.Pro ect Summary Job: wri9htsoft Date: Jun 07, 2017 Entire House QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM For: K TAIG 6104 E SEMINOLE RD., FT. PIERCE,FL 34951 Notes: Desicin Information Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Inside db 70 OF Outside db Inside db 90 75 OF OF Design TD 28 OF Design TD Daily range Relative humidity 15 L 50 OF % Moisture difference 61 gr/lb Heating Summary Structure 13170 Btuh Ducts 3882 Btuh Central vent (43 cfm) 1320 Btuh Outside air Humidification 0 Btuh Piping 0 Btuh Equipment load 18372 Btuh Infiltration Method Construction quality Fireplaces Simplified Average 0 Heatingg Coolingg Area (ft2 1210 1210 Volume (ft3) 9680 9680 Air changes/hour 0.45 0.23 Equiv. AVF (cfm) 73 37 Heating Equipment Summary Make Trade Model AHRI ref Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 100 EFF 5.1 kW 174208 BFtuh 800 cfm 0.047 cfm/Btuh 0.50 in H2O Sensible Cooling Equipment Load Sizing Structure 12778 Btuh Ducts 5905 Btuh Central vent (43 cfm) 707 Btuh Outside air Blower 0 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Equipment sensible load 18421 Btuh Latent Cooling Equipment Load Sizing Structure 2350 Btuh Ducts 1598 Btuh Central vent.(43 cfm) 1792 Btuh Outside air Equipment latent load 5740 Btuh Equipment total load 24161 Btuh Req. total capacity at 0.70 SHR 2.2 ton Cooling Equipment Summary Make Trane Trade TRAN E Cond 4TTR4025L1 Coil TEM6AOB3OH21++TDR AHRI ref 7567541 Efficiency 13.0 EER, 16 SEER Sensible cooling 16800 Btuh Latent cooling 7200 Btuh Total cooling 24000 Btuh Actual air flow 800 cfm Air flow factor 0.043 cfm/Btuh Static pressure 0.50 in H2O Load sensible heat ratio 0.77 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2017-Jun-07 14:34:60 r wrightsoft' Right -Suite® Universal 2017 17.0.14 RSU08101 Page 1 /IC.c.A ...nts1AMERON HOMES-TAIG RES.-CAPE CORAL MODEL.rup Cale = MJ8 Front Door faces: W 1- wrightsoft° Right-J® Worksheet Job: Entire House Date: Jun 07, 2017 By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@,40L.COM 1 Room name Entire House BEDROOM 3 2 Exposed wall 133.0 ft 27.0 ft 3 Room height 8.0 ft d 8.0 ft heat/cool 4 Room dimensions 1.0 x 188.0 ft 5 Room area 1210.0 ftz 188.0 ftz Ty Construction U-value Or HTM Area (ft� Load Area (ft� Load number (Btuh/fV-°F) (Btuh/ft� or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 yJ 13A-4ocs - - -0 143 . n 4 00 '- 2.55 ~ ' 200 - -185 - 741 471 - ^ 88 88 �- 352 -- - 224 _4A52ov,-._.____. ___ 0470 ._n._ 13.16 _ ._10.26 _- - 95° _---- 0 197_ __.