD ANCHOR
CALCULATIONS.
5) FRAME MATERIAL: EXTRUDED RIGID PVC.
6) SASH UNITS MUST BE REINFORCED USING M-9201 ALUMINUM 6063—T6 REINFORCEMENT.
MEETING RAIL MUST BE REINFORCED USING M-9200 ALUMINUM 6063—T6
REINFORCEMENT.
7) UNITS MUST BE GLAZED PER ASTM E1300-04.
8) APPROVED IMPACT PROTECTIVE SYSTEM IS REQUIRED FOR THIS PRODUCT IN WIND BORNE
DEBRIS REGIONS.
9) SHIM AS REQUIRED AT EACH INSTALLATION ANCHOR WITH LOAD BEARING SHIM. SHIM
WHERE SPACE OF 1/16" OR GREATER OCCURS. MAXIMUM ALLOWABLE SHIM STACK TO BE
1/4".
10) FOR ANCHORING INTO MASONRY/CONCRETE USE 3/16" TAPCONS WITH SUFFICIENT
LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE WITH 2 5/8"
MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION
DETAILS.
11) FOR ANCHORING INTO WOOD FRAMING OR 2X BUCK USE #8 WOOD SCREW WITH
SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE.
LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS.
12) ALL FASTENERS TO BE CORROSION RESISTANT.
13) INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR
MANUFACTURER'S INSTALLATION INSTRUCTIONS, AND ANCHORS SHALL NOT BE USED IN
SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW:
A. WOOD — MINIMUM SPECIFIC GRAVITY OF G=0.42
B. CONCRETE — MINIMUM COMPRESSIVE STRENGTH OF 3.192 PSI.
C. MASONRY — STRENGTH CONFORMANCE TO ASTM C-90, GRADE N. TYPE 1 (OR
GREATER).
14) MAXIMUM SASH SIZE:
33 3/4" X 35 1 /8"
TABLE OF CONTENTS
I SHEET NO. I DESCRIPTION R
ELEVATIONS, ANCHORING LAYOUTS AND NOTES
2 — 3 1 INSTALLATION DETAILS
SIGNED: 0911312012
M650 IwDOWESTMARKETS D DOORS
1R IILIo�7i///
STREET
GRATZ, PA 17030-0370
\\\\\\
V •'\G+ENSFgiP��i
_ ir• p,�6y 51 Y+
SERIES 3500 HP FLANGE PVC SINGLE HUNG WINDOW
ALUMINUM REINFORCED - NON -IMPACT
ELEVATION, ANCHORING LAYOUT AND NOTES
;p • TAT OF • Iulu�
0��•'�IORIOV:•
DRAWN:
DWG N0.
REV
OS
sj0NAiIE�G`�\
scAEE
NTS DATE 9/12/12 a"�T190F 3
2X BUCK/WOOD FRAMING INTERIOR FINISH
BY OTHERS, 2X BUCK TO �. ` BY OTHERS
BE PROPERLY SECURED
EXTERIOR FINISH J
BY OTHERS
FLANGE TO BE WYE—
SET IN BED OF MAX.APPROVED SEALANT �M
HEAD
TO BE SET IN
A BED OF
CONSTRUCTION ADHESIVE
im—wrol 5-31."I'll,
FLANGE TO BE �JU
SET IN BED OF =l=I:-
APPROVED SEALANT
EXTERIOR FINISH
BY OTHERS
2X BUCK/WOOD FRAMING BY OTHERS, 2X BUCK TO VERTICAL CROSS SECTION
BE PROPERLY SECURED 2XBUCKIWOODFRAMING INSTALLATION
SILL TO BE SET IN
BED OF APPROVED
CONSTRUCTION ADHESIVE
1/4" MAX.
r SHIM
1 1/4" MIN.
EMBEDMENT
INTERIOR FINISH -
BY OTHERS
2X BUCK/WOOD FRAMING
BY OTHERS, 2X BUCK TO
BE PROPERLY SECURED
REVISIONS
REV DESCRIPTION I DATE I APPROVED
1/4" MAX.
SHIM
^� #8 WOOD SCREW
INTERIOR
EXTERIOR FINISH J
BY OTHERS EXTERIOR
FLANGE TO BE
SET IN BED OF
APPROVED SEALANT HORIZONTAL CROSS SECTION
2X BUCK/WOOD FRAMING INSTALLATION
MsSo WINDOEST WS AND DOORS
NLJ0
INTERIOR
T STREET`\\\�\SuR
GRATZ. PA 17030-0370
//�/'
•��GENS� 9,n:ice
OTHERFNISH
`ter
SERIES 3500 HP FLANGE PVC SINGLE HUNG WINDOW•
0
ALUMINUM REINFORCED - NON -IMPACT
XOF
DETAILS
1 �INSTALLATION
w
'�••'clpR10P•\���\
,���ss"ONA11 �G\��
DRAWN:
DWG NO.
08
REV
SCALE NT$ DAiE 8/12/12 sxEEr290F 3
MASONRY/CONCRETE
BY OTHERS
0
1 1/4" MIN.
OPTIONAL 1X BUCK BY ad
EMBEDMENT
.: c
OTHERS, IX BUCK TO BEj4o�=
PROPERLY SECURED, SEE
�T
NOTE 3 SHEET 1
I ,
I�C1C1��
FLANGE TO BE
1/4" MAX,
SET IN BED OF
APPROVED SEALANT
SHIM
HEAD TO BE SET
IN A BED OF
CONSTRUCTION ADHESIVE
SILL TO BE SET IN
BED OF APPROVED
_
CONSTRUCTION ADHESIVE
FLANGE TO BE
1/4" MAX.
SET IN BED OF
=E= r
SHIM
APPROVED SEALANT
OPTIONAL 1X BUCK BY
Qa °
MASONRY/CONCRETE
OTHERS, 1X BUCK TO BE
v _
BY OTHERS
PROPERLY SECURED. SEE
NOTE 3 SHEET 1
VERTICAL CROSS SECTION
MASONRY/CONCRETE INSTALLATION
REVISIONS
DESCRIPTION DATE I APPROVED
1 1/4" MIN.
1/4" MAX.
EMBEDMENT
I
SHIM
MASONRY/CONCRETE
3/16" TAPCON
BY OTHERS
INTERIOR
�1ggy�+1T1>J�u
2 MIN.
EDGE GE DIST.
OF
v �
v
0 �
D
OPTIONAL 1X BUCK BY
EXTERIOR
OTHERS, 1X BUCK TO BE
PROPERLY SECURED. SEE
FLANGE TO BE
NOTE 3 SHEET 1
SET IN BED OF
APPROVED SEALANT
HORIZONTAL CROSS SECTION
MASONRY/CONCRETE INSTALLATION
MWINDOWS DOORS
EST KND
STREET
GRATZ, PA 17030-0370
�\\\\\\�111II1L10,,/sso
vf//
'�GEAy.4 ;�'
SERIES 3500 HP FLANGE PVC SINGLE HUNG WINDOW
0 51
ALUMINUM REINFORCED - NON -IMPACT
_fit:
INSTALLATION DETAILS
��o TAT OF
.��
DRAWN:
Ow NO.
REV
085oEET3gOF
���/SI�NA�tEa\���
SCALE DATE
NTS g/12/12 3