____154 __ __0 ._ ___ _ 0 _ -- - -0 ____ _-0 13A-4ocs 0.143 a 4.00 2.55 456 371 1486 w128 113 452 288 1 D-c2ov 0.570 a 15.96 62.36 41 0 651 2544 0 0 0 0 11 4A5-2ov 0.470 a 13.16 24.96 9 1 118 225 0 0 0 0 4A5-2ov 0.470 a 13.16 25.76 15 1 197 386 15 1 197 386 4A5-20y 13.16 1 263 0 0. T -- - - 3A 13Aflocs -0_470 0143 --e s -- 4.00 ---25.76 '2.55 _-20 120 - --- 116 - - 464 . - -515 295 --- - - 0 -- - -- 0 -- - - 0 0 »1/�J 0.43 _10.4 __4 4• =----53 _ 41 0 --_--0 --------0. --.___._0 �W 223 13A-4ocs 0.143 w 4.00 2.55 288 892 567 0 0 0 0 4A5-2ov 0.470 w 13.16 25.76 45 3 592 1159 0 0 0 0 - .11 DO - - -- --,0 390 11.31 2Q 227 - 0 ` ;E-`.12COsw - - U-91 -w - _-'----2.55,---1.28 _10.92 -_ - - -20 248.-----24 - - 8---- - _219 63Z - - 318 ----0 ---___ Q_---_ -- __0__.___- -- -0 0. - - -..4 ----. - -0 C 1613-44ad 0.022 - 0.62 1.16 1210 1210 745 1398 188 188 116 217 3683 __- _0 ._- JIBS ____-27 __-748,._�____0 6 c) AED excursion 0 -51 Envelope loss/gain 10936 9246 1866 1065 12 a) Infiltration 2234 612 454 124 b) Room ventilation 0 0 0 0 13 Intemal gains: Occupants @ 230 4 920 1 230 Appliances/other 2000 0 Subtotal (lines 6 to 13) 13170 12778 2319 1419 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 13170 12778 2319 1419 15 Duct loads 29% 46% 3882 5905 29% 46% 684 6% Total room load T17052 18683 3003 2074 Air required (cfm) 800 800 1141 89 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightsoft' 2017-Jun-07 14:34:50 �� Right -Suite® Universal 2017 17.0.14 RSU08101 Page 1 ..nts\AMERON HOMES-TAIG RES.-CAPE CORAL MODEL.rup Calc = MJ8 Front Door faces: W wrightsoft° Right-M Worksheet Job: Entire House Date: Jun 07, 2017 By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946.Phone: 772466-6799 Fax: 772-466-6796 Email: QUICKCALCS@_40L.COM 1 Room name BEDROOM 2 BATH 2 2 Exposed wall 26.0 ft 5.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 1.0 x 156.0 ft 5.0 x 8.0 ft 5 Room area 156.0 ft2 40.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft� Load number (Btuh/ft;°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 IN -___G. :13A-4ocs 4A5-2ov_._ ---- 0 143 .... _,_0.47.0 n _,n_ 4 DO __ 13.16 2.55 __.10.26 112 97 -'_____-Q 388 --._ 197 - 247 _154 0 _ U 0 _ o 0 13A-4ocs 0.143 a 4.00 2.55 0 0 0 0 0 0 0 0 1 D-c2ov 0.570 a 15.96 62.36 0 0 0 0 0 0 0 0 11 4A5-2ov 0.470 a 13.16 24.96 0 0 0 0 0 0 0 0 4A5-2ov 0.470 a 13.16 25.76 0 0 0 0 0 0 0 0 _ 4A5-2ov � -0 470 e 13.16 0 0 0 0 0 0 0 0 13A-4ocs , __25.76 0 0 . 0 0 _ 0 __. 0 470 _s__ _13.16 __ 10.26 . Q, _0 W 13A-4ocs 0.143 w 4.00 2.55 96 81 324 206 40 40 160 102 4A5-2ov 0.470 w 13.16 25.76 15 1 197 386 0 0. 0 0 -_ P 11DO 12G Osw _.____m 0.390 _. 0 091. w _ 10.92 __ _2 55 11.31 . 1 28 0_ a_ Q 0 ____0, 0 0 _ __0 C 1613-44ad 0.022 - 0.62 1.15 156 156 96 180 40 40 25 46 6 c) AED excursion 30 -17 Envelope loss/gain 1924 1203 323 131 12 a) Infiltration 437 120 84 23 b) Room ventilation 0 0 0 0 13 Intemal gains: Occupants @ 230 1 230 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 2360 1553 154 Less external load 0 0 0 Less transfer 0 0 ff407 0 Redistribution 0 0 0 14 Subtotal 2360 1553 154 15 Duct loads 29% 46% 696 718 29% 46% 71 Total room load 3056 2270 527 225 Air required (cfm) 143 97 25 10 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. .� wrightsoft" 2017-Jun-07 14:34:50 Right -Suite® Universal 2017 17.0.14 RSU08101 Page 2 �� ...nts\AMERON HOMES-TAIG RES.-CAPE CORAL MODEL.rup Calc = MJ8 Front Door faces: W - wrightsoft° Right-M Worksheet Job: Entire House Date: Jun 07, 2017 QUICK CALCS, INC. By: 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name KITCHEN DINING 2 Exposed wall 10.0 ft 10.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 5 Room dimensions Room area 10.0 x 11.0 ft 110.0 ft2 10.0 x 11.0 ft 110.0 ftz Ty Construction U-value Or HTM Area (W) Load Area (ft� Load number (Btuh/ftZ-°F) (Btuh/ftj or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11�! - 13A 11ocs rc 0 143 n 4 00 v 2.55 0- 0 _ _ 0 _ _ .. O .r _____ 0 0 0 o �Gw _4A5 2ov_ 11 13AAocs 1 D-c2ov 4A5-2ov 4A5.20v 0.143 0.570 0.470 0.470 a a a a 4.00 15.96 13.16 13.16 2.55 62.36 24.96 25.76 80 0 9 0 71 0 1 0 284 0 118 0 181 0 225 0 80 41 0 0 39 0 0 0 157 651 0 0 100 2544 0 0 _ G 4A5_20v _ 13A-flocs ;4A5_-2ov ___ __ __ _ 0.470 ,0143 - 0 470 e s es_ 13.16 4 00 13 16 25.76 _10.26. 0 0 0 _ . 0 0 0 0 0 _ - 0 ____0 _ 0 0 0 .0 - _. r0 0 ___--9 __. 0 __0 . _ _ O , _ 0 _ W 13A-4ocs 0.143 w 4.00 2.55 0 0 0 0 0 0 _ 0 0 4A5.2ov 11DO j2C-0sw _. __.. 0.470 0_390 _ 0.091-u w w 13.16 10.92 Y 2:55 25.76 _ _11.31 _ 1.28...___ 0 0 � 0 0 0 0 0 0 0 0 0 0 0 0 _ _ Q 0 �0 ._---_0 �-0._-A£ _0 :___ _0 _ _.� __ C,�__- 166_44ad _ 0.022 0.62 1.15 110 110 127 110 110, 68 127. F_.__ _ :22A_tpl_. _ _ 0 909 _.. 27.69 _. _ 0:00. �_ 110, _ 10. ._ ___.68 _r�277 _ -,.. __._._ _0 �-_ _---__10 .__ r 27Z _ ___ ____--11Q 6 c) AED excursion -211 105 Envelope loss/gain 747 322 1153 2876 12 a) Infiltration 168 46 168 46 b) Room ventilation 0 0 0 0 13 Intemal gains: Occupants @ 230 0 0 0 0 Appliances/other 2000 0 Subtotal (lines 6 to 13) 915 2368 1321 2922 Less external load 0 0 0 0 14 Less transfer Redistribution Subtotal 0 0 915 0 0 2368 0 0 1321 0 0 2922 15 Duct loads 29% 46% 270 1094 29% 46% 389 1350 F1Total room load Air required (cfm) 1185 56 3462 148 1 1 1710 80 4272 183 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrigF�tsoft® 2017-Jun-07 14:34:50 Right -Suite® Universal 2017 17.0.14 RSU08101 Page 3 ...ntsXAMERON HOMES-TAIG RES.-CAPE CORAL MODEL.rup Calc = MJ8 Front Door faces: W - wrightsoft° Right-M Worksheet Job: Entire House Date: Jun 07, 2017 By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area LIVING 19.0 ft 8.0 ft heat/cool 1.0 x 296.0 ft 296.0 ftz MASTERB EDROOM 12.0 ft 8.0 ft heat/cool 12.0 x 15.0 ft 180.0 ftz Ty Construction number U-value (Btuh/Wt *F) Or HTM (Btuh/ft) Area (ft� or perimeter (ft) Load (Btuh) Area (ft� or perimeter (ft) Load (Btuh) Heat Cool Gross NIP/S Heat Cool Gross N/P/S Heat Cool 6 11 1�/ -- _ _ , _ 13A-4ocsY--- 4A572ov_ __. - - - 13A-4ocs 1Dc2ov 4A5-2ov 4A5.20v 4A5 2ov_ .13A-4ocs - 13A-4ocs 4A5.2ov 11D0 16B-34ad ---0.143 ----_0.470 0.143 0.570 0.470 0.470 0.470 0.143, ------ _-__-_0470 0.143 0.470 -0390 0091._-�___2:55 0.022 n n- a a a a e_.. s --s._. w w w.- - -4.00 -`13.16 4.00 15.96 13.16 13.16 13 16 4.00 _ 13,16,.___.10 4.00 13.16 10.92 0.62 ---2.55 __ 10.26- 2.55 62.36 24.96 25.76 25 76 2.55 26, 2.55 25.76 -11.31 _1.28__._,__80.__- 1.15 - 0 - 0. 0 0 0 0 _ 0 0 _ ._ -0 152 30 _ 20 296 - --0 - 0 0 0 0 0 _ _ . _ _0 0 0 102 2 ----20 80 296 - - - - - 0- 0 0 0 0 0 0 _--____0.. 408 395 -- 219 - .___2 182 -- 0 -- - - -0 0 0 0 0 _ 0 '- --0 ._.. ___0 259 773 -- -227- ____ 103__._96 342 --- Q - . -- -- _0 96 0 0 0 _ 20 0 __ ___ 0.--_-- 0 0 ---0._.. 180 - - 0 -- ---0 76 0 0 0 _ _ 1 0 _ .0 0 0 --� -96 180 -- 0 - -- - --0 304 0 0 0 _ _._ _263 0_ ___. --- 0 193 0 0 0 5.15 0 ____ _ _0. 0 0 ----_. 208 _ 0 W -0 0 0 ----� 245.__.123. 111 --- - C 6 c) AED excursion 258 -27 Envelope loss/gain 1935 1962 1255 1012 12 a) Infiltration b) Room ventilation 319 0 87 01 202 0 55 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 0 2 460 0 Subtotal (lines 6 to 13) 2254 2049 1457 1527 14 15 Less external load Less transfer Redistribution Subtotal Duct loads 29% 46% 0 0 0 2254 664 0 0 0 2049 947 29% 46% 0 0 0 1457 429 0 0 0 1527 706 Total room load Air required (cfm) 2918 137 2996 128 1886 88 2233 96 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. c wrightsoft" 2017-Jun-0714:34:50 Right -Suite® Universal 2017 17.0.14 RSU08101 Page 4 '�� ...nts\AMERON HOMES-TAIG RES.-CAPE CORAL MODEL.rup Calc = MJ8 Front Door faces: W * wrightsoft° Right-M Worksheet Entire House QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax: 772-466-6796 Email: QUICKCALCS(.,,AOL.COM Job: Date: Jun 07, 2017 By: 1 Room name WIC M BATH 2 Exposed wall 15.0 ft 9.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 5 Room dimensions Room area 1.0 x 49.0 ft 49.0 ft2 9.0 x 9.0 ft 81.0 ft2 Ty Construction U-value Or HTM Area (W) Load Area (ft2) Load number (Btuh/W-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 G_ IM74ocs V _4A52ov-_._._: _ '0 143 _ _0470 n _-n... 4 00 .__13.16 -2.65 10.26. 0 _0. - p �_.-Q. 0 _.0 _--� oo 0 0 o 11 W 13A-4ocs 1 D-c2ov 4A5-2ov 4A5-2ov 4A5-2ov 13A-flocs 0.143 0.570 0.470 0.470 0470 0143 a a a a a _, s 4.00 15.96 13.16 13.16 13..16 4:00 2.55 62.36 24.96 25.76 2576 2 55 72 0 0 0 ___ 0 48 72 0 0 0 ______0 48 -_. 288 0 0 0 -0 192 183 0 0 0 0 _.._ 122 0 0 0 0 _ 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 __ 72 _.r_- 68 .__ V __ 272 __. 173 W „^ .P __..12C C .- _ 13A-4ocs 4A5-2ov 11D0 Osw-- „166-44ad _ _ 0.143 0.470 0.390 0 091. _ 0.022 0.989 w w w __ ., --a 13 96 4.00 13.16 10.92 2 55 0.62 _. n27.69415 , 10.26 2.55 25.76 11.31 _ 1,28 1.15 0 0 0 0: 49 0 0 0 ____0_, 49 0 0 _ 0 _. 0. 30 0 0 _ 0 •__ �0 57 _ 0 0 0 0 �183 - _50 249 0 0 _0 _... 92. - 94 _ __ _Q 0 0 _ _ 0 _� 72 81, _ �81. 0 0 _ _ 0 r_ 72 P. - 81 _ 9 6 c) AED excursion 43 -44 Envelope loss/gain 926 319 807 356 12 a) Infiltration 252 69 151 41 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 1178 388 959 398 14 15 Less external load Less transfer Redistribution Subtotal Duct loads 29% 46% 0 0 0 1178 347 0 0 0 388 179 290 46% 0 0 0 959 283 0 0 0 398 184 Total room load Air required (cfm) 1525 721 568 24 1241 58 681 25 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. . wrigF�tsoft' 2017-Jun-0714:34:50 Right -Suite® Universal 2017 17.0.14 RSU08101 Page 5 'CC*` ...ntsWMERON HOMES-TAIG RES.-CAPE CORAL MODEL.rup Calc = MJ8 Front Door faces: W 9 ® Duct System Summary Job: wri htsoft Date: Jun 07, 2017 Entire House By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax. 772-466-6796 Email: QUICKCALCS@,AOL.COM For: K TAI G 6104 E SEMINOLE RD., FT. PIERCE,FL 34951 External static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.320 in/100ft 800 cfm Cooling 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.320 in/100ft 800 cfm 156 ft Name Design (Btuh) Htg (cfm) Clg (cfm) Design FR Diam (in) H x W (in) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH 2 h 527 25 10 0.335 4.0 Ox0 VIFx 34.1 115.0 st2 BEDROOM 2 h 3056 143 97 0.320 7.0 Ox 0 VIFx 41.0 115.0 st2 BEDROOM 3 h 3003 141 89 0.326 7.0 Ox 0 VIFx 38.3 115.0 st2 DINING c 4272 80 183 0.367 8.0 Ox 0 VIFx 21.1 115.0 st1 KITCHEN c 3462 56 148 0.339 7.0 Ox 0 VIFx 32.6 115.0 st2 LIVING h 2918 137 128 0.331 6.0 Ox0 VIFx 36.2 115.0 st2 M BATH h 1241 58 25 0.379 5.0 Ox0 VIFx 17.1 115.0 st1 MASTERB EDROOM c 2233 88 96 0.390 5.0 Ox 0 VIFx 13.2 115.0 st1 WIC h 1525 72 24 0.371 4.0 Ox 0 VIFx 19.6 115.0 st1 Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st2 Peak AVF 501 472 0.320 639 12.0 0 x 0 VinlFlx st1 Peak AVF 299 328 0.367 601 10.0 0 x 0 VinlFlx Return Branch Detail Table Name Grille Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Matl Trunk rb1 Ox0 800 800 0 0 0 0 Ox 0 VIFx .� ' r wrightsoft® Right -Suite® Universal 2017 17.0.14 RSU08101 .4CCA ...ntsWMERON HOMES-TAIG RES.-CAPE CORAL MODEL.rup Calc = MJ8 Front Door faces: W 2017-Jun-07 14:34:50 Page 1